Search NASASearch

SEARCH · Search NASA

Results for “Beam dump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

96 records · Page 2

Investigating Laser Beam Welding as an In-Space Joining Technique via Thermal Vacuum and Microgravity and Vacuum Experiments

In-space joining technologies are crucial for stimulating an in-space economy and for enabling sustained space exploration by in-space manufacturing and repair of metallic structures. Compared to brazing or soldering, in-space welding (ISW) can provide highly hermetic, strong, and complex joints, potentially without introducing additional material. However, the influence of extreme temperatures, reduced pressure, and reduced gravity on ISW is not yet fully elucidated. Several efforts at NASA are investigating laser beam welding (LBW) as a joining and repair method in both thermal vacuum (TVAC) and combined vacuum & reduced gravity environments. NASA Marshall Space Flight Center (MSFC) shepherded several ISW projects in its past, including the 1973 electron beam welding on Skylab, the 1989 low-power LBW on parabolic flights, and the unflown 1990s-era In-Space Welding Experiment. Recent parabolic flights and 3 degree-of-freedom ground testing build upon this heritage. A collaboration with the Ohio State University using NASA Langley Research Center (LaRC) hardware retrofitted for LBW achieved the first high-powered laser welds under vacuum and low gravity and developed a workforce capable developing such experimental hardware. A ground testing campaign at the MSFC Flat Floor simulated fit-up and welding representative of ISW in 3 degrees of freedom to emulate microgravity effects on inertial systems. One ongoing effort is a NASA Early Career Initiative project – Lunar Assembly and Servicing by Autonomous Robotics (LASAR). Ruggedized LBW components were developed by an external partner for use in TVAC. A TVAC-rated robotic arm was procured by MSFC and used in the first known robotic laser weld where all components save the laser generator were under vacuum. NASA Johnson Space Center (JSC) is advancing supervised autonomy of ISW. NASA LaRC continues to adapt their unique snowflake joint geometry, suitable for connecting segments in trusses and other structures, to LBW. Upcoming TVAC campaigns will focus on testing extreme temperatures, proving out autonomous operations, and demonstrating weld repair. Weld inspection will occur via a non-contact nondestructive evaluation (NDE) technique – electromagnetic acoustic transduction (EMAT). Another ongoing effort based at MSFC is the DISCMAN -- DIsk-Shaped Configurable and Modular vAcuum uNit – which seeks to development a compact, modular payload that can provide a vacuum environment while in a reduced gravity condition. This payload could support multiple in-space manufacturing developmental efforts, with the first demonstration technology being LBW. Currently, the design is targeting operations in the pressurized volume of a space station, but the payload could readily be adapted to other flight platforms such as parabolic or even suborbital vehicles. LASAR elucidates the effects of temperature and vacuum on LBW while DISCMAN probes those of vacuum and gravity. Through these complementary efforts, NASA is addressing the primary challenges of ISW across the space environment while simultaneously developing and maturing technologies including robotic systems and inspection methodologies for future practical implementation on the Moon and beyond. This approach is timely, as upcoming missions requiring sustained human presence in space will depend on reliable ISW capabilities to create robust metallic joints currently unproven in the space environment and to perform repairs in situ .

hypogravity

Toward the Limits of Nuclear Existence: First Science with FRIB

The opportunity to explore the properties of short-lived atomic nuclei—or rare isotopes—in laboratories has enabled discoveries across the sciences related to the nature of the nuclear force and the limits of nuclear existence, the origin of the elements in the Universe, the cosmic matter–antimatter asymmetry, and the application of rare isotopes for society and the nation. The newest-generation Facility for Rare Isotope Beams (FRIB) on the campus of Michigan State University commenced operations in May 2022 as a user facility for the US Department of Energy, Office of Science, Office of Nuclear Physics. FRIB provides fast, stopped, and reaccelerated beams of rare isotopes for measurements, serving a 1,800-member-strong community of scientists from around the world. Here, this article reviews some of the first results from FRIB, showcasing the breadth of the science discoveries that have already occurred while the facility is ramping up to full capability.

FRIB

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]

An Initial Study of Using the 34-M Antenna for Lunar Mission Support

As a part of the long-range planning of future Mars and lunar missions, a feasibility study was made of a 34-m antenna system with differentially pointed multiple beams. The performance loss mechanisms of the differentially pointed multiple-beam systems were identified and quantified. Techniques that can significantly improve the multiple-beam system performance are identified. The goal is to determine the feasibility of using the 34-m antenna to support widely separated elements associated with lunar missions.

