Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLOTHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Porous CoFe{sub 2}O{sub 4} nanowire arrays on carbon cloth as binder-free anodes for flexible lithium-ion batteries

Highlights: • Hierarchal CoFe{sub 2}O{sub 4} nanowire arrays are directly grown on flexible carbon cloth. • Porous CoFe{sub 2}O{sub 4} nanowires are composed of many nanocrystals of 20–40 nm. • CoFe{sub 2}O{sub 4} nanowire arrays exhibit excellent rate capability and cycling stability. • Integrated CoFe{sub 2}O{sub 4}/carbon cloth electrodes show high flexibility and areal capacity. - Abstract: A three-dimensional CoFe{sub 2}O{sub 4} nanowire array on carbon cloth was fabricated with a hydrothermal method together with a post-annealing treatment. As a binder-free and flexible anode material for LIBs, it showed an improved electrochemical performance with high cycling stability and excellent rate capability. It exhibited an initial discharge capacity of 1615 mAh g{sup −1} and retained a reversible capacity of about 1204 mAh g{sup −1} after 200 cycles at a specific current of 500 mA g{sup −1}. The high capacity, outstanding rate performance and cycling stability can be attributed to the special configuration of hierarchal porous CoFe{sub 2}O{sub 4} nanowires on carbon cloth, which possess many advantages like short diffusion length, easy strain relaxation and fast electron transport. Moreover, the integrated CoFe{sub 2}O{sub 4} nanowires/carbon cloth electrode shows high flexibility and high areal capacity (2.41 mAh cm{sup −2}), which makes it suitable for use as a binder-free anode to build flexible LIBs.

36 MATERIALS SCIENCE↗

Integrated carbon cloth supported LiFePO4/N-C films as high-performance cathode for lithium ion batteries

Highlights: • Construct carbon cloth supported LiFePO{sub 4}/N-C films via hydrothermal. • The LiFePO{sub 4}/N-C films show high capacity and good cycles. • Carbon cloth and N-C layer work together to provide fast ion/electron transfer. - Abstract: Fabricating advanced cathode is critical for the development of high-performance lithium ion batteries (LIBs). In this work, we develop a facile hydrothermal method for construction of LiFePO{sub 4}/N-C films on the carbon cloth forming integrated binder-free cathode. The LiFePO{sub 4}/N-C films are composed of interconnected nanoscale LiFePO{sub 4}/N-C particles with diameters of 100–200 nm. High porosity and good adhesion are obtained in the carbon cloth supported LiFePO{sub 4}/N-C films (CC + LiFePO{sub 4}/N-C films). As compared to the LiFePO{sub 4}/C powder nanoparticles, the CC + LiFePO{sub 4}/N-C films show much better electrochemical properties with higher capacities, smaller polarization and better high-rate cycling life. A high capacity of 169 mAh g{sup −1} at 1C is achieved for the carbon cloth supported LiFePO{sub 4}/N-C films, superior to the LiFePO{sub 4}/C powder nanoparticles (154 mAh g{sup −1} at 5C). This enhancement is owing to the unique integrated porous architecture and N-C coating. Our work shows a new way to construct integrated cathode for application in LIBs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Heat Pump Clothes Dryer Model Development

A heat pump clothes dryer (HPCD) is an innovative appliance that uses a vapor compression system to dry clothes. Air circulates in a closed loop through the drum, so no vent is required. The condenser heats air to evaporate moisture out of the clothes, and the evaporator condenses water out of the air stream. As a result, the HPCD can achieve 50% energy savings compared to a conventional electric resistance dryer. We developed a physics-based, quasi-steady-state HPCD system model with detailed heat exchanger and compressor models. In a novel approach, we applied a heat and mass transfer effectiveness model to simulate the drying process of the clothes load in the drum. The system model is able to simulate the inherently transient HPCD drying process, to size components, and to reveal trends in key variables (e.g. compressor discharge temperature, power consumption, required drying time, etc.) The system model was calibrated using experimental data on a prototype HPCD. In the paper, the modeling method is introduced, and the model predictions are compared with experimental data measured on a prototype HPCD.

