Search NASA⌕ Search

SEARCH · Search NASA

Results for “CIRCULATORY SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ultrasound Techniques for Space Applications

Ultrasound has proven to be a safe non-invasive technique for imaging organs and measuring cardiovascular function. It has unique advantages for application to problems with man in space including evaluation of cardiovascular function both in serial studies and during critical operations. In addition, specialized instrumentation may be capable of detecting the onset of decompression sickness during EVA activities. A spatial location and three-dimensional reconstruction system is being developed to improve the accuracy and reproducibility for serial comparative ultrasound studies of cardiovascular function. The three-dimensional method permits the acquisition of ultrasonic images from many views that can be recombined into a single reconstruction of the heart or vasculature. In addition to conventional imaging and monitoring systems, it is sometimes necessary or desirable to develop instrumentation for special purposes. One example of this type of development is the design of a pulsed-Doppler system to monitor cerebral blood flow during critical operations such as re-entry. A second example is the design of a swept-frequency ultrasound system for the detection of bubbles in the circulatory system and/or soft tissues as an early indication of the onset of decompression sickness during EVA activities. This system exploits the resonant properties of bubbles and can detect both fundamental and second harmonic emissions from the insonified region.

Rooney, James A.↗

Physiological system integrations with emphasis on the respiratory-cardiovascular system

The integration of two types of physiological system simulations is presented. The long term model is a circulatory system model which simulates long term blood flow variations and compartmental fluid shifts. The short term models simulate transient phenomena of the respiratory, thermoregulatory, and pulsatile cardiovascular systems as they respond to stimuli such as LBNP, exercise, and environmental gaseous variations. An overview of the interfacing approach is described. Descriptions of the variable interface for long term to short term and between the three short term models are given.

Gallagher, R. R.↗

Development of a flow feedback pulse duplicator system with rhesus monkey arterial input impedance characteristics

An in vitro pulsatile pump flow system that is capable of producing physiologic pressures and flows in a mock circulatory system tuned to reproduce the first nine harmonics of the input impedance of a rhesus monkey was developed and tested. The system was created as a research tool for evaluating cardiovascular function and for the design, testing, and evaluation of electrical-mechanical cardiovascular models and chronically implanted sensors. The system possesses a computerized user interface for controlling a linear displacement pulsatile pump in a controlled flow loop format to emulate in vivo cardiovascular characteristics. Evaluation of the pump system consisted of comparing its aortic pressure and flow profiles with in vivo rhesus hemodynamic waveforms in the time and frequency domains. Comparison of aortic pressure and flow data between the pump system and in vivo data showed good agreement in the time and frequency domains, however, the pump system produced a larger pulse pressure. The pump system can be used for comparing cardiovascular parameters with predicted cardiovascular model values and for evaluating such items as vascular grafts, heart valves, biomaterials, and sensors. This article describes the development and evaluation of this feedback controlled cardiovascular dynamics simulation modeling system.

Non-NASA Center↗

Supervisory Algorithm for Autonomous Hemodynamic Management Systems

Future military conflicts will require new solutions to manage combat casualties. The use of automated medical systems can potentially address this need by streamlining and augmenting the delivery of medical care in both emergency and combat trauma environments. However, in many situations, these systems may need to operate in conjunction with other autonomous and semi-autonomous devices. Management of complex patients may require multiple automated systems operating simultaneously and potentially competing with each other. Supervisory controllers capable of harmonizing multiple closed-loop systems are thus essential before multiple automated medical systems can be deployed in managing complex medical situations. The objective for this study was to develop a Supervisory Algorithm for Casualty Management (SACM) that manages decisions and interplay between two automated systems designed for management of hemorrhage control and resuscitation: an automatic extremity tourniquet system and an adaptive resuscitation controller. SACM monitors the required physiological inputs for both systems and synchronizes each respective system as needed. We present a series of trauma experiments carried out in a physiologically relevant benchtop circulatory system in which SACM must recognize extremity or internal hemorrhage, activate the corresponding algorithm to apply a tourniquet, and then resuscitate back to the target pressure setpoint. SACM continues monitoring after the initial stabilization so that additional medical changes can be quickly identified and addressed, essential to extending automation algorithms past initial trauma resuscitation into extended monitoring. Overall, SACM is an important step in transitioning automated medical systems into emergency and combat trauma situations. Future work will address further interplay between these systems and integrate additional medical systems.