A Cha

The Canadian Galactic Emission Mapper: A New 8-10 GHz Telescope To Map the Polarization of the Northern Sky

The Canadian Galactic Emission Mapper (CGEM) radio telescope is mapping polarized Galactic foregrounds from 8-10 GHz to aid in the search for B-modes in the Cosmic Microwave Background (CMB). Here we describe the design and early on-sky characterization of the CGEM optics. CGEM employs an on-axis, hat feed optical design that is a body of revolution (BOR) and exhibits excellent intrinsic polarization purity. We describe how we have optimized the optics with a novel framework that can directly minimize simulated intensity to polarized intensity (T → P) leakage in angular power spectrum space. The optimized optics exhibit simulated T → P leakage that is orders of magnitude below anticipated CℓBB for r = 10 −3 when scaled from 8-10 GHz to the CMB observing window near 95 GHz. We go on to describe the mechanical design of the optics, including a novel secondary mirror support made from Astroquartz composite that has low loss, low dielectric constant, and preserves the BOR symmetry of the optics. We then showcase the early on-sky performance of the optics with observations of the Sun and satellites, which probe the beam to 40dB down from the peak. A beam model for the deployed CGEM optics based on electromagnetic simulations is in excellent agreement with the on-sky data.

cosmic microwave background

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Fingerprinting Uranium Oxides with Electron Energy Loss Spectroscopy Supported by Theoretical Computations

Uranium oxides occur in a variety of phases that differ in crystal structure and uranium oxidation states. Electron energy loss spectroscopy (EELS) is one of the few techniques that has sufficient spatial resolution and sensitivity to electronic structure to distinguish amongst phases at the nanoscale. However, beam-sensitive materials such as uranium oxides are subject to spectral modification due to interactions with the electron beam. Therefore, theory support is essential to reliably exclude the impact of beam damage and generate true reference datasets. Here we use a comparison of theoretical and experimental spectra to probe the impact of beam damage on O K-edge and U N-edge (N6,7 and N4,5) EELS spectra of various single-valent and mixed-valence uranium oxide bulk phases. Using a low-dose experimental set-up, we show that the O K-edge theoretical spectra are in excellent agreement with experiment for both peak positions and relative intensities of respective peaks. In contrast, U N-edge features are less distinguishing due to the partially localized nature of the U 5f orbitals and overlapping multiplet and spin–orbit coupling effects. This work demonstrates that O K-edge EELS is sufficiently diagnostic to distinguish a wide range of uranium oxides and that the experimental approach used here minimizes beam damage and allows valence state discrimination across the U(IV), U(V) and U(VI) series. When combined with imaging modes available in electron mi-croscopy, the work enables detailed investigation and characterization of uranium redox transformations at the nanoscale.

Carbone, Jacopo

Passive continuous variable quantum key distribution scheme using a thermal source

A passive continuous variable quantum key distribution scheme, where Alice splits the output of a thermal source into two beams, measures one locally and transmits the other mode to Bob after applying attenuation. A secure key can be established based on measurements of the two beams without the use of a random number generator or an optical modulator.

Qi, Bing

A simplified di-homodyne transient grating spectroscopy system utilizing polarization

Here, a modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.

Simmonds, M. J. [Univ. of California, San Diego, C

Spin-strain interactions under hydrostatic pressure in α-RuCl 3

We investigate the effects of hydrostatic pressure on 𝛼−RuCl 3 , a prototypical material for the Kitaev spin model on a honeycomb lattice with a possible spin-liquid ground state. Using ultrasound measurements at pressures up to 1.16 GPa, we reveal significant modifications of the acoustic properties and the 𝐻−𝑇 phase diagram of this material. Hydrostatic pressure suppresses the three-dimensional magnetic order and induces a dimerization transition at higher pressures. At low pressures, the sound attenuation exhibits a linear temperature dependence, while above 0.28 GPa, it becomes nearly temperature independent, suggesting a shift in the phonon scattering regime dominated by Majorana fermions. These findings provide new insights into spin-strain interactions in Kitaev magnets and deliver a detailed characterization of the 𝐻−𝑇 phase diagram of 𝛼−RuCl 3 under hydrostatic pressure.

