Search NASA⌕ Search

SEARCH · Search NASA

Results for “CMR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CMR-STAC Overview

Explore the source record for details and available documents.

CMR↗

Total Energy CMR Production

The following outlines the optimized pulsed laser deposition (PLD) procedure used to prepare Nd{sub 0.67}Sr{sub 0.33}MnO{sub 3} (NSMO) temperature sensors at Towson University (Prof. Rajeswari Kolagani) for the LCLS XTOD Total Energy Monitor. The samples have a sharp metal/insulator transition at T {approx} 200 K and are optimized for operation at T {approx} 180 K, where their sensitivity is the highest. These samples are epitaxial multilayer structures of Si/YSZ/CeO/NSMO, where these abbreviations are defined in table 1. In this heterostructure, YSZ serves as a buffer layer to prevent deleterious chemical reactions, and also serves to de-oxygenate the amorphous SiO{sub 2} surface layer to generate a crystalline template for epitaxy. CeO and BTO serve as template layers to minimize the effects of thermal and lattice mismatch strains, respectively. More details on the buffer and template layer scheme are included in the attached manuscript accepted for publication in Sensor Letters (G. Yong et al., 2008).

36 MATERIALS SCIENCE↗

CMR Metadata Curation

This talk explains the ongoing metadata curation activities in the Common Metadata Repository. It explores tools that exist today which are useful for building quality metadata and also opens up the floor for discussions on other potentially useful tools.

metadata↗

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

Background: Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR). Methods and results: Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correlation coefficients .98 (95% CI .97-.99), and .98 (95% CI 0.97-.99), respectively]. The mean LVM mass values were 151 ± 44 g on CMR, 151 ± 43 g with 4DM (P = NS vs CMR), and 157 ± 42 g with ECTb (P < .001 vs CMR; P = .007 vs 4DM) CZT images. There was an excellent correlation between LV mass values between CMR and both 4DM (R{sup 2} = .95; P < .001) and ECTb (R{sup 2} = .98; P < .001) with narrow limits of agreement (− 13.6% to + 13.4% for 4DM, and − 5.6% to + 14.1% for ECTb). Conclusions: The evaluation of LV mass is feasible on CZT images, showing excellent agreement with CMR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Structurally and Magnetically Modified Nanoclusters in Colossal Magnetoresistance

It is generally accepted that electronic and magnetic phase separation is the origin of many of exotic properties of strongly correlated electron materials, such as colossal magnetoresistance (CMR), an unusually large variation in the electrical resistivity under applied magnetic field. In the simplest picture, the two competing phases are those associated with the material state on either side of the phase transition. Those phases would be paramagnetic insulator and ferromagnetic metal for the CMR effect in doped manganites. It has been speculated that a critical component of the CMR phenomenon is nanoclusters with quite different properties than either of the terminal phases during the transition. However, the role of these nanoclusters in the CMR effect remains elusive because the physical properties of the nanoclusters are hard to measure when embedded in bulk materials. Here we show the unexpected behavior of the nanoclusters in the CMR compound La{sub 1-x}Ca{sub x}MnO{sub 3} (0.4 {le} x < 0.5) by directly correlating transmission electron microscopy observations with bulk measurements. The structurally modified nanoclusters at the CMR temperature were found to be ferromagnetic and exhibit much higher electrical conductivity than previously proposed. Only at temperatures much below the CMR transition, the nanoclusters are antiferromagnetic and insulating. These findings substantially alter the current understanding of these nanoclusters on the material's functionality and would shed light on the microscopic study on the competing spin-lattice-charge orders in strongly correlated systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Colossal Magnetoresistance without Mixed Valence in a Layered Phosphide Crystal

Materials with strong magnetoresistive responses are the backbone of spintronic technology, magnetic sensors, and hard drives. Among them, manganese oxides with a mixed valence and a cubic perovskite structure stand out due to their colossal magnetoresistance (CMR). A double exchange interaction underlies the CMR in manganates, whereby charge transport is enhanced when the spins on neighboring Mn 3+ and Mn 4+ ions are parallel. Prior efforts to find different materials or mechanisms for CMR resulted in a much smaller effect. Here an enormous CMR at low temperatures in EuCd 2 P 2 without manganese, oxygen, mixed valence, or cubic perovskite structure is shown. EuCd 2 P 2 has a layered trigonal lattice and exhibits antiferromagnetic ordering at 11 K. The magnitude of CMR (10(4)%) in as-grown crystals of EuCd 2 P 2 rivals the magnitude in optimized thin films of manganates. In this work, the magnetization, transport, and synchrotron X-ray data suggest that strong magnetic fluctuations are responsible for this phenomenon. The realization of CMR at low temperatures without heterovalency leads to a new regime for materials and technologies related to antiferromagnetic spintronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Hypertrophic Cardiomyopathy: Newer Echo and MRI Approaches

