Search NASA⌕ Search

SEARCH · Search NASA

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluating Wind Direction Consensus Methods: A Case Study

Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. To enable cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving these cooperative wind farms is to develop algorithms that provide necessary information to ensure reliable and efficient operation of turbines in a wind plant using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. This presentation demonstrates a framework for implementing a cooperative wind. Farm that incorporates information from local sensors in real time to better align turbines in a wind farm. Oftentimes, measurements made at an individual turbine are noisy and unreliable. By incorporating measurements from multiple nearby turbines, a more reliable estimate of the wind direction can be obtained at an individual turbine. Results indicate that this estimate of the wind direction can be used to improve the turbine's knowledge of the wind direction and could decrease dynamic yaw misalignment, decrease the amount of time a turbines spends yawing due to a more reliable input to the yaw controller, and increase resiliency to faulty wind-vane measurements. The concept was evaluated on data provided by WindESCo and was evaluated across several other averaging techniques to demonstrate the resiliency of the proposed consensus method.

17 WIND ENERGY↗

Structural and elastic anisotropy of crystals at high pressures and temperatures from quantum mechanical methods: The case of Mg{sub 2}SiO{sub 4} forsterite

We report accurate ab initio theoretical predictions of the elastic, seismic, and structural anisotropy of the orthorhombic Mg{sub 2}SiO{sub 4} forsterite crystal at high pressures (up to 20 GPa) and temperatures (up to its melting point, 2163 K), which constitute earth’s upper mantle conditions. Single-crystal elastic stiffness constants are evaluated up to 20 GPa and their first- and second-order pressure derivatives reported. Christoffel’s equation is solved at several pressures: directional seismic wave velocities and related properties (azimuthal and polarization seismic anisotropies) discussed. Thermal structural and average elastic properties, as computed within the quasi-harmonic approximation of the lattice potential, are predicted at high pressures and temperatures: directional thermal expansion coefficients, first- and second-order pressure derivatives of the isothermal bulk modulus, and P-V-T equation-of-state. The effect on computed properties of five different functionals, belonging to three different classes of approximations, of the density functional theory is explicitly investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extension of Case's method to the two-region critical cylinder and its application as an analytic standard

The normal mode expansion technique is applied to the transformed monoenergetic integral transport equation to develop a solution for the rotationally invariant and axially infinite, critical, two-region cylinder with a finite outer reflector boundary. Isotropic scattering and identical neutron mean free paths in the core and reflector regions are assumed. The solution in terms of singular integral equations is obtained by applying a completeness theorem found for the singular eigenfunctions. Numerical results for a variety of core and reflector multiplying properties and reflector thickness are presented and compared with the results of other method. An example of this type of application is given in a study of approximations inherent in the neutronic design analysis of a small, fast-neutron-spectrum reactor concept proposed as a space power source.

Westfall, R. M.↗

SU-E-T-309: Tangential Modulated Arc Therapy: A Novel Technique for the Treatment of Superficial Disease

Purpose: We propose a new type of treatment that employs a modulated and sliding tangential photon field to provide superior coverage of superficial targets when compared to other commonly employed methods while drastically reducing dose to the underlying sensitive structures often present in these cases. Methods: Modulated treatment plans were formulated for a set of three representative cases. The first was a revised treatment of a scalp sarcoma, while the second was a treatment of a right posterior chest wall sarcoma. For these cases, asymmetric jaw placement, angular limitations, and central isocenter placements were used to force the optimization algorithm into finding solutions with beamlines that were not perpendicular to the body surface. The final case targeted the chest wall of a breast cancer patient, in which standard treatments were compared to the use of modulated fields with multiple isocenters along the chest wall. Results: When compared with unrestricted modulated arcs, the tangential arc scalp treatment reduced the max and mean doses delivered to the brain by 33Gy (from 55 to 22Gy) and 6Gy (from 14Gy to 8Gy), respectively. In the right posterior chest wall case, the V10 in the ipsilateral lung was kept below 5% while retaining a Rx dose (45Gy) target coverage of over 97%. For the breast case, the modulated plan achieved reductions in high dose to the ipsilateral lung and heart by a factor of 2–3 when compared to classic laterally opposed tangents and reduced the V5 by 40% when compared to standard modulated arcs. Conclusion: Tangential modulated arc therapy has outperformed the conventional modalities of treatment for superficial lesions used in our clinic. We hope that with the advent of digitally controlled linear accelerators, we can uncover further benefits of this new technique and extend its applicability to a wider section of the patient population.

