Search NASASearch

SEARCH · Search NASA

Results for “CAPILLARY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Direct measurement of capillary blood pressure in the human lip

In this study, we developed and tested a new procedure for measuring microcirculatory blood pressures above heart level in humans. Capillary and postcapillary venule blood pressures were measured directly in 13 human subjects by use of the servonulling micropressure technique adapted for micropuncture of lip capillaries. Pressure waveforms were recorded in 40 separate capillary vessels and 14 separate postcapillary venules over periods ranging from 5 to 64 s. Localization and determination of capillary and postcapillary vessels were ascertained anatomically before pressure measurements. Capillary pressure was 33.2 +/- 1.5 (SE) mm Hg in lips of subjects seated upright. Repeated micropunctures of the same vessel gave an average coefficient of variation of 0.072. Postcapillary venule pressure was 18.9 +/- 1.6 mm Hg. This procedure produces a direct and reproducible means of measuring microvascular blood pressures in a vascular bed above heart level in humans.

Parazynski, S. E.

Pulmonary diffusing capacity, capillary blood volume, and cardiac output during sustained microgravity

We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.

Prisk, G. K.

Capillary Movement in Granular Beds in Microgravity

Understanding the dynamics of capillary flow through unsaturated porous media is very important for the development of an effective water and nutrient delivery system for growing plants in microgravity and chemical engineering applications. Experiments were conducted on the Space Shuttle during the STS-63 mission using three experimental cuvettes called "Capillary Testbed-M." These experiments studied the effect of bead diameter on capillary flow by comparing the capillary flow in three different granular beds. It was observed that the speed of water propagation in the granular bed consisting of 1.5 mm diameter particles was less than that in the bed consisting of 1.0 mm. diameter particles. Such results contradict the existing theory of capillary water propagation in granular beds. It was found also that in microgravity water propagates independently in adjacent layers of a layered granular bed .

Yendler, Boris S.

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are conducted. Tests include heat load to one evaporator only, even heat loads to both evaporators and uneven heat load to both evaporators. Results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event Because the evaporator can tolerate vapor bubbles, the loop may continue to work and reach a new steady state at a higher operating temperature. The loop may even function with a modest increase in the heat load past the capillary limit With a heat load to only one evaporator, the capillary limit can be identified by rapid increases in the operating temperature and in the temperature difference between the evaporator and the CC. However, it is more difficult to tell when the capillary limit is exceeded if heat loads are applied to both evaporators. In all cases, the loop can recover by reducing the heat load to the loop.

Ku, Jentung

High lung volume increases stress failure in pulmonary capillaries

We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological mechanism for other studies showing increased capillary permeability at high states of lung inflation.

Non-NASA Center

Capillary Pressure of a Liquid Between Uniform Spheres Arranged in a Square-Packed Layer

The capillary pressure in the pores defined by equidimensional close-packed spheres is analyzed numerically. In the absence of gravity the menisci shapes are constructed using Surface Evolver code. This permits calculation the free surface mean curvature and hence the capillary pressure. The dependences of capillary pressure on the liquid volume constructed here for a set of contact angles allow one to determine the evolution of basic capillary characteristics under quasi-static infiltration and drainage. The maximum pressure difference between liquid and gas required for a meniscus passing through a pore is calculated and compared with that for hexagonal packing and with approximate solution given by Mason and Morrow [l]. The lower and upper critical liquid volumes that determine the stability limits for the equilibrium capillary liquid in contact with square packed array of spheres are tabulated for a set of contact angles.

Alexader, J. Iwan D.

Study of a heat rejection system using capillary pumping

Results of an analytical study investigating the application of capillary pumping to the heat rejection loop of an advanced Rankine cycle power conversion system are presented. The feasibility of the concept of capillary pumping as an alternate to electromagnetic pumping is analytically demonstrated. Capillary pumping is shown to provide a potential for weight and electrical power saving and reliability through the use of redundant systems. A screen wick pump design with arterial feed lines was analytically developed. Advantages of this design are high thermodynamic and hydrodynamic efficiency, which provide a lightweight easily packaged system. Operational problems were identified which must be solved for successful application of capillary pumping. The most important are the development of start up and shutdown procedures, and development of a means of keeping noncondensibles from the system and of earth-bound testing procedures.

Neal, L. G.

On two-dimensional packets of capillary-gravity waves

The motion of a two-dimensional packet of capillary-gravity waves on water of finite depth is studied. The evolution of a packet is described by two partial differential equations: the nonlinear Schroedinger equation with a forcing term and a linear equation, which is of either elliptic or hyperbolic type depending on whether the group velocity of the capillary-gravity wave is less than or greater than the velocity of long gravity waves. These equations are used to examine the stability of the Stokes capillary-gravity wave train. The analysis reveals the existence of a resonant interaction between a capillary-gravity wave and a long gravity wave. The interaction requires that the liquid depth be small in comparison with the wavelength of the (long) gravity waves and the evolution equations describing the dynamics of this interaction are derived.

Djordjevic, V. D.

Capillary acquisition devices for high-performance vehicles: Executive summary

Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.

Blatt, M. H.

The Capillary Pumped Loop (CPL) GAS experiment G-471

The Capillary Pumped Loop (CPL) experiment, 6-471 is a thermal control system with high density heat acquisition and transport capability. The CPL consists of two capillary pumped evaporators with integral heaters, a fluid loop charged with ammonia (NH3), a condenser plate (heat sink), and various control electronics. The purpose of the experiment is to demonstrate the capability of a capillary pumped system under zero gravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. A unique feature of the CPL is the capillary pumps, which contain no moving parts. Each pump contains a wick of porous material which is saturated with the working fluid (anhydrous ammonia). As heat is added to the fluid, it evaporates and travels to the condenser, thus transporting the heat (via the latent heat of vaporization) from the heat source to its sink at nearly a constant temperature. The evaporation process produces the pressure gradient or pumping action that circulates the fluid. This is the same principal that plants and trees use to transport water and nutrients from their roots to their leaves against gravity. The difference is that the CPL employs a closed system to return the fluid directly to the pumps, whereas "Mother Nature'' has an open system where the fluid is indirectly returned to the roots by condensation of water from the clouds in the form of rain. It should be noted that the CPL experiment was the first flight of a thermal control system of this type. It was also the first shuttle experiment from the Space Station Advanced Development Program.

Dan Butler

Capillary-Condenser-Pumped Heat-Transfer Loop

Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

Silverstein, Calvin C.

Transient studies of capillary-induced flow

This paper presents the numerical and experimental results of a study performed on the transient rise of fluid in a capillary tube. The capillary tube problem provides an excellent mechanism from which to launch an investigation into the transient flow of a fluid in a porous wick structure where capillary forces must balance both adverse gravitational effects and frictional losses. For the study, a capillary tube, initially charged with a small volume of water, was lowered into a pool of water. The behavior of the column of fluid during the transient that followed as more water entered the tube from the pool was both numerically and experimentally studied.

Reagan, M. K.

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura

Capillary Flow in Containers of Polygonal Section: Theory and Experiment

An improved understanding of the large-length-scale capillary flows arising in a low-gravity environment is critical to that engineering community concerned with the design and analysis of spacecraft fluids management systems. Because a significant portion of liquid behavior in spacecraft is capillary dominated it is natural to consider designs that best exploit the spontaneous character of such flows. In the present work, a recently verified asymptotic analysis is extended to approximate spontaneous capillary flows in a large class of cylindrical containers of irregular polygonal section experiencing a step reduction in gravitational acceleration. Drop tower tests are conducted using partially-filled irregular triangular containers for comparison with the theoretical predictions. The degree to which the experimental data agree with the theory is a testament to the robustness of the basic analytical assumption of predominantly parallel flow. As a result, the closed form analytical expressions presented serve as simple, accurate tools for predicting bulk flow characteristics essential to practical low-g system design and analysis. Equations for predicting corner wetting rates, total container flow rates, and transient surfaces shapes are provided that are relevant also to terrestrial applications such as capillary flow in porous media.

Weislogel, Mark M.

Investigation of Capillary Limit in a Loop Heat Pipe

This paper presets an experimental study on the capillary limit of a loop heat pipe (LHP) at low powers. The slow thermal response of the loop at low powers made it possible to observe interactions among various components after the capillary limit was exceeded. The capillary limit at low powers was achieved by imposing additional pressure drops on the vapor line through the use of a metering valve. A differential pressure transducer was also used to measure the pressure drop across the evaporator and the compensation chamber (CC). Test results show that when the capillary limit is exceeded, vapor will penetrate the primary wick, resulting in a partial dry-out of the evaporator and a rapid increase of the CC temperature. Because the evaporator can tolerate vapor bubbles, the LHP will continue to function and may reach a new steady state at the higher temperature. Thus, the LHP will exhibit a graceful degradation in performance rather than a complete failure. Moreover, the loop can recover from a partial dry-out by reducing the heat load without a re-start.

