24 records · Page 2

Enabling dynamic 3D coherent diffraction imaging via adaptive latent space tuning of generative autoencoders

Abstract Coherent diffraction imaging (CDI) is an advanced non-destructive 3D X-ray imaging technique for measuring a sample’s electron density. The main challenge of CDI is loss of phase information in diffraction intensity measurements, resulting in lengthy iterative reconstruction processes that can return non-unique solutions, which pose challenges for experiments attempting to track dynamic sample evolution through multiple states. As the increased brightness of fourth-generation light sources enables faster sample measurements and drives operando experiments with Bragg CDI, there is a growing need for faster reconstruction techniques that can keep pace. We have developed an adaptive generative autoencoder approach for uniquely tracking a sample’s electron density as it dynamically evolves. Our approach adaptively tunes the low-dimensional latent embedding of a generative autoencoder, enabling a computationally efficient manner to account for time-varying shifting distributions in real-time. Analytic proof of convergence is provided as well as numerical demonstration of sample tracking with noisy measurements.

97 MATHEMATICS AND COMPUTING

X‑ray Coherent Diffractive Imaging of Large Helium Nanodroplets Doped with Small Molecules

We report the first X-ray coherent diffractive imaging experiment on molecule-doped helium nanodroplets. It complements previous work, where we reported single-shot X-ray coherent diffractive imaging studies of Xe dopant clusters formed in 4He and 3He droplets. These noble gas clusters were used to visualize the impact of rotational excitation of the droplets on the spatial distribution of atomic dopants within the droplets, and to study the differences and connections between quantum and classical droplet rotational motion. Here, we expand our studies to the molecular dopants CF4, CHF3, CH3CN, and SF6, imaged with 1.5 keV photons. We find multiple Bragg spots in the diffraction patterns of molecule-doped droplets with radii of approximately 600 nm, which provide evidence that molecules form elongated clusters with preferential alignment along the angular momentum axis of the 4He droplets, in agreement with our previous results on the aggregation of Xe clusters on quantum vortices. Real-space reconstructions of molecular dopant cluster density profiles are obtained for droplets with smaller radii of approximately 300 nm. The diffuse images suggest the formation of low-density, potentially porous, molecular clusters upon aggregation at T = 0.4 K in 4He droplets. In the normal fluid 3He droplets, molecules aggregate into loose clusters on the droplets' equator, similar to previous observations for Xe atoms. Time-of-flight mass spectra reveal that the doped helium nanodroplet moieties fragment extensively into constituent atomic ions, producing only a small fraction of molecular fragment ions. The findings are discussed in the context of previously proposed schemes to use He droplets as potential tamper materials for ultrafast X-ray imaging experiments.

Feinberg, AlexandraJ

Imaging the Progression of Radiolytic Damage in Molecular Crystals with Scanning Nanobeam Electron Diffraction

Almost every electron microscopy experiment is fundamentally limited by radiation damage. Nevertheless, little is known about the onset and progression of radiolysis in beam-sensitive materials. Here we apply ambient-temperature scanning nanobeam electron diffraction to record simultaneous dual-space movies of organic and organometallic nanocrystals at sequential stages of beam-induced radiolytic decay. We show that the underlying mosaic of coherently diffracting domains undergoes internal rearrangement as a function of accumulating electron fluence, causing the intensities of some associated Bragg reflections to fade nonmonotonically. Furthermore, we demonstrate that repeated irradiation at a single probe position leads to the isotropic propagation of delocalized radiolytic damage well beyond the direct footprint of the incident beam. We refer to these expanding tides of amorphization as “impact craters.”

59 BASIC BIOLOGICAL SCIENCES

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.

Extending the Takagi-Taupin equations for x-ray nanobeam Bragg coherent diffraction

We present an approach for simulating x-ray nanobeam Bragg coherent diffraction patterns based on the Takagi-Taupin equations. Compared to conventional methods, the current approach can be universally applied to any weakly strained system including semi-infinite crystals that diffract dynamically. It addresses issues such as the curved wave front and redivergence of the focused incident beam. In conclusion, we show excellent agreement with experimental data for a strained La 0.7 ⁢Sr 0.3⁢ MnO 3 thin film on a SrTiO 3 substrate and a path to extracting physical information using automatic differentiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND