Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Clinical and echocardiographic characteristics of papillary fibroelastomas: a retrospective and prospective study in 162 patients

BACKGROUND: Cardiac papillary fibroelastoma (CPF) is a primary cardiac neoplasm that is increasingly detected by echocardiography. The clinical manifestations of this entity are not well described. METHODS AND RESULTS: In a 16-year period, we identified patients with CPF from our pathology and echocardiography databases. A total of 162 patients had pathologically confirmed CPF. Echocardiography was performed in 141 patients with 158 CPFs, and 48 patients had CPFs that were not visible by echocardiography (<0.2 cm), leaving an echocardiographic subgroup of 93 patients with 110 CPFs. An additional 45 patients with a presumed diagnosis of CPF were identified. The mean age of the patients was 60+/-16 years of age, and 46.1% were male. Echocardiographically, the mean size of the CPFs was 9+/-4.6 mm; 82.7% occurred on valves (aortic more than mitral), 43.6% were mobile, and 91.4% were single. During a follow-up period of 11+/-22 months, 23 of 26 patients with a prospective diagnosis of CPF that was confirmed by pathological examination had symptoms that could be attributable to embolization. In the group of 45 patients with a presumed diagnosis of CPF, 3 patients had symptoms that were likely due to embolization (incidence, 6.6%) during a follow-up period of 552+/-706 days. CONCLUSIONS: CPFs are generally small and single, occur most often on valvular surfaces, and may be mobile, resulting in embolization. Because of the potential for embolic events, symptomatic patients, patients undergoing cardiac surgery for other lesions, and those with highly mobile and large CPFs should be considered for surgical excision.

NASA Discipline Cardiopulmonary↗

Calibrating CERES and VIIRS using CLARREO Pathfinder: Adjustment for the Viewing Geometry Mismatch

The Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission on the International Space Station (ISS) will provide, for the first-time, an SI-traceable on-orbit calibration reference with a reflectance uncertainty of 0.3% (1 sigma). One major mission objective is to demonstrate the capability of transferring CPF’s radiometric accuracy to other satellite-based instruments, such as Clouds and Earth's Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS) on NOAA-20. CPF inter-calibration measurements will be planned to obtain inter-calibration samples that closely match satellite-based target sensor observations in time, space, angle, and wavelength. The inter-calibration event observations cover a wide range of viewing geometry angles with potential angular mismatch between CPF and the target sensors which can introduce non-negligible errors against the mission’s inter-calibration uncertainty budget. We will introduce the CPF approach to adjust for angular mismatch differences, thereby reducing the incurred uncertainties to within the inter-calibration uncertainty budget. The angular adjustment algorithm has been developed and validated based on the high-fidelity simulations of the CPF spectra using the Principal Component based Radiative Transfer Model (PCRTM). The implementation of the algorithm on event simulation data and the characterization for the angular adjustment uncertainty will be presented.

Wan Wu↗

Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder Intercalibration Data Analysis Strategy

One of the prime science objectives of NASA’s Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission is to acquire unprecedentedly accurate Système Internationale (SI)-traceable Earth-view measurements that can be used as reference for intercalibrating the Clouds and the Earth’s Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS) instruments onboard NOAA-20 satellite. The hyperspectral nature of CPF measurements will significantly reduce spectrally induced biases when intercalibrating multiband or broadband satellite instruments with CPF. This advancement eliminates the requirement for spectral band adjustment factors, representing a substantial improvement in sensor intercalibration studies. The CPF intercalibration team is aiming to achieve a maximum intercalibration methodology uncertainty of 0.3 % (k=1). Our studies have revealed that the most significant contribution to the targeted uncertainty budget originates from the combined effects of spatial and temporal matching errors. Spatial matching error arises from discrepancies in CPF and target instrument pixel resolution and geolocation uncertainty, while temporal matching error is caused by changes in scene radiances over time, occurring between when the target and reference instruments observe the same scenes. To estimate the maximum expected uncertainty contribution from these sources, spatial and temporal matching noise analyses were conducted using algorithmically filtered Landsat 9 Operational Land Imager (OLI) and Geostationary Operational Environmental Satellite (GOES)-16 ABI CONUS scan data as proxies for CPF and target instruments. In the upcoming conference presentation, we will elaborate on the methodology employed in these experiments, provide details of the data filtering algorithms, and present results of the spatial and temporal matching uncertainty analyses.

Intercalibration↗

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit↗

Evaluation of Systematic Errors on Polarization Parameters from POLDER Instrument Data for Use In CLARREO Pathfinder-VIIRS Intercalibration

One of the CLARREO Pathfinder (CPF) mission’s science objectives is to intercalibrate the reflective solar bands of the NOAA-20 VIIRS instrument against high-accuracy CPF measurements utilizing coincident, co-angled, and co-located footprints acquired over diverse Earth targets. To alleviate the effect of high polarization sensitivity of select VIIRS channels on intercalibration analysis, the CPF team will limit the intercalibration footprints over low-polarized scene types, which will be identified based on an empirical estimation of their degree and angle of polarization (DOP and AOP) using POLDER data. This paper describes the methodology for evaluating systematic errors in the estimation of DOP and AOP for Earth-reflected radiances using POLDER’s polarized bands and investigates their potential impact on CPF-VIIRS intercalibration uncertainty. The systematic errors were found to be less than 0.01 for DOP and less than 2.2 deg. for AOP, which will have a negligible impact on CPF-VIIRS intercalibration uncertainty.

polarization↗

Reference Intercalibration for the Climate Observing System

Reference Intercalibration is critical in supporting the construction of climate data records, which, given their necessary longevity, must consist of measurements from multiple instruments. Reference intercalibration enables placing multiple instruments on the same radiometric scale, reducing calibration-based biases in climate data records. Measurements that have characteristics of a climate benchmark make excellent in-orbit intercalibration references. Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) consists of a reflected solar (RS) spectrometer (350-2300 nm) that will take hyperspectral Earth reflectance measurements with unprecedented SI-traceable accuracy (0.3%, 1-sigma) from the International Space Station (ISS). CPF measurements will have several characteristics of climate benchmark measurements and will demonstrate its capability as a rigorous in-orbit intercalibration reference with Clouds and Earth’s Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS). The methodologies that have been developed to support CPF-CERES and CPF-VIIRS intercalibration can readily be extended to other Low Earth Orbit and Geostationary instrument targets. With its highly accurate hyperspectral observations, CPF measurements can also be used to improve the characterization of targets widely used for satellite instrument vicarious calibration including Earth land surface pseudo-invariant calibration sites, deep convective clouds, and the Moon. We will discuss the importance of climate benchmark measurement attributes for intercalibration and considerations for the associated intercalibration data analysis to support building and maintaining climate data records.

Yolanda Shea↗

Estrous Cyclicity in Mice During Simulated Weightlessness

Hindlimb unloading (HU) is a rodent model system used to simulate weightlessness experienced in space. However, some effects of this approach on rodent physiology are under-studied, specifically the effects on ovarian estrogen production which drives the estrous cycle. To resolve this deficiency, we conducted a ground-based validation study using the HU model, while monitoring estrous cycles in 16-weeks-old female C57BL6 mice. Animals were exposed to HU for 12 days following a 3 day HU cage acclimation period, and estrous cycling was analyzed in HU animals (n=22), normally loaded HU Cage Pair-Fed controls (CPF; n=22), and Vivarium controls fed ad libitum (VIV; n=10). Pair feeding was used to control for potential nutritional deficits on ovarian function. Vaginal cells were sampled daily in all mice via saline lavage. Cells were dried and stained with crystal violet, and the smears evaluated using established vaginal cytology techniques by two individuals blinded to the animal treatment group. Estrous cyclicity was disrupted in nearly all HU and CPF mice, while those maintained in VIV had an average normal cycle length of 4.8+/- 0.5 days, with all stages in the cycle visibly observed. CPF and HU animals arrested in the diestrous phase, which precedes the pre-ovulatory estrogen surge. Additionally, infection-like symptoms characterized by vaginal discharge and swelling arose in several HU animals, which we suspect was due to an inability of these mice to properly groom themselves, and/or due to the change in the gravity vector relative to the vaginal opening, which prevented drainage of the lavage solution. Pair-feeding resulted in similar weight gains of HU and CPF (1.5% vs 3.0%, respectively). The current results indicate that pair-feeding controlled weight gain and that the HU cage alone influenced estrous cyclicity. Thus, longer acclimation needs to be tested to determine if and when normal estrous cycling resumes in non-loaded mice in HU cages prior to HU testing. Future studies might also examine whether modifications to the vaginal lavage procedure might prevent the onset of the infection-like symptoms, and allow estrous cyclicity to be measured in this model system. Research supported by NNX15AB48G to JST.

