Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balanced Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simple Cell Balance Circuit

A method has been developed for continuous cell voltage balancing for rechargeable batteries (e.g. lithium ion batteries). A resistor divider chain is provided that generates a set of voltages representing the ideal cell voltage (the voltage of each cell should be as if the cells were perfectly balanced). An operational amplifier circuit with an added current buffer stage generates the ideal voltage with a very high degree of accuracy, using the concept of negative feedback. The ideal voltages are each connected to the corresponding cell through a current- limiting resistance. Over time, having the cell connected to the ideal voltage provides a balancing current that moves the cell voltage very close to that ideal level. In effect, it adjusts the current of each cell during charging, discharging, and standby periods to force the cell voltages to be equal to the ideal voltages generated by the resistor divider. The device also includes solid-state switches that disconnect the circuit from the battery so that it will not discharge the battery during storage. This solution requires relatively few parts and is, therefore, of lower cost and of increased reliability due to the fewer failure modes. Additionally, this design uses very little power. A preliminary model predicts a power usage of 0.18 W for an 8-cell battery. This approach is applicable to a wide range of battery capacities and voltages.

Johnson, Steven D.↗

Seasonal stabilization effects slowed the greening of the Northern Hemisphere over the last two decades

Rising atmospheric CO₂ and warming spring temperatures increase vegetation growth and the terrestrial carbon sink. However, drought, heat stress, phenology, and resource limitations may stabilize or limit theses projected increases. We investigate the balance between these amplifying and stabilizing ecological factors by asking whether enhanced early-season growth leads to continued late-season growth. Using the Moderate Resolution Imaging Spectroradiometer (MODIS) leaf area index (LAI) dataset, we identify three seasonal growth patterns based on early- and peak-season positive LAI anomalies: (1) amplification, where late-season LAI anomalies exceed earlier ones; (2) weak stabilization, where late-season anomalies remain similar or slightly lower; and (3) strong stabilization, where late-season anomalies become negative. Weak and strong stabilization events dominate across 67% and 26% of Northern Hemisphere ecosystems above 30°N, respectively. The absence of any trend in amplifying or stabilizing events suggests stabilizing factors seasonally offset CO₂ and temperature-induced spring greening. Terrestrial biosphere models underestimate strong stabilization and overestimate amplification events. This inconsistency arises from the models’ underestimation late-season LAI sensitivity to precipitation in water-limited regions; overlook negative legacy effects of early enhanced LAI on late-season soil moisture via evapotranspiration losses in energy-limited regions. Our findings suggest water/heat stress and resource limitations limit greening and the land carbon sink.

Zhang, Wen↗

Amplifier Output Power, Gain, Efficiency, and Bandwidth: A Comparative Study of GaN HEMT MMIC Multi-Stage Power Amplifiers versus Distributed Power Amplifiers

In this paper we present first, the results of a study conducted to investigate the microwave performance of a wideband (25-31 GHz) GaN MMIC distributed high power amplifier (HPA). Second, we compare and contrast the above performance with that of an alternate architecture that relies on two HPAs to provide contiguous 25-31 GHz coverage. The two HPAs operate across 25-28 GHz and 27-31 GHz, respectively, and can be switched in and out depending on the need at any given time. The parameters investigated includes the output power, gain, power added efficiency, bandwidth, RMS error vector magnitude for offset-QPSK, 8PSK, 16APSK, and 32 APSK waveforms, 3rd-order intermodulation distortion products, noise figure, and single sideband phase noise.

MMIC↗

High stability buffered phase comparator

A low noise RF signal phase comparator comprised of two high stability driver buffer amplifiers driving a double balanced mixer which operate to generate a beat frequency between the two RF input signals coupled to the amplifiers from the RF sources is described. The beat frequency output from the mixer is applied to a low noise zero crossing detector which is the phase difference between the two RF inputs. Temperature stability is provided by mounting the amplifiers and mixer on a common circuit board with the active circuit elements located on one side of a circuit board and the passive circuit elements located on the opposite side. A common heat sink is located adjacent the circuit board. The active circuit elements are embedded into the bores of the heat sink which slows the effect of ambient temperature changes and reduces the temperature gradients between the active circuit elements, thus improving the cancellation of temperature effects. The two amplifiers include individual voltage regulators, which increases RF isolation.