60 APPLIED LIFE SCIENCES↗

Influence of nuclear interactions in body tissues on tumor dose in carbon-ion radiotherapy

Purpose: In carbon-ion radiotherapy treatment planning, the planar integrated dose (PID) measured in water is applied to the patient dose calculation with density scaling using the stopping power ratio. Since body tissues are chemically different from water, this dose calculation can be subject to errors, particularly due to differences in inelastic nuclear interactions. In recent studies, the authors proposed and validated a PID correction method for these errors. In the present study, the authors used this correction method to assess the influence of these nuclear interactions in body tissues on tumor dose in various clinical cases. Methods: Using 10–20 cases each of prostate, head and neck (HN), bone and soft tissue (BS), lung, liver, pancreas, and uterine neoplasms, the authors first used treatment plans for carbon-ion radiotherapy without nuclear interaction correction to derive uncorrected dose distributions. The authors then compared these distributions with recalculated distributions using the nuclear interaction correction (corrected dose distributions). Results: Median (25%/75% quartiles) differences between the target mean uncorrected doses and corrected doses were 0.2% (0.1%/0.2%), 0.0% (0.0%/0.0%), −0.3% (−0.4%/−0.2%), −0.1% (−0.2%/−0.1%), −0.1% (−0.2%/0.0%), −0.4% (−0.5%/−0.1%), and −0.3% (−0.4%/0.0%) for the prostate, HN, BS, lung, liver, pancreas, and uterine cases, respectively. The largest difference of −1.6% in target mean and −2.5% at maximum were observed in a uterine case. Conclusions: For most clinical cases, dose calculation errors due to the water nonequivalence of the tissues in nuclear interactions would be marginal compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response. In some extreme cases, however, these errors can be substantial. Accordingly, this correction method should be routinely applied to treatment planning in clinical practice.

60 APPLIED LIFE SCIENCES↗

A New Way to Measure Cirrus Ice Water Content by Using Ice Raman Scatter with Raman Lidar

High and cold cirrus clouds mainly contain irregular ice crystals, such as, columns, hexagonal plates, bullet rosettes, and dendrites, and have different impacts on the climate system than low-level clouds, such as stratus, stratocumulus, and cumulus. The radiative effects of cirrus clouds on the current and future climate depend strongly on cirrus cloud microphysical properties including ice water content (IWC) and ice crystal sizes, which are mostly an unknown aspect of cinus clouds. Because of the natural complexity of cirrus clouds and their high locations, it is a challenging task to get them accurately by both remote sensing and in situ sampling. This study presents a new method to remotely sense cirrus microphysical properties by using ice Raman scatter with a Raman lidar. The intensity of Raman scattering is fundamentally proportional to the number of molecules involved. Therefore, ice Raman scattering signal provides a more direct way to measure IWC than other remote sensing methods. Case studies show that this method has the potential to provide essential information of cirrus microphysical properties to study cloud physical processes in cirrus clouds.

Wang, Zhien↗

SU-C-202-01: Incorporating Time-Dependent Hypoxia in IMRT Planning

Purpose: To incorporate uncertainties in oxygenation of tumor cells into radiation therapy planning via robust optimization. The model is demonstrated using a clinical prostate cancer case. Methods: The tumor oxygenation levels are determined based on pre- and mid-treatment PET scans. To account for oxygenation changes, we use a radio-sensitivity factor for the effective dose necessary to treat hypoxic cells. Due to the unpredictable nature of re-oxygenation of hypoxic cells, the radio-sensitivity factor and its change is modeled to reside in a time-dependent uncertainty set. This uncertainty can adapt to both pre- and mid-treatment scans, resulting in a two-stage robust treatment planning model. We develop a robust counterpart reformulation that transforms the original NP-hard problem into a linear program consisting of finitely many linear constraints, which can be solved efficiently. Results: The robust plan is compared to both the corresponding fractionated plan which ignores hypoxia, and to the commonly practiced dose-escalated plan that uniformly increases dose based on initial oxygen concentrations. For PTV, the robust plan improves D{sub 50}, D{sub 95}, and EUD by 4% on average compared to fractionated, and by 11% compared to the optimal escalated plan. Moreover, the robust plan spared organs at risk similar to the fractionated plan, while the escalated plan led to over 170% increase of Bladder D{sub 30}. Conclusion: The proposed robust adaptive model can improve tumor coverage by increasing dose to hypoxic tumor voxels that is overlooked by common fractionated treatments. In addition, the robust model anticipates the re-oxygenation process, thus reducing the excess dose at later fractions in comparison to uniform dose-escalation methods.

60 APPLIED LIFE SCIENCES↗

New approach to creation of geometrical module for nuclear reactor neutron transport computer simulation analysis

This paper presents the new approach to creation of geometrical module for nuclear reactor neutron transport computer simulation analysis so called the differential cross method. It is elaborated for detecting boards between physical zones. It is proposed to use GMSH open source mesh editor extended by some features: a special option and a special kind of mesh (cubic background mesh).This method is aimed into Monte Carlo Method as well as for deterministic neutron transport methods. Special attention is attended for reactor core composed of a set of material zones with complicate geometrical boundaries. The idea of this approach is described. In general case method works for 3-D space. Algorithm of creation of the geometrical module is given. 2-D neutron transport benchmark-test for RBMK reactor cluster cell is described. It demonstrates the ability of this approach to provide flexible definition of geometrical meshing with preservation of curved surface or any level of heterogeneity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-770: Tumor Control in Ion Beam Radiotherapy with Different Ions in Presence of Hypoxia

Purpose: The reduced concentration of oxygen in cells (hypoxia) results in a lower cell death rate after irradiation that can lead to treatment failure. The effect can be expressed by the oxygen enhancement ratio (OER). So far, only few attempts to include OER in treatment planning for ion beam therapy were made, which are based on the dose averaged LET estimates and do not distinguish among ion species and fractionation schemes. To overcome these limitations, we implemented a new OER model and used it to estimate tumor control in clinical cases. Methods: The model, based on the microdosimetric kinetic model, was benchmarked with in-vitro data from different ions irradiation. It was included in the simulation of treatments of a set of clinical cases (glioblastoma) using p, Li, He, C and O ion beams. Tumor Control Probability (TCP) was estimated as a function of oxygen partial pressure, dose per fraction and primary ion type. Results: The modelized OER was found to be strongly dependent on both LET and ion type, and showed a decreasing OER for increasing dose per fraction with a slope that depends on the LET and ion type, in good agreement with the experimental data. In the clinical cases studied, an increase in TCP by increasing ion charge and dose per fraction (more than 30% variation from p to O for moderate hypoxia) was found. Higher OER decrease rates as function of dose per fraction were found for lighter ions (up to 20% varying from 2 to 8 Gy(RBE)). Conclusions: A novel modeling of the OER that explicitly includes the dependence on ion type and dose per fraction was implemented. The model was exploited to evaluate the impact of hypoxia in ion beam radiotherapy, facilitating the identification of the treatment condition optimality, including fractionation scheme and ion type.

60 APPLIED LIFE SCIENCES↗

Results of ISO/TS 6336-22 Evaluating Full Contact Zone

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears - Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

ENGINEERING,WIND ENERGY↗

Results of ISO/TS 6336-22 Evaluating Full Contact Zone: Preprint

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears — Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

gearbox↗

Results of ISO/TS 6336-22 Evaluating Full Contact Zone

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears - Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

gearbox↗

SU-E-T-139: Dynamic Conformal Arcs Vs. VMAT for Stereotactic Lung Target Treatment Planning

Purpose: To investigate if Dynamic Conformal Arcs (DCA) can be used to achieve similar target coverage and conformality as that of using VMAT for Stereotactic Body Radiation Therapy (SBRT) for Lung cases. Methods: We retrospectively re-planned 11 patients that were treated with SBRT for lung tumors using only a single conformal arc, broken into three or four arc segments and weighted differentially in order to achieve the dosimetric constraints as outlined in RTOG 0915 protocol. These re-plans of using DCA were compared with those of using VMAT in terms of the Planning Tumor Volume (PTV) coverage goals, Maximum Dose 2 cm away (D {sub 2}cm), High Dose Spillage, Intermediate Dose Spillage, Lung volume getting 5 Gy (V{sub 5}), and number of monitor units (MU). Results: Of the 11 cases, only three DCA plans failed the D{sub 2}cm parameter, and one VMAT plan failed. None of the 11 patients failed the High Dose Spillage in either technique. For Intermediate Dose Spillage, one DCA plan failed and none failed for VMAT plans. The average V{sub 5} for DCA was 10.5 percent, with VMAT reporting 11.7 percent. The average number of MU for DCA and VMAT were 2605 and 3451, respectively. Conclusion: DCA is able to achieve very similar treatment planning goals as that of using VMAT in treating SBRT Lung tumors in most cases with simplicity. In addition, the DCA technique produces an acceptable plan with lower V{sub 5} in less MU when dose to OAR concerns are at minimum. However, DCA has shown its limitations when the target is close to multiple OAR.

60 APPLIED LIFE SCIENCES↗