Performance of 24-inch supersonic axial-flow compressor in air II : performance of compressor rotor at equivalent tip speeds from 800 to 1765 feet per second
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An experimental investigation of a highly loaded two-stage turbine with a downstream stator revealed that (1) at equivalent design work and speed the brake internal efficiency was 0.81 and the maximum efficiency obtained was 0.85, and (2) the downstream stator left very little energy in the form of tangential velocity in the gas and, in general, performed well with 0.78 recovery being obtained at equivalent design work and speed.
Explore the source record for details and available documents.
The brake internal efficiency of the highly loaded two-stage turbine was 0.79 equivalent design work and speed. The maximum brake internal efficiency was 0.84. A radial survey revealed these major defects: (1) the first-rotor throat area was too large, and a large area of underturned flow existed near the tip;(2) considerable underturning existed at the second-stator outlet; and (3) tangential components of velocity at the turbine outlet amounted to 2.5 points in turbine efficiency.
Modifying the original turbine by closing down the first-rotor throat area and shrouding the first and second rotors resulted in an over-all increase in in efficiency of 3.5 percentage points. At equivalent design work and speed the rating and aerodynamic efficiences of the modified turbine were 0.825 and 0.846, respectively. The maximum rating and erodynamic efficiencies were 0.875 and 0.906, respectively. A radial survey indicated improved firstively. A radial survey indicated improved first and second-stage efficiencies but showed that the effective throat areas of the second stator and rotor were too large.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Investigations were conducted in the Cleveland altitude wind tunnel to determine the performance and operational characteristics of the 19B-2, 19B-8, and 19XS-1 turbojet engines. One objective was to determine the effect of altitude, flight Mach number, and tail-pipe-nozzle area on the performance characteristics of the six-stage and ten-stage axial-flow compressors of the 19B-8 and 19XB-1 engines, respectively, The data were obtained over a range of simulated altitudes and flight Mach numbers. At each simulated flight condition the engine was run over its full operable range of speeds. Performance characteristics of the 19B-8 and 19XB-1 compressors for the range of operation obtainable in the turboJet-engine installation are presented. Compressor characteristics are presented as functions of air flow corrected to sea-level conditions, compressor Mach number, and compressor load coefficient. For the range of compressor operation investigated, changes in Reynolds number had no measurable effect on the relations among compressor Mach number, corrected air flow, compressor load coefficient, compressor pressure ratio, and compressor efficiency. The operating lines for the 19B-8 compressor lay on the low-air-flow side of the region of maximum compressor efficiency; the 19B-8 compressor operated at higher average pressure coefficients per stage and produced a lower over-all pressure ratio than did the 19XB-1 compressor.
Calculations of the onset of flow instability are carried out for low-speed multistage axial compressors operating with asymmetric inlet flow. The modeling of the fluid dynamic interaction between the spoiled and unspoiled sectors of the compressor is the most important feature of the calculation procedure. The calculations show that annulus average slope of the compressor pressure rise characteristic equal to zero is a useful approximate stability criterion for situations where the dynamics of the compressor flow field do not couple strongly to the compression system or the structure of the imposed distortion is not similar to that of the eigenmodes of the flow in the compressor annulus. This criterion is employed to investigate the relationship between the present model and the 'parallel compressor' model. Calculations are also presented for cases when compressor and compressor system are closely coupled, and situations in which the compressor is subjected to a rotating distortion. These first-of-a-kind computations, and the accompanying description of the physical mechanisms, show that the stability of the flow in the compressor can be adversely affected if the temporal or spatial structure of the distortion is such that resonant type responses can be evoked either from the compressor or from compressor/compression system interactions.
Aircraft compressors can suffer debilitating consequences as a result of rotating stall and surge events caused by inlet distortions. This is particularly true of aircraft during takeoff, when the compressor is operating at peak performance close to the surge line. Significant research has been conducted by the NASA Glenn Research Center in the area of compressor stability enhancement through active and passive control methods. Most recently, an experiment was conducted at the Wright Patterson Air Force Base Research Laboratory on a two-stage fan with inlet guide vanes and inlet distortion. In this joint Small Business Innovation Research effort between Scientific Systems and Glenn, control of rotating stall was demonstrated in a multistage transonic fan. This twostage fan with inlet guide vanes was tested under clean and distorted inlet conditions. The compressor was also configured with a circumferential distortion screen capable of 180 of distortion and with 14 high-velocity injectors upstream of the first rotor. Twelve of these injectors could oscillate up to frequencies of 450 Hz. The additional two injectors were located next to each other and were used in concert with each other as a single, on/off, high-authority actuator. In a first test of injection in this multistage environment, 12 of the valves were opened 50 percent of their full stroke to assess steady injection through the compressor. This baseline injection is shown in the compressor characteristic of the following figure, and stall margin improvements are tracked from this baseline condition. The compressor was then tested with clean inlet conditions using 12 injectors and active control. Pressure disturbances were tracked before rotating stall, and a constant gain control scheme reduced the stalling mass flow by 10.8 percent over the baseline. With the distortion screen present in the inlet, a pole-zero cancellation control scheme was used to achieve a 6.4-percent decrease in stalling mass flow. These improvements also are shown in the figure. In a final experiment, actively controlled, high-frequency injection from the 12 valves was used in conjunction with the high-authority actuators. In this test, the stalling mass flow of the compressor was reduced by 27 percent as indicated in the graph. These results were obtained by injecting less than 2 percent of the total compressor throughflow into the rotor tip region via 14 injection ports. These results mark the first successful demonstration of actively controlled air injection as a stall-control strategy for multistage compressors operating at speeds typical of an actual gas turbine engine. A goal of continuing research is to determine the combination of air-injection parameters and control strategies that are most effective in providing stall control for both clean and distorted inlet flow conditions for multistage environments. Other goals include the demonstration of stall control at many locations along the core compressor and development and application of active stall control strategies that will be integral flightworthy components of onboard engine hardware.
An investigation was conducted on a large centrifugal compressor from an experimental turbojet engine to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal-type compressors. The results of the research conducted on the compressor indicated that the compressor would not meet the desired engine-design air-flow requirements (78 lb/sec) because of an air-flow restriction in the vaned collector (diffuser). Revision of the vaned collector resulted in an increased air-flow capacity over the speed range and showed improved matching of the impeller and diffuser components. At maximum flow, the original compressor utilized approximately 90 percent of the available geometric throat area at the vaned-collector inlet and the revised compressor utilized approximately 94 percent, regardless of impeller speed. The ratio of the maximum weight flows of the revised and original compressors were less than the ratio of effective critical throat areas of the two compressors because of the large pressure losses in the impeller near the impeller inelt and the difference increased with an increase in impeller speed. In order to further increase the pressure ratio and maximum weight flow of the compressor, the impeller must be modified to eliminate the pressure losses therein.