Hindlimb Unloading↗

Estrous Cyclicity of Mice During Simulated Weightlessness

Hindlimb unloading (HU) is a rodent model system used to simulate weightlessness experienced in space. However, some effects of this approach on rodent physiology are under-studied, specifically the effects on ovarian estrogen production which drives the estrous cycle. To resolve this deficiency, we conducted a ground-based validation study using the HU model, while monitoring estrous cycles in 16-weeks-old female C57BL6 mice. Animals were exposed to HU for 12 days following a 3 day HU cage acclimation period, and estrous cycling was analyzed in HU animals (n22), normally loaded HU Cage Pair-Fed controls (CPF; n22), and Vivarium controls fed ad libitum (VIV; n10). Pair feeding was used to control for potential nutritional deficits on ovarian function. Vaginal cells were sampled daily in all mice via saline lavage. Cells were dried and stained with crystal violet, and the smears evaluated using established vaginal cytology techniques by two individuals blinded to the animal treatment group. Estrous cyclicity was disrupted in nearly all HU and CPF mice, while those maintained in VIV had an average normal cycle length of 4.8 0.5 days, with all stages in the cycle visibly observed. CPF and HU animals arrested in the diestrous phase, which precedes the pre-ovulatory estrogen surge. Additionally, infection-like symptoms characterized by vaginal discharge and swelling arose in several HU animals, which we suspect was due to an inability of these mice to properly groom themselves, andor due to the change in the gravity vector relative to the vaginal opening, which prevented drainage of the lavage solution. Pair-feeding resulted in similar weight gains of HU and CPF (1.5 vs 3.0, respectively). The current results indicate that pair-feeding controlled weight gain and that the HU cage alone influenced estrous cyclicity. Thus, longer acclimation needs to be tested to determine if and when normal estrous cycling resumes in non-loaded mice in HU cages prior to HU testing. Future studies might also examine whether modifications to the vaginal lavage procedure might prevent the onset of the infection-like symptoms, and allow estrous cyclicity to be measured in this model system.

fertilit↗

CLARREO Pathfinder: Mission Overview and Current Status

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission consists of a high accuracy reflected solar spectrometer that will take measurements from the International Space Station for one year starting in 2023. CPF will demonstrate that its novel on-orbit absolute calibration approaches are capable of achieving 0.3% (1-sigma) radiometric uncertainty. Additionally, using its two-axis pointing gimbal which enables nearly-concurrent measurements matching look angles with other orbiting sensors, CPF will demonstrate a novel inter-calibration approach by inter-calibrating CERES and VIIRS. CPF is currently in its Final Design and Fabrication Stage and recently passed its Critical Design Review.

Yolanda Shea↗

CLARREO Pathfinder: Mission Status and Current Status

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission consists of a high accuracy reflected solar spectrometer that will take measurements from the International Space Station for one year starting in 2023. CPF will demonstrate that its novel on-orbit absolute calibration approaches are capable of achieving 0.3% (1-sigma) radiometric uncertainty. Additionally, using its two-axis pointing gimbal which enables nearly-concurrent measurements matching look angles with other orbiting sensors, CPF will demonstrate a novel inter-calibration approach by inter-calibrating CERES and VIIRS. CPF is currently in its Final Design and Fabrication Stage and recently passed its Critical Design Review.

