Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Diagnostics, Prognostics, and Optimization for Lithium-Ion Battery Systems

Health management of lithium-ion battery systems presents a host of challenges due to their complex physics, large numbers of components, and a wide variety of degradation behaviors across different battery types. Dr. Paul Gasper will present on research from the Electrochemical Energy Storage Group on Lithium-ion battery diagnostics, prognostics, and optimization. Diagnostics research, including state-estimation via machine-learning from electrochemical impedance spectroscopy and DC pulses as well as continuous state-estimation via Kalman filters, will highlight the ongoing challenges for accurately measuring the state of batteries without performing time-consuming characterization tests. NLR's industry-recognized battery prognostics work, which predicts real-world battery degradation by identifying degradation rate models from accelerated aging data using statistical modeling and machine-learning, will be used to demonstrate the critical impact of battery controls, thermal management, and operating strategy on durability and lifetime. Finally, the use of prognostic models for financial or lifetime optimization will be discussed.

25 ENERGY STORAGE↗

All-vanadium sulfate acid redox flow battery system

All-vanadium sulfate redox flow battery systems have a catholyte and an anolyte comprising an aqueous supporting solution including chloride ions and phosphate ions. The aqueous supporting solution stabilizes and increases the solubility of vanadium species in the electrolyte, allowing an increased vanadium concentration over a desired operating temperature range. According to one example, the chloride ions are provided by MgCl2, and the phosphate ions are provided by (NH4)2HPO4.

25 ENERGY STORAGE↗

All-vanadium sulfate acid redox flow battery system

All-vanadium sulfate redox flow battery systems have a catholyte and an anolyte comprising an aqueous supporting solution including chloride ions and phosphate ions. The aqueous supporting solution stabilizes and increases the solubility of vanadium species in the electrolyte, allowing an increased vanadium concentration over a desired operating temperature range. According to one example, the chloride ions are provided by MgCl 2 , and the phosphate ions are provided by (NH 4 ) 2 HPO 4 .

Nie, Zimin↗

Impact resistant battery enclosure systems

Battery enclosure arrangements for a vehicular battery system. The arrangements, capable of impact resistance include plurality of battery cells and a plurality of kinetic energy absorbing elements. The arrangements further include a frame configured to encase the plurality of the kinetic energy absorbing elements and the battery cells. In some arrangements the frame and/or the kinetic energy absorbing elements can be made of topologically interlocked materials.

Tsutsui, Waterloo↗

Optimum Operation of Microgrid Systems that Employ PV Solar and Battery Systems

On a global scale, over 1.3 billion lack access to electricity (85% in rural areas), and approximately 2.8 billion people rely on traditional biomass for cooking. The World Health Organization estimates that household air pollution from inefficient stoves causes more premature deaths than malaria, tuberculosis, and HIV/AIDS. Increasing demand for energy has led to dramatic increases in emissions. The need for reliable electricity and limiting emissions drives research on Resilient Hybrid Energy Systems (RHESs), which provide cleaner energy by combining wind, solar, and biomass energy with traditional fossil energy, increasing production efficiency and reliability and reducing generating costs and emissions. Microgrids have been shown as an efficient means of implementing RHESs, with some focused mainly on reducing the environmental impact of electric power generation. The technical challenges of designing, implementing, and applying microgrids involve conducting a cradle-to-grave Life Cycle Analysis (LCA) to evaluate these systems’ environmental and economic performance under diverse operating conditions to evaluate resiliency. A sample RHES was developed and used to demonstrate the implementation in rural applications, where the system can provide reliable electricity for heating, cooling, lighting, and pumping clean water. The model and findings can be utilized by other regions around the globe facing similar challenges.

Nagapurkar, Prashant↗

Multiscale model predictive control of battery systems for frequency regulation markets using physics-based models

In this work, we propose a multiscale model predictive control (MPC) framework for stationary battery systems that exploits high-fidelity models to trade-off short-term economic incentives provided by energy and frequency regulation (FR) markets and long-term degradation effects. We find that the MPC framework can drastically reduce long-term degradation while properly responding to FR and energy market signals (compared to MPC formulations that use low-fidelity models). Our results also provide evidence that sophisticated battery models can be embedded within closed-loop MPC simulations by using modern nonlinear programming solvers (we provide an efficient and easy-to-use implementation in Julia). We use insights obtained with our simulations to design a low-complexity MPC formulation that matches the behavior obtained with high-fidelity models. This is done by designing a suitable terminal penalty term that implicitly captures long-term degradation. The results suggest that complex degradation behavior can be accounted for in low-complexity MPC formulations by properly designing the cost function. We believe that our proof-of-concept results can be of industrial relevance, as battery vendors are seeking to participate in fast-changing electricity markets while maintaining asset integrity.

42 ENGINEERING↗

Dispersion of stored energy within a battery system at risk of failure

A method and system for dispersing stored energy in an energy storage system to delay or arrest propagation of thermal runaway and thermally-induced cascading failures. The system includes a plurality of battery sub-assemblies and DC-DC converters connected to a shared DC bus through which energy may be exchanged. The system may be interfaced to an AC power grid or DC power system through an additional power converter. The method of dispersing stored energy uses this system to charge and discharge sub-assemblies such that the system is less susceptible to propagation of thermal runaway. The method determines, based on awareness of current system state, battery types, and electrical and thermal structure, the sequence of charging and discharging actions to best inhibit thermal runaway while preserving the system's ability to perform subsequent energy redistribution.

