Time-Resolved OH-PLIF Assessment of Deflagrations Levels in a CH4-O2 Rotating Detonation Rocket Combustor
The parasitic loss incurred by deflagrative pre-burning is considered to be one of the key challenges to the effective implementation of rotating detonation engine (RDE) systems. Thus far, there have been relatively limited high fidelity, spatio-temporally resolved measurements of the pre-burning process as a function of the reactant conditions and composition within an RDE. In this work, simultaneous high-repetition-rate broadband OH* chemiluminescence and OH planar laser-induced fluorescence (PLIF) imaging are employed to investigate deflagrative burning dynamics in a fully optically accessible CH4-O2 RDE as compared to a H2-air systems under the same conditions. A custom-built optical parametric oscillator (OPO) is coupled with a high-repetition-rate burst-mode laser to generate the 284 nm source for the excitation of the Q1(9) transition of the OH radical. Significant deflagrative burning is observed throughout the chamber as a consequence of the oxygen-rich environment. Trailing wave systems that consume unburned reactants in the region immediately following the primary detonation wave are observed. The formation of a product gas recirculation zone that entrains and combusts incoming reactants is observed, and quantitative analysis is performed to gain valuable insight into deflagration characteristics. At an oxidizer mass flux of Gox ≈ 350kg/m2/s, it is found that the levels of pre-wave burning in CH4-O2 are a factor of ∼2-3 times higher than in H2-air in the region directly ahead of the detonation wave at a global equivalence ratio Φ ≈ 1.0. This study highlights the key roles of ignition delay and turbulent mixing of the combustion product and reactant fields on the levels of pre-burning and establishes a methodology for further investigation, such as for the effects of various RDE inlet configurations.