Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONFLICTS OF INTEREST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Science for Society Workshop Summary Report

Science for Society, a workshop held at the Oak Ridge National Laboratory (ORNL) on September 27, 20111, explored ways to move Laboratory science toward use. It sought actionable recommendations. Thus the workshop focused on: (1) current practices that promote and inhibit the translation of science into use, (2) principles that could lead to improving ORNL's translational knowledge and technology transfer efforts, and (3) specific recommendations for making these principles operational. This highly interactive workshop struck a positive chord with participants, a group of 26 ORNL staff members from diverse arenas of science and technology (S and T), technology transfer, and external laboratory relations, who represented all levels of science, technology, and management. Recognizing that the transformation of fundamental principles into operational practices often follows a jagged path, the workshop sought to identify key choices that could lead to a smoother journey along this path, as well as choices that created roadblocks and bottlenecks. The workshop emphasized a portion of this pathway, largely excluding the marketplace. Participants noted that research translation includes linkages between fundamental and applied research and development (R and D), and is not restricted to uptake by manufacturers, consumers, or end users. Three crosscutting ideas encapsulate workshop participants observations: (1) ORNL should take more action to usher the translation of its S and T products toward use, so as to make a positive national and global impact and to enhance its own competitiveness in the future; (2) ORNL (and external entities such as DOE and Congress) conveys inconsistent messages with regard to the importance of research translation and application, which (a) creates confusion, (b) poses disincentives to pursue research translation, (c) imposes barriers that inhibit cross-fertilization and collaboration, and (d) diminishes the effectiveness of both the science mission and the translation of that science for use; and (3) ORNL should design its commitments and actions for helping move science from the Laboratory toward use to align with one another and should integrate them into its institutional culture in such a way as to elevate research translation and application to coequal status with scientific excellence. Participants made several actionable recommendations for enhancing research translation at ORNL, some of which were particular to specific S and T domains. Among the recommendations that participants agreed apply Lab-wide are to: align metrics and incentives with research translation goals; manage risks and conflicts of interest instead of avoiding them; and create programs (e.g., entrepreneurial leave) that promote interactions between key ORNL staff and industry in ways that complement careers at ORNL.

42 ENGINEERING↗

Financial Relationships With Industry of Editorial Board Members of the Three Journals of the American Society for Radiation Oncology

Purpose: To quantitate financial conflicts of interest (FCOIs) among radiation oncology peer-reviewers, specifically editorial board members of the 3 American Society for Radiation Oncology journals. Methods and Materials: The public Centers for Medicare and Medicaid Services Open Payments database delineates payments in 3 categories (general payments, research funding, and company ownership). After excluding non-US and non-MDs, names of board members were searched. Values of each FCOI were extracted for 2013 to 2015 and compiled. Results: Of 85 board members, 65 (76%) received any form of payment during the overall period. The majority of delivered payments were general payments: 59 (69%) received at least 1 general payment during these 3 years. In each year, 9 board members (11%) received research funding, and 3 board members (4%) reported company ownership. Over the studied period, all board members received a sum total of $5,387,985; this was composed of $665,801 (12%) in general payments, $3,758,968 (70%) in research funding, and $963,216 (18%) in company ownership. The mean general payment and research funding amounts (all members) were $2,621 and $14,741, respectively. Median (interquartile range) general payments and research funding only in board members receiving payments were $419 ($91-$5072) and $56,250 ($13,345-$200,000), respectively. When assessing general payments according to amount, the vast majority of editorial board members received lower-quantity or no such payments, along with a smaller proportion that received higher-volume payments. The most frequent sources of general payments were Varian, Elekta, and Bristol-Myers Squibb. Merck and Varian were the most frequent funding sources for research payments. Conclusions: In this population, the majority of FCOIs were general payments, but research funding comprised the highest monetary sums. Large-volume FCOIs do not apply to the vast majority of editorial board members, implying that the maintained integrity of academic peer-review is likely not influenced to a large extent by FCOIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Putting SEA in context: A discourse perspective on how SEA contributes to decision-making

