Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Combing Visible and Infrared Spectral Tests for Dust Identification

The MODIS Dark Target aerosol algorithm over Ocean (DT-O) uses spectral reflectance in the visible, near-IR and SWIR wavelengths to determine aerosol optical depth (AOD) and Angstrom Exponent (AE). Even though DT-O does have "dust-like" models to choose from, dust is not identified a priori before inversion. The "dust-like" models are not true "dust models" as they are spherical and do not have enough absorption at short wavelengths, so retrieved AOD and AE for dusty regions tends to be biased. The inference of "dust" is based on postprocessing criteria for AOD and AE by users. Dust aerosol has known spectral signatures in the near-UV (Deep blue), visible, and thermal infrared (TIR) wavelength regions. Multiple dust detection algorithms have been developed over the years with varying detection capabilities. Here, we test a few of these dust detection algorithms, to determine whether they can be useful to help inform the choices made by the DT-O algorithm. We evaluate the following methods: The multichannel imager (MCI) algorithm uses spectral threshold tests in (0.47, 0.64, 0.86, 1.38, 2.26, 3.9, 11.0, 12.0 micrometer) channels and spatial uniformity test [Zhao et al., 2010]. The NOAA dust aerosol index (DAI) uses spectral contrast in the blue channels (412nm and 440nm) [Ciren and Kundragunta, 2014]. The MCI is already included as tests within the "Wisconsin" (MOD35) Cloud mask algorithm.

aerosol optical depth↗

Multiple inductive signals are involved in the development of the ctenophore Mnemiopsis leidyi

Ctenophores possess eight longitudinally arrayed rows of comb plate cilia. Previous intracellular cell lineage analysis has shown that these comb rows are derived from two embryonic lineages, both daughters of the four e(1) micromeres (e(11) and e(12)) and a single daughter of the four m(1) micromeres (the m(12) micromeres). Although isolated e(1) micromeres will spontaneously generate comb plates, cell deletion experiments have shown that no comb plates appear during embryogenesis following the removal of e(1) descendents. Thus, the m(1) lineage requires the inductive interaction of the e(1) lineage to contribute to comb plate formation. Here we show that, although m(12) cells are normally the only m(1) derivatives to contribute to comb plate formation, m(11) cells are capable of generating comb plates in the absence m(12) cells. The reason that m(11) cells do not normally make comb rows may be attributable either to their more remote location relative to critical signaling centers (e.g., e(1) descendants) or to inhibitory signals that may be provided by other nearby cells such as sister cells m(12). In addition, we show that the signals provided by the e(1) lineage are not sufficient for m(1)-derived comb plate formation. Signals provided by endomesodermal progeny of either the E or the M lineages (the 3E or 2M macromeres) are also required. Copyright 2001 Academic Press.

NASA Discipline Evolutionary Biology↗

Tamper-Resistant Secure Disposal Container

Closure device for secure waste containers prevents classified papers and other proprietary articles from being withdrawn when container turned on side. Has pendulum that swings comb into closed position when container turned on side. Suspended with axis of rotation perpendicular to axes of combs. Extends through D-shaped cam ring, attached to upper comb with standoff struts. When container tilted sideways, pendulum swings along arc side of D-shaped ring. Forces cam ring aside, moving upper comb toward closed position. If container tilted forward or backward, pendulum does not interfere with comb movement. Spring catches added to combs so if actuated and close container opening, they lock in place to prevent further tampering.

Collins, Earl R., Jr.↗

Independent gain and bandwidth control of a traveling wave maser

An X-band traveling wave maser of the folded-comb type is presented, with two figure-eight coils for gain and bandwidth control. One figure-eight coil covers the full lengths of the comb structure for bandwidth adjustment of an external magnetic field. The other coil covers a central half of the comb structure for independent gain adjustment of the external magnetic field. The half of each figure-eight coil at the turn around end of the comb structure is oriented to aid the external magnetic field, and the half of each coil at the input-output end of the comb structure is oriented to buck the external magnetic field. The maser is pumped in the push-push mode with two different frequencies.

Trowbridge, D. L.↗

Test Structures For Bumpy Integrated Circuits

Cross-bridge resistors added to comb and serpentine patterns. Improved combination of test structures built into integrated circuit used to evaluate design rules, fabrication processes, and quality of interconnections. Consist of meshing serpentines and combs, and cross bridge. Structures used to make electrical measurements revealing defects in design or fabrication. Combination of test structures includes three comb arrays, two serpentine arrays, and cross bridge. Made of aluminum or polycrystalline silicon, depending on material in integrated-circuit layers evaluated. Aluminum combs and serpentine arrays deposited over steps made by polycrystalline silicon and diffusion layers, while polycrystalline silicon versions of these structures used to cross over steps made by thick oxide layer.

Buehler, Martin G.↗