Search NASA⌕ Search

SEARCH · Search NASA

Results for “BUFFER STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Buffer thermal energy storage for an air Brayton solar engine

The application of latent-heat buffer thermal energy storage to a point-focusing solar receiver equipped with an air Brayton engine was studied. To demonstrate the effect of buffer thermal energy storage on engine operation, a computer program was written which models the recuperator, receiver, and thermal storage device as finite-element thermal masses. Actual operating or predicted performance data are used for all components, including the rotating equipment. Based on insolation input and a specified control scheme, the program predicts the Brayton engine operation, including flows, temperatures, and pressures for the various components, along with the engine output power. An economic parametric study indicates that the economic viability of buffer thermal energy storage is largely a function of the achievable engine life.

Strumpf, H. J.↗

ATLAS Data Carousel

The ATLAS experiment at CERN's LHC stores detector and simulation data in raw and derived data formats across more than 150 Grid sites world-wide, currently in total about 200PB on disk and 250PB on tape. Data have different access characteristics due to various computational workflows, and can be accessed from different media, such as remote I/O, disk cache on hard disk drives or SSDs. Also, larger data centers provide the majority of offline storage capability via tape systems. For the High-Luminosity LHC (HL-LHC), the estimated data storage requirements are several factors bigger than the present forecast of available resources, based on a flat budget assumption. On the computing side, ATLAS Distributed Computing was very successful in the last years with high performance and high throughput computing integration and in using opportunistic computing resources for the Monte Carlo simulation. On the other hand, equivalent opportunistic storage does not exist. ATLAS started the "Data Carousel" project to increase the usage of less expensive storage, i.e. tapes or even commercial storage, so it is not limited to tape technologies exclusively. Data Carousel orchestrates data processing between workload management, data management, and storage services with the bulk data resident on offline storage. The processing is executed by staging and promptly processing a sliding window of inputs onto faster buffer storage, such that only a small percentage of input data are available at any one time. With this project, we aim to demonstrate that this is the natural way to dramatically reduce our storage cost. The first phase of the project was started in the fall of 2018 and was related to I/O tests of the sites archiving systems. Phase II now requires a tight integration of the workload and data management systems. Additionally, the Data Carousel studies the feasibility to run multiple computing workflows from tape. The project is progressing very well and the results presented in this document will be used before the LHC Run 3.

97 MATHEMATICS AND COMPUTING↗

Techno-economic optimization of renewable urea production for sustainable agriculture and CO 2 utilization

Abstract Urea is the most used nitrogen fertilizer due to its ease of storage, transportation, and application. It is made by combining ammonia and carbon dioxide (CO 2 ), both of which are produced predominantly from fossil fuels at present. The recent momentum behind ammonia production using renewable-powered electrolysis offers an opportunity to both make urea in a more sustainable way and utilize CO 2 from external sources. In this work, we present a techno-economic optimization model to minimize the cost of making urea in this way. The model allows for time-varying chemical production in response to renewable variability by simultaneously optimizing production facility design and hourly operation. We performed a case study for Minnesota considering the use of byproduct CO 2 from bioethanol production. We found that the present-day levelized cost of renewable urea is between $268 mt −1 and $413 mt −1 at likely implementable production scales up to 250 000 mt yr −1 . This is within the range of historical conventional urea prices while offering at least 78% carbon intensity reduction. Projecting to 2030, there is a clear economic case for renewable urea production with levelized cost as low as $135 mt −1 due to technology improvement and electrolysis manufacturing expansion, facilitating a urea production scale increase to 525 000 mt yr −1 . Optimal facilities use wind energy, with hydrogen and ammonia production operating in a flexible, time-varying way to minimize battery and hydrogen storage capacities. Urea production operates near steady state due to the relatively low cost of intermediate ammonia buffer storage. A mix of imported methane and locally produced hydrogen are used to provide heat for steam consumed in the urea synthesis.

Chemistry↗

REDOX electrochemical energy storage

Reservoirs of chemical solutions can store electrical energy with high efficiency. Reactant solutions are stored outside conversion section where charging and discharging reactions take place. Conversion unit consists of stacks of cells connected together in parallel hydraulically, and in series electrically. Stacks resemble fuel cell batteries. System is 99% ampere-hour efficient, 75% watt hour efficient, and has long projected lifetime. Applications include storage buffering for remote solar or wind power systems, and industrial load leveling. Cost estimates are $325/kW of power requirement plus $51/kWh storage capacity. Mass production would reduce cost by about factor of two.