Over the last couple of years there is an ongoing debate in the environmental assessment literature about the contribution of Strategic Environmental Assessment (SEA) to public decision-making and how this can be understood and enhanced by better incorporating insights from policy analysis, planning theory and political sciences. By explicitly framing SEA as an element in a process where stakeholders with diverging interests struggle, acceptability of SEA processes and results by stakeholders has become an important element in SEA evaluation. In addition, the importance of other context variables, such as the institutional organisation, and the need for SEA to adapt to this context, is stressed. Thus far, publications in this area have been dealing with the operationalisation of SEA's 'contribution', typologies of roles that SEA can or should play in different policy settings and on factors that stimulate or impede SEA to play these roles. In this paper an alternative approach is suggested that starts from the deliberative processes around a particular policy issue or decision supported by SEA. Of particular interest are 'discourses': the frames through which groups of actors give meaning to aspects of the policy issues and decisions that are supported by SEA. Discourses do not only reflect conflicts of interests and power play, but also the ways in which actors perceive and understand aspects of the world. Decision-making is conceptualised as a 'system of competing discourse coalitions and their struggles to 'control shared meanings' and to gain acceptance of their framing of a policy issue' [Durning D. A review of Fischer and Forrester (1993) The argumentative turn in policy analysis and planning. Policy Sci 1995;28(1):102-8]. SEA is one of the events in this process that may impact upon dominant discourses. Discourse analysis allows for an understanding of arguments that are considered legitimate for (not) incorporating particular elements of SEA. In addition it opens the door to relatively new strategies for SEA professionals to enhance their contribution to decision-making.

54 ENVIRONMENTAL SCIENCES↗

Describing patterns of familial cancer risk in subfertile men using population pedigree data

