Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Two-Year Mortality After Angioplasty of the Femoro-Popliteal Artery with Uncoated Balloons and Paclitaxel-Coated Balloons—A Pooled Analysis of Four Randomized Controlled Multicenter Trials

Purpose: In view of a recent meta-analysis reporting increased mortality following angioplasty with paclitaxel-coated devices in peripheral arteries, we performed a patient-level 2-year mortality analysis based on pooled original data of four randomized controlled trials (THUNDER, FEMPAC, PACIFIER and CONSEQUENT). Methods and Results: Clinical data of four randomized controlled trial were pooled to assess 2-year mortality following paclitaxel-coated balloon (PCB) angioplasty compared to angioplasty without paclitaxel (control group). A logistic regression model was applied to identify potential predictors of mortality. At two years, 13 of 185 (7.0%) patients had died in the control group and 16/184 (8.7%) in the PBC group, p = 0.55. Kaplan–Meier analysis revealed no significant difference from all-cause death at 2 years (log rank p = 0.54). Causes of death were well balanced between the groups with no pattern or trend in favour of any specific causes in the PBC group. Logistic regression revealed that treatment groups (controls or PBC) were not a predictor of 2-year mortality. The only predictor for mortality was patient age ≥ 75 years. The delivered paclitaxel doses per patient were not significantly different in patients that died and those who did not die during the 24-month follow-up (5.300 ± 4.224 μg vs. 6.248 ± 4.629 μg, p = 0.433). Conclusions: Based on original patient-level data of four pooled randomized controlled trials, we found no increase in 2-year mortality in patients treated with PCB compared to control patients treated with uncoated balloons. Causes of death were well balanced between PCB and control patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ballooning modes localized near the null point of a divertor

The stability of ballooning modes localized to the null point in both the standard and snowflake divertors is considered. Ideal magnetohydrodynamics is used. A series expansion of the flux function is performed in the vicinity of the null point with the lowest, non-vanishing term retained for each divertor configuration. The energy principle is used with a trial function to determine a sufficient instability threshold. It is shown that this threshold depends on the orientation of the flux surfaces with respect to the major radius with a critical angle appearing due to the convergence of the field lines away from the null point. When the angle the major radius forms with respect to the flux surfaces exceeds this critical angle, the system is stabilized. Further, the scaling of the instability threshold with the aspect ratio and the ratio of the scrape-off-layer width to the major radius is shown. It is concluded that ballooning modes are not a likely candidate for driving convection in the vicinity of the null for parameters relevant to existing machines. However, the results place a lower bound on the width of the heat flux in the private flux region. To explain convective mixing in the vicinity of the null point, new consideration should be given to an axisymmetric mixing mode [W. A. Farmer and D. D. Ryutov, Phys. Plasmas 20, 092117 (2013)] as a possible candidate to explain current experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar cell calibration facility validation of balloon flight data: A comparison of shuttle and balloon flight results

The Solar Cell Calibration Facility (SCCF) experiment was designed and built to evaluate the effect of the Earth's upper atmosphere on the calibration of solar cell standards. During execution of the experiment, a collection of carefully selected solar cells was flown on the shuttle, and reflown on a high-altitude balloon, then their outputs were compared. After correction to standard temperature and intensity values of 28 C and an Earth-Sun distance of 1 AU, the solar cell outputs during the two flights were found to be identical. The conclusion is therefore that the high-altitude balloon flights are very good vehicles for calibrating solar cells for use as space flight reference standards.

Anspaugh, B. E.↗

Pseudochaotic poloidal transport in the laminar regime of the resistive ballooning instabilities

In toroidal geometry, and prior to the establishment of a fully developed turbulent state, the so-called topological instability of the pressure-gradient-driven turbulence is observed. In this intermediate state, a narrow spectral band of modes dominates the dynamics, giving rise to the formation of isosurfaces of electric potential with a complicated topology. Since ExB advection of tracer particles takes place along these isosurfaces, their topological complexity affects the characteristic features of radial and poloidal transport dramatically. In particular, they both become strongly nondiffusive and non-Gaussian. Since radial transport determines the system confinement properties and poloidal transport controls the equilibration dynamics (on any magnetic surface), the development of nondiffusive models in both directions is thus of physical interest. In previous work, a fractional model to describe radial transport was constructed by the authors. In this contribution, recent results on periodic fractional models are exploited for the construction of an effective model of poloidal transport. Numerical computations using a three-dimensional reduced magnetohydrodynamic set of equations are compared with analytical solutions of the fractional periodic model. It is shown that the aforementioned analytical solutions accurately describe poloidal transport, which turns out to be superdiffusive with index {alpha}=1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NASA Balloon Technology Activities

The National Aeronautics and Space Administration (NASA) Balloon Program technology development efforts are fundamental to improving the capabilities of the balloon systems, better understanding of the flight dynamics, and to support the science missions throughout the next decade. Building on the foundations of the 20-year research and development program, a technology roadmap has been generated which identifies specific areas of interest to NASA and the vision of future developments. The major components of the roadmap are: vehicle systems, ballooncraft systems, operational and safety support systems, and planetary vehicles. Within each of these major components, technologies are targeted that will provide both better understanding and foster advancements. The Program's technology thrust areas are directed both in broad efforts that touch on a number of the major components as well as specific tasks that address elements within a specific component. Advances in vehicle systems have focused on producing better balloon designs. This is being attempted through the use of improved inputs into the ba!loon des@ process. Central to this is an increasing the understanding of materials used to fabricate balloons. Testing techniques have been improved with better bi-axial characterization of the balloon materials. More realistic radiative properties of the balloon films and components have also been made. Analytical assessments of the balloon designs are also key in improving balloon designs. These analytical assessments have been accomplished using improving analysis tools and an increased understanding of the float environment. Details of these improvements will be presented. To help improve the operational and flight safety of the balloons, improved flight performance predictions have been made using new analytical tools as well as incorporating the increased understanding of the float environment. These two have combined to allow for improved post-flight balloon performance correlations. A potential to significantly improve the potential safety of a long duration flight can be accomplished using some form of a trajectory modification system. An overview of the development efforts for a trajectory modification system will be presented. A number of efforts will be presented that are focused on the improvement of the ballooncraft systems. Planetary ballooning activities have benefited from a number of separate but related technology advancements made by the NASA Balloon Program's technology developments. The tools, techniques, and advancements made for balloon design and balloon analysis are directly applicable to the processes to develop planetary balloons for either Mars or Venus. An overview of the NASA Balloon Program's role in these efforts and testing will be presented. The technology roadmap, as well as specific projects and recent advancements, will be presented. This overview will demonstrate the technology advancements made by the NASA Balloon Program are focusing on leading balloon developments into the future.

Fairbrother, Debora A.↗

Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The NASA Balloon Program: Implementing a New Flight Program for the Future

The U.S. National Aeronautics and Space Administration (NASA) Balloon Program continues to support the scientific community providing enhanced capabilities across a spectrum of balloon related disciplines. Long Duration Ballooning (LDB) continues to be a prominent element of the program with a mission model of a two flight campaign in each the Northern and Southern Hemispheres per year. A new LDB endurance record was achieved in Antarctica with the LDB/CREAM mission. Both polar and mid-latitude LDB capabilities continue to be on-going operational elements of the flight program. The Swedish Space Corporation/Esrange and the National Aeronautics and Space Administration (NASA) inaugurated a joint European/U.S. capability for LDB balloon flights from Sweden to Canada in June 2005. This will complement the NASA/U.S. National Science Foundation Office of Polar Programs achievement of more than a decade of successful long-duration flights around Antarctica. Most of Antarctic flights have flown one time around the South Pole in 8-20 days using conventional (zero differential pressure) balloons. One flight went twice around in 31 days and another went three times around in 42 days using conventional balloons. Balloon technology efforts have continued to broaden in scope and new plans for activities to provide advancements have been initiated. A new balloon volume record was established with the successful flight of a 1,700,000 m3 volume zero-pressure balloon. The capability to fly a 700 kg payload (200 kg science instrument) to 160,000 ft has also been demonstrated. A new super-pressure (constant volume) balloon is currently under development for future flights of 60 - 100 day at any latitude. The Ultra-Long Duration Balloon (ULDB) project for the development of a 100-day duration balloon capability has been progressing with additional ground and flight tests having been conducted. The Program has also continued to introduce new technology and improvements into flight systems, ground systems and operational techniques. An overview of the various aspects of the NASA Balloon Program will be presented as well as the outlook for the future.

Pierce, David L.↗

Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumor enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-guided method for TLD-based in vivo rectal dose verification with endorectal balloon in proton therapy for prostate cancer

Purpose: To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. Methods: TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markers were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. Results: A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Conclusions: Our results show that image-guided TLD-based in vivo dosimetry for rectal dose verification can be perfomed reliably and reproducibly for proton therapy in prostate cancer.

60 APPLIED LIFE SCIENCES↗

Solar Hot Air Balloons for Terrestrial and Planetary Atmospheres

The first solar hot air balloon was constructed in the early 1970s (Besset, 2016). Over the following decades the Centre National d'Etudes Spatiales (CNES) developed the Montgolfiere Infrarouge (MIR) balloon, which flew on solar power during the day and infrared radiation from the Earth's surface at night (Fommerau and Rougeron, 2011). The balloons were capable of flying for over 60 days and apparently reached altitudes of 30 km at least once (Malaterre, 1993). Solar balloons were the subject of a Jet Propulsion Laboratory study that performed test flights on Earth (Jones and Wu 1999) and discussed their mission potential for Mars, Jupiter, and Venus (Jones and Heun, 1997). The solar balloons were deployed from the ground and dropped from hot air balloons; some were altitude controlled by means of a remotely-commanded air valve at the top of the envelope. More recently, solar balloons have been employed for infrasound studies in the lower stratosphere (see Table 1). The program began in 2015, when a prototype balloon reached an altitude of 22 kilometers before terminating just prior to float (Bowman et al., 2015). An infrasound sensor was successfully deployed on a solar balloon during the 2016 SISE/USIE experiment, in which an acoustic signal from a ground explosion was captured at a range of 330 km (Anderson et al. 2018; Young et al. 2018). This led to the launch of a 5-balloon infrasound network during the Heliotrope experiment (Bowman and Albert, 2018). The balloons were constructed by the researchers themselves at a materials of less than $50 per envelope.

14 SOLAR ENERGY↗

Concepts for autonomous flight control for a balloon on Mars

Balloons operating as airborne rovers have been suggested as ideal candidates for early exploration of the Martian surface. An international study team composed of scientists from the U.S.S.R., France, and the U.S.A. is planning the launching in 1994 of a balloon system to fly on Mars. The current likely design is a dual thermal/gas balloon that consists of a gas balloon suspended above a solar-heated thermal balloon. At night, the thermal balloon provides no lift, and the balloon system drifts just above the Martian surface; the lift of the gas balloon is just sufficient to prevent the science payload from hitting the ground. During the day, the balloon system flies at an altitude of 4 to 5 kilometers, rising due to the added lift provided by the thermal balloon. Over the course of a single Martian day, there may be winds in several directions, and in fact it can be expected that there will be winds simultaneously in different directions at different altitudes. Therefore, a balloon system capable of controlling its own altitude, via an autonomous flight control system, can take advantage of these different winds to control its direction, thereby greatly increasing both its mission utility and its longevity.

Heinsheimer, Thomas F.↗

An Overview of the NASA Sounding Rockets and Balloon Programs

The U.S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a combined total of approximately fifty to sixty missions per year in support of the NASA scientific community. These missions are provided in support of investigations sponsored by NASA'S Offices of Space Science, Life and Microgravity Sciences & Applications, and Earth Science. The Goddard Space Flight Center has management and implementation responsibility for these programs. The NASA Sounding Rockets Program has continued to su,pport the science community by integrating their experiments into the sounding rocket payload and providing the rocket vehicle and launch operations necessary to provide the altitude/time required obtain the science objectives. The sounding rockets continue to provide a cost-effective way to make in situ observations from 50 to 1500 km in the near-earth environment and to uniquely cover the altitude regime between 50 km and 130 km above the Earth's surface, which is physically inaccessible to either balloons or satellites. A new architecture for providing this support has been introduced this year with the establishment of the NASA Sounding Rockets Contract. The Program has continued to introduce improvements into their operations and ground and flight systems. An overview of the NASA Sounding Rockets Program with special emphasis on the new support contract will be presented. The NASA Balloon Program continues to make advancements and developments in its capabilities for support of the scientific ballooning community. Long duration balloon (LDB) is a prominent aspect of the program with two campaigns scheduled for this calendar year. Two flights are scheduled in the Northern Hemisphere from Fairbanks, Alaska, in June and two flights are scheduled from McMurdo, Antarctica, in the Southern Hemisphere in December. The comprehensive balloon research and development (R&D) effort has continued with advances being made across the spectrum of balloon related disciplines. As a result of these technology advancements a new ultra long duration balloon project (ULDB) for the development of a 100- day duration balloon capability has been initiated. The ULDB will rely upon new balloon materials and designs to accomplish its goals. The Program has also continued to introduce new technology and improvements into flights systems, ground systems and operational techniques. An overview of the various aspects of the NASA Balloon Program will be presented.

Flowers, Bobby J.↗

Global Assimilation of Loon Stratospheric Balloon Observations

Accurate analyses of stratospheric winds are important for determining realistic constituent transport and providing improved diagnostic studies and forecasts of the stratosphere. This study examines impacts on global meteorological analyses resulting from using winds derived from Loon superpressure balloons in the lower stratosphere (hereafter Loon winds) as additional input observations to the Goddard Earth Observing System (GEOS) data assimilation system. To fully investigate the impacts of assimilating the Loon winds, two steps are taken: (1) comparison of the GEOS analysis winds with Loon winds (Control experiment) and (2) examination of the impacts of assimilating the Loon winds into the GEOS data assimilation system (Loon experiment). The time period selected is June–August 2014 when over 150 Loon balloons were launched, mainly in the Southern Hemisphere. In the middle latitudes, the Loon winds and Control winds agree well (Loon balloon zonal wind observation minus forecast, O − F, root‐mean‐square (RMS) values of ~2.75 m/s) and assimilating the Loon winds has a small impact (O − F RMS values unchanged). In the tropics, the Loon observations and Control analysis winds differ more than in middle latitudes (zonal wind O − F RMS ~3.75 m/s) and assimilating the Loon winds improves the zonal wind O − F RMS by ~1 m/s. In selected cases where the Loon observations and Control analysis differ greatly (O − F RMS values greater than 10 m/s), assimilating Loon winds significantly decreases the zonal wind O − F RMS by 5 m/s. These decreases in O − F RMS values show that the 6‐hr forecasts are improved at the Loon balloon observation locations. While satellites routinely measure Earth's global temperatures from space, in situ wind measurements are relatively scarce, consisting mainly of a network of ground‐based weather balloons. Since only a limited number of the weather balloons even reach stratospheric altitudes, there is a need for additional stratospheric observations. One option for addition wind information is the use of experimental superpressure balloons (SPBs). SPBs can remain in the stratosphere for many months traveling with the winds and hence, by reporting their changing positions, providing in situ wind observations. These SPBs experiments are generally limited in terms of time period and number of balloons. However, over the past few years Loon has been launching hundreds of SPBs (hereafter called Loon balloons) providing a more consistent set of observations of wind in the stratosphere. Here we assimilate some of the Loon balloon winds into the NASA GEOS global data assimilation system. The data assimilation system combines all observations with an atmospheric model to produce global analysis of winds and temperatures. Results show that including the Loon balloon wind information noticeably affects the global analysis as well as forecasts with the largest impact in the tropics. These results provide direction to future model and analysis improvements.

L. Coy↗

Reduction of prostate intrafraction motion using gas-release rectal balloons

Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemosaturation Percutaneous Hepatic Perfusion (CS-PHP) with Melphalan: Evaluation of 2D-Perfusion Angiography (2D-PA) for Leakage Detection of the Venous Double-Balloon Catheter

Purpose: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) for detecting leakage of the double-balloon catheter used for chemosaturation percutaneous hepatic perfusion (CS-PHP). Materials and Methods: Overall, 112 CS-PHP (09/2015-09/2018) in 52 patients were retrospectively screened for leakage alongside the double-balloon catheter on standard venograms. Finally, 18 procedures with visually detected leakage were included. Fifteen consecutive procedures without leakage served as control. To evaluate 2D-PA for leakage detection, the acquired digital subtraction venograms were post-processed. For each balloon, two different target ROIs were evaluated to assess a possible impact of localization and shape of the ROIs. Time to peak (TTP), peak density (PD), area under the curve (AUC), and ratios of target ROI/reference ROIs (PD{sub tROI}/PD{sub REF}; AUC{sub tROI}/AUC{sub REF}; and TTP{sub tROI}/TTP{sub REF}) were calculated. Results: Leakages were located as follows: 15/18 cranial and 3/18 caudal. At the cranial balloon both ROIs showed a significant decrease in PD{sub tROI}/PD{sub REF} and AUC{sub tROI}/AUC{sub REF} (ROI1: p < 0.0001; p < 0.0001; ROI2: p < 0.0001; p < 0.0001) and a significant increase in TTP{sub tROI}/TTP{sub REF} (ROI1: p = 0.0009; ROI2: p = 0.0003) after double-balloon correction. Following balloon adjustment, the 2D-PA ratios (PD and AUC) of the tested ROIs differed significantly (p < 0.05). The inter-individual comparison of the 2D-PA parameters of the group with leakage before balloon correction and the non-leakage group showed significantly different 2D-PA values for the cranial balloon in both ROIs (p < 0.05). No significant differences were found for the caudal balloon. Conclusion: 2D-PA provides a feasible tool for detecting leakages alongside the cranial portion of the double-balloon catheter used in CS-PHP. The shape and position of the ROIs used to assess perfusion and flow have an impact on the measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