Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

From roads to roofs: How urban and rural mobility influence building energy consumption

In this article, understanding the relationship between travel behavior and building energy use at an urban scale is crucial for developing effective energy management strategies. Mobility patterns significantly impact building occupancy, which in turn affects energy consumption. However, existing methods often focus on individual buildings, whereas geographical influences on energy usage are not adequately examined. This study addresses this gap by using transportation origin-destination (OD) data to estimate building occupancy and energy. The proposed method assigns OD trips from census block groups to the building level, incorporating building, travel survey, and census data to derive building occupancy profiles. This method was applied to urban and rural areas with 4062 buildings in 70 census block groups. We found that the OD-informed occupancy profile exhibits smoother energy consumption patterns compared with that of Department of Energy reference occupancy profiles. Our analysis reveals distinct building energy consumption patterns among groups with long and short commutes, emphasizing the effect of commute times and work schedules on residential energy usage. This framework is useful for practitioners in transportation agencies and utility companies, enabling the estimation of building energy based on mobility patterns. Overall, this study shows the potential of integrating transportation and building energy data to inform cross-sector energy management strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of WELL certification on occupant satisfaction and perceived health, well-being, and productivity: A multi-office pre- versus post-occupancy evaluation

The WELL Building Standard (WELL) is currently one of the most comprehensive building certification programs that aim to enhance the health and well-being of building occupants. However, there is a lack of systematic evaluation of the effectiveness of WELL in achieving its goal. This study investigates the impact of WELL certification on occupant satisfaction with the workplace and occupant perceived health, well-being, and productivity. More than 1300 pre- and post-occupancy survey responses provided by the nearly same cohort of occupants from six companies in North America were quantitatively analyzed. The results showed that transitioning to WELL certified offices from non-WELL certified offices had a positive impact on occupant satisfaction with the workplace and occupant perceived health, well-being, and productivity, with increases in means from pre-to post-occupancy being highly statistically significant. The majority of the studied occupant satisfaction parameters as well as occupant perceived mental health had large effect sizes. While they improved from pre-to post-occupancy, the analysis revealed small effect sizes for occupant perceived physical health and self-assessed productivity. The majority of the effect sizes for the perceived well-being parameters were large and medium. In addition to analyzing the survey responses in aggregate, the responses were examined at the individual company level to confirm the by-company and aggregate findings aligned.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of the DNAS framework expansion to occupant population synthesis

Research in occupant behaviour is now using a more elaborate framework of building occupant interaction. Researchers often face challenges in collecting data, particularly for the data to meet the minimum number of required data points and the data interoperability requirements. Researchers address the first issue with the synthetic population and the latter with data ontologies. While synthetic population is commonly used to address the first issue, data ontology development is used to address the latter. The two solutions are complementary to each other. One of the known ontologies in building occupant behaviour research is the Drivers-Needs-Actions-Systems (DNAS) ontology, which has been used by building modelers to describe energy-related occupant behaviour. This paper describes the ontology-based synthetic population generation that can be used in the agent-based modeling (ABM) applications. This paper considers multiple data sources, including ASHRAE Thermal Comfort DB II and IEA Annex 66 data sets. A case study of an office building is used to present the workflow of DNAS framework expansion, synthetic population generation, and agent-based modeling.

Chandra Putra, Handi↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Communication breakdown: Energy efficiency recommendations to address the disconnect between building operators and occupants

As technology advances, progressive building performance goals are met with ease and occupant behavior plays an increasingly significant role in preventing building operators from achieving those goals. However, removing occupants from participating in building control and operation is counterintuitive to the purpose of building operation. Occupant-centric control (OCC) has been suggested as a means of incorporating the occupant while simultaneously reducing the negative impact their behavior can have on building performance. As a result, operators are now tasked with incorporating OCC into their daily operation. The relationship between building occupants and operators is a critical component to OCC, and balancing occupant comfort and building performance. In this paper, we present findings from an international qualitative study of building operators with a focus on the operator and occupant relationship. This paper identifies the role operators play in OCC, how these relationships develop, and how these relationships impact building operation through two key research questions: What factors influence the quality of relationships between occupants and operators? How can the relationships between operators and occupants be improved? Subsequently, these questions revealed this relationship becomes strained when building performance is prioritized over comfort, occupants are ignored or uneducated, and feedback is negative or sparse. In short: there is a disconnection between operators and occupants. Here we propose several solutions including modifying job requirements to prioritize occupant comfort, educating occupants to make autonomous decisions that are not detrimental to operation, and creating effective communication channels for instances where operator intervention is required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Generating synthetic occupants for use in building performance simulation

