Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building automation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration and Evaluation of a Non-Invasive, Low-Cost, Strap-On Sensor for Natural Gas Meters

The U.S. General Services Administration (GSA) is interested in installing internet-connected, gas submeters to better understand gas consumption in its portfolio of buildings. The GSA in partnership with the National Renewable Energy Laboratory conducted a demonstration to assess a specific submeter technology. This technology was implemented at two GSA separate facilities located in Dallas, Texas. This demonstration evaluated hardware and software installations and integrations, data integrity and accuracy, and included an economic analysis. This demonstration evaluated a gas submeter technology provided by the vendor Vata Verks, who produces a non-invasive strap-on submeter. The company was founded with a mission to conserve water (and eventually gas) cheaply and simply, as explained on its website. The product intends to streamline submeter deployments for gas and water by eliminating most hardware costs while allowing for easy integration of submetered data into other systems such as the Building Automation System and removing tenant and building disruption This demonstration evaluated the product features when used on a gas utility meter.

03 NATURAL GAS↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Re-Envisioning RCx: Achieving Max Potential HVAC Controls Retrofits through Modernized BAS Hardware and Software

Most existing buildings have sub-optimal heating, ventilation, and air conditioning (HVAC) controls, resulting in wasted energy and occupant discomfort. Retro-commissioning (RCx) addresses many of these issues, but it is a lengthy and highly customized process. Limited capabilities of existing building automation system hardware restricts the scope of most RCx projects. Incentive programs consider building automation system (BAS) hardware retrofits to be high-capital investments and do not allow them in typical RCx programs. This paper describes work that the authors are leading to facilitate technical and market innovation in the BAS industry to unlock large savings in existing commercial buildings through deep retrofits of BAS hardware and software. California and New York research projects are demonstrating BAS retrofits leveraging the American Society of Heating, Refrigeration, and Air Conditioning Engineers’ (ASHRAE) new Guideline 36 high performance sequences of operation to achieve greater than 20 percent whole building energy savings, while saving costs and reducing risk through streamlined processes and standardization across BAS manufacturer product lines and across implementation practices. This paper describes market barriers that impede achieving deep savings from BAS retrofits in custom incentive and traditional RCx programs and presents a new maximum potential BAS retrofit model that addresses these barriers. The new model leverages the authors’ efforts in market enablement through open standards, BAS industry partnerships, and tools for cost-effective scaling that includes tools for project screening, savings calculations, and measurement and verification (M&V). This approach is widely applicable and will be ready for at-scale implementation within two years.

Paliaga, Gwelen↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Wi-Fi Location-Based Services (LBS) for Commercial Building Occupancy Sensing

From May 2019 through October 2022, this DOE-funded project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at two commercial buildings located in Minnesota and Wisconsin.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

Design Requirements and Software Specification for the Autonomous Energy Management Software System for Small Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems. Many of these buildings are small (<50,000 square feet), underserved, and use rooftop units for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the rooftop units heating and cooling set points, schedules, setbacks, and optimal start can result in 20 to 25 percent reduction in electricity consumption in small commercial buildings. In addition, improving demand flexibility of these buildings will result additional cost savings for the building owner. Therefore, the Department of Energy’s Building Technologies Office approved a project to address the needs for small commercial buildings. The project is led by Pacific Northwest National Laboratory (PNNL) with Intellimation LLC as the cooperative research and development agreement partner. The primary goal of the project is to develop and validate an autonomous energy management software (AEMS) system that will continuously optimize small commercial building operations by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. The work will leverage the vast experience of PNNL research and development staff who have over two decades of experience in developing and successfully transferring software technologies to the private sector. This solution will be jointly developed with Intellimation, a company that plans to use it to scale their building energy efficiency (EE) and grid services offering. Widespread deployment of the AEMS system will improve the EE and demand flexibility of the building commercial building stock. It should also support cities and states in meeting their climate change mitigation goals. This document describes the various EE and grid service features of the AEMS system, infrastructure and data required to implement those features, and how the features should be automated. It also details how the various features will be tested and validated, including field validation. The document also details what flexibility the users have and how they will be able to leverage those capabilities exercise those. The intent is to create an AEMS system that would support scalable deployment, requires minimal configuration, and is easy to maintain over its expected lifespan. The initial alpha release of AEMS system is planned for March 2023, and the beta release is planned for the summer of 2023. The final release is planned for March 2024. Section 2 of the report documents the relevant building types that AEMS is suitable for. Section 3 documents EE features that will be supported. It will also include the data requirements, hardware requirements, implementation details, and how EE features will be tested and validated. Grid service features will be documented in section 4, including data requirements, hardware requirements, implementation details, and how the services will be tested and validated. Planned next steps are described in section 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Modeling and Optimization of Building Energy Consumption: a Case Study