Focused ion beam

Additively manufactured refractory high-entropy alloys with superior radiation resistance

Refractory high-entropy alloys (RHEAs) are promising candidates for next-generation nuclear and high-temperature applications. Among many approaches to manufacture RHEAs, additive manufacturing (AM) represents the most recent and advanced metal manufacturing method which allows near-net-shape manufacturing to reduce material waste and post-processing time. However, performance of AM RHEAs under complex irradiation conditions remains largely unexplored. Here, in this study, we demonstrate for the first time the response of directed energy deposition (DED) AM quaternary RHEAs (HfTaVW, CrTaVW) subjected to sequential dual-beam ion irradiation, consisting of helium pre-implantation followed by high-dose heavy ion bombardment. Compositions of DED AM RHEAs were selected using Monte Carlo (MC) simulations based on a cluster expansion (CE) Hamiltonian parameterized by density functional theory (DFT). Post-irradiation microstructural characterization revealed that the AM RHEA maintained remarkable stability, with suppressed helium bubble growth and reduced defect accumulation compared to conventional alloys. Even at high doses (∼100 dpa), the alloy exhibited no void swelling, a low density of dislocation loops, and no evidence of severe degradation. These results highlight the intrinsic ability of AM-derived microstructures and multicomponent chemistry to synergistically mitigate irradiation effects. Our findings establish AM RHEAs as a class of materials with superior resistance to radiation damage under conditions relevant to advanced fusion and fission environments and demonstrate the importance of sequential ion beam studies in evaluating their long-term performance.

36 MATERIALS SCIENCE

An Overview of the Galileo Optical Experiment (GOPEX)

Uplink optical communication to a deep-space vehicle was demonstrated. In the Galileo Optical Experiment (GOPEX), optical transmissions were beamed to the Galileo spacecraft by Earth-based transmitters at the Table Mountain Facility (TMF), California, and Starfire Optical Range (SOR), New Mexico. The demonstration took place over an eight-day period (9 Dec. through 16 Dec. 1992) as Galileo receded from Earth on its way to Jupiter, and covered ranges from 1-6 million km. At 6 million km (15 times the Earth-Moon distance), the laser beam transmitted from TMF eight days after Earth flyby covered the longest known range for transmission and detection.

K E Wilson

Galileo Optical Experiment (GOPEX) Optical Train: Design and Validation at the Table Mountain Facility

The Galileo Optical Experiment (GOPEX) has demonstrated the first laser communications uplink to a deep space vehicle. This article describes the optical design and validation tests performed at the Table Mountain Facility (TMF) transmitter site. The system used a 0.6-m telescope and an optical system at coude focus to produce the uplink beam. The optical system used a pulsed neodymium:yttrium-aluminum-garnet (Nd:Yag) laser and beam diverger optics to produce the required optical output. In order to validate the optical design, a number of uplinks were performed on Earth-orbiting satellites (e.g., Lageos 1 and 2).

J Yu

Evaluation of Various Methods for Determining Bulk Compositions of Chondrules and Other Objects in Petrographic Thin Sections

Studies of many objects in petrographic thin section, such as melt inclusions in igneous rocks, chondrules and Ca-Al rich inclusions in chondritic meteorites, or clasts in lunar and other breccias, require or can benefit from knowledge of their bulk compositions. Given the scarcity of these materials, the reluctance of curators to provide more abundant material, and the extreme difficulty of cleanly separating such objects from their rock matrices, geochemical and cosmochemical studies need the ability to determine their bulk compositions from in situ methods, such as defocused beam analysis, or quantitative chemical mapping by electron beam methods.

Daniel Kent Ross

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Surface Tension Driven Convection Experiment (STDCE)

Results are reported of the Surface Tension Driven Convection Experiment (STDCE) aboard the USML-1 (first United States Microgravity Laboratory) Spacelab which was launched on June 25, 1992. In the experiment 10 cSt silicone oil was placed in an open circular container which was 10 cm wide by 5 cm deep. The fluid was heated either by a cylindrical heater (1.11 cm dia.) located along the container centerline or by a CO 2 laser beam to induce thermocapillary flow. The flow field was studied by flow visualization. Several thermistor probes were placed in the fluid to measure the temperature distribution. The temperature distribution along the liquid free surface was measured by an infrared imager. Tests were conducted over a range of heating powers, laser beam diameters, and free surface shapes. In conjunction with the experiments an extensive numerical modeling of the flow was conducted. In this paper some results of the velocity and temperature measurements with flat and curved free surfaces are presented and they are shown to agree well with the numerical predictions.

S Ostrach

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens