Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balloon-borne Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV-nucleon

A balloon-borne detector system for extending the study of cosmic ray composition to the energy region beyond 100 GeV/nucleon is described. The instrument incorporates an ionization calorimeter and a gas Cherenkov counter filled with freon for the determination of energies, and a charge module, consisting of scintillation and a lucite Cherenkov counter, for determining the charge of the incoming particle. The scintillators were utilized to determine the position of the incoming particle in addition to its charge. The characteristics of these detectors with respect to resolution, and the methods employed in laboratory calibration, cross-checks with flight data and actual performance in the flights are described in detail. Monte Carlo simulation of the ionization calorimeter and comparison of the response of the calorimeter and gas Cherenkov counter for complex nuclei was used to convert the observed calorimeter signal to absolute energy in a consistent manner.

Arens, J. F.↗

Ultraviolet stellar spectrophotometry from a balloon platform

A 40 centimeter diameter aperture, balloon-borne telescope and ultraviolet spectrometer is described and selected scientific results are briefly reviewed. The general configuration of the 0.4 angstrom resolution instrument is shown and the utilization of servo-controlled secondary mirror, image dissector detector, and special mirror coatings are discussed. An outlook for astronomical research in the mid-ultraviolet from balloon-borne telescopes is presented together with future development plans for JSC's balloon-borne payload.

Kondo, Y.↗

Balloon-borne package temperature controller

Simple, inexpensive, lightweight enclosure traps upward long wave radiation of earth while reflecting harsh solar radiation in upper atmosphere. It warms enclosed instruments in cold regions and protects them from overheating during the day. Device can be attached to balloon system without any changes in experimental design.

Schach, M.↗

Evidence for detection of 1-10 MeV emission from the Taurus region in 1971 August

Results are reported for three observations of the Crab Nebula with a balloon-borne actively collimated NaI detector over the energy range from 0.2 to 10 MeV. Possible changes in instrument performance and environmental background levels during the balloon flights are investigated, and fits for source strength are made over four broad energy channels. X-ray power-law spectra and pulsed-flux fractions are determined for both the Crab Nebula and its pulsar, NP 0532. A statistically significant flux greatly in excess of the power law was detected above 1 MeV during one flight; this flux, which has declined by at least a factor of 4 or 5 at the times of more recent observations, is assumed to be real and is attributed to the nebula.

Gruber, D. E.↗

High resolution stellar spectroscopy in the balloon ultraviolet

The JSC/SRL Balloon-borne Ultraviolet Stellar Spectrometer (BUSS) comprises a 40 cm telescope, an echelle spectrograph and a SEC Vidicon detector. Operating at an altitude of 40 km this instrument provides spectra of stars with 0.1 A resolution in the 2000-3400 A region. Observations made on 19 May 1976, are discussed.

De Jager, C.↗

Orientation measurement for balloon-borne telescopes

A description is given of a simple and reliable system for recording information which in a postflight analysis will make it possible to determine the orientation of the telescope beam for any arbitrary time during the flight. The system provides a continuous in-flight photographic reference to the pole star. Questions of system design are considered and instrumental details are presented. Attention is also given to aspects of calibration and postflight analysis.

Joseph, R. D.↗

Atmospheric monitoring using heterodyne detection techniques

Both passive and active remote-monitoring instruments using discretely tunable infrared gas lasers and heterodyne receivers have been used for measurements of ozone and other trace constituents in the atmosphere. A ground-based solar heterodyne radiometer has been used in discrete spectral regions near 9.5 microns to measure altitude profiles of ozone in both the troposphere and stratosphere. Results indicate that this technique shows promise in providing calibration points for earth-orbiting ozone-measurement instruments. An airborne laser absorption spectrometer has been used to measure tropospheric ozone in two series of flights during the winter and spring of 1977, and these operations are described. Plans are also in progress to fly a balloon-borne heterodyne radiometer during the fall of 1977 in order to measure stratospheric trace species.

Menzies, R. T.↗

Radiometric measurement of stratospheric HCl

On March 17, 1976, the atmospheric absorption of solar infrared radiation at sunset was measured by a balloon-borne pressure modulator, whose major feature was a cell containing gaseous HCl, through which the incoming radiation passed. The side-band:wide-band ratio which is related to the amount of atmospheric HCl in the path between the instrument and the sun, was also measured. The vertical mixing ratio profile for gaseous HCl for the altitude range 16-39 km, was derived from the data by using a computer model. The shape of the profile implies that the major source of HCl in the stratosphere is around 32 km. The importance of this profile in determining the effects of man-made chlorine compounds on atmospheric ozone is stressed.

Eyre, J. R.↗

Balloon-based measurements of the cosmic background radiation

A balloon-borne liquid-helium-cooled spectrometer was developed and flown to measure the cosmic background radiation in the 3- to 18-per-cm region. It features a cooled horn antenna, a polarizing Michelson interferometer, and a germanium bolometer. These design features and the performance of the instrument are discussed.

Mather, J. C.↗

Search for gamma ray bursts with coincident balloon flights

A search was conducted for cosmic gamma ray bursts of small size and of sufficient frequency of occurrence to be detected during a one day observation program. Two similar detectors, successfully balloon-borne from launch sites in South Dakota and Texas, achieved about 20 hours of simultaneous operation at several millibars atmospheric depth, with continuous separation of over 1,500 km. Fluctuations of the counting rates of less than 150 keV photons with temporal structures from microseconds to several minutes were compared in order to detect coincident or associated responses from the two instruments. No coincident gamma-ray burst events were detected. The resulting integral size spectrum of small bursts, from this and from all other searches, remains a spectrum of upper limits, consistent with an extrapolation of the size spectrum of the largest known bursts, fitting a power low of index -1.5.