Thaller, L. H.↗

Space-Based Communications Buffer Sizing

This paper considers the transmission interruption timing for space-based communications due to weather. The length of the weather interruption is one of the main influences determining the size of the storage needed to save the data to be sent at a later time. This analysis uses the Markov chain probabilities for weather to determine how many cloudy or rainy time steps in a row will not allow data transmission. The mean and standard deviation are computed, which along with the average data rate to be sent can be used to help size storage buffers in which to save data between periods of good weather.

Handler, Louis M.↗

Geologic Modeling and Simulation Report for the Aquistore Project

The Plains CO 2 Reduction (PCOR) Partnership, through the Energy & Environmental Research Center (EERC), is collaborating with the Petroleum Technology Research Centre (PTRC) on site characterization; modeling and simulation; risk assessment; public outreach; and monitoring, verification, and accounting (MVA) activities for the Aquistore project. The Aquistore project is a carbon capture, utilization, and storage (CCUS) project situated near the town of Estevan, Saskatchewan, Canada, and the U.S.–Canada border. This project is managed by PTRC and will serve as buffer storage of carbon dioxide (CO 2 ) from the SaskPower Boundary Dam CCUS project, the world’s first commercial-scale postcombustion CCUS project from a coal-fired electric generating facility. To date, an injection well and an observation research well (~500 ft apart) have been drilled and completed at the Aquistore site, with injection anticipated to begin in 2014. Using a combination of site characterization data provided by PTRC and independently acquired information, the PCOR Partnership has constructed a static geologic model to assess the potential storage capacity of the Aquistore site and provide the foundation for dynamic simulation. The geologic model and the results of the predictive simulations will be used in the risk assessment process to help define an overall monitoring plan for the project and to assure stakeholders that the injected CO 2 will remain safely stored at the Aquistore site.

54 ENVIRONMENTAL SCIENCES↗

Two-tier tube-trailer operation method and system to reduce hydrogen refueling cost

A method and system are provided for operating refueling station tube-trailers and compressors to reduce hydrogen refueling cost. A hydrogen refueling station includes a two-tier fuel supply of pressure vessels on a refueling station tube-trailer, with a first tier and a second tier of pressure vessels including at least one or more pressure vessels connected together. A separate control unit is coupled to the first tier and the second tier of pressure vessels with each of the control units coupled to a compressor. The compressor is coupled to a high pressure buffer storage by a separate control unit. In operation, pressure is monitored in the each tier. Hydrogen is consolidated selectively between the first tier of pressure vessel banks, the second tier pressure vessels, and the high pressure buffer. Based upon monitored pressures, one of the first tier of pressure vessels, the second tier pressure vessel banks, and the high pressure buffer is used to refuel vehicles.

Reddi, Krishna↗

Comparative I/O workload characterization of two leadership class storage clusters. In: PDSW '15 Proceedings of the 10th Parallel Data Storage Workshop

The Oak Ridge Leadership Computing Facility (OLCF) is a leader in large-scale parallel file system development, design, deployment and continuous operation. For the last decade, the OLCF has designed and deployed two large center-wide parallel file systems. The first instantiation, Spider 1, served the Jaguar supercomputer and its predecessor, Spider 2, now serves the Titan supercomputer, among many other OLCF computational resources. The OLCF has been rigorously collecting file and storage system statistics from these Spider systems since their transition to production state. In this paper we present the collected I/O workload statistics from the Spider 2 system and compare it to the Spider 1 data. Our analysis show that the Spider 2 workload is more more write-heavy I/O compared to Spider 1 (75% vs. 60%, respectively). The data also show the OLCF storage policies such as periodic purges are effectively managing the capacity resource of Spider 2. Furthermore, due to improvements in tdm_multipath and ib_srp software, we are utilizing the Spider 2 system bandwidth and latency resources more effectively. The Spider 2 bandwidth usage statistics shows that our system is working within the design specifications. However, it is also evident that our scientific applications can be more effectively served by a burst buffer storage layer. All the data has been collected by monitoring tools developed for the Spider ecosystem. We believe the observed data set and insights will help us better design the next-generation Spider file and storage system. It will also be helpful to the larger community for building more effective large-scale file and storage systems.

