Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHEMILUMINESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Low-Temperature Chemiluminescence From cis-1,4-Polybutadiene, 1,2-Polybutadiene, and trans-Polypentenamer at Temperatures Near Ambient

The chemiluminescence emission at 25-60 C was measured from films of cis-1,4-polybutadiene, 1,2-polybutadiene, and trans-polypentenamer. The polymers were autoxidized previously in air 100 C, or allowed to react with singlet molecular oxygen in solution, and then cast into films. Values of beta(or k(sub d,((1)O2 yields (3)03)/k(sub r)((1)O2 + polymer yields products)) were determined in benzene for cis-1,4-polybutadiene and cis-1,4-polyisoprene, and for model compounds cis-3-hexene and cis-3-methyl-3-hexene by independent methods. The chemiluminescence emission from irradiated films of the polymers containing a dye sensitizer showed a complicated time dependence, and the results depended on the length of irradiation.

Nathan, Richard A.↗

Aqueous chemiluminescent systems

This invention relates to novel water-soluble esters of oxalic acid, and to compositions that are useful for generating chemiluminescent emission by reacting said esters of oxalic acid with hydrogen peroxide in the presence of water and a fluorescent compound, and to a process for generating chemiluminescent emission by using said compositions.

Mohan, Arthur Gaudens↗

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion↗

Highly Stable Fe/Co-TPY-MIL-88(NH 2 ) Metal–Organic Framework (MOF) in Enzymatic Cascade Reactions for Chemiluminescence-Based Detection of Extracellular Vesicles

Metal-Organic Frameworks (MOFs) can deliver many advantages when acting as enzyme mimics to assist with signal amplification in molecular detection: they have abundant active catalytic sites per unit volume of the material; their structures and elemental compositions are highly tunable, and their high specific surface area and porous property can assist with target separation and enrichment. In the present work, we have demonstrated that, by adding the pore partition agent, 2,4,6-tris(4-pyridyl)pyridine (TPY) during synthesis of the bimetallic Fe/Co-MIL-88(NH 2 ) MOF to block the open metal sites, a highly porous MOF of Fe/Co-TPY-MIL-88(NH 2 ) can be produced. This material also exhibits high stability in basic solutions and biofluids and possesses high peroxidase-mimicking activity, which can be utilized to produce long-lasting chemiluminescence (CL) from luminol and H 2 O 2 . Moreover, acting as the peroxidase-mimic, the Fe/Co-TPY-MIL-88(NH 2 ) MOF can form the enzymatic cascade with glucose oxidase (GOx) for biomarker detection. Further, when applied to detect extracellular vesicles (EVs), the MOF material and GOx are brought to the proximity on the EVs through two surface proteins, which triggers the enzyme cascade to produce high CL from glucose and luminol. EVs within the concentration range of 5 × 10 5 - 4 ×10 7 particles/mL can be detected, and the method can be used to analyze EV contents in human serum without sample preparation and EV purification. Overall, our work demonstrates that the high versatility and tunability of the MOF structures could bring in significant benefits to biosensing and enable ultrasensitive detection of biomarkers with judicious material designs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is a promising hydrogen carrier due to its favorable storage and transport characteristics. However, its direct use in combustion systems is limited by low flammability and potential for high nitrogen oxide emissions. To better understand ammonia combustion, researchers conducted experiments using a flat flame burner and measured species profiles using tunable-diode-laser-absorption-spectroscopy and chemiluminescence imaging. They tested three flame conditions with different ammonia-hydrogen blends and oxygen levels. The results were compared to simulations using various kinetic mechanisms, including one that accounts for excited species chemistry. The goal is to provide direct information about species profiles in a simple system, isolating chemical kinetics from fluid dynamic effects, which can inform the development of more efficient and low-emission combustion systems using ammonia.

ammonia combustion↗

A Size-Selectively Biomolecule-Immobilized Nanoprobe-Based Chemiluminescent Lateral Flow Immunoassay for Detection of Avian-Origin Viruses