STUDY QUESTION Can we simultaneously assess risk for multiple cancers to identify familial multicancer patterns in families of azoospermic and severely oligozoospermic men? SUMMARY ANSWER Here, distinct familial cancer patterns were observed in the azoospermia and severe oligozoospermia cohorts, suggesting heterogeneity in familial cancer risk by both type of subfertility and within subfertility type. WHAT IS KNOWN ALREADY Subfertile men and their relatives show increased risk for certain cancers including testicular, thyroid, and pediatric. STUDY DESIGN, SIZE, DURATION A retrospective cohort of subfertile men (N = 786) was identified and matched to fertile population controls (N = 5674). Family members out to third-degree relatives were identified for both subfertile men and fertile population controls (N = 337 754). The study period was 1966–2017. Individuals were censored at death or loss to follow-up, loss to follow-up occurred if they left Utah during the study period. PARTICIPANTS/MATERIALS, SETTING, METHODS Azoospermic (0 × 10 6 /mL) and severely oligozoospermic (<1.5 × 10 6 /mL) men were identified in the Subfertility Health and Assisted Reproduction and the Environment cohort (SHARE). Subfertile men were age- and sex-matched 5:1 to fertile population controls and family members out to third-degree relatives were identified using the Utah Population Database (UPDB). Cancer diagnoses were identified through the Utah Cancer Registry. Families containing ≥10 members with ≥1 year of follow-up 1966–2017 were included (azoospermic: N = 426 families, 21 361 individuals; oligozoospermic: N = 360 families, 18 818 individuals). Unsupervised clustering based on standardized incidence ratios for 34 cancer phenotypes in the families was used to identify familial multicancer patterns; azoospermia and severe oligospermia families were assessed separately. MAIN RESULTS AND THE ROLE OF CHANCE Compared to control families, significant increases in cancer risks were observed in the azoospermia cohort for five cancer types: bone and joint cancers hazard ratio (HR) = 2.56 (95% CI = 1.48–4.42), soft tissue cancers HR = 1.56 (95% CI = 1.01–2.39), uterine cancers HR = 1.27 (95% CI = 1.03–1.56), Hodgkin lymphomas HR = 1.60 (95% CI = 1.07–2.39), and thyroid cancer HR = 1.54 (95% CI = 1.21–1.97). Among severe oligozoospermia families, increased risk was seen for three cancer types: colon cancer HR = 1.16 (95% CI = 1.01–1.32), bone and joint cancers HR = 2.43 (95% CI = 1.30–4.54), and testis cancer HR = 2.34 (95% CI = 1.60–3.42) along with a significant decrease in esophageal cancer risk HR = 0.39 (95% CI = 0.16–0.97). Thirteen clusters of familial multicancer patterns were identified in families of azoospermic men, 66% of families in the azoospermia cohort showed population-level cancer risks, however, the remaining 12 clusters showed elevated risk for 2-7 cancer types. Several of the clusters with elevated cancer risks also showed increased odds of cancer diagnoses at young ages with six clusters showing increased odds of adolescent and young adult (AYA) diagnosis [odds ratio (OR) = 1.96–2.88] and two clusters showing increased odds of pediatric cancer diagnosis (OR = 3.64–12.63). Within the severe oligozoospermia cohort, 12 distinct familial multicancer clusters were identified. All 12 clusters showed elevated risk for 1–3 cancer types. An increase in odds of cancer diagnoses at young ages was also seen in five of the severe oligozoospermia familial multicancer clusters, three clusters showed increased odds of AYA diagnosis (OR = 2.19–2.78) with an additional two clusters showing increased odds of a pediatric diagnosis (OR = 3.84–9.32). LIMITATIONS, REASONS FOR CAUTION Although this study has many strengths, including population data for family structure, cancer diagnoses and subfertility, there are limitations. First, semen measures are not available for the sample of fertile men. Second, there is no information on medical comorbidities or lifestyle risk factors such as smoking status, BMI, or environmental exposures. Third, all of the subfertile men included in this study were seen at a fertility clinic for evaluation. These men were therefore a subset of the overall population experiencing fertility problems and likely represent those with the socioeconomic means for evaluation by a physician. WIDER IMPLICATIONS OF THE FINDINGS This analysis leveraged unique population-level data resources, SHARE and the UPDB, to describe novel multicancer clusters among the families of azoospermic and severely oligozoospermic men. Distinct overall multicancer risk and familial multicancer patterns were observed in the azoospermia and severe oligozoospermia cohorts, suggesting heterogeneity in cancer risk by type of subfertility and within subfertility type. Describing families with similar cancer risk patterns provides a new avenue to increase homogeneity for focused gene discovery and environmental risk factor studies. Such discoveries will lead to more accurate risk predictions and improved counseling for patients and their families. STUDY FUNDING/COMPETING INTEREST(S) This work was funded by GEMS: Genomic approach to connecting Elevated germline Mutation rates with male infertility and Somatic health (Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD): R01 HD106112). The authors have no conflicts of interest relevant to this work.

60 APPLIED LIFE SCIENCES↗

SU-F-E-10: Student-Driven Exploration of Radiographic Material Properties, Phantom Construction, and Clinical Workflows Or: The Extraordinary Life of CANDY MAN

Purpose: To develop a hands-on learning experience that explores the radiological and structural properties of everyday items and applies this knowledge to design a simple phantom for radiotherapy exercises. Methods: Students were asked to compile a list of readily available materials thought to have radiation attenuation properties similar to tissues within the human torso. Participants scanned samples of suggested materials and regions of interest (ROIs) were used to characterize bulk attenuation properties. Properties of each material were assessed via comparison to a Gammex Tissue characterization phantom and used to construct a list of inexpensive near-tissue-equivalent materials. Critical discussions focusing on samples found to differ from student expectations were used to revise and narrow the comprehensive list. From their newly acquired knowledge, students designed and constructed a simple thoracic phantom for use in a simulated clinical workflow. Students were tasked with setting up the phantom and acquiring planning CT images for use in treatment planning and dose delivery. Results: Under engineer and physicist supervision, students were trained to use a CT simulator and acquired images for approximately 60 different foodstuffs, candies, and household items. Through peer discussion, students gained valuable insights and were made to review preconceptions about radiographic material properties. From a subset of imaged materials, a simple phantom was successfully designed and constructed to represent a human thorax. Students received hands-on experience with clinical treatment workflows by learning how to perform CT simulation, create a treatment plan for an embedded tumor, align the phantom for treatment, and deliver a treatment fraction. Conclusion: In this activity, students demonstrated their ability to reason through the radiographic material selection process, construct a simple phantom to specifications, and exercise their knowledge of clinical workflows. Furthermore, the enjoyable and inexpensive nature of this project proved to attract participant interest and drive creative exploration. Mahon and Riblett have nothing to disclose; Hugo has a research agreement with Phillips Medical systems, a license agreement with Varian Medical Systems, research grants from the National Institute of Health. Authors do not have any potential conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

