Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Technology Overview: Concentrator PV 2010 Boot Camp (CPV) (Presentation)

The presentation introduces the various types of CPV technologies and provides a status report of today's CPV companies. Six different architectures of multijunction cells are shown to near or surpass 40% in efficiency. The design space for CPV is quite complex, which is a curse for those trying to narrow it down for the first prototype, but a blessing for those who want multiple pathways forproduct improvement in coming years.

14 SOLAR ENERGY↗

Component Cell-Based Restriction of Spectral Conditions and the Impact on CPV Module Power Rating

One approach to consider the prevailing spectral conditions when performing CPV module power ratings according to the standard IEC 62670-3 is based on spectral matching ratios (SMRs) determined by the means of component cell sensors. In this work, an uncertainty analysis of the SMR approach is performed based on a dataset of spectral irradiances created with SMARTS2. Using these illumination spectra, the respective efficiencies of multijunction solar cells with different cell architectures are calculated. These efficiencies were used to analyze the influence of different component cell sensors and SMR filtering methods. The 3 main findings of this work are as follows. First, component cells based on the lattice-matched triple-junction (LM3J) cell are suitable for restricting spectral conditions and are qualified for the standardized power rating of CPV modules - even if the CPV module is using multijunction cells other than LM3J. Second, a filtering of all 3 SMRs with +/-3.0% of unity results in the worst case scenario in an underestimation of -1.7% and overestimation of +2.4% compared to AM1.5d efficiency. Third, there is no benefit in matching the component cells to the module cell in respect to the measurement uncertainty.

14 SOLAR ENERGY↗

Determining Outdoor CPV Cell Temperature: Preprint

An accurate method is needed for determining cell temperature when measuring CPV modules outdoors. It has been suggested that cell temperature can be calculated though a procedure that shutters sunlight to the cells while measuring the transients in open-circuit voltage (Voc) and heat sink temperature. This paper documents application of this shutter procedure to multiple CPV modules at NREL. Thechallenges and limitations are presented along with an alternate approach to measuring CPV cell operating temperature.

14 SOLAR ENERGY↗

Modeling Thermal Fatigue in CPV Cell Assemblies: Preprint

A finite element model has been created to quantify the thermal fatigue damage of the CPV die attach. Simulations are used to compare to results of empirical thermal fatigue equations originally developed for accelerated chamber cycling. While the empirical equations show promise when extrapolated to the lower temperature cycles characteristic of weather-induced temperature changes in the CPV dieattach, it is demonstrated that their damage does not accumulate linearly: the damage a particular cycle contributes depends on the preceding cycles. Simulations of modeled CPV cell temperature histories provided for direct comparison of the FEM and empirical methods, and for calculation of equivalent times provided by standard accelerated test sequences.

14 SOLAR ENERGY↗

Flat ATIR Optics Approach to CPV: December 3, 2009 - December 3, 2010 (Revised)

An agglomeration of factors has stifled the economic promise of CPV technology. Foremost among these factors are: insufficient optical efficiency, misfit with existing solar infrastructure and production capabilities, and inadequate reliability of the optic-receiver pairing. These difficulties are largely driven by the choice of optics. The CPV industry is constrained in a paradigm of bulkyreflective or refractive optics that operate best at either low concentration (2-5X) or high concentration (100X and above). Low concentration approaches are plagued by marginal economics, while high concentration approaches face heightened technical risks. High concentration systems inevitably face thermal management hurdles and often do not fit well with the existing solar infrastructure.Using Aggregated Total Internal Reflection (ATIR) as the optical mechanism for gathering light, a cost effective, line-focus optic can be produced at scale to provide superior optical efficiency in a flat profile and operate at a mid level of concentration to mitigate the tradeoff between economic benefit and adoptability. Substantiating this motivational premise behind the ATIR optics approachto CPV requires performance data. Foremost among the goals for establishing the viability of ATIR optics in solar is demonstrating optical efficiency. Banyan Energy performed an outdoor test of optical efficiency (OE) based on short circuit current using the line-focus Lens Step prototype.

14 SOLAR ENERGY↗

Determining Outdoor CPV Cell Temperature (Presentation)

An accurate method is needed for determining cell temperature when measuring CPV modules outdoors. It has been suggested that cell temperature can be calculated though a procedure that shutters sunlight to the cells while measuring the transients in open-circuit voltage (Voc) and heat sink temperature. This presentation documents application of this shutter procedure to multiple CPV modules atNREL. The challenges and limitations are presented along with an alternate approach to measuring CPV cell operating temperature.