Occupant behaviour simulation frameworks can employ synthetic populations to characterize occupancy and behavioural patterns in buildings based on observed demographic data at a certain geographical location. For buildings, very few synthetic occupant populations have been generated. This paper uses a Bayesian Networks (BN) structural learning approach to synthesize populations of occupants in a multi-family housing case study. Two additional cases of office occupants and senior housing residents are considered as a cross-case comparison. Furthermore, we draw upon the extended version of drivers-needs-actions-systems (DNAS) framework to guide the selection of variables and data imputation. Our results show that the BN approach is powerful in learning the structure of data sets. The synthetic data sets successfully match the joint distributions of the underlying combined data sets. Experiments on the multi-family housing particularly show better performance than the office and senior housing cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Plug Load Management Through Occupant Engagement at Washington State University

To decrease costs and improve building occupant safety, Washington State University (WSU) began planning a plug load management campaign in 2020, with implementation beginning in 2021. This case study describes the campaign's goals, approach, and results over the past 5 years, ultimately showing that occupant- and behavior-focused strategies can meaningfully reduce plug load energy use while improving health and safety.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using spacecraft trace contaminant control systems to cure sick building syndrome

Many residential and commercial buildings with centralized, recirculating, heating ventilation and air conditioning systems suffer from 'Sick Building Syndrome.' Ventilation rates are reduced to save energy costs, synthetic building materials off-gas contaminants, and unsafe levels of volatile organic compounds (VOC's) accumulate. These unsafe levels of contaminants can cause irritation of eyes and throat, fatigue and dizziness to building occupants. Increased ventilation, the primary method of treating Sick Building Syndrome is expensive (due to increased energy costs) and recently, the effectiveness of increased ventilation has been questioned. On spacecraft venting is not allowed, so the primary methods of air quality control are; source control, active filtering, and destruction of VOC's. Four non-venting contaminant removal technologies; strict material selection to provide source control, ambient temperature catalytic oxidation, photocatalytic oxidation, and uptake by higher plants, may have potential application for indoor air quality control.

Graf, John C.↗

A multi-level load shape clustering and disaggregation approach to characterize patterns of energy consumption behavior

This study presents representative electrical load shapes, disaggregated to the end-use level, for over 5000 customer clusters across California’s residential, commercial, industrial and agricultural sectors. We developed a novel, multi-level load shape clustering approach for residential and commercial sectors leveraging interval meter data for over 350,000 California utility customers collected as a part of the Phase 4 California Demand Response (DR) Potential Study. The clustering approach allowed us to identify typical consumption patterns and categorize customers based on their daily load shape displayed throughout the year. For example, we were able to identify customers with particular energy technologies such as electric vehicles and rooftop solar, as well as building occupancy types such as restaurants, grocery stores and even unoccupied buildings, based solely on whole-building interval data. We then combined the load shape-based clusters with other customer information including building type, climate, geographical area, total consumption and low-income status, to create a set of customer clusters based on both demographics and usage patterns. Total cluster electricity demand was then disaggregated into a wide variety of end-uses using weather normalization and other publicly available end-use load shape datasets. The resulting disaggregated cluster load shapes will be released in anonymized form as part of the Phase 4 DR Potential Study. They will have wide-ranging applications in energy research and policy analysis, including estimation of energy efficiency (EE) and DR potential on the end-use level, time-dependent valuation of EE savings, building stock modeling, and developing customer targeting strategies for EE and DR programs.

Murthy, Samanvitha↗

Harvesting the low-hanging fruit of high energy savings -- Virtual Occupancy using Wi-Fi Data

Approximately 20% of primary energy consumed in the U.S. is attributed to HVAC use. Ideally, HVAC operation would be driven by actual building occupancy, but lack of reliable occupancy information often results in the use of conservative static schedules. This disparity is even more pronounced in a college campus, where the function of each space differs by building (classrooms, offices, libraries) and the class schedules change frequently -- every semester, day of week, and hour. While several research papers propose the use of counts of the Wi-Fi connections (e.g., phones, computers) as a proxy for occupancy, few real-world implementations exist. This paper describes the development and deployment of an open-source Wi-Fi-to-Occupancy software library in 65 buildings of a college campus, and the planned integration with the building energy management and control system at the building scale. Over a year of Wi-Fi data was gathered into distinct academic periods, including fall and spring semester, academic breaks, and summer sessions. Patterns such as students moving between classrooms, closing laptops before exams, etc., can be visualized from the data. Approximating occupancy from Wi-Fi data presents challenges which we address in this project -- for example, identifying static devices, or estimating the ratio of devices per person. Utilizing real-time occupancy data to inform optimal HVAC schedules and ventilation rates creates the potential to identify and reduce energy waste. Other potential applications include forecasting occupancy, and using Wi-Fi data to predict peak demands. Finally, the paper discusses how to easily scale these tools to other buildings.

Pritoni, Marco↗