Yolanda Shea↗

Clarreo Pathfinder: Mission Overview and Current Status

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission consists of a high accuracy reflected solar spectrometer that will take measurements from the International Space Station for one year starting in 2023. CPF will demonstrate that its novel on-orbit absolute calibration approaches are capable of achieving 0.3% (1-sigma) radiometric uncertainty. Additionally, using its two-axis pointing gimbal which enables nearly-concurrent measurements matching look angles with other orbiting sensors, CPF will demonstrate a novel inter-calibration approach by inter-calibrating CERES and VIIRS. CPF is currently in its Final Design and Fabrication Stage and recently passed its Critical Design Review.

accuracy↗

NASA's CLARREO Pathfinder Mission: The Reflected Solar’s First SITSat

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder mission will take reflected solar (RS) highly accurate measurements needed to monitor Earth’s climate and will be the first RS SI-traceable Satellite Sensor (SITSat). The mission includes a RS spectrometer that will be installed on the International Space Station (ISS) and take measurements for at least one year. CLARREO Pathfinder (CPF) will use on-orbit calibration to achieve an unprecedented high accuracy with SI-traceability and the inter-calibration of other on-orbit instruments. The spectrometer is based on the HyperSpectral Imager for Climate Science (HySICS) instrument developed by the University of Colorado/Laboratory for Atmospheric and Space Physics of Boulder, CO, USA. HySICS is being designed to have a radiometric uncertainty of 0.3% (1-sigma), a five to ten times improvement over existing spaceflight RS instruments. High accuracy SI-traceable measurements such as these are critical to develop long-term climate-quality data sets. Additionally, by measuring spectral reflectance with high accuracy the CPF instrument will serve as an on-orbit intercalibration radiometric reference for operational Earth-viewing sensors, such as the Clouds and Earth’s Radiant Energy System (CERES) broadband shortwave instrument and the Visible/Infrared Imaging Radiometer Suite (VIIRS). Two-axis pointing, a spectral range from 350 nm to 2300 nm, and a spectral resolution ≤6 nm enable CPF to provide nearly coincident temporal, spatial, angular, and spectral matching of intercalibration targets, with sampling sufficient to reduce random errors. The intercalibration method will refine knowledge of target sensors’ effective offsets, gain, non-linearity, spectral response, and polarization sensitivity (as is relevant). Calibrated reflectance and reflected radiance spectra will be distributed to the scientific community through a NASA Distributed Active Archive Center (DAAC). We will present an overview of the CLARREO Pathfinder mission, its anticipated impact on monitoring climate variability, and the novel CPF direct intercalibration approach.

climate↗

A modified coupled pair functional approach

A modified coupled pair functional (CPF) method is presented for the configuration interaction problem that dramatically improves properties for cases where the Hartree-Fock reference configuration is not a good zeroth-order wave function description. It is shown that the tendency for CPF to overestimate the effect of higher excitations arises from the choice of the geometric mean for the partial normalization denominator. The modified method is demonstrated for ground state dipole moment calculations of the NiH, CuH, and ZnH transition metal hydrides, and compared to singles-plus-doubles configuration interaction and the Ahlrichs et al. (1984) CPF method.

Chong, D. P.↗

Implementation of control point form of algebraic grid-generation technique

The control point form (CPF) provides explicit control of physical grid shape and grid spacing through the movement of the control points. The control point array, called a control net, is a space grid type arrangement of locations in physical space with an index for each direction. As an algebraic method CPF is efficient and works well with interactive computer graphics. A family of menu-driven, interactive grid-generation computer codes (TURBO) is being developed by using CPF. Key features of TurboI (a TURBO member) are discussed and typical results are presented. TurboI runs on any IRIS 4D series workstation.

Choo, Yung K.↗

Implementation of control point form of algebraic grid-generation technique

The control point form (CPF) provides explicit control of physical grid shape and grid spacing through the movement of the control points. The control point array, called a control net, is a space grid type arrangement of locations in physical space with an index for each direction. As an algebraic method CPF is efficient and works well with interactive computer graphics. A family of menu-driven, interactive grid-generation computer codes (TURBO) is being developed by using CPF. Key features of TurboI (a TURBO member) are discussed and typical results are presented. TurboI runs on any IRIS 4D series workstation.

