Search NASA⌕ Search

SEARCH · Search NASA

Results for “Backward Compatibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Global Phase and Magnitude Synchronization of Coupled Oscillators With Application to the Control of Grid-Forming Power Inverters

In this paper, we explore a new approach to synchronization of coupled oscillators. In contrast to the celebrated Kuramoto model, we do not work in polar coordinates and do not consider oscillations of fixed magnitude. We propose a synchronizing feedback based on relative state information and local measurements that induces consensus-like dynamics. We show that, under a mild stability condition, the combination of the synchronizing feedback with a decentralized magnitude control law renders the oscillators' almost globally asymptotically stable with respect to set points for the phase shift, frequency, and magnitude. We apply these result to rigorously solve an open problem in control of inverter-based ac power systems. In this context, the proposed control strategy can be implemented using purely local information, induces a grid-forming behavior, and ensures that a network of ac power inverters is almost globally asymptotically stable with respect to a prespecified solution of the ac power-flow equations. Moreover, we show that the controller exhibits a droop-like behavior around the standard operating point, thus, making it backward compatible with the existing power system operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthesizing Virtual Oscillators to Control Islanded Inverters

Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging- and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real- and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evolvix BEST Names for semantic reproducibility across code2brain interfaces

Names in programming are vital for understanding the meaning of code and big data. We define code2brain (C2B) interfaces as maps in compilers and brains between meaning and naming syntax, which help to understand executable code. While working toward an Evolvix syntax for general‐purpose programming that makes accurate modeling easy for biologists, we observed how names affect C2B quality. To protect learning and coding investments, C2B interfaces require long‐term backward compatibility and semantic reproducibility (accurate reproduction of computational meaning from coder‐brains to reader‐brains by code alone). Semantic reproducibility is often assumed until confusing synonyms degrade modeling in biology to deciphering exercises. We highlight empirical naming priorities from diverse individuals and roles of names in different modes of computing to show how naming easily becomes impossibly difficult. We present the Evolvix BEST (Brief, Explicit, Summarizing, Technical) Names concept for reducing naming priority conflicts, test it on a real challenge by naming subfolders for the Project Organization Stabilizing Tool system, and provide naming questionnaires designed to facilitate C2B debugging by improving names used as keywords in a stabilizing programming language. Our experiences inspired us to develop Evolvix using a flipped programming language design approach with some unexpected features and BEST Names at its core.

97 MATHEMATICS AND COMPUTING↗

TU-PIS-Exhibit Hall-1: Therapy: Deformable Image Registration, Contour Propagation, and Dose Mapping

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-2: Deformable Image Registration, Contour Propagation, and Dose Mapping inMIM Maestro - MIM Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-3: Under the hood of Deformable Image Registration: Similarity Functions and Regularization

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-4: Philips Pinnacle3 clinical solutions for adaptive radiotherapy

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-5: ABAS - Atlas Based Auto Segmentation

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-00: Use of End-Of-Life Brachytherapy Devices

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-01: Definition and Purpose of End-Of-Life for Brachytherapy Devices and Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-02: Physicist’s Responsibility On “End-Of-Life for Brachytherapy Devices and Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-03: Proposed Solutions to End-Of-Life Issue

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

Structure- and Physics-Preserving Reductions of Power Grid Models

The large size of multiscale, distribution and transmission, power grids hinders fast systemwide estimation and real-time control and optimization of operations. This paper studies graph reduction methods of power grids that are favorable for fast simulations and follow-up applications. While the classical Kron reduction has been successful in reduced order modeling of power grids with traditional, hierarchical design, the selection of reference nodes for the reduced model in a multiscale, distribution and transmission, network becomes ambiguous. In this work we extend the use of the iterative Kron reduction by utilizing the electric grid's graph topology for the selection of reference nodes, consistent with the design features of multiscale networks. Additionally, we propose further reductions by aggregation of coherent subnetworks of triangular meshes, based on the graph topology and network characteristics, in order to preserve currents and build another power-flow equivalent network. Our reductions are achieved through the use of iterative aggregation of subgraphs that include general tree structures, lines, and triangles. Important features of our reduction algorithms include that (i) the reductions are either equivalent to the Kron reduction or otherwise produce a power-flow equivalent network; (ii) due to the mentioned power-flow equivalence, the reduced network can model the dynamic of the swing equations for a lossless, inductive, steady state network; (iii) the algorithms efficiently utilize hash tables to store the sequential reduction steps. The third feature allows for easy reintroduction of detailed models into the reduced, conceptual network and makes the final reduced order model backward compatible with a sequence of intermediate, partially reduced networks with varying resolution---the ordered sequence of iterative reductions corresponds to a sequence of reduced order models. The performance of our graph reduction algorithms and features of the reduced grids are discussed on a real-word transmission and distribution grid. We produce visualizations of the reduced models through open source libraries and release our reduction algorithms with example code and toy data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TReactMech v4.217