How to Handle the Conflict between Safety and Security - 18564

The purpose of safety and security for nuclear activities are the same. They are both necessary measures to protect people and the environment from radioactive material. There are many measures that enhance both the safety and the security but there are also measures serving one area that are in direct conflict with the other. How information is handled is maybe the best example to demonstrate this conflict between interests. In the security field, information is handled on a need-to-know basis, preventing valuable details to fall into hands of antagonists, terrorists etc. The safety culture, on the contrary, is based on knowledge and transparency and it encourages the sharing of information and experience to improve the safety. There is little guidance on how to manage the conflicts between safety and security for a transport system moving nuclear fuel and radioactive waste and especially when there are conflicts between different legislation areas, for example the Act on Nuclear Activities and Safety of Life at Sea. The Swedish Nuclear Fuel and Waste Management Co, SKB, transports all Swedish spent fuel and operational waste from the Nuclear Power Plants to the central storage facilities in Sweden. To manage the transport system, SKB owns a fleet of packages, road vehicles and an INF 3 ship. For the shipments of nuclear material, the security focus has increased rapidly over the years after the 9/11 attack, followed by regulatory requirements on enhanced security. SKB is currently running a project to further strengthen the transport security, an activity that requires a careful balance between safety and security. This paper describes the methods used and the challenges experienced trying to manage the conflicts between safety and security for the Swedish nuclear transport system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-FG-BRA-10: Radiodosimetry of a Novel Alpha Particle Therapy Targeted to Uveal Melanoma: Absorbed Dose to Organs in Mice

Purpose: The melanocortin-1 receptor (MC1R) is expressed in 94% of uveal melanomas and is described as an ideal target for this untreatable disease. MC1RL is a high affinity MC1R specific peptidomimetic ligand that can serve as a scaffold for therapeutic conjugates such as alpha particle emitting isotopes. The purpose of this study was to assess normal tissue distribution and risk as a result of using the DOTA chelator conjugated to MC1RL to deliver {sup 225}Ac: MC1RL-DOTA-{sup 225}Ac. Methods: 17 non-tumor bearing BALB/c mice were intravenously injected with the novel MC1RL-DOTA-{sup 225}Ac radiopharmaceutical with an average initial administered activity of 2.5 µCi. After the injection, three groups of animals (6, 6, and 5 per group) were euthanized at 24, 48, and 96 hour time points. A total of 11 organs of interest were harvested at each time point including kidneys and liver. Since the emitted alpha particles from {sup 225}Ac and its daughter products are not easy to detect directly, the isomeric gamma spectra were measured instead in the tissue samples using a modified Atomlab™ Gamma Counter (Biodex Medical Systems, Inc) and converted using factors for gamma ray abundance per alpha decay. Dosimetry was performed using measured radioactivity distribution in organs and the generalized internal dosimetry schema of MIRD pamphlet #21. Results: Our calculations have shown that the maximum absorbed dose was delivered to the liver with a total of 47 cGy per 96 hour period. The average dose per kidney was calculated to be 21 cGy. Heart, brain, lung, spleen, skin doses ranged from 0.01 to 1 cGy over the same time period. All animals gained weight over the 110 day decay period and no organ damage was observed by pathology. Conclusion: Based on our results, the risk of using the MC1RL-DOTA-{sup 225}Ac compound is relatively small in terms of deterministic radiation effects. Funding Support: NIH/NCI P50CA168536-03 Skin SPORE; NIH/NCI Phase I SBIR Contract #HHSN261201500067C; Imaging and Technology Center of Excellence at Moffitt. Disclosures and Conflict of Interest: Collaboration with Modulation Therapeutics, Inc.(MTI) and has been partially funded by sub-contracts from MTI via collaboration on a NIH/NCI phase I SBIR contract.

