Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

Machine protection system for coherent electron cooling experiment

The coherent electron cooling (CeC) experiment employs a 15 MeV electron beam with up to a few milliamperes current which is capable of destroying the vacuum equipment or intercepting beam diagnostics. The high-current beam can be delivered to two different dumps. RF systems include normal conducting and superconducting cavities which also require protection from abnormal conditions. In this paper, we describe in detail the design and operation of the machine protection system for the CeC accelerator.

43 PARTICLE ACCELERATORS↗

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap↗

The effect of filament peaking on electron beam weld quality

Electron beam welding uses high intensity beams that are generated by an electron emitting cathode under high vacuum conditions. The cathode, typically a ribbon or wire filament of refractory metal, must be heated to sufficiently high temperatures for electron emission to occur and must be carefully controlled to produce the desired beam current while at the same time optimizing filament lifetime. Traditional methods for doing this in commonly used triode gun assemblies consist of first finding the filament knee point in the filament current versus beam current relationship that produces the desired beam current for a given beam voltage. The filament current is then increased by some amount, typically 5–10%, per conventional wisdom to produce a peaked beam. This investigation studies and quantifies the beam and weld quality produced by underkneed and overpeaked filaments using electron beam diagnostics to measure the power density distribution of these beams. Underkneed filaments are shown to have power densities that drop off very quickly below the traditional knee, resulting in poor weld penetration. Kneed filaments do not reach the full beam intensity and also produce shallow welds. Increasing the filament current 10% above the traditional knee was shown to produce a circular Gaussian-like beam with peaked intensity optimized for welding and for filament lifetime. Further increases in the filament current that produce overpeaked beams do not significantly change the beam or weld quality and would only contribute to a reduced filament lifetime.

Electron Beam Welding↗

Solenoidal Fields from Permanent Magnets for a Polarized Electron Preinjector

This technical note describes the design of a compact focusing solenoid constructed from permanent bar magnets, intended for the low-energy section of a spin-polarized electron injector. Typically, quadrupole triplets provide appropriate focusing for the low-energy spin rotator section; however, their large footprint precludes the insertion of sufficient beam diagnostics. The primary motivation of this study is to provide beam focusing while preserving the vertical spin orientation of the electron beam. We propose a solenoidal field composed of multiple permanent magnets arranged to naturally yield a zero longitudinal magnetic field integral ($\int B_zdz = 0$). This design serves as a compact, passive, and non-coupling alternative to traditional quadrupole triplets. We present the magnet arrangement, field calculation methodology, spin tracking simulations using space charge codes, and calculations demonstrating that the required field strength is achievable.

43 PARTICLE ACCELERATORS↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

ORBIT CORRECTION STUDIES ON THE ELECTRON TRANSPORT LINE FROM RCS TO ESR

A dedicated electron transfer line from Rapid Cycling Synchrotron (RCS) to Electron Storage Ring (ESR), referred to as the RTE line has been designed for the Electron-Ion Collider (EIC). The beamline follows a straight-line geometry, with a length of 133 m, and is consists with two matching sections and a FODO section for beam diagnostics. Imperfections with magnet alignments introduce orbit distortions, making orbit correction scheme a critical component in the design. To facilitate orbit correction, each quadrupole magnet is equipped with a pair of beam position monitors (BPMs) and kickers. The Singular Value Decomposition (SVD) algorithm is used for orbit correction and tolerance studies. This paper presents the ongoing progress in the optics design and error correction scheme of the RTE line.

Neththikumara, I. [Thomas Jefferson National Accel↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.

43 PARTICLE ACCELERATORS↗

Toroid Signal Processing Container with Redis Integration

This report presents the research, design, and implementation of a Toroid Signal Processing Container with Redis Integration, conducted during my internship assignment. The project focused on developing a modular signal processing sys- tem capable of performing baseline correction, droop compensation, and real- time data communication for beam diagnostic signals. Using Redis as a message broker and configuration manager, the system ensures modularity, scalability, and efficient inter-process communication. Signal correction algorithms, such as Asymmetric Least Squares (ALS) baseline smoothing and a numerical droop correction approach, were implemented and tested using Linac beam data. The results confirm that this system improves signal fidelity and supports real-time analysis requirements, offering valuable contributions to the field of beam instrumentation and data acquisition systems.

Bowers, Elliot [Cabrillo Coll.]↗

Toroid Signal Processing Container with Redis Integration

This report presents the research, design, and implementation of a Toroid Signal Processing Container with Redis Integration, conducted during my internship assignment. The project focused on developing a modular signal processing sys- tem capable of performing baseline correction, droop compensation, and real- time data communication for beam diagnostic signals. Using Redis as a message broker and configuration manager, the system ensures modularity, scalability, and efficient inter-process communication. Signal correction algorithms, such as Asymmetric Least Squares (ALS) baseline smoothing and a numerical droop correction approach, were implemented and tested using Linac beam data. The results confirm that this system improves signal fidelity and supports real-time analysis requirements, offering valuable contributions to the field of beam in- strumentation and data acquisition systems.

Bowers, Elliot [Cabrillo Coll.; Fermilab]↗

Detectors and beam monitors based on wide bandgap semiconductors at cryogenic temperatures

Wide-bandgap semiconductors, such as single-crystal diamond and sapphire, can be used to measure the flux of passing particles through a particle-induced conductivity effect. We recently demonstrated a diamond-based, electrodeless electron beam halo monitor. This monitor utilized a thin diamond blade placed within an open, high-quality microwave resonator. The blade partially intercepted the beam and changes in the RF properties of the resonator were used to infer beam parameters. To enhance the sensitivity of our semiconductor sensors, we propose two new techniques: (1) biasing the semiconductor sensor to support avalanche multiplication of free carriers, and (2) operating at cryogenic temperatures to reduce intrinsic semiconductor losses and increase the mobility of induced carriers. These techniques are applicable not only to particle beam diagnostics but also to the detection of various types of ionizing radiation.

Accelerator Physics↗

Realizing the scientific program with polarized ion beams at the future BNL Electron Ion Collider

Polarized ion beams at the Electron Ion Collider (EIC) are essential to address some of the most important open questions at the twenty-first century frontiers of understanding of the fundamental structure of matter. Here, in this work, we summarize the science case and identify polarized 2 H, 3 He, 6 Li, and 7 Li ion beams as critical technology that will enable experiments which address the most important science. Furthermore, we discuss the required ion polarimetry and spin manipulation at the EIC. The current EIC accelerator design is presented. We identify a significant research and development effort across national and international laboratories and universities that is required over about a decade to realize the polarized ion beams and estimate (based on previous experience) that it will require about 20 full-time equivalent (FTE) over 10 years (or a total of about 200 FTE-years) of personnel, including graduate students, postdoctoral researchers, technicians, and engineers. Attracting, educating, and training a new generation of physicists in experimental spin techniques will be essential for the successful realization. Artificial intelligence and machine learning are seen as having significant potential for both acceleration of research and development and amplification of discovery in the optimal realization of this unique quantum technology on a cutting-edge collider. The research and development effort is synergistic with research in atomic physics and fusion energy science.

43 PARTICLE ACCELERATORS↗

Acceleration of uranium beam to record power of 10.4 kW and observation of new isotopes at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