Search NASA⌕ Search

SEARCH · Search NASA

Results for “CAPILLARY CIRCULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermocapillary flow with evaporation and condensation at low gravity. Part 2: Deformable surface

The free surface behavior of a volatile wetting liquid at low gravity is studied using scaling and numerical techniques. An open cavity model, which was applied in part 1 to investigate fluid flow and heat transfer in non-deforming pores, is used to evaluate the influence of convection on surface morphology with length scales and subcooling/superheating limits of 1 less than or equal to D less than or equal to 10(exp 2) microns and approximately 1 K, respectively. Results show that the menisci shapes of highly wetting fluids are sensitive to thermocapillary flow and to a lesser extent the recoil force associated with evaporation and condensation. With subcooling, thermocapillarity produces a suction about the pore centerline that promotes loss of mechanical equilibrium, while condensation exerts an opposing force that under some conditions offsets this destabilizing influence. With superheating, thermocapillarity and evaporation act in the same direction and mutually foster surface stability. All of these trends are magnified by high capillary and Biot numbers, and the stronger circulation intensities associated with small contact angles. These phenomena strongly depend on the thermal and interfacial equilibrium between the liquid and vapor, and have important ramifications for systems designed to maintain a pressure differential across a porous surface.

Schmidt, G. R.↗

Numerical analysis of Microgravity Bubble Separation in Open Channels with ISS Bemchmarks

Spacecraft fluid systems often require specific considerations to operate in a manner similar to those on Earth. For instance, an open wedge shaped channel can serve as a pathway for passively separating bubbles from a liquid in a two phase flow, analogous to buoyancy effects on Earth. As the bubbles merge within the channel, they become increasingly confined in the wedge, driving them upwards and outwards toward the free surface due to capillary forces. These same forces ensure coalescence and allow the bubbles to escape through the free surface. However, in low gravity environments, a challenge arises when bubbles are not sufficiently large. Under such conditions, the bubbles tend to follow trajectories near their inscribed elevations, never fully leaving the liquid. Such unseparated bubbles can lead to downstream pump failure, cavitation, flow instabilities, dryout, and other adverse effects aboard spacecraft. Understanding and exploiting the underlying mechanisms behind this behavior is crucial for enhancing the reliability of passive capillary fluids management in space applications, including cryogenic and storable fuels transport, thermal fluids circulation, water recycling for life support, plant watering systems, and more. The joint German Aerospace Center (DLR) and NASA Capillary Channel Flow (CCF) experiment conducted on the International Space Station has provided an extensive publicly available database documenting such phenomena (https://science.nasa.gov/physical sciences informatics psi). Leveraging this resource, we aim to establish benchmarks for our numerical investigation of zero gravity bubbly two phase flow in open wedge channels. Specifically, we seek to quantitatively understand the mechanisms governing ‘inscribed’ bubble motion, considering the apparent interplay of two competing forces: Saffman lift (causing upward/outward motion) and the Magnus effect (causing downward/inward motion). Our cross cutting findings directly inform the development of robust passive phase separation methods within spacecraft plumbing systems.

bubble↗

Design of an advanced two-phase capillary cold plate

The functional principles and implementation of capillary pumped loop (CPL) two phase heat transport system for various elements of the Space Station program are described. Circulation of the working fluid by the surface-tension forces in a fine-pore capillary wick is the core principle of CPL systems. The liquid, usually NH3 at the moment, is changed into a vapor by heat absorption at one end of the loop, and the vapor is carrried back along the wick by the surface tension within the wick. NASA specifications and the results of mechanical and thermal tests for prototype cold plate and the capillary pump designs are outlined. The CPL is targeted for installation on free-flying platforms, attached payloads, and power subsystem thermal control systems.