60 APPLIED LIFE SCIENCES↗

A Surgeon's View on Endarterectomy and Stenting in 2011: Lest We Forget, It's All About Preventing Stroke

It has been nearly 60 years since Felix Eastcott published his seminal paper on carotid reconstruction, which paved the way for carotid endarterectomy (CEA) and then carotid artery stenting (CAS) to assume prominent roles in the prevention of stroke. Yet the ensuing 60 years has witnessed repeated cycles of challenges to practice, professional mistrust, conflicts of interest, dogmatic retention of traditional management strategies, inappropriate corporate interventions, and a general failure to adapt to new evidence. Even the performance of large-scale randomised trials has been associated with rancour and a lack of consensus. This article reviews the history of invasive interventions in the treatment of carotid disease and makes a plea to both the surgical and interventional communities that the fundamental priority must always be the prevention of stroke. It concludes with an appeal for colleagues to collaborate to determine how best to treat patients during the hyperacute period after the onset of symptoms and to identify a smaller cohort of asymptomatic patients who are truly at high risk for stroke in whom to target CAS or CEA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Antibiotics-induced gut microbiota dysbiosis promotes tumor initiation via affecting APC-Th1 development in mice

Gut microbiota is critical for maintaining body immune homeostasis and thus affects tumor growth and therapeutic efficiency. Here, we investigated the link between microbiota and tumorgenesis in a mice model of subcutaneous melanoma cell transplantation, and explored the underlying mechanism. We found disruption of gut microbiota by pretreating mice with antibiotics promote tumor growth and remodeling the immune compartment within the primary tumor. Indeed, gut microbial dysbiosis reduced the infiltrated mature antigen-presenting cells of tumor, together with lower levels of co-stimulators, such as CD80, CD86 and MHCII, as well as defective Th1 cytokines, including IFNγ, TNFα, IL12p40, and IL12p35. Meantime, splenic APCs displayed blunted ability in triggering T cell proliferation and IFNγ secretion. However, oral administration of LPS restored the immune surveillance effects and thus inhibited tumor growth in the antibiotics induced gut microbiota dysbiosis group. Taken together, these data highly supported that antibiotics induced gut microbiota dysbiosis promotes tumor initiation, while LPS supplementation would restore the effective immune surveillance and repress tumor initiation. - Highlights: • Antibiotics induced gut microbiota dysbiosis promotes tumor initiation in mice. • Gut microbiota disruption compromise APC-Th1 development in tumor. • Orally LPS administration rescues tumor immune surveillance in gut microbiota disrupted mice. • None of the authors have any conflict of interest.