Adams, W. A.↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A millimeter-wave pumped X-band uncooled parametric amplifier.

GaAs Schottky barrier varactors with a cutoff frequency of 800 GHz are used in a balanced diode-type parametric amplifier operating with a signal frequency at 7.5 GHz. The room-temperature parameters of the amplifier are a gain of 15 dB, a bandwidth of 500 MHz, and an excess noise temperature of 63 K (a noise figure of 0.86 dB).

Dickens, L. E.↗

Liquid crystal polymer receiver modules for electron cyclotron emission imaging on the DIII-D tokamak

A new generation of millimeter-wave heterodyne imaging receiver arrays has been developed and demonstrated on the DIII-D electron cyclotron emission imaging (ECEI) system. Improved circuit integration, improved noise performance, and enhanced shielding from out-of-band emission are made possible by using advanced liquid crystal polymer (LCP) substrates and monolithic microwave integrated circuit (MMIC) receiver chips. This array exhibits ~15 dB additional gain and >30× reduction in noise temperature compared to previous generation ECEI arrays. Each LCP horn-waveguide module houses a 3 × 3 mm GaAs MMIC receiver chip, which consists of a low noise millimeter-wave preamplifier, balanced mixer, and IF amplifier together with a local oscillator multiplier chain driven at ~12 GHz. A proof-of-principle partial LCP instrument with 5 poloidal channels was installed on DIII-D in 2017, with a full proof-of-principle system (20 poloidal × 8 radial channels) installed and commissioned in early 2018. The enhanced shielding of the LCP modules is seen to greatly reduce the sensitivity of ECEI signals to out-of-band microwave noise which has plagued previous ECEI studies on DIII-D. As a result, the LCP ECEI system is expected to be a valuable diagnostic tool for pedestal region measurements, focusing particularly on electron temperature evolution during edge localized mode bursting.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved insertion-loss tester

An improved test method accurately measures the insertion loss of RF components while avoiding amplifier drift. Currents are balanced across a bridge transformer with shorted probes and then with each component to be tested. Differences in adjustments indicate the loss.

Finnie, C. J.↗

Circuit suppresses spurious sidebands

Circuitry requires modulated subcarrier to be split, part going to a phase modulator, and part going to a new circuit which utilizes a square law detector, a balanced mixer, and an amplifier to remove spurious sidebands. A summer recombines the two outputs, and final signal no longer includes spures.

Ready, P. J.↗

Models for X-Ray Emission from Isolated Pulsars

A model is proposed for the observed combination of power-law and thermal X-rays from rotationally powered pulsars. For gamma-ray pulsars with accelerators very many stellar radii above the neutron star surface, 100 MeV curvature gamma-rays from e(-) or e(+) flowing starward out of such accelerators are converted to e1 pairs on closed field lines all around the star. These pairs strongly affect X-ray emission from near the star in two ways. (1) The pairs are a source of synchrotron emission immediately following their creation in regions where B approx. 10(exp 10) G. This emission, in the photon energy range 0.1 keV less than E(sub X) less than 5 MeV, has a power-law spectrum with energy index 0.5 and X-ray luminosity that depends on the back-flow current, and is typically approx. 10(exp 33) ergs/ s. (2) The pairs ultimately a cyclotron resonance "blanket" surrounding the star except for two holes along the open field line bundles which pass through it. In such a blanket the gravitational pull on e(+,-) pairs toward the star is balanced by the hugely amplified push of outflowing surface emitted X-rays wherever cyclotron resonance occurs. Because of it the neutron star is surrounded by a leaky "hohlraum" of hot blackbody radiation with two small holes, which prevents direct X-ray observation of a heated polar cap of a gamma-ray pulsar. Weakly spin modulated radiation from the blanket together with more strongly spin-modulated radiation from the holes through it would then dominate observed low energy (0.1-10 keV) emission. For non-y-ray pulsars, in which no such accelerators with their accompanying extreme relativistic back-flow toward the star are expected, optically thick e1 resonance blankets should not form (except in special cases very close to the open field line bundle). From such pulsars blackbody radiation from both the warm stellar surface and the heated polar caps should be directly observable. In these pulsars, details of the surface magnetic field evolution, especially of polar cap areas, become relevant to observations. The models are compared to X-ray data from Geminga, PSR 1055-52, PSR 0656+14, PSR 1929+10, and PSR 0950+08.