Chalmers, D. R.↗

Technique for Configuring an Actively Cooled Thermal Shield in a Flight System

Broad area cooling shields are a mass-efficient alternative to conductively cooled thermal radiation shielding. The shield would actively intercept a large portion of incident thermal radiation and transport the heat away using cryogenic helium gas. The design concept consists of a conductive and conformable surface that maximizes heat transfer and formability. Broad Area Cooled (BAC) shields could potentially provide considerable mass savings for spaceflight applications by eliminating the need for a rigid thermal radiation shield for cryogen tanks. The BAC consists of a network of capillary tubes that are thermally connected to a conductive shield material. Chilled helium gas is circulated through the network and transports unwanted heat away from the cryogen tanks. The cryogenic helium gas is pumped and chilled simultaneously using a specialized pulse-tube cryocooler, which further improves the mass efficiency of the system. By reducing the thermal environment temperature from 300 to 100 K, the radiative heat load on a cryogen tank could be reduced by an order of magnitude. For a cryogenic liquid propellant scenario of oxygen and hydrogen, the boiloff of hydrogen would be significantly reduced and completely eliminated for oxygen. A major challenge in implementing this technology on large tanks is that the BAC system must be easily scalable from lab demonstrations to full-scale missions. Also, the BAC shield must be conformable to complex shapes like spheres without losing the ability to maintain constant temperature throughout. The initial design maximizes thermal conductivity between the capillary tube and the conductive radiation shielding by using thin, corrugated aluminum foil with the tube running transverse to the folds. This configuration has the added benefit of enabling the foil to stretch and contract longitudinally. This allows the BAC to conform to the complex curvature of a cryogen tank, which is key to its success. To demonstrate a BAC shield system with minimal impact to current cryogen tank designs, the shielding must be applied after the final assembly of the tank and supporting structure. One method is to pre-fabricate the shield in long strips. A spool of corrugated aluminum foil with a thermally sunk aluminum capillary running through the center could then be simply wound around the cryogen tanks and encapsulated within the multi-layer insulation (MLI) blanket. Then, on orbit, the BAC would intercept thermal radiation coming in through the MLI and transport it away from the cryogen tanks. An optimization of the design could be done to take into account mass savings from thinner MLI blankets, eliminating solid thermal shields, and ultimately, a reduction in the required cryogen tank size.

Barkfknecht, Peter↗

Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

Begin, R.↗

Measurement of net whole-body transcapillary fluid transport and effective vascular compliance in humans

BACKGROUND: Net whole-body transcapillary fluid transport (TFT) between the circulation and the interstitial (extravascular) space may be calculated as: IV - deltaPV - UV - IL, where IV=infused or ingested volume (when applicable), deltaPV = change in plasma volume, UV=urine volume, and IL=insensible loss. RESULTS: Infusion of 30 mL/kg isotonic saline over 25 minutes increased supine TFT from a basal capillary reabsorption of -106+/-24 mL/h (mean+/-SE) to a net filtration of 1,229+/-124 mL/h. One hour after infusion, reabsorption of -236+/-102 mL/h was seen, and control reabsorption levels returned by 3 hours. Four hours of 30 mm Hg lower body negative pressure (LBNP) elicited no net TFT, probably because of upper body reabsorptive compensation for lower body capillary filtration. When ingestion of 1 L of isotonic saline accompanied LBNP, filtration of 145+/-10 mL/h occurred. Reabsorption of extravascular fluid into the circulation always followed LBNP. CONCLUSION: Application of this technique could aid understanding of physiologic conditions, experimental interventions, disease states, and therapies that cause or are influenced by fluid shifts between intravascular and interstitial compartments.

NASA Center JSC↗

Capillary-Effect Root-Environment System

Capillary-effect root-environment system (CERES) is experimental apparatus for growing plants in nutrient solutions. Solution circulated at slight tension in cavity filled with plastic screen and covered by porous plastic membrane. By adsorptive attraction, root draws solution through membrane. Conceived for use in microgravity of space, also finds terrestrial application in germinating seedlings, because it protects them from extremes of temperature, moisture, and soil pH and from overexposure to fertilizers and herbicides.

Wright, Bruce D.↗

Design and testing of a high power spacecraft thermal management system

The design and test results are presented of an ammonia hybrid capillary pumped loop thermal control system which could be used for heat acquisition and transport on future large space platforms and attached payloads, such as those associated with the NASA Space Station. The High Power Spacecraft Thermal Management System (HPSTM) can operate as either a passive, capillary pumped two phase thermal control system, or, when additional pressure head is required, as a mechanically pumped loop. Testing has shown that in the capillary mode, the HPSTM evaporators can acquire a total heat load of between 600 W and 24 kW, transported over 10 meters, at a maximum heat flux density of 4.3 W/sq cm. With the mechanical pump circulating the ammonia, a heat acquisition potential of 52 kW was demonstrated for 15 minutes without an evaporator failure. These results represent a significant improvement over the maximum transport capability previously displayed in other capillary systems. The HPSTM system still retains the proven capillary capabilities of heat load sharing and flow control between evaporator plates, rapid power cycling, and nonuniform heating in both the capillary and hybrid operating modes.

Mccabe, Michael E., Jr.↗

MR imaging of hand microcirculation as a potential tool for space glove testing and design

The task of evaluating and designing space gloves requires accurate biomechanical characterization of the hand. The availability of magnetic resonance (MR) imaging has created new opportunities for in vivo analysis of physiological phenomena such as the relationship between circulation and fatigue. An MR imaging technique originally proposed to quantitatively evaluate cerebral perfusion has been modified to evaluate the capillary microcirculation in hand muscles. An experimental protocol was developed to acquire perfusion-weighted images in the hand before and after various levels of exercise. Preliminary results on the feasibility of applying the MR imaging technique to the study of microcirculation and fatigue in the hand are presented. The potential of this method for space glove testing and design is also discussed.