60 APPLIED LIFE SCIENCES↗

Evaluation of Health Economics in Radiation Oncology: A Systematic Review

Purpose: Despite the rising costs in radiation oncology, the impact of health economics research on radiation therapy practice analysis patterns is unclear. We performed a systematic review of cost-effectiveness analyses (CEAs) and cost-utility analyses (CUAs) to identify trends in reporting quality in the radiation oncology literature over time. Methods and Materials: A systematic review of radiation oncology economic evaluations up to 2014 was performed, using MEDLINE and EMBASE databases. The Consolidated Health Economic Evaluation Reporting Standards guideline informed data abstraction variables including study demographics, economic parameters, and methodological details. Tufts Medical Center CEA registry quality scores provided a basis for qualitative assessment of included studies. Studies were stratified by 3 time periods (1995-2004, 2005-2009, and 2010-2014). The Cochran-Armitage trend test and linear trend test were used to identify trends over time. Results: In total, 102 articles were selected for final review. Most studies were in the context of a model (61%) or clinical trial (28%). Many studies lacked a conflict of interest (COI) statement (67%), a sponsorship statement (48%), a reported study time horizon (35%), and the use of discounting (29%). There was a significant increase over time in the reporting of a COI statement (P<.001), health care payer perspective (P=.019), sensitivity analyses using multivariate (P=.043) or probabilistic methods (P=.011), incremental cost-effectiveness threshold (P<.001), secondary source utility weights (P=.010), and cost effectiveness acceptability curves (P=.049). There was a trend toward improvement in Tuft scores over time (P=.065). Conclusions: Recent reports demonstrate improved reporting rates in economic evaluations; however, there remains significant room for improvement as reporting rates are still suboptimal. As fiscal pressures rise, we will rely on economic assessments to guide our practice decisions and policies. We recommend improved adherence to published guidelines and further research to determine the clinical implications of our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Industry Funding Among Leadership in Medical Oncology and Radiation Oncology in 2015

Purpose: To quantify and determine the relationship between oncology departmental/division heads and private industry vis-à-vis potential financial conflict of interests (FCOIs) as publicly reported by the Centers for Medicare and Medicaid Services Open Payments database. Methods and Materials: We extracted the names of the chairs/chiefs in medical oncology (MO) and chairs of radiation oncology (RO) for 81 different institutions with both RO and MO training programs as reported by the Association of American Medical Colleges. For each leader, the amount of consulting fees and research payments received in 2015 was determined. Logistic modeling was used to assess associations between the 2 endpoints of receiving a consulting fee and receiving a research payment with various institution-specific and practitioner-specific variables included as covariates: specialty, sex, National Cancer Institute designation, PhD status, and geographic region. Results: The majority of leaders in MO were reported to have received consulting fees or research payments (69.5%) compared with a minority of RO chairs (27.2%). Among those receiving payments, the average (range) consulting fee was $13,413 ($200-$70,423) for MO leaders and $6463 ($837-$16,205) for RO chairs; the average research payment for MO leaders receiving payments was $240,446 ($156-$1,234,762) and $295,089 ($160-$1,219,564) for RO chairs. On multivariable regression when the endpoint was receipt of a research payment, those receiving a consulting fee (odds ratio [OR]: 5.34; 95% confidence interval [CI]: 2.22-13.65) and MO leaders (OR: 5.54; 95% CI: 2.62-12.18) were more likely to receive research payments. Examination of the receipt of consulting fees as the endpoint showed that those receiving a research payment (OR: 5.41; 95% CI: 2.23-13.99) and MO leaders (OR: 3.06; 95% CI: 1.21-8.13) were more likely to receive a consulting fee. Conclusion: Leaders in academic oncology receive consulting or research payments from industry. Relationships between oncology leaders and industry can be beneficial, but guidance is needed to develop consistent institutional policies to manage FCOIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Research Ethics: Considerations for the Radiation Oncologist

Consideration of clinical research ethics in radiation oncology is underexplored relative to other areas of oncology. A number of ethical challenges related to informed consent, randomization, conflicts of interest, and scientific validity and social value are shared with other areas of medicine, although their exact inflections are specific to radiation oncology. In addition, there are unique concerns in radiation oncology arising from the rapid evolution and uneven distribution of radiation technologies; the greater unfamiliarity of the general public and research oversight committees in regard to radiation oncology clinical practice; and the high complexity of managing most radiation oncology research, much of which is carried out in high-acuity multidisciplinary oncologic settings. To produce the best research, adherence to the highest ethical standards should be pursued as an integral component of all radiation oncology research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analyzing Wildland Fire Smoke Emissions Data Using Compositional Data Techniques