TReactMech couples geomechanical processes (poroelasticity, failure, and inelastic strain) with multiphase nonisothermal flow (derived from TOUGH2) and reactive geochemical transport. At its core is the reactive-transport code TOUGHREACT v4.13. TReactMech is an efficient hybrid parallel simulator, solving the geomechanics using finite elements and MPI/PetSc, the multiphase flow using integrated finite difference and MPI/PETSc, and the reactive chemistry using OpenMP. The advantages of TReactMech are in its multiphase flow capabilities (e.g., supercritical CO2, supercritical water, air) and parallel geomechanics including full 3-D stress tensor, shear and tensile failure, coupled to porosity and permeability changes. It is backwardly compatible with TOUGH2 and TOUGHREACT v4.13, allowing for easier transitions between the codes. TReactMech can be used to simulate many natural and engineered subsurface systems, including geothermal reservoirs, borehole heat exchangers, geologic carbon sequestration, geologic storage of nuclear waste, groundwater resources, weathering, sediment diagenesis, seafloor hydrothermal circulation, hydrofracturing in unconventional reservoirs, and injection/production-induced surface deformation.

Sonnenthal, Eric↗

IDAES-PSE 2.2.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. New features in the 2.2 release include: DiagnosticsToolbox DiagnosticsToolbox (idaes.core.util.model_diagnostics. DiagnosticsToolbox is a new self-guiding toolbox for assisting with diagnosing modeling issues. The toolbox contains a wide range of tools for identifying common modeling issues and conveying these to the user, and more features will be added in the coming months. To try the new toolbox, use the following steps: from idaes.core.util import DiagnosticsToolbox Build an instance of your model Ensure your models has zero degrees of freedom (as best you can) dt = DiagnosticsToolbox(model) dt.report_structural_issues() Follow the prompts Deprecations DegeneracyHunter is being deprecated in favor of the new DiagnosticsToolbox. The features and capabilities of DegeneracyHunter will be moved over to the DiagnositcsToolbox in the coming months. Removal of usage of Pyomo's expr.current due to deprecation upstream. Removed support for radial basis functions in ALAMOpy as these did not work in the current implementation. Those wishing to use radial basis functions should use Pysmo instead. New Capabilities MSContactor model for unit operations involving mass transfer between 2 or more streams, such as membrane, solvent extraction and solids leaching operations. Other Improvements Improved formulation for solubility products with additional parameters for better scaling of terms Better backward compatibility, verification and robustness testing of core models and APIs Added support for Separator models without energy balances

DiagnosticsToolbox↗

IDAES-PSE 2.1.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.1.0 Release Highlights New IDAES Examples Repository Starting with this release, the IDAES examples are developed in the new IDAES/examples repository. Along with many content and usability improvements, the most significant changes are: To install the examples, after installing IDAES, run pip install idaes-examples The idaes get-examples command, previously used for this, has been removed The HTML version is now available at https://idaes-examples.readthedocs.io The previous URL, https://idaes.github.io/examples-pse, will not be updated and may be removed at some point in the future For more details, refer to the resources available at IDAES/examples. Removal of Non-Functional Apps A review of the code in the idaes/apps and idaes/models_extra folders was undertaken, and a number of tools were identified as being outdated or non-functional and no longer supported by their development teams. Due to this, the following tools have been removed: idaes/apps/alamopy_depr (note that the new ALAMOpy interface remains avaialble in idaes/core/surrogates) idaes/apps/helmet idaes/apps/ripe idaes/apps/roundingRegression idaes/models_extra/carbon_capture Pyomo 6.6 This version of IDAES is the first requiring Pyomo 6.6. This version of Pyomo contains multiple internal improvements and refactorings. While for the majority of cases this should have positive or no impact on solvability of IDAES models, we are aware of a small number of models that have been affected as a result of these changes. For more information, refer to the Pyomo 6.6.1 release notes. Other highlights Model Initialization A prototype API for a new approach to initializing IDAES models is now available which makes available some new techniques for initializing models. This is documented in the Initializing Models Reference Guide Modular Properties Framework Support for some transport properties Helmholtz Equation of State properties Better error checking for case where unit models are set to include phase equilibrium but the property package is set to support only a single phase Multi-Stream Contactor model: a new base model for systems involving contacting of two or more streams with mass transfer. This model is intended to be used as the foundation for models such as membrane separators, solvent extraction and other similar processes. This is documented in the Multi-Stream Contactor Reference Guide idaes/models_extra/power_generation report() methods for unit models using Helmholtz equation of state General Code Maintenance Streamlining of dependencies and creation of new optional dependency groupings to support non-core tools General linting of codebase to ensure compliance with most pylint checks Spell checking of all code and doc strings Removal of backward compatibility code for Python 2

