Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Challenges and Practical Solutions for Conducting Structural MARSSIM Surveys in Elevated Radon Environments - 20413

The Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) [1] provides comprehensive guidance for the development and implementation of radiological surveys conducted to demonstrate compliance with a dose- or risk-based cleanup goal during final status survey. The MARSSIM methodology follows an integrated strategy combining direct measurements and sampling to assess uniform residual contamination, and scanning surveys to identify localized areas of elevated activity. Building surveys assessing residual surface contamination present unique challenges from reliance on field measurements that may be subject to less than ideal environmental conditions. Additionally, limited characterization and excessive conservatism incorporated into the conceptual site model may result in derived concentration guideline levels (DCGL) and, as a consequence of relatively inefficient field instrumentation, corresponding attributable count rates generally comparable to background. The presence of elevated ambient radon concentrations and associated progeny deposition both exacerbate these intrinsic survey challenges and introduce a series of technical, logistic, and administrative obstacles that can wreak havoc on the statistical legitimacy of each component of the MARSSIM process. Short-lived radon progeny including polonium-218, lead-214, bismuth-214, and polonium-214 produce excessive alpha and beta radiation that may decrease instrument sensitivity through an increase in background count rates, and, at worst, may result in incorrect survey unit failure through the simulation of residual surface activity. Aside from the obvious solution of exhaustive radon mitigation, the primary objectives are to distinguish between radon progeny deposition and actual surface activity, and collect sufficient defensible data. The following is a technical discussion of the consequences of performing building MARSSIM surveys in the presence of elevated ambient radon atmospheres, conceptual examples, and an overview of practical strategies to minimize the effects of radon interference while collecting sufficient defensible data to complete the survey. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

In 2019, the eROSITA telescope on board the Russian-German satellite Spectrum-Roentgen-Gamma (SRG) began to perform a deep all-sky X-ray survey with the aim of identifying ~100 000 clusters and groups over the course of four years. As part of its performance verification phase, a ~140 deg 2 survey, called eROSITA Final Equatorial-Depth Survey (eFEDS), was performed. With a depth typical of the all-sky survey after four years, it allows tests of tools and methods as well as improved predictions for the all-sky survey. As part of this effort, a catalog of 542 X-ray selected galaxy group and cluster candidates was compiled. Here, in this paper, we present the optical follow-up, with the aim of providing redshifts and cluster confirmation for the full sample. Furthermore, we aim to provide additional information on the dynamical state, richness, and optical center of the clusters. Finally, we aim to evaluate the impact of optical cluster confirmation on the purity and completeness of the X-ray selected sample. We used optical imaging data from the Hyper Suprime-Cam Subaru Strategic Program and from the Legacy Survey to identify optical counterparts to the X-ray detected cluster candidates. We make use of the multi-component matched filter cluster confirmation tool (MCMF), as well as of the optical cluster finder CAMIRA to derive cluster redshifts and richnesses. MCMF provided the probabilities with which an optical structure would be a chance superposition with the X-ray candidate. These probabilities were used to identify the best optical counterpart as well as to confirm an X-ray candidate as a cluster. The impact of this confirmation process on catalog purity and completeness was estimated using optical to X-ray scaling relations as well as simulations. The resulting catalog was furthermore matched with public group and cluster catalogs. Optical estimators of the cluster dynamical state were constructed based on density maps of the red-sequence galaxies at the cluster redshift. By providing redshift estimates for all 542 candidates, we construct an optically confirmed sample of 477 clusters and groups with a residual contamination of 6%. Of these, 470 (98.5%) are confirmed using MCMF, and 7 systems are added through cross-matching with spectroscopic group catalogs. Using observable-to-observable scaling and the applied confirmation threshold, we predict that 8 ± 2 real systems have been excluded with the MCMF cut required to build this low-contamination sample. This number agrees well with the 7 systems found through cross-matching that were not confirmed with MCMF. The predicted redshift and mass distribution of this catalog agree well with simulations. Thus, we expect that these 477 systems include >99% of all true clusters in the candidate list. Using an MCMF-independent method, we confirm that the catalog contamination of the confirmed subsample is 6 ± 3%. Application of the same method to the full candidate list yields 17 ± 3%, consistent with estimates coming from the fraction of confirmed systems of ~17% and with expectations from simulations of ~20%. We also present a sample of merging cluster candidates based on the derived estimators of the cluster dynamical state.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

International Workshop on Security of Radioactive Sources during Extraordinary Events

On May 2, 2019, a subcontractor to Los Alamos National Laboratory (LANL) inadvertently breached a sealed Cs-137 source while attempting to remove the source for disposition as part of a United States (US) government-sponsored program. The source breach resulted in contamination of personnel, the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The QUIC Start Guide (V.6.4.9)

QUIC stands for the Quick Urban & Industrial Complex (QUIC) dispersion modeling system. QUIC is a fast response urban dispersion model that runs on a laptop. QUIC is comprised of a 3D wind field model called QUIC-URB, a transport and dispersion model called QUIC-PLUME, and graphical user interface called QUIC-GUI. QUIC also includes QUIC-PRESSURE to solve for pressure fields in and around buildings, a population exposure assessment tool called QUIC-POP, and an indoor infiltration calculator for computing indoor concentrations. Transport and dispersion for different types of airborne contaminants can be computed on building to neighborhood scales in tens of seconds to tens of minutes. QUIC will never give perfect answers, but it will account for the effects of buildings in an approximate way and provide more realism than non-building aware dispersion models.