Here, a signal-amplifiable nanoprobe-based chemiluminescent lateral flow immunoassay (CL-LFA) was developed to detect avian influenza viruses (AIV) and other contagious and fatal viral avian-origin diseases worldwide. Signal-amplifiable nanoprobes are capable of size-selective immobilization of antibodies (binding receptors) and enzymes (signal transducers) on sensitive paper-based sensor platforms. Particle structure designs and conjugation pathways conducive for antigen accessibility to maximum amounts of immobilized enzymes and antibodies have advanced. The detection limit of the CL-LFA using the signal-amplifiable nanoprobe for the nucleoprotein of the H3N2 virus was 5 pM. Sensitivity tests for low pathogenicity avian influenza H9N2, H1N1, and high pathogenicity avian influenza H5N9 viruses were conducted, and the detection limits of CL-LFA were found to be 10 3.5 50% egg infective dose (EID 50 )/mL, 10 2.5 EID 50 /mL, and 10 4 EID 50 /mL, respectively, which is 20 to 100 times lower than that of a commercial AIV rapid test kit. Moreover, CL-LFA demonstrated high sensitivity and specificity against 37 clinical samples. The signal-amplifiable probe designed in this study is a potential diagnostic probe with ultrahigh sensitivity for applications in the field of clinical diagnosis, which requires sensitive antigen detection as evidenced by enhanced signaling capacity and sensitivity of the LFAs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consideration of Nonideal Detonation Regimes Influenced by Wave Modes in a Water-Cooled Rotating Detonation Engine Using OH* Chemiluminescence

Although inherently unstable, existing research in rotating detonation combustion supports its application in notionally steady processes resulting in greater availability compared to conventional, constant pressure combustion. Further improvements rely on a more in-depth understanding of system losses and identifying conditions which optimize device performance. Within this study, the presence and proportion of ideal and nonideal combustion regimes are compared across a variety of process conditions and wave modes. Here, large-scale data analysis seeks to summarize proportional heat release associated with commensal, parasitic, and detonative combustion averaged across individual traces of OH* chemiluminescent data acquired at the detonation plane. Means of regime partitioning based on the anatomy of the time-resolved OH* signal are proposed to ensure consistent analysis throughout the current and future studies concerning combustion regimes. Of particular interest is the possible influence of wave on the nonideal combustion in relative proportion to the desired detonation. Results showed improved percent detonation with increasing significance for the following trends: decreasing equivalence ratio, increasing wave count, decreasing wave velocity, and increasing detonation time. Increased wave number, brought on by decreased equivalence ratios and wave velocities, is thought to decrease fill region surface area, and therefore, decrease nonideal contact burning. Additional analysis is performed to consider possible trend variation due to the presence of stable galloping waves, which were found to have minimal influence on relative percent detonation values. The outcome of this study suggests operational states, which correspond to increased wave quantities for increased proportions of reactants consumed by the targeted detonative combustion regime.

42 ENGINEERING↗

Electrogenerated Chemiluminescence of Near-Infrared-Emitting CdSe@CdSe Nanorods in Aqueous Solution

Electrogenerated chemiluminescence (ECL) was observed from TOPO-capped CdSe@CdSe nanorods (NRs) depositing on a metal electrode in phosphate buffer solution (PBS). Two ECL peaks at -1.05 and -1.33 V in pH 9.2, 0.1 M PBS were found under cyclic voltammetric conditions. Cyclic voltammetry of this solution displayed no distinctive features, on the other hand, light emission was observed during cyclic potential scans. Additionally, the photoluminescence (PL) spectrum showed an emission maximum at 692 nm. The spectrum of ECL possesses one peak which coincides very well with the PL spectrum of the nanorods film. The mechanism for ECL peaks was proposed. Electron transfer reactions between charged nanorods and molecular redox-active coreactants such as dissolved oxygen and H2O2 or between positively and negatively charged nanorods occurred that led to electron and hole annihilation, producing light.

36 MATERIALS SCIENCE↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is viewed as a viable hydrogen carrier due to favorable storage and transport characteristics. While it can be re-converted to hydrogen at point-of-use via thermal catalytic cracking, direct utilization in combustion systems can result in reduced costs and improved efficiency. A major barrier to this approach is the low flammability and potential for high nitrogen oxide emissions, driven by fuel-bound nitrogen and complex kinetic pathways. While a number of kinetic mechanisms currently exist for simulating ammonia combustion, a major need continues to be direct information about species profiles in easy-to-model systems capable of isolating chemical kinetics from multi-dimensional fluid dynamic effects. This paper reports on recent species measurements made in a flat flame burner using a combined tunable-diode-laser-absorption-spectroscopy (TDLAS) and chemiluminescence imaging approach. Three flame conditions were included representative of NH3/H2 blends, partially cracked NH3 (inc. N2), and 100% NH3 with enhanced air (30% oxygen). Two NIR distributed feedback (DFB) laser diodes were used to determine H2O concentration and temperature (via ratio thermometry) at various radial and axial positions, after which an inverse Abel transform was used to infer centerline values. Companion images were collected using a Princeton Instrument PI-MAX intensified camera equipped with a 105mm UV lens and multiple filter sets targeting OH*, NH*, and NH2* emission. Results were compared to companion Cantera burner-stabilized flame simulations using various kinetic mechanisms. A recent mechanism including excited species chemistry was also included, to investigate whether excited and ground state profiles exhibit significant differences.

ammonia combustion↗