42 ENGINEERING↗

Atmospheric fungal nanoparticle bursts

Aerosol nanoparticles play an important role in the climate system by affecting cloud formation and properties, as well as in human health because of their deep reach into lungs and the circulatory system. Determining nanoparticle sources and composition is a major challenge in assessing their impacts in these areas. The sudden appearance of large numbers of atmospheric nanoparticles is commonly attributed to secondary formation from gas-phase precursors, but in many cases, the evidence for this is equivocal. We report the detection of a mode of fungal fragments with a mobility diameter of roughly 30 nm released in episodic bursts in ambient air over an agricultural area in northern Oklahoma. These events reached concentrations orders of magnitude higher than other reports of biological particles and show similarities to unclarified events reported previously in the Amazon. These particles potentially represent a large source of both cloud-forming ice nuclei and respirable allergens in a variety of ecosystems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circulation-Enhancing Device Improves CPR

Advanced Circulatory Systems, Inc. and NASA's Kennedy Space Center collaborated for five years on impedance threshold device technology. The resulting technology is encapsulated in a device called the ResQPOD Circulatory Enhancer, which improves the standard of care provided to patients with a variety of clinical conditions due to low blood flow. ResQPOD generates negative intrathoracic pressure during respiration to increase blood flow to the body's vital organs. It is unique in that it non-invasively enhances the body's biophysical performance without depending on pharmaceutical or other outside agents. ResQPOD uses the relationship of the heart, brain, lungs and chest cavity in a manner similar to a bellows to increase venous blood return to the heart. Multiple studies have shown a significant improvement in cardiac output and blood flow to the brain with the use of the impedance threshold device, as well as the device's ability to prevent shock secondary to blood loss. ResQPOD has been added to the set of medical equipment that is available for returning astronaut crews, and commercial applications have fallen into two categories: Non-spontaneously breathing patients who can benefit from enhanced circulation, and spontaneously breathing patients who suffer from transient hypotension or low blood pressure.

Source record↗

Effect of sudden solar wind dynamic pressure changes at subauroral latitudes - Change in magnetic field

The observations obtained during the International Magnetospheric Study (IMS) from the magnetometers of the IGS network extending from Cambridge, England, to Tromso, Norway, are used to study the response of subauroral current systems to sudden changes in solar wind dynamic pressure. Observations show that the response is very strong at subauroral latitudes. The preliminary response in the H component is a brief, small increase in the dayside morning sector and a decrease in the aftenoon and night sectors. The main response in the horizontal field (the H and D components) is toward the pole except in the dayside morning sector. The inferred ionospheric current is mainly a circulatory system flowing counterclockwise when viewed from the north pole everywhere at subauroral latitudes except the dayside morning sector.

Le, G.↗

Causes and consequences of reduced blood volume in space flight - A multi-discipline modeling study

A group of mathematical models of various physiological systems have been developed and applied to studying problems associated with adaptation to weightlessness. One biomedical issue which could be addressed by at least three of these models from varying perspectives was the reduction in blood volume that universally occurs in astronauts. Accordingly, models of fluid-electrolyte, erythropoiesis, and cardiovascular regulation were employed to study the causes and consequences of blood volume loss during space flight. This analysis confirms the notion that alterations of blood volume are central to an understanding of adaptation to prolonged space flight. More importantly, the modeling studies resulted in specific hypotheses accounting for plasma volume and red cell mass losses and testable predictions concerning the behavior of the circulatory system.

Leonard, J. I.↗

Space Radiation Cancer, Circulatory Disease and CNS Risks for Near Earth Asteroid and Mars Missions: Uncertainty Estimates for Never-Smokers