97 MATHEMATICS AND COMPUTING↗

Los Alamos National Laboratory Release of Cesium-137 Corrective Action Plan

This Corrective Action Plan (CAP) was developed by a team chartered by John Sarrao, Deputy Director for Science, Technology, and Engineering (DDSTE), to review and respond to the findings of the Joint National Nuclear Security Administration/Triad National Security (NNSA/Triad) Investigation Team (JIT) Joint Investigation Report for the “Sealed Source Recovery at the University of Washington Harborview Training and Research Facility Results in Release of Cesium-137 on May 2, 2019,” dated March 30, 2020. On May 2, 2019, International Isotopes, Inc. (INIS), a subcontractor to Triad National Security, LLC, inadvertently breached a sealed cesium-137 source at the University of Washington (UW), Harborview Medical Center Research and Training (HRT) building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration (NNSA) Off-Site Source Recovery Program (OSRP). The source breach resulted in contamination of personnel and the HRT building, as well as a release of radioactive material to the environment

07 ISOTOPE AND RADIATION SOURCES↗

Wash Penalty Factors: Insight into the Effects of Water Wash Down of Building Materials for Radionuclide/Nuclear (Rn) Decontamination - 20153

The release of radiological material to the urban environment can have a devastating socio-economic impact. In an urban release scenario, areas around the dispersal epicenter and any areas contaminated via atmospheric deposition may require extensive decontamination. Most recently, our group reported the decontamination efficacy of pressurized water washing of common porous building materials, and compared the penetration depth of the contaminations before and after exposure to pressurized tap water. Here, we continue evaluation of the decontamination efficacy of wash solutions based on potassium (K{sup +}) salt for cesium (Cs), strontium (Sr), and europium (Eu) contaminations on common building surfaces. The surfaces included: the cement used in concrete, the aggregate used in concrete, intact concrete, roadway asphalt, asphalt shingles, and latex paint. We deposited solutions of {sup 137}Cs, {sup 85}Sr, and {sup 152}Eu onto numerous common building materials and exposed these materials to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. To aid in these analyses, we introduced a 'wash penalty factor' to quantify the degree to which contamination migrated into the bulk material by the action of the wash method. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Cs{sup +} bonded to negative charge sites on the surface of the mineral aggregate (used in concrete) so decontamination was improved by ion exchange with K{sup +}. Sr{sup 2+} is soluble and removed by water, while not bonding to aggregate or demonstrating solubility in the liquid asphalt. Eu{sup 3+} is precipitated and not removed in gentle wash but displays mobility within the pore space that suggests its presence as a colloid. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for {sup 137}Cs and {sup 152}Eu and 50- 80% for {sup 85}Sr. On concrete, Cs{sup +} bonds similarly to asphalt. Sr{sup 2+} bonds to the cement or precipitates from the alkaline pore water. Eu{sup 3+} sorbs to the cement and then precipitates. In brick, the results for Cs{sup +} and Sr{sup 2+} suggested that diffusion of ions from deeper in the coupon was important. Eu{sup 3+} is removed poorly due to precipitation. We will explain and report example wash penalty factors that vary from 0 to > 1 for the various methods and the implications for deciding when to implement wash down methods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life cycle Management of 324 Project High-Activity, Mixed/Low-Level Radioactive Waste - 20506

U.S. DOE contractor CH2M Hill Plateau Remediation Company (CHPRC) manages the 324 Building and is preparing to remotely excavate and disposition the radioactive soil beneath the building to allow further deactivation of the building. The 324 Building is a non-reactor Category 2 Nuclear Facility located in the 300 Area of the Hanford Site. Records indicate that in October 1986, approximately 516 liters of a concentrated liquid waste stream containing cesium-137 ({sup 137}Cs) and strontium-90 ({sup 90}Sr) spilled onto the floor of a hot cell, B-Cell, in the 324 Building. The spill contained an estimated 1.3 million curies (Ci) of radioactivity. A breach in the sump of B-Cell was discovered in November 2009 during characterization of the soil under the building. Exposure rates in excess of 10,000 R/hr were detected through a system of access pipes installed under the hot cell, and an estimated 1.557 E+05 Ci of {sup 137}Cs and 6.842 E+04 Ci of {sup 90}Sr are in the soil beneath B-Cell. The magnitude of the soil contamination below B-Cell represents one of the most challenging remediation activities in the DOE complex. The objective of CHPRC's 324 Project is to remotely excavate and disposition the highly contaminated soil under the hot cell so building deactivation and stabilization activities can resume. Depending on the volume and radioactivity of contaminated soil under B-Cell, the material will be dispositioned either at the Hanford Site's Environmental Restoration Disposal Facility (ERDF) or in grout monoliths that will be created in the hot cells (A, C and D) next to B-Cell during future building demolition activities. The current project scope includes installing structural supports under the walls of B-Cell and using remotely operated equipment to remove debris from the hot cell, remove debris mixed with grout on the floor, saw through and remove the cell floor and liner, and excavate contaminated soil under B-Cell to a depth of up to 3.66 meters (12 feet). Addition or removal of debris in A-Cell may be required to support B-Cell cleanout and excavation activities. The base approach is to disposition debris and soil bins in the Radiochemical Engineering Cell (REC) monoliths, and subsequently disposition the monoliths during building demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Perspectives on Response to an Abnormal Radiological Event [Slides]

On May 2, 2019, a sealed radioactive source containing cesium-137 was breached at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of personnel, large sections of the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY↗