Choo, Yung K.↗

Assessment of VIIRS on-orbit polarization sensitivity and its impact on CLARREO pathfinder inter-calibration

The primary objective of the CLARREO Pathfinder (CPF) mission is to demonstrate essential measurement technologies to enable highly accurate decadal change observations traceable on-orbit to SI standards. Another important objective of the CPF is to demonstrate inter-calibration with the VIIRS sensor and to show that such high-accuracy reference inter-calibration is achievable. To satisfy this requirement, it is important to understand and quantify uncertainties in VIIRS sensor measurements. Based on prelaunch test results, the reflective solar bands of both SNPP and NOAA-20 VIIRS have exhibited polarization sensitivities in the shortest wavelength bands, with an unexpectedly larger sensitivity observed for NOAA-20 VIIRS, particularly in bands M1 to M4. In this study, we use VIIRS Level-1B reflectance data collected over the Pseudo-Invariant Calibration Sites over North African desert region to examine the polarization associated uncertainty for these four bands. Impact due to BRDF on the reflectance data is considered by comparing baseline results obtained from the same viewing and solar zenith angles under relatively low polarization sensitivity. Impact due to detector relative difference in polarization sensitivity is examined by normalizing reflectances by the value of the middle detector. Results of this study provide useful information on VIIRS uncertainty contribution due to polarization when conducting CPF and VIIRS inter-calibration.

VIIRS↗

Independent Calibration Approach for the CLARREO Pathfinder Mission

A CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) mission has been funded to demonstrate retrieval of SI-traceable spectral reflectance with absolute uncertainty <0.3% (k=1). The mission consists of a Reflected Solar spectrometer that will be hosted on the International Space Station (ISS) in the 2023 timeframe and rely on a ratioing radiometer approach to retrieve the unprecedented accuracy. Demonstrating that the accuracy is achieved through an Independent Calibration effort similar in philosophy to the efforts in metrology laboratories relying on multiple, independent measurements to improve credibility for a sensor’s absolute and relative uncertainty error budgets. These measurements use different traceability paths and multiple instrument approaches and CPF’s Independent Calibration will be similar in this regard. The Independent Calibration relies on a pre-launch absolute radiometric calibration obtained from additional testing done after instrument thermal-vacuum (TVAC) testing. The added radiometric calibration is combined with a high fidelity instrument model to provide an on-orbit radiometric calibration independent from the ratioing radiometer approach. The current work describes the post-TVAC testing portion of the CPF Independent Calibration Plan and the Independent Model Development as well as planned on-orbit Evaluation of the Independent Calibration.

CLARREO Pathfinder↗

Spatial Correlations of the Poisson Model for Radiation Transport

Characterizing the relationship between bulk physical properties and mixing in randomly heterogeneous media is a central challenge across many areas of science and engineering. A benchmark model for such studies is the Poisson model, a random tessellation of space by a Poisson process of hyperplanes. In radiation transport studies, the lack of exact expressions for the Poisson model’s spatial multipoint functions has led to approximate methods being used, introducing unquantified sources of error. Here, we recently introduced an exact solution for the Poisson model’s multipoint functions and closely related conditional probability functions (CPFs), providing a new opportunity to understand and reduce these sources of error. In this paper, we enable a more rigorous investigation of radiation transport in stochastic media by applying the recently introduced exact solution for the Poisson model’s CPFs. This paper consists of three main contributions. First, we introduce a unified framework for CPFs of the Poisson model, encompassing the recently introduced exact CPFs as well as the previously introduced atomic mix, nearest-neighbor, and combination CPFs. This framework also includes existing pruning techniques for the approximate CPFs, such as angular exclusion, as well as a novel form of angular exclusion suitable for the exact CPFs. Second, we use the exact CPFs to characterize the spatial regions where each approximate three-point CPF is most accurate, thereby explaining the observed hierarchy of accuracy among the approximate models. Finally, we evaluate material transmittance, reflectance, and flux in a three-dimensional test problem using conditional point sampling, demonstrating the relationship between CPF accuracy and transport simulation accuracy.

Poisson model↗