Gunasekaran, Raghul↗

Tuning HDF5 subfiling performance on parallel file systems

Subfiling is a technique used on parallel file systems to reduce locking and contention issues when multiple compute nodes interact with the same storage target node. Subfiling provides a compromise between the single shared file approach that instigates the lock contention problems on parallel file systems and having one file per process, which results in generating a massive and unmanageable number of files. In this paper, we evaluate and tune the performance of recently implemented subfiling feature in HDF5. In specific, we explain the implementation strategy of subfiling feature in HDF5, provide examples of using the feature, and evaluate and tune parallel I/O performance of this feature with parallel file systems of the Cray XC40 system at NERSC (Cori) that include a burst buffer storage and a Lustre disk-based storage. We also evaluate I/O performance on the Cray XC30 system, Edison, at NERSC. Our results show performance benefits of 1.2X to 6X performance advantage with subfiling compared to writing a single shared HDF5 file. We present our exploration of configurations, such as the number of subfiles and the number of Lustre storage targets to storing files, as optimization parameters to obtain superior I/O performance. Based on this exploration, we discuss recommendations for achieving good I/O performance as well as limitations with using the subfiling feature.

97 MATHEMATICS AND COMPUTING↗

Reference Station Design for Heavy-Duty Vehicles

Five alternative design configurations for a heavy-duty hydrogen refueling truck stop are detailed in this work. Each of the station concepts provides fast, 5-minute, 50 kg fills of up to 4 vehicles simultaneously, with a station capacity of 4200 kg/day. Two on-site production stations using PEM electrolysis are considered: one with off-peak production of the daily capacity; and one with on-demand production of hydrogen during vehicle refueling. Three delivered liquid hydrogen station concepts are considered: one with the same, high-pressure cascade storage system for dispensing as the electrolysis supplied stations, with low-pressure vaporization of the liquid hydrogen and pressurization via a compressor; and two with on-demand pressurization: one by low-pressure vaporization and compressors; and one with a cryogenic pump and high-pressure vaporization. Design, economic, and operational considerations for each of the components needed in these station concepts is provided. Of all the station concepts, the delivered liquid station with a low-pressure vaporizer and a cascade dispensing system has the lowest capital costs and equipment footprint, but the second highest operating costs primarily due to high costs for liquid hydrogen delivery. The lowest operating cost station is that with on-site production via PEM electrolysis at off-peak hours with a cascade delivery system. The low-pressure buffer storage system and electrolyzers have a large footprint and considerable capital costs, but could result in a low total cost of ownership, depending on the design timeline. The liquid hydrogen station with a cryo-pump has moderate capital costs, the lowest operating costs of the three delivered hydrogen stations, and the same small equipment footprint as the delivered liquid, cascade dispensing system. As cryogenic pumping technology improves and the capital costs for these pumps decreases, this station concept will become even more favorable. Three-dimensional renderings of the five station concepts provide station designers with a starting point for the development of heavy-duty refueling stations.

08 HYDROGEN↗

CMS Data transfer operations after the first years of LHC collisions

CMS experiment utilizes distributed computing infrastructure and its performance heavily depends on the fast and smooth distribution of data between different CMS sites. Data must be transferred from the Tier-0 (CERN) to the Tier-1s for processing, storing and archiving, and time and good quality are vital to avoid overflowing CERN storage buffers. At the same time, processed data has to be distributed from Tier-1 sites to all Tier-2 sites for physics analysis while Monte Carlo simulations sent back to Tier-1 sites for further archival. At the core of all transferring machinery is PhEDEx (Physics Experiment Data Export) data transfer system. It is very important to ensure reliable operation of the system, and the operational tasks comprise monitoring and debugging all transfer issues. Based on transfer quality information Site Readiness tool is used to create plans for resources utilization in the future. We review the operational procedures created to enforce reliable data delivery to CMS distributed sites all over the world. Additionally, we need to keep data and meta-data consistent at all sites and both on disk and on tape. In this presentation, we describe the principles and actions taken to keep data consistent on sites storage systems and central CMS Data Replication Database (TMDB/DBS) while ensuring fast and reliable data samples delivery of hundreds of terabytes to the entire CMS physics community.

