Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLOSED LOOP SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

External Tank CIL Closed Loop Verification System

Lockheed Martin was requested to develop a closed loop CIL system following the Challenger accident. The system that was developed has proven to be very robust with minimal problems since implementation, having zero escapes in the last 7 years (27 External Tanks). We are currently investigating expansion of the CIL Closed Loop system to include "MI" CILs.

Hartley, Eugene A., Jr.↗

Similarity Metrics for Closed Loop Dynamic Systems

To what extent and in what ways can two closed-loop dynamic systems be said to be "similar?" This question arises in a wide range of dynamic systems modeling and control system design applications. For example, bounds on error models are fundamental to the controller optimization with modern control design methods. Metrics such as the structured singular value are direct measures of the degree to which properties such as stability or performance are maintained in the presence of specified uncertainties or variations in the plant model. Similarly, controls-related areas such as system identification, model reduction, and experimental model validation employ measures of similarity between multiple realizations of a dynamic system. Each area has its tools and approaches, with each tool more or less suited for one application or the other. Similarity in the context of closed-loop model validation via flight test is subtly different from error measures in the typical controls oriented application. Whereas similarity in a robust control context relates to plant variation and the attendant affect on stability and performance, in this context similarity metrics are sought that assess the relevance of a dynamic system test for the purpose of validating the stability and performance of a "similar" dynamic system. Similarity in the context of system identification is much more relevant than are robust control analogies in that errors between one dynamic system (the test article) and another (the nominal "design" model) are sought for the purpose of bounding the validity of a model for control design and analysis. Yet system identification typically involves open-loop plant models which are independent of the control system (with the exception of limited developments in closed-loop system identification which is nonetheless focused on obtaining open-loop plant models from closed-loop data). Moreover the objectives of system identification are not the same as a flight test and hence system identification error metrics are not directly relevant. In applications such as launch vehicles where the open loop plant is unstable it is similarity of the closed-loop system dynamics of a flight test that are relevant.

Whorton, Mark S.↗

Monitoring Digital Closed-Loop Feedback Systems

A technique of monitoring digital closed-loop feedback systems has been conceived. The basic idea is to obtain information on the performances of closed-loop feedback circuits in such systems to aid in the determination of the functionality and integrity of the circuits and of performance margins. The need for this technique arises as follows: Some modern digital systems include feedback circuits that enable other circuits to perform with precision and are tolerant of changes in environment and the device s parameters. For example, in a precision timing circuit, it is desirable to make the circuit insensitive to variability as a result of the manufacture of circuit components and to the effects of temperature, voltage, radiation, and aging. However, such a design can also result in masking the indications of damaged and/or deteriorating components. The present technique incorporates test circuitry and associated engineering-telemetry circuitry into an embedded system to monitor the closed-loop feedback circuits, using spare gates that are often available in field programmable gate arrays (FPGAs). This technique enables a test engineer to determine the amount of performance margin in the system, detect out of family circuit performance, and determine one or more trend(s) in the performance of the system. In one system to which the technique has been applied, an ultra-stable oscillator is used as a reference for internal adjustment of 12 time-to-digital converters (TDCs). The feedback circuit produces a pulse-width-modulated signal that is fed as a control input into an amplifier, which controls the circuit s operating voltage. If the circuit s gates are determined to be operating too slowly or rapidly when their timing is compared with that of the reference signal, then the pulse width increases or decreases, respectively, thereby commanding the amplifier to increase or reduce, respectively, its output level, and "adjust" the speed of the circuits. The nominal frequency of the TDC s pulse width modulated outputs is approximately 40 kHz. In this system, the technique is implemented by means of a monitoring circuit that includes a 20-MHz sampling circuit and a 24-bit accumulator with a gate time of 10 ms. The monitoring circuit measures the duty cycle of each of the 12 TDCs at a repetition rate of 28 Hz. The accumulator content is reset to all zeroes at the beginning of each measurement period and is then incremented or decremented based of the value of the state of the pulse width modulated signal. Positive or negative values in the accumulator correspond to duty cycles greater or less, respectively, than 50 percent.