Ku, Jentung

Short-term reversibility of ultrastructural changes in pulmonary capillaries caused by stress failure

We previously showed that when the pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to determine whether some of the ultrastructural changes are rapidly reversible when the capillary pressure is reduced. To test this, the Ptm was raised to 52.5 cmH2O for 1 min of blood perfusion and then reduced to 12.5 cmH2O for 3 min of saline-dextran perfusion, followed by intravascular fixation at the same pressure. In another group of animals, the pressure was elevated for 1 min of blood and 3 min of saline-dextran before being reduced. The results were compared with previous studies in which the capillary pressures were maintained elevated at 52.5 cmH2O during the entire procedure. Control studies were also done at sustained low pressures. The results showed that the number of endothelial and epithelial breaks per millimeter and the total fraction area of the breaks were reduced when the pressure was lowered. For example, the number of endothelial breaks per millimeter decreased from 7.1 +/- 2.1 to 2.4 +/- 0.7, and the number of epithelial breaks per millimeter fell from 11.4 +/- 3.7 to 3.4 +/- 0.7. There was evidence that the breaks that closed were those that were initially small and were associated with an intact basement membrane. The results suggest that cells can move along their underlying matrix by rapid disengagement and reattachment of cell adhesion molecules, causing breaks to open or close within minutes.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center

The Capillary Flow Experiments Aboard the International Space Station: Increments 9-15

This report provides a summary of the experimental, analytical, and numerical results of the Capillary Flow Experiment (CFE) performed aboard the International Space Station (ISS). The experiments were conducted in space beginning with Increment 9 through Increment 16, beginning August 2004 and ending December 2007. Both primary and extra science experiments were conducted during 19 operations performed by 7 astronauts including: M. Fincke, W. McArthur, J. Williams, S. Williams, M. Lopez-Alegria, C. Anderson, and P. Whitson. CFE consists of 6 approximately 1 to 2 kg handheld experiment units designed to investigate a selection of capillary phenomena of fundamental and applied importance, such as large length scale contact line dynamics (CFE-Contact Line), critical wetting in discontinuous structures (CFE-Vane Gap), and capillary flows and passive phase separations in complex containers (CFE-Interior Corner Flow). Highly quantitative video from the simply performed flight experiments provide data helpful in benchmarking numerical methods, confirming theoretical models, and guiding new model development. In an extensive executive summary, a brief history of the experiment is reviewed before introducing the science investigated. A selection of experimental results and comparisons with both analytic and numerical predictions is given. The subsequent chapters provide additional details of the experimental and analytical methods developed and employed. These include current presentations of the state of the data reduction which we anticipate will continue throughout the year and culminate in several more publications. An extensive appendix is used to provide support material such as an experiment history, dissemination items to date (CFE publication, etc.), detailed design drawings, and crew procedures. Despite the simple nature of the experiments and procedures, many of the experimental results may be practically employed to enhance the design of spacecraft engineering systems involving capillary interface dynamics.

Jenson, Ryan M.

Demonstration of Nautilus Centripetal Capillary Condenser Technology

This paper describes the results of a proof of concept effort for development of a Nautilus Centripetal Capillary Condenser (NCCC or NC3) used for microgravity compatible water recovery from moist air with integral passive phase separation. Removal of liquid condensate from the air stream exiting a condenser is readily performed here on Earth. In order to perform this function in space however, without gravity or mechanical action, other tactics including utilization of inertial, drag and capillary forces are required. Within the NC3, liquid water forms via condensation on cold condenser surfaces as humid air passes along multiple spiral channels, each in its own plane, all together forming a stacked plate assembly. Non-mechanical inertial forces are employed to transfer condensate, as it forms, via centripetal action to the outer perimeter of each channel. A V-shaped groove, constructed on this outer edge of the spiral channel, increases local capillary forces thereby retaining the liquid. Air drag then pulls the liquid along to a collection region near the center of the device. Dry air produced by each parallel spiral channel is combined in a common orthogonal, out-of-plane conduit passing down the axial center of the stacked device. Similarly, the parallel condensate streams are combined and removed from the condenser/separator through yet another out-of-plane axial conduit. NC3 is an integration of conventional finned condenser operation, combined with static phase separation and capillary transport phenomena. A Mars' transit mission would be a logical application for this technology where gravity is absent and the use of vibrating, energy-intensive, motor-driven centrifugal separators is undesired. Here a vapor stream from either the Heat Melt Compactor or the Carbon dioxide Reduction Assembly, for example, would be dried to a dew point of 10 deg using a passive NC3 condenser/separator with the precious water condensate recycled to the water bus.

Separator