Peterson, Steven W.↗

Description of concept and first feasibility test results of a life support subsystem of the Botany Facility based on water reclamation

The Botany Facility allows the growth of higher plants and fungi over a period of 6 months maximum. It is a payload planned for the second flight of the Eureca platform around 1990. Major tasks of the Life Support Subsystem (LSS) of the Botany Facility include the control of the pressure and composition of the atmosphere within the plant/fungi growth chambers, control of the temperature and humidity of the air and the regulation of the soil water content within specified limits. Previous studies have shown that various LSS concepts are feasible ranging from heavy, simple and cheap to light, complex and expensive solutions. A summary of those concepts is given. A new approach to accomplish control of the temperature and humidity of the air within the growth chambers based on water reclamation is discussed. This reclamation is achieved by condensation with a heat pump and capillary transport of the condensate back into the soil of the individual growth chamber. Some analytical estimates are given in order to obtain guidelines for circulation flow rates and to determine the specific power consumption.

Loeser, H. R.↗

Pulmonary decompression sickness at altitude: early symptoms and circulating gas emboli

INTRODUCTION: Pulmonary altitude decompression sickness (DCS) is a rare condition. 'Chokes' which are characterized by the triad of substernal pain, cough, and dyspnea, are considered to be associated with severe accumulation of gas bubbles in the pulmonary capillaries and may rapidly develop into a life-threatening medical emergency. This study was aimed at characterizing early symptomatology and the appearance of venous gas emboli (VGE). METHODS: Symptoms of simulated-altitude DCS and VGE (with echo-imaging ultrasound) were analyzed in 468 subjects who participated in 22 high altitude hypobaric chamber research protocols from 1983 to 2001 at Brooks Air Force Base, TX. RESULTS: Of 2525 subject-exposures to simulated altitude, 1030 (41%) had symptoms of DCS. Only 29 of those included DCS-related pulmonary symptoms. Of these, only 3 subjects had all three pulmonary symptoms of chokes; 9 subjects had two of the pulmonary symptoms; and 17 subjects had only one. Of the 29 subject-exposures with pulmonary symptoms, 27 had VGE and 21 had severe VGE. The mean onset times of VGE and symptoms in the 29 subject-exposures were 42 +/- 30 min and 109 +/- 61 min, respectively. In 15 subjects, the symptoms disappeared during recompression to ground level followed by 2 h of oxygen breathing. In the remaining 14 cases, the symptoms disappeared with immediate hyperbaric oxygen treatment. CONCLUSIONS: Pulmonary altitude DCS or chokes is confirmed to be a rare condition. Our data showed that when diagnosed early, recompression to ground level pressure and/or hyperbaric oxygen treatment was 100% successful in resolving the symptoms.

Non-NASA Center↗

Orthostatic stress is necessary to maintain the dynamic range of cardiovascular control in space

In the upright position, gravity fills the low-pressure systems of human circulation with blood and interstitial fluid in the sections below the diaphragm. Without gravity one pressure component in the vessels disappears and the relationship between hydrostatic pressure and oncotic pressure, which regulates fluid passage across the capillary endothelium in the terminal vascular bed, shifts constantly. The visible consequences of this are a puffy face and "bird" legs. The plasma volume shrinks in space and the range of cardiovascular control is reduced. When they stand up for the first time after landing, 30-50% of astronauts suffer from orthostatic intolerance. It remains unclear whether microgravity impairs cardiovascular reflexes, or whether it is the altered volume status that causes the cardiovascular instability following space flight. Lower body negative pressure was used in several space missions to stimulate the cardiovascular reflexes before, during and after a space flight. The results show that cardiovascular reflexes are maintained in microgravity. However, the astronauts' volume status changed in space, towards a volume-retracted state, as measurements of fluid-regulating hormones have shown. It can be hypothesized that the control of circulation and body fluid homeostasis in humans is adapted to their upright posture in the Earth's gravitational field. Autonomic control regulates fluid distribution to maintain the blood pressure in that posture, which most of us have to cope with for two-thirds of the day. A determined amount of interstitial volume is necessary to maintain the dynamic range of cardiovascular control in the upright posture; otherwise orthostatic intolerance may occur more often.