Katz, Richard↗

COMSOL Models and Simulation Results for Closed-Loop Geothermal Systems with Thermal Enhancements

The Closed-Loop Geothermal Working Group and the National Renewable Energy Laboratory (NREL) have studied the performance of disc-shaped and linear thermal enhancements (conductive material introduced around a wellbore) in closed-loop geothermal systems. COMSOL models were developed to investigate the increase in heat production in systems with thermal enhancements compared to those without, across a range of scenarios. This dataset includes two example COMSOL models, a summary of the simulation results, and a link to an accompanying paper. Studied are idealized versions of two thermal enhancement designs: (1) existing or newly created fractures surrounding the wellbore, filled with highly conductive material, and (2) a 'fishbone structure,' where short wellbores are drilled radially outward from the main wellbore and filled with highly conductive material.

15 GEOTHERMAL ENERGY↗

System identification from closed-loop data with known output feedback dynamics

This paper presents a procedure to identify the open loop systems when it is operating under closed loop conditions. First, closed loop excitation data are used to compute the system open loop and closed loop Markov parameters. The Markov parameters, which are the pulse response samples, are then used to compute a state space representation of the open loop system. Two closed loop configurations are considered in this paper. The closed loop system can have either a linear output feedback controller or a dynamic output feedback controller. Numerical examples are provided to illustrate the proposed closed loop identification method.

Phan, Minh↗

Amplification of Reynolds number dependent processes by wave distortion

A system using a hot-wire transducer as an analog of a liquid droplet of propellant was employed to investigate the ingredients of the acoustic instability of liquid-propellant rocket engines. It was assumed that the combustion process was vaporization-limited and that the combustion chamber was acoustically similar to a closed-closed right-circular cylinder. Before studying the hot-wire closed-loop system (the analog system), a microphone closed-loop system, which used the response of a microphone as the source of a linear feedback exciting signal, was investigated to establish the characteristics of self-sustenance of acoustic fields. Self-sustained acoustic fields were found to occur only at resonant frequencies of the chamber. In the hot-wire closed-loop system, the response of hot-wire anemometer was used as the source of the feedback exciting signal. The self-sustained acoustic fields which developed in the system were always found to be harmonically distorted and to have as their fundamental frquency a resonant frequency for which there also existed a second resonant frequency which was approximately twice the fundamental frequency.

Ventrice, M. B.↗

Locally optimal-digital redesign of continuous-time systems

This paper presents a new optimal digital redesign technique for finding a dynamic digital control law from the given continuous-time counterpart by minimizing a local quadratic performance index. The quadratic performance index is chosen as the integral of the weighted squared difference between the states of the original closed-loop system and those of the digitally controlled closed-loop system at any instant between each sampling period. The developed optimal digital redesign control law enables the states of the digitally controlled closed-loop system 10 closely match those of the original closed-loop system at any instant between each sampling period, and it can easily be implemented using microcomputers with a relatively large sampling period.

Shieh, Leang-San↗

Application of adaptive antenna techniques to future commercial satellite communication

The purpose of this contract was to identify the application of adaptive antenna technique in future operational commercial satellite communication systems and to quantify potential benefits. The contract consisted of two major subtasks. Task 1, Assessment of Future Commercial Satellite System Requirements, was generally referred to as the Adaptive section. Task 2 dealt with Pointing Error Compensation Study for a Multiple Scanning/Fixed Spot Beam Reflector Antenna System and was referred to as the reconfigurable system. Each of these tasks was further sub-divided into smaller subtasks. It should also be noted that the reconfigurable system is usually defined as an open-loop system while the adaptive system is a closed-loop system. The differences between the open- and closed-loop systems were defined. Both the adaptive and reconfigurable systems were explained and the potential applications of such systems were presented in the context of commercial communication satellite systems.