Installing sensors and Building Automation Systems (BAS) allows controlling the facility operations while generating data that can be analyzed for model development. This work focuses on data-driven modeling of the building to optimize energy consumption. The City of Orlando aims to reduce its energy consumption so, they provided us access to their BAS for data and studying the operation of its facilities. We selected a mid-size pilot building to conduct data analysis and modeling. We develop an Application Programming Interface (API) to login to the servers and scrape data. The scraped data contains features ranging from environmental conditions to equipment activity. This dataset is a time series so, it's handled in accordance and analyzed to investigate patterns and relations between data points that help choose parameters for predictive models for building and equipment. Finally, the models are optimized to reduce the energy consumption of the facility.

Grover, Divas↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

cyber-physical systems↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Can We Fix It Automatically? Development of Fault Auto-Correction Algorithms for HVAC and Lighting Systems

A fault detection and diagnostics (FDD) tool is a type of energy management and information system designed to continuously identify the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and application of automated analytics. Building owners and operators at the leading edge of technology adoption are using FDD tools to enable average whole-building portfolio savings of 8 percent. Although FDD tools can inform building operators of operational faults, currently a manual action is always required to correct faults and generate the associated energy savings. A subset of faults, however, such as biased sensors and manual override, can be addressed automatically, removing the need for operations and maintenance staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability, as well as the technical and economic performance, of FDD technologies. In this paper, we present the development of 10 innovative fault auto-correction algorithms for HVAC and lighting systems. When the auto-correction routine is triggered, it will overwrite the control setpoints or other variables (via BACnet or other protocol) to implement the intended changes. These algorithms are able to automatically correct the faults or improve the operation associated with an incorrectly programmed schedule, override manual control, sensor bias, control hunting, rogue zone, and less aggressive setpoints/setpoints setback. The paper will also discuss the implementation of the auto-correction algorithms in FDD software products.

Lin, Guanjing↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Data Driven Commercial Building Energy Code Compliance and Technology Inventory for New York City

Building Performance Standards (BPS) are gaining national traction. A BPS will require new processes in the design, construction, and operation of buildings that take the occupants into account and enable predictive analysis to ensure compliance with current and future GHG emissions caps. In New York City, most buildings over 25,000 square feet will be regulated by a BPS starting in 2024, regardless of whether it is new construction permitted under current energy codes or an existing building. This research is one of the first to begin the evaluation of a long-term series of building policies in the context of an open data ecosystem, in cooperation with city agencies. Existing building policies enacted in NYC have ranged from building energy benchmarking and labeling to energy audits to the regulation of GHG emission in buildings. Through the development of a dataset related to building technologies and energy consumption, this project can help to evaluate if meaningful conclusions can be drawn for the data that has been largely self-reported in compliance with city regulations. This project will also provide lessons learned from a deep dive into these types of datasets to provide best practices for municipalities or states seeking to embark on policies like those enacted in NYC. In addition, a Building Automation System (BAS) Stretch Standard of Care (SSOC) for owners, designers, and building operators will enable the measurement and predictive analysis of energy consumption and GHG emissions at the plant, system, or component level, in anticipation of regulated GHG limits on buildings based on energy use. The SSOC is expected to be suitable for use on a national level. The primary feature of an SSOC is a standardized format for a set of BAS points that can be used to control and to gather data from individual plants, systems, or components that are related to building energy consumption. This project examined how measurements compare to prescriptive or simulation-based energy code targets, finding little correlation between predictive 8760-hour energy modeling and actual energy consumption for a small sample (n=27) of buildings constructed after 2015. Other analysis found that, while large multifamily housing (MFH) buildings showed a general trend similar to predicted reductions in energy use from the implementation of model commercial energy codes, this trend was not evident in the office, K-12 school, and hotel use groups in NYC. No upward or downward trends in energy consumption were found when buildings were grouped by size. Energy audit data were analyzed and it appears that there is bias by audit company on measures recommended to clients. Further research should be performed to cross-analyze this with other attributes, such as building size, vintage, and number of stories. Analysis found that for 281 buildings that were permitted and completed after 2015 and had submitted benchmarking data in 2022, between 81% and 96% (by use group) were found to be in compliance with the 2024 to 2029 NYC BPS emission caps, and between 55% and 89% were in compliance with the 2030-2034 caps. This work is beneficial to the public in helping policymakers and building stakeholders better understand the wide-ranging implications of a BPS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