Heat Pump Clothes Dryer↗

Self-supported MoO 2 /MoS 2 nano-sheets embedded in a carbon cloth as a binder-free substrate for high-energy lithium–sulfur batteries

As one of the most prospective candidates for next-generation rechargeable batteries, lithium-sulfur (Li-S) batteries currently still encounter great challenges associated with the low conductivity, severe shuttle effects, and sluggish redox kinetics. Herein, a self-supported sulfur host is fabricated by an in-situ growth of MoO 2 /MoS 2 nano-sheets on a carbon cloth (CC). First, carbon cloth serves as a good template for the morphology-controlled synthesis of nanostructured materials, which not only alleviates the agglomeration of MoO2/MoS2, but also enhances the flexibility and mechanical strengthen of the hybrid architecture as a free-standing host. Second, the polysulfide-trapping ability can be greatly enhanced by both physical and chemical adsorption from the MoO 2 /MoS 2 -anchored carbon cloth. Moreover, the partially sulfurized MoO 2 /MoS 2 nano-sheets integrate the benefits of conductive MoO 2 and sulfiphilic MoS 2 , thus facilitating fast charge transfer and redox kinetics of polysulfide conversion. As a result, these attributes enable the host to hold a high sulfur loading (up to 7.6 mg cm -2 ), which exceeds most of the reported carbon cloth-related cathode work in the literature. Furthermore, the Li-S cells can achieve a high peak capacity of 1350 mA h g -1 , excellent rate capability (C/20 - 2C rate), impressive areal capacity (up to 6.3 mA h cm -2 ), and a high capacity retention of 85% after 100 cycles.

25 ENERGY STORAGE↗

Review of particle deposition to and removal from clothing, skin, and hair after a radioactive airborne dispersal event

Explosive Radiological Dispersal Devices (RDD) – aka dirty bombs – are seen as a credible method to carry out a radiological terror attack. After exploding a radioactive source, the radionuclide-laden plume will be blown downwind of ground zero, with particles falling out and potentially depositing on people caught in and under the cloud. Some of these people may not show any sign of radiation sickness and therefore not realize they have been contaminated and may take the radioactive particulate with them on their daily activities, thus spreading the radioactive particulate outside the initially contaminated area. This paper reviews the scientific literature to better understand the rate at which particulate deposits on and is removed from the different “surfaces” of a person, i.e., hair, skin, and clothing. Prior research indicates that: 1) particle deposition is usually higher on skin than on hair and clothing; 2) particle deposition is greater for a person with higher skin moisture, 3) stronger wind increases the deposition flux onto a person, and 4) the fraction of particulate deposited on the hair, skin, and clothing respectively depends on the length of the hair, assuming all the hair surface is available for deposition. The studies taken into consideration show that the largest uncertainty in particulate deposition onto a person is due to clothing type because of the different possible weave arrangements and tightness which translate into differences in actual surface area and surface roughness. A factor of 2-to-20 variation in deposition rate was found. Removal of the particulate from the contaminated person may be due to wind, a person's movement, and/or contact transfer, i.e., by touching a different clean surface. Experiments show that the majority of the particulate is resuspended within 2–6 h mostly depending on the intensity of physical activity. The largest uncertainty in particulate removal from skin depends on the skin moisture, transfer rate of single-contact, and how many objects/people a person touches per hour. No data for hair were found for particle removal and resuspension. The studies considered did not utilize radionuclides directly; however, data on adhesion of radioactive vs. their non-radioactive counterpart have shown that the uncertainty due to the radioactivity of the particles is lower than that due to other factors. In conclusion, an idealized scenario involving a single building in the path of the cloud showed the impact of building-influenced flow on the cloud transport path and mixing, which affects the radiological dose the downwind population is exposed to and consequently the health effects.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Model-Based Air Flow Path Optimization of Heat Pump Clothes Dryer

A heat pump clothes dryer (HPCD) uses a vapor compression system to dry clothes. The condenser heats air, which passes through the drum to evaporate moisture out of the clothes, and the evaporator condenses water out of the air stream. As a result, the HPCD can achieve 50% energy savings compared to a conventional electric resistance dryer. In this work we developed a physics-based, quasi-steady-state HPCD system model with detailed heat exchanger and compressor models. The system model can simulate the inherently transient HPCD drying process, to size components, and to reveal trends in key variables (e.g. compressor discharge temperature, power consumption, required drying time, etc.) The system model was calibrated using experimental data from a prototype HPCD. Air leakages, in and out, along the closed air circulation path of HPCD cause varied effects on the performance. Understanding the location, magnitude, and direction of air leakage of the heat pump clothes dryer is critical for accurately characterizing the performance and developing a high-performance design. The system model was used to reveal the impacts. In addition, model-based parametric optimizations were conducted to design the HPCD charge inventory, flow rate, air path and leak points for optimum performance.