Kaselis, Rapolas↗

Principles to adapt financing mechanisms for fully integrated hybrid energy systems

As the electricity sector evolves, and as all energy types (thermal, electric, chemical, etc.) become more coupled, there has been increased interest to develop and deploy hybrid energy systems (HES). This work focuses on fully integrated HES, where there are multiple energy sources and multiple energy products, often coupled through a storage buffer. A significant amount of the available literature on this work describes technology pathways for fully integrated HES; however, it is unclear how financial institutions should treat these systems. Fully integrated HES represent an increase in complexity from their stand-alone counterparts, but they also potentially mitigate financial risk and provide value to the energy system, which has not yet been accounted for in financing mechanisms that could help to enable such systems. This paper provides some examples of fully integrated HES and proposes principles to help adapt financing to adequately capture the value of such systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LBNF/DUNE Liquid Argon Roadmap

The Deep Underground Neutrino Experiment (DUNE) is an international flagship venture to unlock the mysteries of neutrinos. Hosted at the Sanford Underground Research Facility (SURF) and supported by the Long-Baseline Neutrino Facility (LBNF), DUNE relies on nearly 75,000 tonnes of ultrapure liquid argon (LAr) housed in state-of-the-art cryostats. Transporting such vast quantities of LAr to its destination a mile underground in Lead, SD, is a logistical and engineering challenge. The process begins with securing large quantities of liquid argon from suppliers located far from the site, with major sources situated near Houston, TX and Chicago, IL. The receiving facility, located atop a mountain with steep, often snow-covered access roads, provides limited maneuverability for trucks and can only handle two deliveries simultaneously. The facility serves as an entry point for argon to the greater LBNF cryogenic system. It is furnished with truck unloading stations, limited buffer storage of some 280 tonnes capacity, and vaporizers. The last are crucial for converting liquid argon into gas for transfer down the Ross Shaft, eliminating the need for cryogens in the vertical pipeline. These constraints, along with other operational factors, cap the delivery rate at 70 tonnes per day. Once underground, the argon is purified and recondensed before filling the cryostats. This roadmap outlines the integrated supply chain and cryogenic systems that enable the delivery of LAr to support DUNE’s groundbreaking physics research.

Maciazka, Matt [Fermilab]↗

Encode/Decode facility for FORTRAN 4

An ENCODE and DECODE facility, a subroutine added to a FORTRAN 4 library, allows alphanumeric data to be transfered to or from an area in memory rather than to or from external input/output devices. A buffer storage array allows the operations on the data prior to writing.

Cohn, C. E.↗

Data transfer system Patent

Data acquisition and processing system with buffer storage and timing device for magnetic tape recording of PCM data and timing information

Coolidge, J. E.↗

Low-light-level integrating video system

System consists of television camera using 25 mm SEC vidicon, low dispersion spectrograph, and digital video image system used for buffer storage of video data during tube readout scanning. Six-bit ADC converts video to digital data which are stored on magnetic tape for future evaluation.

Duncan, B. J.↗

Phase 1 of the First Solar Small Power System Experiment (experimental System No. 1). Volume 3: Appendix E - N

The design of a solar electric power plant for a small community is reported. Topics covered include: (1) control configurations and interface requirements for the baseline power system; (2) annual small power system output; (3) energy requirements for operation of the collectors and control building; (4) life cycle costs and reliability predictions; (5) thermal conductivities and costs of receiver insulation materials; (6) transient thermal modelling for the baseline receiver/thermal transport system under normal and inclement operating conditions; (7) high temperature use of sodium; (8) shading in a field of parabolic collectors; and (9) buffer storage materials.

Clark, T. B.↗

solar thermal power systems advanced solar thermal technology project, advanced subsystems development

The preliminary design for a prototype small (20 kWe) solar thermal electric generating unit was completed, consisting of several subsystems. The concentrator and the receiver collect solar energy and a thermal buffer storage with a transport system is used to provide a partially smoothed heat input to the Stirling engine. A fossil-fuel combustor is included in the receiver designs to permit operation with partial or no solar insolation (hybrid). The engine converts the heat input into mechanical action that powers a generator. To obtain electric power on a large scale, multiple solar modules will be required to operate in parallel. The small solar electric power plant used as a baseline design will provide electricity at remote sites and small communities.

Source record↗