Wang, F. Y.-H.↗

Charge integration successive approximation analog-to-digital converter for focal plane applications using a single amplifier

An analog-to-digital converter for on-chip focal-plane image sensor applications. The analog-to-digital converter utilizes a single charge integrating amplifier in a charge balancing architecture to implement successive approximation analog-to-digital conversion. This design requires minimal chip area and has high speed and low power dissipation for operation in the 2-10 bit range. The invention is particularly well suited to CMOS on-chip applications requiring many analog-to-digital converters, such as column-parallel focal-plane architectures.

Zhou, Zhimin↗

Thermal Transitions in Perfluorosulfonated Ionomer Thin-Films

Thin perfluorosulfonated ion-conducting polymers (PFSI ionomers) in energy-conversion devices have limitations in functionality attributed to confinement-driven and surface-dependent interactions. This study highlights the effects of confinement and interface-dependent interactions of PFSI thin-films by exploring thin-film thermal transition temperature (T T ). Change in T T in polymers is an indicator for chain relaxation and mobility with implications on properties like gas transport. Here, this work demonstrates an increase in T T with decreasing PFSI film thickness in acid (H + ) form (from 70 to 130 °C for 400 to 10 nm, respectively). In metal cation (M + ) exchanged PFSI, T T remained constant with thickness. Results point to an interplay between increased chain mobility at the free surface and hindered motion near the rigid substrate interface, which is amplified upon further confinement. This balance is additionally impacted by ionomer intermolecular forces, as strong electrostatic networks within the PFSI-M + matrix raises T T above the mainly hydrogen-bonded PFSI-H + ionomer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of parallel flow on resonant layer responses in high beta plasmas

Abstract Resonant layers in a tokamak respond to non-axisymmetric magnetic perturbations by amplifying the mode amplitude and balancing the plasma rotation through magnetic reconnection and force balance, respectively. This resonant response can be characterized by local layer parameters and especially by a single quantity in the linear regime, the so-called inner-layer Δ. The computation of Δ under two-fluid drift-MHD formalism has been progressed by reducing the order of the system in the phase space, where the shielding current is approximated as being only carried by electrons, a posteriori . In this study, we relax the approximation and compute Δ accounted for by the parallel flow associated with the ion shielding current. The posteriori is numerically verified in great agreement with the original SLAYER developed in a previous paper (J.-K. Park 2022 Phys. Plasmas 29 072506). Extending the resonant layer response theory to high β plasmas, our research findings answer two important questions: how the parallel flow influences the resonant layer response and why the parallel flow effect appears in high β plasmas. The complicated plasma compression in high β regime allows the parallel flow response to give rise to the ion shielding current, which not only shifts the zero-crossing condition of the ExB flow but also enhances the field penetration threshold. Technically, the Riccati matrix transformation method is adapted to handle the numerical stiffness due to the increased order of the system. The high fidelity of this numerical method makes use of further extension of the model to higher-order systems to take other physical phenomena into account. This work is envisaged to predict the resonant layer response under high β fusion reactor conditions.