Cline, T. L.↗

A balloon-borne 1 meter telescope for far-infrared astronomy

The flight of a balloon-borne one-meter telescope for infrared astronomy in the wavelength interval of 40 to 240 microns is discussed. The gyro-stabilized telescope mapped the intensity of the far infrared radiation from NGC 7538, Mars, the Orion Nebula, and W3 with a resolution of one minute and from selected regions of these sources with a resolution of 30 seconds. The infrared detection is described and its capabilities are analyzed. The instrumentation, orientation system, and modes of observation of the telescope are defined.

Fazio, G. G.↗

Guiding of a balloon-borne coronagraph

Discussion of the guidance system of a balloon-borne coronagraph designed for IR solar corona observations at an altitude of 36 km. The coronagraph has two telescopes, measures 6 m in length, weighs 73 kg, is stabilized by a three-axis system, and has a pointing precision of plus or minus 10 sec of arc. Three torque motors are used to activate the tracking servo system of the coronagraph. An integral control system is used to prevent a permanent instrumental error. The coronagraph has been tested in two balloon missions.

Li, T.-C.↗

The Use of Large Lithium-Drifted, Germanium Diodes for Gamma-Ray Spectral Measurements at Balloon Altitudes

A series of balloon-borne experiments has been initiated at the Oak Ridge National Laboratory (ORNL) in cooperation with the Space Sciences Laboratory of the NASA G. C. Marshall Space Flight Center to determine the feasibility of using large (greater than 20 cc) lithium-drifted, germanium diodes to investigate the spectrum of atmospheric gamma rays (60 keV < E < 1.5 MeV) at altitudes corresponding to a few grams per cm (sup 2) residual atmosphere. The results of these measurements will also provide a basis for designing an appropriate shield for a multi-diode, highly directional gamma-ray spectrometer for use in astrophysical measurements. Two flights were accomplished during 1967 using the same two diodes and basic instrument package. Both flights were launched at the NCAR Scientific Balloon Flight Base, Palestine, Texas, and attained a float altitude of 117, 000 ft. The measured atmospheric gamma-ray spectrum shows at least one distinct line at 511 keV (annihilation radiation) superimposed on a continuous distribution of gamma rays attributable to both energy-degraded gamma rays and brems-strahlung photons. A second diode, encased in a passive shield of plastic and lead, shows the expected lines resulting from both neutron inelastic scattering and capture in the germanium. Data acquisition was accomplished on an event-by-event basis through the use of 512-channel, on-board ADC and word-generator circuits and a ground-based, on-line telemetry decoder. The decoder makes it possible to store the data in the memory of a modified pulse-height analyzer simultaneously with storage on magnetic tape. This provides a real-time visual observation of the data as it is accumulated and greatly facilitates preflight calibrations.

Chapman, G. T.↗

Instrumentation for balloon and rocket experiments.

Description of a number of plasma, particle, and field detectors used on rocket investigations in and above the earth's atmosphere. Emphasis is on magnetospheric and solar-interplanetary studies. A balloon-borne X-ray telescope system with 20-min pointing accuracy is discussed. A PCM telemetry system used on both balloons and rockets to handle scientific data is described which includes a simple Doppler ranging system that gives location to 1.5 km. A system to reduce and analyze PCM data on the ground is discussed.

Anderson, K. A.↗

A quantitative investigation of the solar modulation of cosmic-ray protons and helium nuclei

The differential energy spectra of cosmic ray protons and He nuclei were measured at energies up to 315 MeV/nucleon using balloon-borne and satellite-borne instruments. These spectra are presented for solar quiet times for the years 1966 through 1970. The data analysis is verified by extensive accelerator calibrations of the detector systems and by calculations and measurements of the production of secondary protons in the atmosphere. The spectra of protons and He nuclei in this energy range are dominated by the solar modulation of the local interstellar spectra. Numerical solutions to the transport equation are presented for a wide range of parameters.

Garrard, T. L.↗

Apparatus for controlling the temperature of balloon-borne equipment

A novel apparatus for controlling the temperature of balloon-borne equipment is disclosed, the apparatus serving to utilize the radiant energy emitted by the earth and its atmosphere so as to control the temperature of equipment. The apparatus comprises a housing to be carried aloft by a balloon and defining an enclosure for an instrumentation package. The enclosure includes an upper shield portion as well as a bottom window portion at the base, the bottom window facing the earth below during flight. The upper shield portion is constructed of a material such as aluminized Mylar, which serves to reflect direct sunlight.

Schach, M.↗

The cosmic ray electron spectrum and its modulation from 1968 through 1972

Over the past five years we have measured the energy spectrum of primary cosmic ray electrons with both a balloon-borne and a satellite absorption spectrometer. All of the balloon flights used identical equipment that was launched each summer from Fort Churchill, Manitoba, Canada. The satellite, OGO-5, has been in an eccentric orbit since March 1968. Together these instruments provide the electron spectrum over a range of energy from 20 MeV to 20 GeV. This wide range and the substantial span of time covered by the measurements permit a detailed study of the solar modulation of electrons. These results are compared with the modulation of the nuclear components as observed by a neutron monitor and interpreted using the cosmic ray transport equation.

Fulks, G.↗

Balloon-borne infrared coronagraph

The use of balloon vehicles to observe the solar corona with an infrared coronagraph is reviewed. The scientific results and the instruments employed are discussed. A parallel is drawn between the required functions of a coronagraph and of a far-infrared cold telescope.

Strong, J.↗