34 records · Page 2

A New Frontier for Cardiac Monitoring

CardioDynamics International Corporation (CDIC) has created the BioZ(TM) System through a Small Business Innovation Research (SBIR) award from Johnson Space Center, providing patients and physicians with a cost-effective and highly accurate monitoring system.The BioZ non-invasive heart monitor is based on a technology known as Impedance Cardiography (ICG). BioZ provides the physician with vital information about the heart's ability to deliver blood to the body, the force one's heart exerts with each beat, and the amount of fluid in the chest. Specially designed bioimpedance sensors placed on the neck and chest monitor 12 different parameters, including cardiac output, contractility, systemic vascular resistance, and thoracic fluid content. These sensors monitor the electrical conductivity of the body-information that is converted into blood flow data and is displayed in real time on a monitoring screen. BioZ.com(TM) and BioZ.pc(TM) are two additional products that incorporate the same sensors present in the original BioZ system. The "com" in BioZ.com stands for cardiac output monitor. This fully integrated system is essentially a smaller version of the BioZ, combining the same abilities with a compact, lightweight design, while providing greater portability.

Source record

Acute hemodynamic responses to weightlessness in humans

As NASA designs space flights requiring prolonged periods of weightlessness for a broader segment of the population, it will be important to know the acute and sustained effects of weightlessness on the cardiovascular system since this information will contribute to understanding of the clinical pharmacology of drugs administered in space. Due to operational constraints on space flights, earliest effects of weightlessness have not been documented. We examined hemodynamic responses of humans to transitions from acceleration to weightlessness during parabolic flight on NASA's KC-135 aircraft. Impedance cardiography data were collected over four sets of 8-10 parabolas, with a brief rest period between sets. Each parabola included a period of 1.8 Gz, then approximately 20 seconds of weightlessness, and finally a period of 1.6 Gz; the cycle repeated almost immediately for the remainder of the set. Subjects were semi-supine (Shuttle launch posture) for the first set, then randomly supine, sitting and standing for each subsequent set. Transition to weightlessness while standing produced decreased heart rate, increased thoracic fluid content, and increased stroke index. Surprisingly, the onset of weightlessness in the semi-supine posture produced little evidence of a headward fluid shift. Heart rate, stroke index, and cardiac index are virtually unchanged after 20 seconds of weightlessness, and thoracic fluid content is slightly decreased. Semi-supine responses run counter to Shuttle crewmember reports of noticeable fluid shift after minutes to hours in orbit. Apparently, the headward fluid shift commences in the semi-supine posture before launch. is augmented by launch acceleration, but briefly interrupted immediately in orbit, then resumes and is completed over the next hours.

short duration

Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor inputs (e.g., somatosensory) or other circulatory reflex mechanisms.

Wood, Scott J.

User Interactive Software for Analysis of Human Physiological Data

Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

Cowings, Patricia S.

Comparison of Two Methods for Noninvasive Determination of Stroke Volume During Orthostatic Challenge

Background: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.

Doerr, Donald F.

A Proposed Study Examining Individual Differences in Temporal Profiles of Cardiovascular Responses to Head Down Tilt During Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. Hypovolemia, reduced plasma volume, is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore lost plasma volume by giving crew salt tablets and water prior to re-entry. The main purpose of the proposed study is to define the temporal profile of cardiac responses to simulated 0-G conditions before and following a fluid loading countermeasure. 8 men and 8 women will be tested during 4 hour exposures at 6o head down tilt (HDT). Each subject will be given two exposures to HDT on separate days, one with and one without fluid loading (one liter of 0.9% saline solution). Stand tests (orthostatic stress) will be done before and after each HDT. Cardiac measures will be obtained with both impedance cardiography and echo ultrasound

Cowings, Patricia

Examining Individual Differences in Temporal Profiles of Cardiovascular Responses to the Head Down Tilt during Fluid Loading

Upon returning to Earth after an extended exposure to micro-gravity in space many astronauts have experienced symptoms of light headedness and fainting associated with post-flight orthostatic intolerance (low blood pressure). The main reason for this condition is the reduced fluid volume in the body while in space. A preventative treatment was proposed to prevent this condition by fluid loading to restore lost plasma volume by giving crew members salt tablets and water prior to re-entry. In order to simulate micro-gravity effects on earth test subjects are placed in a supine position with their head below the level of their heart (6 head down tilt-HDT). The purpose of the present study is to define individual differences in the time course of cardiac stroke volume responses to HDT (6 hours) and the effectiveness of fluid loading for mitigating orthostatic intolerance when standing . Echocardiography and impedance cardiography data will be collected on 8 men and 8 women to examine heart function to HDT. A second objective is to determine if the effects of fluid loading vary due to individual differences (e.g., age, gender, height, weight, physical fitness, etc.).

orthostatic intolerance

Dynamocardiography

Analysis of cardiac activity by center of gravity variations in human thorax - dynamocardiograph

CARDIOGRAPHY

Cardiovascular effects of a fractional -Gz force during a relatively prolonged exposure

Artificial hypogravity was created by having subjects remain in a supine position while undergoing rotation in an artificial gravity simulator. Various cardiovascular variables, such as heart rate, cardiac output, thoracic electric impedance, and blood pressure were measured. Results indicated that the hypogravity force produced a headward fluid shift, as seen by a decrease in thoracic impedance, which triggers regulatory neuroendocrine mechanisms. These findings are presented and discussed.

Non-NASA Center

Autoregulation of cerebral blood flow in orthostatic hypotension

BACKGROUND AND PURPOSE: We sought to evaluate cerebral autoregulation in patients with orthostatic hypotension (OH). METHODS: We studied 21 patients (aged 52 to 78 years) with neurogenic OH during 80 degrees head-up tilt. Blood flow velocities (BFV) from the middle cerebral artery were continuously monitored with transcranial Doppler sonography, as were heart rate, blood pressure (BP), cardiac output, stroke volume, CO2, total peripheral resistance, and cerebrovascular resistance. RESULTS: All OH patients had lower BP (P<.0001), BFV_diastolic (P<.05), CVR (P<.007), and TPR (P<.02) during head-up tilt than control subjects. In control subjects, no correlations between BFV and BP were found during head-up tilt, suggesting normal autoregulation. OH patients could be separated into those with normal or expanded autoregulation (OH_NA; n=16) and those with autoregulatory failure (OH_AF; n=5). The OH_NA group showed either no correlation between BFV and BP (n=8) or had a positive BFV/BP correlation (R2>.75) but with a flat slope. An expansion of the "autoregulated" range was seen in some patients. The OH_AF group was characterized by a profound fall in BFV in response to a small reduction in BP (mean deltaBP <40 mm Hg; R2>.75). CONCLUSIONS: The most common patterns of cerebral response to OH are autoregulatory failure with a flat flow-pressure relationship or intact autoregulation with an expanded autoregulated range. The least common pattern is autoregulatory failure with a steep flow-pressure relationship. Patients with patterns 1 and 2 have an enhanced capacity to cope with OH, while those with pattern 3 have reduced capacity.

Non-NASA Center