Purpose of Review: This review discusses the basic and evolving echocardiographic and cardiac magnetic resonance (CMR) approaches in the diagnosis and management of patients with hypertrophic cardiomyopathy (HCM). Recent Findings: Newer imaging technologies and techniques in both echocardiography and CMR have proved to add incremental value to our understanding of HCM. 3D reconstruction in echocardiography and CMR allows for more accurate morphological and volumetric assessment of the left ventricle. Echocardiographic and CMR-based left atrial assessment, including for its mechanical properties, has been shown to be correlated to outcomes and development of atrial fibrillation. Tissue characterization and scar burden quantification by late gadolinium enhancement on CMR has revolutionized our understanding of fibrotic processes in HCM and their contribution to disease severity and clinical outcomes. Summary: Cardiac imaging plays a crucial role in HCM patients. Using echocardiography and CMR as complementary modalities allows for improved diagnostics, optimization of treatment, and better prognostication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test–retest repeatability of myocardial oxidative metabolism and efficiency using standalone dynamic {sup 11}C-acetate PET and multimodality approaches in healthy controls

Background: Myocardial efficiency measured by {sup 11}C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. Methods and Results: Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using {sup 11}C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEE{sub CMR}, MEE{sub Echo}, and MEE{sub PET} values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P < .001. WMI{sub CMR}, WMI{sub Echo}, and WMI{sub PET} values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m{sup 2} × 10{sup 6}, respectively, P = .45. Repeatability for MEE{sub CMR} was superior compared with MEE{sub Echo} but did not differ significantly compared with MEE{sub PET} (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMI{sub CMR}, WMI{sub Echo}, and WMI{sub PET} were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). Conclusions: Non-invasive measurements of MEE using {sup 11}C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Machine Learning and Deep Learning for View Identification from Cardiac Magnetic Resonance Images

Background: Artificial intelligence is increasingly utilized to aid in the interpretation of cardiac magnetic resonance (CMR) studies. One of the first steps is the identification of the imaging plane depicted, which can be achieved by both deep learning (DL) and classical machine learning (ML) techniques without user input. We aimed to compare the accuracy of ML and DL for CMR view classification and to identify potential pitfalls during training and testing of the algorithms. Methods: To train our DL and ML algorithms, we first established datasets by retrospectively selecting 200 CMR cases. The models were trained using two different cohorts (passively and actively curated) and applied data augmentation to enhance training. Once trained, the models were validated on an external dataset, consisting of 20 cases acquired at another center. We then compared accuracy metrics and applied class activation mapping (CAM) to visualize DL model performance. Results: The DL and ML models trained with the passively-curated CMR cohort were 99.1% and 99.3% accurate on the validation set, respectively. However, when tested on the CMR cases with complex anatomy, both models performed poorly. After training and testing our models again on all 200 cases (active cohort), validation on the external dataset resulted in 95% and 90% accuracy, respectively. The CAM analysis depicted heat maps that demonstrated the importance of carefully curating the datasets to be used for training. Conclusions: Both DL and ML models can accurately classify CMR images, but DL outperformed ML when classifying images with complex heart anatomy.

artificial intelligence↗

RECONNECTION-DRIVEN DOUBLE LAYERS IN THE STRATIFIED PLASMA OF THE SOLAR TRANSITION REGION: SUPPLY OF HOT PLASMA INTO THE CORONA

A novel mechanism for the supply of hot plasma into the corona from the chromosphere is suggested here; the mechanism involves collisionless magnetic reconnection (CMR) in the transition region (TR) followed by double layer (DL) formation in the enhanced expansion of the chromospheric cold plasma mixed with CMR-heated hot electrons. It is well known that (i) the CMR produces energetic electrons and (ii) DLs naturally form in expanding dense plasmas containing a minor population of hot electrons. We apply these plasma physics facts to the dynamics of stratified plasma in the TR. In the TR where densities fall below ∼10{sup 16} m{sup −3}, all collisional mean-free paths, electron–ion, ion–neutral, and electron–neutral, become long enough to render plasma collisionless at kinetic scale lengths, making CMR and DL formation possible. The DLs accelerate the chromospheric cold ions to energies comparable to the energy of the hot electrons. When the upflowing energized ions neutralized by the escaping hot electrons thermalize, the resulting hot tenuous plasma supplies an energy flux ∼3 × 10{sup 5} erg cm{sup −2} s{sup −1} = 3 × 10{sup 2} J m{sup −2} s{sup −1} into the corona. The CMR–DL mechanism introduces sudden transitions in the TR as microstructures in both density and energy. The global transition in the TR could be a fractal structure containing such microscopic features. If not impossible, it is difficult to measure such microstructures, but it seems that the coronal heating begins in the nearly collisionless TR by CMR and DL formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis and Review of NASA Earth Science Metadata: How Automation Plays a Role

The Analysis and Review of the Common Metadata Repository (CMR ARC) Team reviews all EOSDIS metadata. The team’s objective is to achieve consistency, correctness, and completeness for all metadata records in the CMR, as well as improve the discoverability of NASA's Earth Science data within the CMR framework. This work is currently being completed at Marshall Space Flight Center. CMR makes a single discovery point possible for NASA's Earth Science data users. The CMR team, in collaboration with three other core metadata teams, contributes to the stewardship of NASA's Earth Science data through a process of continual curation and the ongoing development of the Unified Metadata Model (UMM). A key tool now used in the curation process, referred to as the NASA CMR Dashboard, is an online curation dashboard developed in collaboration with software development company, Element 84. This tool facilitates the review of Earth Science metadata records and subsequent stakeholder collaboration on the resolution of identified issues. A key capability of the new tool is a suite of automated compliance checks written in Python 3.6 that verify the integrity of various metadata elements across multiple standards.

Staton, Patrick↗