manned↗

Specialized physiological studies in support of manned space flight

Breath-by-breath measurements of pulmonary capillary O2 transfer and ventilation with a box-balloon spirometer and mass spectrometer were made on 3 subjects before, during and after 10 min of lower body negative pressure (LBNP) at -20, -40 and -60 Torr with arterial samples at -60 Torr. Deficits in blood O2 stores (O2B) were noted during LBNP with repayment of O2B during recovery being related to the intensity of LBNP stress. Concurrent calf volume, measured with a Hg strain gauge, decreased towards baseline well before the peak rise in pulmonary capillary O2 transfer after the release of LBNP which signified that O2B changes were related to blood volume shifts. The return of O2-depleted pooled blood to the central circulation during the first min. of recovery caused significant stress-related hyperpnea which peaked near 30 sec. and returned to near baseline after the first min. Three-compartment lung model analyses indicated an increase in the ventilated unperfused lung fraction from 0.09 to 0.17 with the effective compartment decreasing from 0.83 to 0.77. It appears that the 30% increase in ventilation equivalent was primarily the result of less effective lung perfusion during the LBNP.

Source record↗

Pulmonary function in space

The lung is exquisitely sensitive to gravity, and so it is of interest to know how its function is altered in the weightlessness of space. Studies on National Aeronautics and Space Administration (NASA) Spacelabs during the last 4 years have provided the first comprehensive data on the extensive changes in pulmonary function that occur in sustained microgravity. Measurements of pulmonary function were made on astronauts during space shuttle flights lasting 9 and 14 days and were compared with extensive ground-based measurements before and after the flights. Compared with preflight measurements, cardiac output increased by 18% during space flight, and stroke volume increased by 46%. Paradoxically, the increase in stroke volume occurred in the face of reductions in central venous pressure and circulating blood volume. Diffusing capacity increased by 28%, and the increase in the diffusing capacity of the alveolar membrane was unexpectedly large based on findings in normal gravity. The change in the alveolar membrane may reflect the effects of uniform filling of the pulmonary capillary bed. Distributions of blood flow and ventilation throughout the lung were more uniform in space, but some unevenness remained, indicating the importance of nongravitational factors. A surprising finding was that airway closing volume was approximately the same in microgravity and in normal gravity, emphasizing the importance of mechanical properties of the airways in determining whether they close. Residual volume was unexpectedly reduced by 18% in microgravity, possibly because of uniform alveolar expansion. The findings indicate that pulmonary function is greatly altered in microgravity, but none of the changes observed so far will apparently limit long-term space flight. In addition, the data help to clarify how gravity affects pulmonary function in the normal gravity environment on Earth.

short duration↗

Whole-body mathematical model for simulating intracranial pressure dynamics

A whole-body mathematical model (10) for simulating intracranial pressure dynamics. In one embodiment, model (10) includes 17 interacting compartments, of which nine lie entirely outside of intracranial vault (14). Compartments (F) and (T) are defined to distinguish ventricular from extraventricular CSF. The vasculature of the intracranial system within cranial vault (14) is also subdivided into five compartments (A, C, P, V, and S, respectively) representing the intracranial arteries, capillaries, choroid plexus, veins, and venous sinus. The body's extracranial systemic vasculature is divided into six compartments (I, J, O, Z, D, and X, respectively) representing the arteries, capillaries, and veins of the central body and the lower body. Compartments (G) and (B) include tissue and the associated interstitial fluid in the intracranial and lower regions. Compartment (Y) is a composite involving the tissues, organs, and pulmonary circulation of the central body and compartment (M) represents the external environment.

Lakin, William D.↗

Design and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment

This paper details the flight configuration and pre-flight performance test results of the fifth generation cryogenic capillary pumped loop (CCPL-5). This device will fly on STS-95 in October 1998 as part of the CRYOTSU Flight Experiment. This flight represents the first in-space demonstration of a CCPL, a miniaturized two-phase fluid circulator for thermally linking cryogenic cooling sources to remote cryogenic components. CCPL-5 utilizes N2 as the working fluid and has a practical operating range of 75-110 K. Test results indicate that CCPL-5, which weighs about 200 grams, can transport over 10 W of cooling a distance of 0.25 m (or more) with less than a 5 K temperature drop.

Bugby, David C.↗

Design and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment

This paper details the flight configuration and pre-flight performance test results of the fifth generation cryogenic capillary pumped loop (CCPL-5). This device will fly on STS-95 in October 1998 as part of the CRYOTSU Flight Experiment. This flight represents the first in-space demonstration of a CCPL; a miniaturized two-phase fluid circulator for thermally linking cryogenic components. CCPL-5 utilizes N2 as the working fluid and has a practical operating range of 75-110 K. Test results indicate that CCPL-5, which weighs about 200 grams, can transport over 10 W of cooling a distance of 0.25 m (or more) with less than a 5 K temperature drop.

Bugby, David C.↗

Pumped two-phase heat transfer loop

A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes a plurality of independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.

Edelstein, Fred↗