Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Heating Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermochromic Halide Perovskite Windows with Ideal Transition Temperatures

Abstract Urban centers across the globe are responsible for a significant fraction of energy consumption and CO 2 emission. As urban centers continue to grow, the popularity of glass as cladding material in urban buildings is an alarming trend. Dynamic windows reduce heating and cooling loads in buildings by passive heating in cold seasons and mitigating solar heat gain in hot seasons. Here, reduced energy consumption in highly glazed buildings in a mesoscopic building energy model is demonstrated when thermochromic windows are employed. Savings are realized across eight disparate climate zones of the United States. The model is used to determine ideal critical transition temperatures of 20–27.5 °C for thermochromic windows based on metal halide perovskite materials. Ideal transition temperatures are realized experimentally in composite metal halide perovskite films composed of perovskite crystals and an adjacent reservoir phase. The transition temperature is controlled by cointercalating methanol, instead of water, with methylammonium iodide and tailoring the hydrogen‐bonding chemistry of the reservoir phase. Thermochromic windows based on metal halide perovskites represent a clear opportunity to mitigate the effects of energy‐hungry buildings.

14 SOLAR ENERGY↗

JPL Energy Consumption Program (ECP) documentation: A computer model simulating heating, cooling and energy loads in buildings

The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.

Lansing, F. L.↗

Building with integral solar-heat storage--Starkville, Mississippi

Column supporting roof also houses rock-storage bin of solar-energy system supplying more than half building space heating load. Conventional heaters supply hot water. Since bin is deeper and narrower than normal, individual pebble size was increased to keep airflow resistance at minimum.

Source record↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗

Site dependent factors affecting the economic feasibility of solar powered absorption cooling

A procedure was developed to evaluate the cost effectiveness of combining an absorption cycle chiller with a solar energy system. A basic assumption of the procedure is that a solar energy system exists for meeting the heating load of the building, and that the building must be cooled. The decision to be made is to either cool the building with a conventional vapor compression cycle chiller or to use the existing solar energy system to provide a heat input to the absorption chiller. Two methods of meeting the cooling load not supplied by solar energy were considered. In the first method, heat is supplied to the absorption chiller by a boiler using fossil fuel. In the second method, the load not met by solar energy is net by a conventional vapor compression chiller. In addition, the procedure can consider waste heat as another form of auxiliary energy. Commercial applications of solar cooling with an absorption chiller were found to be more cost effective than the residential applications. In general, it was found that the larger the chiller, the more economically feasible it would be. Also, it was found that a conventional vapor compression chiller is a viable alternative for the auxiliary cooling source, especially for the larger chillers. The results of the analysis gives a relative rating of the sites considered as to their economic feasibility of solar cooling.

Bartlett, J. C.↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Learning-Based Building Flexibility Estimation and Control to Improve Microgrid Economics and Resilience: Preprint

This paper proposes a learning-based building flexibility estimation and control framework to improve system economics and resilience. A data-driven building load flexibility model consisting of weather forecasting and estimating load consumption is proposed to quantify building heating, ventilation, and air conditioning (HVAC) load flexibility. A reinforcement learning-based microgrid controller is proposed to dispatch distributed generators, distributed energy resources, and build HVAC loads while taking flexibility information as one of the inputs. Simulation analysis is conducted on the model of a real microgrid in California. The effectiveness of the proposed learning-based building flexibility estimation and control in reducing microgrid energy costs and improving the sustainability of critical loads is demonstrated.

building load flexibility↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