Lee, Yeongsun (ORCID:000000034474416X)↗

Broadband Active Antenna

Effective area of search coil increased. Input impedance presented by operational amplifier and associated components nearly balances out impedance of search coil. Fluctuations in ambient magnetic field induce large currents in search coil.

Sutton, John F.↗

Time-Varying Ice Sheet Mask: Implications on Ice-Sheet Mass Balance and Crustal Uplift

Mass-balance estimates of the polar ice sheets presently rely on static ice masks to identify the area under investigation. However, the vintage of available ice masks can differ by more than a decade and the resolution of the imagery used to delineate ice extent can differ by an order of magnitude, despite evidence of ongoing ice-sheet retreat. We show that using a fine resolution, time-varying ice mask significantly improves mass-balance estimates of the northwestern sector of the Greenland Ice Sheet and affects interpretation of local crustal uplift. Accounting for ice margin retreat using a time-varying ice mask between 2003–2015 results in 1.0–6.8% less ice-sheet mass loss relative to assuming one of several existing static ice masks. This indicates that mass-balance estimates that use a static ice mask will progressively overestimate mass loss where the ice sheet is predominantly retreating, meaning a negative bias on mass-balance. This trend is anticipated to be amplified in a future warming scenario unless updated ice masks are incorporated. For altimetry-derived mass-balance estimates, this ice-mask induced bias approaches the magnitude of the ice-sheet-wide uncertainty presently associated with spatiotemporal variability in modeled firn compaction. Further, at five GNET stations, the ice-mask-induced bias is equivalent to 5–15% of the modeled uplift due to elastic deformation. Given present and projected negative trends in Greenland Ice Sheet mass-balance and areal extent, we conclude that studies of its mass-balance should begin incorporating dynamic, periodically updated, fine-resolution ice masks. This methodological refinement will reduce bias in estimates of both ice-sheet mass-balance and crustal uplift.

Kristian K. Kjeldsen↗

Power balancing a multibeam laser

Multibeam lasers often require an output beam balance that specifies the degree of simultaneity of the laser output energy, instantaneous power, or instantaneous irradiance (power per unit area). Here, this work describes the general problem of balancing a multibeam laser. Specific techniques used to balance the output power of the 60-beam pulsed OMEGA Laser System are discussed along with a measured reduction of beam-to-beam imbalance. In particular, the square-pulse distortion induced by a simple saturating amplifier operating with its output at some fraction of its saturation fluence is derived, and a method to exchange gain between saturated amplifiers in a single beam that have different saturation fluences to adjust balance is described.

47 OTHER INSTRUMENTATION↗

Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

Moreno, Michelle↗

Thrust Stand for Electric Propulsion Performance Evaluation

An electric propulsion thrust stand capable of supporting thrusters with total mass of up to 125 kg and 1 mN to 1 N thrust levels has been developed and tested. The mechanical design features a conventional hanging pendulum arm attached to a balance mechanism that transforms horizontal motion into amplified vertical motion, with accommodation for variable displacement sensitivity. Unlike conventional hanging pendulum thrust stands, the deflection is independent of the length of the pendulum arm, and no reference structure is required at the end of the pendulum. Displacement is measured using a non-contact, optical linear gap displacement transducer. Mechanical oscillations are attenuated using a passive, eddy current damper. An on-board microprocessor-based level control system, which includes a two axis accelerometer and two linear-displacement stepper motors, continuously maintains the level of the balance mechanism - counteracting mechanical %era drift during thruster testing. A thermal control system, which includes heat exchange panels, thermocouples, and a programmable recirculating water chiller, continuously adjusts to varying thermal loads to maintain the balance mechanism temperature, to counteract thermal drifts. An in-situ calibration rig allows for steady state calibration both prior to and during thruster testing. Thrust measurements were carried out on a well-characterized 1 kW Hall thruster; the thrust stand was shown to produce repeatable results consistent with previously published performance data.

Markusic, T. E.↗