By conservation of mass, the mass of wildland fuel that is pyrolyzed and combusted must equal the mass of smoke emissions, residual char and ash. For a given set of conditions, these amounts are fixed. This places a constraint on smoke emissions data which violates statistical assumptions for many of the methods currently used to analyze these data such as linear regression, analysis of variance, and t-tests. These data are inherently multivariate and non-negative parts of a whole. This paper introduces the field of compositional data analysis to the emissions community and provides examples of appropriate statistical treatment of emissions data. It is shown that modified combustion efficiency should not be used as a predictor variable for other smoke emissions because it is not an independent variable. An alternative method based on compositional linear trends to estimate trace gas composition using CO and CO2 is presented. The data used in this paper resulted from projects the DOD/DOE/EPA Strategic 586 Environmental Research and Development Program projects RC-1648 and 1649. The senior 587 author appreciates the guidance and R scripts provided by Prof. Girty at San Diego State 588 University to estimate linear trends by perturbation. J. P.-A. was supported by the Spanish 589 Ministry of Science, Innovation and Universities under the project CODAMET (RTI2018-590 095518-B-C21, 2019-2021). The data used in this study have been previously published and are 591 available in the original publications. DRW conceived the initial manuscript (70 percent) and 592 performed the bulk of the data analysis. JPA provided statistical guidance and compositional data 593 expertise and contributed 20 percent of the manuscript. TJJ and HJ were extensively involved in 594 the study that provided the data. TJJ provide smoke emissions expertise and HJ provided 595 combustion expertise. The authors declare that they have no conflict of interest. The use of trade 596 or firm names in this publication is for reader information and does not imply endorsement by 597 the U.S. Department of Agriculture of any product or service.

simplex, compositional data analysis, balance, log↗

SU-D-18A-05: Assessing Elekta MLC Tracking Performance

Purpose: To investigate the technical feasibility of using Elekta MLCs in tracked radiotherapy, specifically to show the capability of an Agility MLC to follow model tumor trajectories using object tracking. The system performance of the MLC is to be assessed via dosimetric experiments and temporal response measures. Methods: The system observer in the tracking cascade consisted of a camera serving for this proof of concept; Images of a moving object were acquired continuously and decorrelated for the position information, which was fed forward to the RT computer controlling the MLC via an interface provided by Elekta. The 1D motion (in the direction of the leaves) was induced by a CIRS motion controller. Additionally, the aperture position was observed by means of the light field of the linac. Calculating the phase between aperture and object yielded the mean aperture lag for the current setup. The object was restricted to sinusoidal motion with a period of 10s. For dosimetry, GafChromic radiosensitive film was irradiated with a total dose of 1000MU using an aperture size of 40mm and a motion range of 30mm. Results: Object tracking can substantially reconstruct the geometric dose response of a static target. In the dynamic case, dose is smeared out into the legs of the static distribution, leading to a reduced plateau and increased FWHM of 5mm, compared to the static width of 38mm. The time-lag between object and aperture was determined to be approximately 300ms for the current set-up. Conclusion: We demonstrated a tracking experiment performed on a clinical Elekta linear accelator for the first time. Observed profile variations show the dosimetric impact of tracked delivery. The determined lag is a valuable descriptor for a future tracking cascade employing predictor filters. The performed experiments are generic and possible predecessors for future applications with MR-Linac or ultrasound probes. Conflict of interest: this project is partly funded by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest.

60 APPLIED LIFE SCIENCES↗

SU-E-T-254: Optimization of GATE and PHITS Monte Carlo Code Parameters for Uniform Scanning Proton Beam Based On Simulation with FLUKA General-Purpose Code