The uncertainties in estimating the health risks from galactic cosmic rays (GCR) and solar particle events (SPE) are a major limitation to the length of space missions and the evaluation of potential risk mitigation approaches. NASA limits astronaut exposures to a 3% risk of exposure induced cancer death (REID), and protects against uncertainties in risks projections using an assessment of 95% confidence intervals after propagating the error from all model factors (environment and organ exposure, risk coefficients, dose-rate modifiers, and quality factors). Because there are potentially significant late mortality risks from diseases of the circulatory system and central nervous system (CNS) which are less well defined than cancer risks, the cancer REID limit is not necessarily conservative. In this report, we discuss estimates of lifetime risks from space radiation and new estimates of model uncertainties are described. The key updates to the NASA risk projection model are: 1) Revised values for low LET risk coefficients for tissue specific cancer incidence, with incidence rates transported to an average U.S. population to estimate the probability of Risk of Exposure Induced Cancer (REIC) and REID. 2) An analysis of smoking attributable cancer risks for never-smokers that shows significantly reduced lung cancer risk as well as overall cancer risks from radiation compared to risk estimated for the average U.S. population. 3) Derivation of track structure based quality functions depends on particle fluence, charge number, Z and kinetic energy, E. 4) The assignment of a smaller maximum in quality function for leukemia than for solid cancers. 5) The use of the ICRP tissue weights is shown to over-estimate cancer risks from SPEs by a factor of 2 or more. Summing cancer risks for each tissue is recommended as a more accurate approach to estimate SPE cancer risks. 6) Additional considerations on circulatory and CNS disease risks. Our analysis shows that an individual s history of smoking exposure has a larger impact on GCR risk estimates than amounts of radiation shielding or age at exposure (amongst adults). Risks for never-smokers compared to the average U.S. population are estimated to be reduced between 30% and 60% dependent on model assumptions. Lung cancer is the major contributor to the reduction for never-smokers, with additional contributions from circulatory diseases and cancers of the stomach, liver, bladder, oral cavity and esophagus, and leukemia. The relative contribution of CNS risks to the overall space radiation detriment is potentially increased for never-smokers such as most astronauts. Problems in estimating risks for former smokers and the influence of second-hand smoke are discussed. Compared to the LET approximation, the new track structure derived radiation quality functions lead to a reduced risk for relativistic energy particles and increased risks for intermediate energy particles. Revised estimates for the number of safe days in space at solar minimum for heavy shielding conditions are described for never-smokers and the average U.S. population. Results show that missions to near Earth asteroids (NEA) or Mars violate NASA's radiation safety standards with the current levels of uncertainties. Greater improvements in risk estimates for never-smokers are possible, and would be dependent on improved understanding of risk transfer models, and elucidating the role of space radiation on the various stages of disease formation (e.g. initiation, promotion, and progression).

Cucinotta, Francis A.↗

Understanding syringeability and injectability of high molecular weight PEO solution through time-dependent force-distance profiles

Opioid medications play a vital role in treating moderate to severe pain. Unfortunately, many drug misusers and abusers attempt to alter the formulations or properties of these drugs by manipulation, (e.g., crushing, chewing, smoking, snorting, injecting). The intravenous (IV) route is most dangerous to abusers, as the drugs directly enter the circulatory system and produce intense euphoria. To obtain a full understanding of the impact of syringe factors (e.g., needle gauge size, needle length, syringe barrel size), on the ease of injection, we undertook a comprehensive assessment of syringeability and injectability of manipulated abuse-deterrent formulations (ADFs). A texture analyzer-based testing method was developed for the measurement of the resistance force of pulling, holding, and pushing phases of injections. Results showed that the finer needle gauge sizes required higher injection force to withdraw drug solutions. In addition, the syringed liquid volume was highly dependent on needle gauge size, holding time, and sample viscosity. In most cases, a lower needle gauge number and a longer holding time increased the syringed volume. Needle length was highly correlated to injection force (R 2 = 0.99). Using longer needles to inject drug solution requires greater force. Furthermore, large barrel size was correlated to pushing force (R 2 = 0.99); thus, increasing the difficulty of pushing the plunger of a large syringe with one hand. Lastly, relationships between injection force, sample viscosity, and testing conditions were elucidated using a mathematical model, which could be used in the future to assess and predict injection force of solution samples.