Shen, Bo↗

Experimental Measurements of Clothes Dryer Drum Heat and Mass Transfer Effectiveness

Accurate system modeling of a clothes dryer requires a drum component model that displays correct trends with respect to changing conditions. In this work, a model of drum heat and mass transfer effectiveness is adopted. Within this framework, experimental measurements of drum effectiveness are investigated with respect to several variables: drum volume, load mass, cloth type, drum volumetric air flow rate, and drum entering air temperature. These data can inform the modeling and simulation of any clothes dryer with horizontal-axis, axial-flow tumble-type clothes dryer drum.

Gluesenkamp, Kyle R.↗

Improving bioenergy recovery from municipal wastewater with a novel cloth-filter anaerobic membrane bioreactor

Anaerobic membrane bioreactors (AnMBR) have been used for treating high-strength industrial wastewater at full-scale and the potential to use them for mainstream municipal wastewater treatment presents an important opportunity to turn energy-intensive plants into net-energy producers. However, several limitations of the AnMBR technology have prevented their adoption in the municipal wastewater industry, namely, high membrane cleaning energy demand and low membrane flux. This study demonstrated a novel AnMBR configuration that uses a commercially available cloth filter technology to address the key limitations of cleaning energy and membrane flux. The cloth filter anaerobic membrane bioreactor (CFAnMBR) is comprised of an anaerobic fixed-film bioreactor coupled with a cloth filter membrane with nominal pore size of 5 µm. The pilot CFAnMBR was operated for 150 days through the winter at a municipal wastewater plant in central Illinois (minimum/average influent temperature 5/13°C). The CFAnMBR increased membrane flux by more than 2 orders of magnitude (3,649 ± 1,246 L per meter squared per hour) and reduced cleaning energy demand by 78%—92% (0.0085 kWh/m 3 ) relative to previously reported AnMBR configurations. With the CFAnMBR, average chemical oxygen demand and total suspended solids removal were 66% and 91%, respectively, and were shown to be increased up to 88% and 96% by in-line coagulant dosing with ferric chloride. Average headspace methane yield was 154 mL CH 4 /g COD removed by the end of the study period with influent temperatures of 11°C± 4°C. The CFAnMBR resolves major limitations of AnMBR technology by employing a commercially-available technology already used for other municipal wastewater treatment applications.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Bolus Materials to Highly Absorbent Polypropylene and Rayon Cloth

This study assesses the utility of a highly absorbent polypropylene and rayon cloth (HAPRC) as a bolus material in radiation therapy. A comparison of various bolus materials used clinically at our center to the test bolus material, water-saturated HAPRC, was conducted. The reproducibility of the physical density was assessed by computerized tomography (CT) scanning the water-saturated HAPRC on a uniform density block phantom on multiple occasions, allowing the cloth to dry fully between subsequent CT scans. The cloth was found to have a consistent physical density between 0.8 and 1.0 g/cm{sup 3}. To evaluate the dosimetric impact of the various bolus materials, metal oxide semiconductor field effect transistor dosimetry measurements were performed for a 6 MV treatment beam on the anterior surface of an anthropomorphic thorax phantom. The ability of the bolus material to conform to an irregular surface was assessed by CT scanning the various bolus materials overlaying the nose of an anthropomorphic head phantom and another irregularly shaped test object. The HAPRC conforms well to irregular contours and is relatively inexpensive compared to Superflab and thermoplastic sheets. Before implementing the material into the clinical setting, an appropriate process for laundering the material should be determined, for hygienic reasons.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Packaging and Modular Control of Thermoelectric Clothes Dryer, With Performance Evaluation

This paper provides an overview of a thermoelectric heat pump clothes dryer which was developed with the aim of reducing the significant primary energy consumption attributed to residential electric clothes drying in the United States (623 TBtu/yr). The use of thermoelectric modules in place of the conventional electric resistance heater resulted in a 40% reduction in the energy consumption of the system, compared to the minimum energy efficiency standard. This was achieved for the first time for a standard test load of 8.45 lb, using a clothes dryer prototype with a thermoelectric heat pump module as the sole heating mechanism. The current experimental prototype was developed after extensive modeling, system design and control optimization, and experimental system-level evaluation of control parameters. The demonstration of improved energy consumption has laid the foundation for future development of this technology.