IDAES↗

IDAES-PSE 2.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.0.0 Release Highlights Removal of deprecated features from IDAES v1 Update to Pyomo v6.5 – this required a number of updates to support the new NL solver writer and to address some changes in Pyomo Creation of new testing suite for backward compatibility, model robustness and verification More general implementation of the Helmholtz EoS. This brings some new features like standard property diagrams, choice of mass or mole basis, and new state variable options Standardizing names in Heat Exchanger models (breaking change from v2.0.0a2): Control Volumes named hot_side and cold_side Ports names hot_side_inlet, hot_side_outlet, cold_side_inlet and cold_side_outlet Config Blocks names hot_side_config and cold_side_config Config arguments for user provided names for each side: hot_side_name and cold_side_name. Updating Keras surrogate tool to use v1.1 of OMLT New prototype API for model initialization (idaes.core.initialization) The new API uses "Model Initializer" objects instead of class methods, allowing for the definition of multiple initialization routines for a single model A number of common, model agnostic initialization routines have also been defined, including initialization from data, block-decomposition and a general hierarchical approach equivalent to the existing method for common unit models New metadata for thermophysical properties – valid_range This can be used to record the range of values over which a property value can be trusted, such as the range of experimental data used to regress parameters A number of new utility functions have been added to check for properties with values outside the valid range and to set bounds based on this metadata Updated construction of balance expressions in Control Volumes to remove unneeded terms In the past, unneeded terms were added as a constant 0 term, however they will now be dropped entirely from the expression This was necessary due to more strict unit checking in the new Pyomo solver writer which no longer ignores 0 terms Updates to metadata for thermophysical properties to better define known properties and units of measurement This results in more strict enforcement of standard naming for thermophysical and reaction properties Users can still define custom properties, but these must be done explicitly using the define_custom_properties() method instead of being implicitly created by add_property() Updated convergence tester utility tool to support definition of benchmark files (JSON format) and comparison of performance to benchmarks Set default iteration limit for IPOPT in IDAES config to 200 iterations Update scaling of example models to work with new Pyomo NL solver writer Improve testing of extensions and examples infrastructure to avoid need for downloading files Updated distillation column to centralize common functionality and remove a number of Pyomo warnings

IDAES↗

IDAES-PSE 2.5.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.5.0 Release Highlights Upcoming Changes IDAES will be switching to the new Pyomo solver interface in the next release. Whilst this will hopefully be a smooth transition for most users, there are a few important changes to be aware of. The new solver interface uses a different version of the IPOPT writer (“ipopt_v2”) and thus any custom configuration options you might have set for IPOPT will not carry over and will need to be reset. By default, the new Pyomo linear presolver will be activated with ipopt_v2. Whilst are working to identify any bugs in the presolver, it is possible that some edge cases will remain. IDAES will begin deploying a new set of scaling tools and APIs over the next few releases that make use of the new solver writers. The old scaling tools and APIs will remain for backward compatibility but will begin to be deprecated. New Models, Tools and Features New diagnostics check for near-parallel variables and constraints. New diagnostics tools for identifying causes of infeasibility in models. New example for creating a custom model of a liquid-liquid extractor unit operation. Bug Fixes Fixed bug in Gibbs reactor that caused it to appear to have additional spurious degrees of freedom. Fixed bug in the Modular Property Framework that would cause errors when trying to use phase-based material balances with phase equilibria. Fixed bug in Modular Properties Framework that caused errors when initializing models with non-vapor-liquid phase equilibria. Testing and Robustness Deployed the IDAES Diagnostics Toolbox to confirm that there are no structural or numerical issues in the core model libraries. Additional robustness tests for core model, and some associated improvements in the converge tester class. Fixed a number of issues that were causing unexpected warnings to be emitted during testing. Deprecations and Removals Removed examples for RIPE tool which has not been supported for a number of releases.

AS↗