60 APPLIED LIFE SCIENCES↗

High Performance Adaptive Physics Refinement to Enable Large-Scale Tracking of Cancer Cell Trajectory

The ability to track simulated cancer cells through the circulatory system, important for developing a mechanistic understanding of metastatic spread, pushes the limits of today's supercomputers by requiring the simulation of large fluid volumes at cellular-scale resolution. To overcome this challenge, we introduce a new adaptive physics refinement (APR) method that captures cellular-scale interaction across large domains and leverages a hybrid CPU-GPU approach to maximize performance. Through algorithmic advances that integrate multi-physics and multi-resolution models, we establish a finely resolved window with explicitly modeled cells coupled to a coarsely resolved bulk fluid domain. In this work we present multiple validations of the APR framework by comparing against fully resolved fluid-structure interaction methods and employ techniques, such as latency hiding and maximizing memory bandwidth, to effectively utilize heterogeneous node architectures. Collectively, these computational developments and performance optimizations provide a robust and scalable framework to enable system-level simulations of cancer cell transport.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing Adaptive Physics Refinement Simulations Through the Addition of Realistic Red Blood Cell Counts

Simulations of cancer cell transport require accurately modeling mm-scale and longer trajectories through a circulatory system containing trillions of deformable red blood cells, whose intercellular interactions require submicron fidelity. Using a hybrid CPU-GPU approach, we extend the advanced physics refinement (APR) method to couple a finely-resolved region of explicitly-modeled red blood cells to a coarsely-resolved bulk fluid domain. We further develop algorithms that: capture the dynamics at the interface of differing viscosities, maintain hematocrit within the cell-filled volume, and move the finely-resolved region and encapsulated cells while tracking an individual cancer cell. Comparison to a fully-resolved fluid-structure interaction model is presented for verification. Finally, we use the advanced APR method to simulate cancer cell transport over a mm-scale distance while maintaining a local region of RBCs, using a fraction of the computational power required to run a fully-resolved model.

Roychowdhury, Sayan↗

Nuclear Physics Network Requirements Review Report

The Energy Sciences Network (ESnet) is the Office of Science’s high-performance network user facility, delivering highly reliable data transport capabilities optimized for the requirements of data-intensive science. In essence, ESnet is the circulatory system that enables the U.S. Department of Energy (DOE) science mission by connecting each and every DOE lab and its user facilities. ESnet is funded and stewarded by the Advanced Scientific Computing Research (ASCR) Program and managed and operated by the Scientific Networking Division at Lawrence Berkeley National Laboratory (LBNL). ESnet is widely regarded as a global leader in the research and education networking community. ESnet connects DOE national laboratories, user facilities, and major experiments so scientists can use remote instruments and computing resources as well as share data with collaborators, transfer large data sets, and access distributed data repositories. While ESnet provides network connectivity, it cannot be characterized as an internet service provider as it is specifically built to provide a range of network services that are tailored to meet the unique requirements of DOE’s data-intensive science.

97 MATHEMATICS AND COMPUTING↗

Fusion Energy Sciences Network Requirements Review. Final Report, April - October 2021

The Energy Sciences Network (ESnet) is the high-performance network user facility for the US Department of Energy (DOE) Office of Science (SC) and delivers highly reliable data transport capabilities optimized for the requirements of data-intensive science. In essence, ESnet is the circulatory system that enables the DOE science mission by connecting all of its laboratories and facilities in the US and abroad. ESnet is funded and stewarded by the Advanced Scientific Computing Research (ASCR) program and managed and operated by the Scientific Networking Division at Lawrence Berkeley National Laboratory (LBNL). ESnet is widely regarded as a global leader in the research and education networking community. Throughout 2021, ESnet and the Office of Fusion Energy Sciences (FES) of the DOE SC organized an ESnet requirements review of FES-supported activities. Preparation for these events included identification of key stakeholders: program and facility management, research groups, and technology providers. Each stakeholder group was asked to prepare formal case study documents about their relationship to the FES program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ARIES Network Requirements Review

The Energy Sciences Network (ESnet) is the high-performance network user facility for the US Department of Energy (DOE) Office of Science (SC) and delivers highly reliable data transport capabilities optimized for the requirements of data-intensive science. In essence, ESnet is the circulatory system that enables the DOE science mission by connecting all of its laboratories and facilities in the US and abroad. ESnet is funded and stewarded by the Advanced Scientific Computing Research (ASCR) program and managed and operated by the Scientific Networking Division at Lawrence Berkeley National Laboratory (LBNL). ESnet is widely regarded as a global leader in the research and education networking community. On May 1, 2021, ESnet and the DOE Office of Energy Efficiency and Renewable Energy (EERE), organized an ESnet requirements review of the ARIES (Advanced Research on Integrated Energy Systems) platform. Preparation for this event included identification of key stakeholders to the process: program and facility management, research groups, technology providers, and a number of external observers. These individuals were asked to prepare formal case study documents in order to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