Ersoy, L.↗

Application of adaptive antenna techniques to future commercial satellite communications. Executive summary

The purpose of this contract was to identify the application of adaptive antenna technique in future operational commercial satellite communication systems and to quantify potential benefits. The contract consisted of two major subtasks. Task 1, Assessment of Future Commercial Satellite System Requirements, was generally referred to as the Adaptive section. Task 2 dealt with Pointing Error Compensation Study for a Multiple Scanning/Fixed Spot Beam Reflector Antenna System and was referred to as the reconfigurable system. Each of these tasks was further subdivided into smaller subtasks. It should also be noted that the reconfigurable system is usually defined as an open-loop system while the adaptive system is a closed-loop system. The differences between the open- and closed-loop systems were defined. Both the adaptive and reconfigurable systems were explained and the potential applications of such systems were presented in the context of commercial communication satellite systems.

Ersoy, L.↗

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems↗

Design of biomass management systems and components for closed loop life support systems

The design of a biomass management system (BMS) for use in a closed loop support system is presented by University of Florida students as the culmination of two design courses. The report is divided into two appendixes, each presenting the results of one of the design courses. The first appendix discusses the preliminary design of the biomass management system and is subdivided into five subsystems: (1) planting and harvesting, (2) food management, (3) resource recovery, (4) refurbishing, and (5) transport. Each subsystem is investigated for possible solutions to problems, and recommendations and conclusions for an integrated BMS are discussed. The second appendix discusses the specific design of components for the BMS and is divided into three sections: (1) a sectored plant growth unit with support systems, (2) a container and receiving mechanism, and (3) an air curtain system for fugitive particle control. In this section components are designed, fabricated, and tested.

Nevill, Gale E., Jr.↗

On the evaluation of expected performance cost for partially observed closed-loop stochastic systems

New methods are presented for evaluating the expected performance cost of partially observed closed-loop stochastic systems. When the variances of the process statistics are small, a linearized model of the closed-loop stochastic system is defined for which the expected cost can be evaluated by recursion on a set of purely deterministic difference equations. When the variances of the process statistics are large, the linearized model can be used in the control variate method of variance reduction for reducing the number of sample paths required for effective Monte Carlo estimation.

Bayard, D. S.↗

Evaluating Heat Extraction Performance of Closed-Loop Geothermal Systems with Thermally Conductive Enhancements in Conduction-Only Reservoirs: Preprint

We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.

advanced geothermal systems↗

Numerical Simulation of Critical Factors Controlling Heat Extraction from Geothermal Systems Using a Closed-Loop Heat Exchange Method

Closed-loop heat exchange for geothermal energy production involves injecting working fluid down a well that extends through the geothermal resource over a significant length to absorb heat by conduction through the well pipe. The well then needs to return to the surface for energy recovery and fluid re-injection to complete the cycle. We have carried out mixed convective-conductive fluid-flow modeling using a wellbore flow model for TOUGH2 called T2Well to investigate the critical factors that control closed-loop geothermal energy recovery. T2Well solves a mixed explicit-implicit set of momentum equations for flow in the pipe with full coupling to the implicit three-dimensional integral finite difference equations for Darcy flow in the porous medium. T2Well has the option of modeling conductive heat flow from the porous medium to the pipe by means of a semi-analytical solution which makes the computation very efficient because the porous medium does not have to be discretized. When the fully three-dimensional option is chosen, the porous medium is discretized and heat flow to the pipe is by conduction and convection, depending on reservoir permeability and other factors. Simulations of the closed-loop system for a variety of parameter values have been carried out to elucidate the heat recovery process. To the extent that convection may occur to aid in heat delivery to the pipe, the permeability of the geothermal reservoir, whether natural or stimulated, is an important property in heat extraction. The injection temperature and flow rate of the working fluid strongly control the ultimate energy recovery. Pipe diameter also plays a strong role in heat extraction, but is correlated with flow rate. Similarly, the choice of working fluid plays an important role, with water showing better heat extraction than CO2 for certain flow rates, while the CO2 has higher pressure at the production wellhead which can aid in surface energy recovery. In general, we find complex interactions between the critical factors that will require advanced computational approaches to fully optimize.