Mueller, Jacob↗

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

SENA Hydro Battery Systems Catalog Development

The Hydro Battery catalog development project started in 2017 with the objective of developing a collection of modular engineering design elements, repurposing oil & gas industry techniques and materials, that can be replicated for smaller, lower cost, and faster deploying pumped storage projects in the United States. One notable design element of the catalog involved a floating membrane containment system to achieve closed loop configurations in naturally open body environments. The intent of this particular system is to provide an option to mitigate environmental impacts at sites with technoeconomic merits but aquatics and water quality sensitivities to an alternative open-loop design.

13 HYDRO ENERGY↗

Building-to-Grid Modeling Framework with a Case Study of Battery Systems

Coordinating electricity load shifting operations of multiple buildings has the potential to achieve significant benefits for both building owners and grid operation. In support of this research, this paper develops a novel building-to-grid modeling framework, which uses EnergyPlus to develop physics-based building energy models and GridLAB-D to develop distribution-level grid models. The data exchanges between buildings and distribution-level grid are conducted using Python script and HELICS co-simulation platform. Then, by using this modeling framework, this paper conducts a case study of battery systems in a connected community, which consists of 10 multi-family buildings with appropriately sized batteries. The three scenarios, baseline operation, tolerant to price fluctuations, and opportune usage, are studied. The result displays that, by adopting onsite batteries, both electricity costs for building owners and aggregated peak power demands are reduced.

Building-to-grid, connected community, co-simulati↗

Methods and system for a battery

Systems and methods for operating a redox flow battery system may include switching the redox flow battery system to an idle mode, wherein the idle mode includes operation of the redox flow battery system outside of a charging mode and outside of a discharge mode; in response to switching to the idle mode, repeatedly cycling operation of an electrolyte pump between an idling threshold flow rate less than a charging threshold flow rate and a deactivation threshold flow rate; and in response to switching to the charging mode, maintaining operation of the electrolyte pump at the charging threshold flow rate greater than the idling threshold flow rate. In this way, a responsiveness of the redox flow battery system to charging and discharging commands can be maintained while in idle, while reducing parasitic pumping losses due to pumping and heating, and reducing shunt current losses.

Song, Yang↗

High efficiency electrolytes for high voltage battery systems

Disclosed herein are embodiments of an electrolyte that is stable and efficient at high voltages. The electrolyte can be used in combination with certain cathodes that exhibit poor activity at such high voltages with other types of electrolytes and can further be used in combination with a variety of anodes. In some embodiments, the electrolyte can be used in battery systems comprising a lithium cobalt oxide cathode and lithium metal anodes, silicon anodes, silicon/graphite composite anodes, graphite anodes, and the like.

Ren, Xiaodi↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simultaneous Heat and Electricity Storage in a Flow Battery System

This study investigates the dual-storage capability of a redox flow battery (RFB) system, enabling simultaneous storage of heat and electricity within a single platform. Through electrochemical and thermal experiments, we evaluated how heat storage affects battery performance and vice versa using a counterflow heat exchanger integrated in a conventional RFB configuration. The results show that incorporating heat storage had a minimal impact on the electrochemical charging and discharging processes. Further, the heat discharge operated independently of electrochemical storage, confirming that both functions can coexist without interference. The combined system also enhanced overall energy conversion efficiency, demonstrating its potential as an efficient solution for supplying both thermal and electrical energythe two most widely used energy forms.

Electrical energy↗

Microreactor-liquid metal battery system in energy markets: An evaluation of potential costs, technology, and policy impacts

Microreactors represent an emerging innovation in the nuclear industry; yet have been overshadowed by their high capital costs. With the Inflation Reduction Act of 2022 (IRA), new opportunities have emerged to improve the economics of microreactor systems. This work examines liquid metal batteries (LMB) as a value-adding technology as part of microreactor-LMB systems within three U.S. electricity markets: ERCOT, PJM, and MISO. Our investigation considers key uncertainties: the cost of microreactors, the performance of LMBs, and the eligible tax credit levels. To this end, we use a dispatch optimization to trace not only the changes in system economics but also to provide a granular picture of energy delivery within the systems. We find that even with favorable costs for microreactors, significant regional variations in the project sizing and returns exist across the markets. Our heuristic method identifies their non-electric application potentials beyond electricity and technical requirements to maximize returns. The results suggest that 12–39 % of reactor heat could be cost-effectively diverted to produce more valuable by-products in U.S. markets. Including the impacts of tax credits, we establish the outcomes of each provision with varying rates. Coupling an LMB to a microreactor consistently improves the net present value of a microreactor compared to its standalone operation. In conclusion, for reasonable assumed conditions, we quantify a heterogeneous impact of round-trip efficiency (RTE) and extended LMB service life across the three markets—a one-year extension in LMB service life is roughly equivalent to a 2.11 % improvement in RTE for ERCOT, 1.16 % for PJM, and 1.04 % for MISO.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