Patel, Viral↗

Thermoelectric heat pump clothes dryer design optimization

Clothes dryers based on thermoelectric (TE) heat pumps have the potential to save significant energy compared with the conventional electric resistance technology that is widespread today, without using any refrigerant fluid. In this work, guided by a validated system model, design and control improvements were implemented on an experimental prototype to optimize the dryer performance (duration to dry a load, and energy consumed per unit cloth mass). Starting from a fixed TE area, the physical design variables of interest were (1) the use of vented or ventless configuration, (2) the heat sink geometry, (3) the selection of blower and (4) the selection of motor used to drive drum rotation. The control variables of interest were (5) the average electrical current supplied to each bank of TEs and (6) the current profile for each bank during the drying time. By optimizing each of these choices in the model and applying the resulting design choices on the prototype, the experimentally measured efficiency of the TE prototype was improved to 2.96 kg/kWh (6.52 lb/kWh), 38% better than an Energy Star qualified electric resistance dryer, and within 14% of a vapor compression heat pump clothes dryer.

Goodman, Dakota↗

Clothes Dryer Automatic Termination Evaluation

Volume 2: Improved Sensor and Control Designs Many residential clothes dryers on the market today provide automatic cycles that are intended to stop when the clothes are dry, as determined by the final remaining moisture content (RMC). However, testing of automatic termination cycles has shown that many dryers are susceptible to over-drying of loads, leading to excess energy consumption. In particular, tests performed using the DOE Test Procedure in Appendix D2 of 10 CFR 430 subpart B have shown that as much as 62% of the energy used in a cycle may be from over-drying. Volume 1 of this report shows an average of 20% excess energy from over-drying when running automatic cycles with various load compositions and dryer settings. Consequently, improving automatic termination sensors and algorithms has the potential for substantial energy savings in the U.S.

algorithm↗

Experimental evaluation and thermodynamic system modeling of thermoelectric heat pump clothes dryer

Electric clothes dryers consume about 6% of US residential electricity consumption. Using a solid-state technology without refrigerant, thermoelectric (TE) heat pump dryers have the potential to be more efficient than units based on electric resistance and less expensive than units based on vapor compression. This study presents a steady state TE dryer model, and validates the model against results from an experimental prototype. The system model is composed of a TE heat pump element model coupled with a psychrometric dryer sub-model. Experimental results had energy factors (EFs) of up to 2.95 kg of dry cloth per kWh (6.51 lb c /kWh), with a dry time of 159 min. A faster dry time of 96 min was also achieved at an EF of 2.54 kg c /kWh (5.60 lb c /kWh). The model was able to replicate the experimental results within 5% of EF and 5% of dry time values. Finally, the results are used to identify important parameters that affect dryer performance, such as relative humidity of air leaving the drum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel method to determine air leakage in heat pump clothes dryers

A heat pump clothes dryer offers the potential to save a significant amount of energy as compared with conventional vented electric dryers. Although heat pump clothes dryers (HPCD) offer higher energy efficiency; it has been observed that they are prone to air leakages, which inhibits the HPCD's gain in efficiency. This study serves to develop a novel method of quantifying leakage, and to determine specific leakage locations in the dryer drum and air circulation system. The basis of this method is the American Society of Testing and Materials (ASTM) standard E779 10, which is used to determine air leakage area in a household ventilation system through fan pressurization. This ASTM method is adapted to the dryer system, and the leakage area is determined by an analysis of the leakage volumetric flow - pressure relationship. Easily accessible leakage points were quantified: the front and back crease (in the dryer drum), the leakage in the dryer duct, the air filter, and the remaining leakage in the drum. The procedure allows investigators to determine major components contributing to leakage in HPCDs, thus improving component design features that result in more efficient HPCD systems.

42 ENGINEERING↗

Investigation of radiation keeping property of barite coated cloth via image processing method

Preservative clothes which are able to absorb radiation beam are needed not only for saving people working at radioactive environment but also for saving others from natural and man-made radiation sources we are exposed in daily life. Barite is a mineral which can be used for armour plating because of high atomic numbered element barium constituent of barite. In this study, armour plating property of barite was applied to fabrics. Barite coated fabric having characteristic of keeping radiation was obtained by penetrating barite on cloth via coating method. Radiation keeping property of fabrics obtained was determined via image processing. The results of experiments showed that barite coated fabrics have blocked radiation more than normal fabrics have done.

61 RADIATION PROTECTION AND DOSIMETRY↗

Next-Generation Desiccant-Based Gas Clothes Dryer Systems

The goal of the project is to develop an advanced gas clothes dryer system demonstrating significant improvements in fuel efficiency and drying performance compared to current gas clothes dryer technologies. The new system decouples latent and sensible loads to effectively utilize the latent heat associated with laundry moisture as an advantageous energy source. In other words, the system captures the waste latent heat from moisture produced during the fabric-drying process and reuses it to improve drying efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