Oldenburg, Curtis↗

Design of biomass management systems and components for closed loop life support systems

The goal of the EGM 4000/1 Design class was to investigate a Biomass Management System (BMS) and design, fabricate, and test components for biomass management in a closed-loop life support system (CLLSS). The designs explored were to contribute to the development of NASA's Controlled Ecological Life Support System (CELSS) at Kennedy Space Center. Designs included a sectored plant growth unit, a container and transfer mechanism, and an air curtain system for fugitive particle control. The work performed by the class members is summarized.

Source record↗

Construction and parameterization of all static and dynamic H2-optimal state feedback solutions, optimal fixed modes, and fixed decoupling zeros

This paper considers an H2 optimization problem via state feedback. The class of problems dealt with here are general singular type which have a left invertible transfer matrix function from the control input to the controlled output. This class subsumes the regular H2 optimization problems. The paper constructs and parameterizes all the static and dynamic H2 optimal state feedback solutions. Moreover, all the eigenvalues of an optimal closed-loop system are characterized. All optimal closed-loop systems share a set of eigenvalues which are termed here as the optimal fixed modes. Every H2 optimal controller must assign among the closed-loop eigenvalues the set of optimal fixed modes. This set of optimal fixed modes includes a set of optimal fixed decoupling zeros which shows the minimum absolutely necessary number and locations of pole-zero cancellations present in any H2 optimal design. It is shown that both the sets of optimal fixed modes and optimal fixed decoupling zeros do not vary depending upon whether the static or the dynamic controllers are used.

Chen, Ben M.↗

Flight control synthesis for flexible aircraft using Eigenspace assignment

The use of eigenspace assignment techniques to synthesize flight control systems for flexible aircraft is explored. Eigenspace assignment techniques are used to achieve a specified desired eigenspace, chosen to yield desirable system impulse residue magnitudes for selected system responses. Two of these are investigated. The first directly determines constant measurement feedback gains that will yield a close-loop system eigenspace close to a desired eigenspace. The second technique selects quadratic weighting matrices in a linear quadratic control synthesis that will asymptotically yield the close-loop achievable eigenspace. Finally, the possibility of using either of these techniques with state estimation is explored. Application of the methods to synthesize integrated flight-control and structural-mode-control laws for a large flexible aircraft is demonstrated and results discussed. Eigenspace selection criteria based on design goals are discussed, and for the study case it would appear that a desirable eigenspace can be obtained. In addition, the importance of state-space selection is noted along with problems with reduced-order measurement feedback. Since the full-state control laws may be implemented with dynamic compensation (state estimation), the use of reduced-order measurement feedback is less desirable. This is especially true since no change in the transient response from the pilot's input results if state estimation is used appropriately. The potential is also noted for high actuator bandwidth requirements if the linear quadratic synthesis approach is utilized. Even with the actuator pole location selected, a problem with unmodeled modes is noted due to high bandwidth. Some suggestions for future research include investigating how to choose an eigenspace that will achieve certain desired dynamics and stability robustness, determining how the choice of measurements effects synthesis results, and exploring how the phase relationships between desired eigenvector elements effects the synthesis results.

Davidson, J. B.↗

Equivalent Circuit Models of Voltage-Controlled Dual Active Bridge Converters: Preprint

In this paper, we introduce a new method of modeling voltage-controlled dual active bridge converters as equivalent circuits. What makes the proposed model unique is that the entire closed loop system converter and control are represented together in one equivalent circuit. Since the full system can be recast as a circuit, this allows for deeper insights on how the closed-loop system performs and for the direct application of circuit analysis techniques. In particular, we reveal how classical control notions can be understood as circuit laws.

24 POWER TRANSMISSION AND DISTRIBUTION↗