Purpose: Monte Carlo codes are becoming important tools for proton beam dosimetry. However, the relationships between the customizing parameters and percentage depth dose (PDD) of GATE and PHITS codes have not been reported which are studied for PDD and proton range compared to the FLUKA code and the experimental data. Methods: The beam delivery system of the Indiana University Health Proton Therapy Center was modeled for the uniform scanning beam in FLUKA and transferred identically into GATE and PHITS. This computational model was built from the blue print and validated with the commissioning data. Three parameters evaluated are the maximum step size, cut off energy and physical and transport model. The dependence of the PDDs on the customizing parameters was compared with the published results of previous studies. Results: The optimal parameters for the simulation of the whole beam delivery system were defined by referring to the calculation results obtained with each parameter. Although the PDDs from FLUKA and the experimental data show a good agreement, those of GATE and PHITS obtained with our optimal parameters show a minor discrepancy. The measured proton range R90 was 269.37 mm, compared to the calculated range of 269.63 mm, 268.96 mm, and 270.85 mm with FLUKA, GATE and PHITS, respectively. Conclusion: We evaluated the dependence of the results for PDDs obtained with GATE and PHITS Monte Carlo generalpurpose codes on the customizing parameters by using the whole computational model of the treatment nozzle. The optimal parameters for the simulation were then defined by referring to the calculation results. The physical model, particle transport mechanics and the different geometrybased descriptions need accurate customization in three simulation codes to agree with experimental data for artifact-free Monte Carlo simulation. This study was supported by Grants-in Aid for Cancer Research (H22-3rd Term Cancer Control-General-043) from the Ministry of Health, Labor and Welfare of Japan, Grants-in-Aid for Scientific Research (No. 23791419), and JSPS Core-to-Core program (No. 23003). The authors have no conflict of interest.

60 APPLIED LIFE SCIENCES↗

WE-E-BRE-04: Dual Focal Spot Dose Painting for Precision Preclinical Radiobiological Investigations

Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mm circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations. Funding Support: this work is supported by funding the National Sciences and Engineering Research Council of Canada, and a Mitacs-accelerate fellowship. Conflict of Interest: Dr. Lindsay and Dr. Jaffray are listed as inventors of the small animal microirradiator described herein. This system has been licensed for commercial development.

60 APPLIED LIFE SCIENCES↗

SU-C-17A-03: Evaluation of Deformable Image Registration Methods Between MRI and CT for Prostate Cancer Radiotherapy

Purpose: We evaluated the performance of two commercially available and one open source B-Spline deformable image registration (DIR) algorithms between T2-weighted MRI and treatment planning CT using the DICE indices. Methods: CT simulation (CT-SIM) and MR simulation (MR-SIM) for four prostate cancer patients were conducted on the same day using the same setup and immobilization devices. CT images (120 kVp, 500 mAs, voxel size = 1.1x1.1x3.0 mm3) were acquired using an open-bore CT scanner. T2-weighted Turbo Spine Echo (T2W-TSE) images (TE/TR/α = 80/4560 ms/90°, voxel size = 0.7×0.7×2.5 mm3) were scanned on a 1.0T high field open MR-SIM. Prostates, seminal vesicles, rectum and bladders were delineated on both T2W-TSE and CT images by the attending physician. T2W-TSE images were registered to CT images using three DIR algorithms, SmartAdapt (Varian), Velocity AI (Velocity) and Elastix (Klein et al 2010) and contours were propagated. DIR results were evaluated quantitatively or qualitatively by image comparison and calculating organ DICE indices. Results: Significant differences in the contours of prostate and seminal vesicles were observed between MR and CT. On average, volume changes of the propagated contours were 5%, 2%, 160% and 8% for the prostate, seminal vesicles, bladder and rectum respectively. Corresponding mean DICE indices were 0.7, 0.5, 0.8, and 0.7. The intraclass correlation coefficient (ICC) was 0.9 among three algorithms for the Dice indices. Conclusion: Three DIR algorithms for CT/MR registration yielded similar results for organ propagation. Due to the different soft tissue contrasts between MRI and CT, organ delineation of prostate and SVs varied significantly, thus efforts to develop other DIR evaluation metrics are warranted. Conflict of interest: Submitting institution has research agreements with Varian Medical System and Philips Healthcare.

60 APPLIED LIFE SCIENCES↗