14 SOLAR ENERGY↗

Chapter 6: CPV Tracking and Trackers

This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurement with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.

14 SOLAR ENERGY↗

Chapter 10: CPV Multijunction Solar Cell Characterization

Characterization of solar cells can be divided into two types: the first is measurement of electrooptical semiconductor device parameters, and the second is determination of electrical conversion efficiency. This chapter reviews the multijunction concepts that are necessary for understanding Concentrator photovoltaic (CPV) cell characterization techniques, and describes how CPV efficiency is defined and used. For any I-V measurement of a multijunction cell, the sun simulator spectrum has to be adjusted in a way that all junctions generate the same photocurrent ratios with respect to each other as under reference conditions. The chapter discusses several procedures for spectral irradiance adjustments of solar simulators, essential for multijunction measurements. It overviews the light sources and optics commonly used in simulators for CPV cells under concentration. Finally, the chapter talks about the cell area, quantum efficiency (QE), and current-voltage (I-V) curve measurements that are needed to characterize cells as a function of irradiance.

14 SOLAR ENERGY↗

Considerations for How to Rate CPV

The concentrator photovoltaic (CPV) industry is introducing multiple products into the marketplace, but, as yet, the; community has not embraced a unified method for assessing a nameplate rating. The choices of whether to use 850,; 900, or 1000 W/m2 for the direct-normal irradiance and whether to link the rating to ambient or cell temperature will; affect how CPV modules are rated and compared with other technologies. This paper explores the qualitative and; quantitative ramifications of these choices using data from two multi-junction CPV modules and two flat-plate; modules.

14 SOLAR ENERGY↗

AIST-NREL Concentrator Photovoltaic (CPV) Demonstration. Cooperative Research and Development Final Report, CRADA Number CRD-10-402

The purpose of the project is to demonstrate and quantitatively compare performance of CPV systems installed in Japan and in the United States. The deployment conditions (e.g. spectrum and temperature) are site dependent and the optimal design of the system may vary with location. The CPV systems will use multi-junction concentrator cells for the conversion of sunlight into electricity. The optimal design of the cell may depend on the location at which a CPV system is installed. Thus, the systems in Japan and in the U.S. will all use a combination of concentrator cells obtained from three different vendors. This CRADA pertains only to the equipment that will be installed in the U.S. This effort is a collaborative project between AIST and NREL.

14 SOLAR ENERGY↗

Coupled Thermo-Mechanical and Photo-Chemical Degradation Mechanisms that determine the Reliability and Operational Lifetimes for CPV Technologies

This project sought to identify and characterize the coupled intrinsic photo-chemo-mechanical degradation mechanisms that determine the reliability and operational lifetimes for CPV technologies. Over a three year period, we have completed a highly successful program which has developed quantitative metrologies and detailed physics-based degradation models, providing new insight into the fundamental reliability physics necessary for improving materials, creating accelerated testing protocols, and producing more accurate lifetime predictions. The tasks for the program were separated into two focus areas shown in the figure below. Focus Area 1, led by Reinhold Dauskardt and Warren Cai with a primary collaboration with David Miller of NREL, studied the degradation mechanisms present in encapsulant materials. Focus Area 2, led by Reinhold Dauskardt and Ryan Brock with a primary collaboration with James Ermer and Peter Hebert of Spectrolab, studied stress development and degradation within internal CPV device interfaces. Each focus area was productive, leading to several publications, including findings on the degradation of silicone encapsulant under terrestrial UV, a model for photodegradation of silicone encapsulant adhesion, quantification and process tuning of antireflective layers on CPV, and discovery of a thermal cycling degradation mechanism present in metal gridline structures.

36 MATERIALS SCIENCE↗

Unique features of a new nickel-hydrogen 2-cell CPV

Two-cell nickel-hydrogen common pressure vessel (CPV) units with some unusual design features have been successfully built and tested. The features of interest are half-normal platinum loading for the negative electrodes, the use of rabbit-ear terminals for a CPV unit, and the incorporation of a wall wick. The units have a nominal capacity of 20 Ah and are 3.5 inches in diameter. Electric performance data are provided. The data support the growing viability of the two-cell CPV design concept.

Wheeler, James R.↗

Minimizing Variation in Outdoor CPV Power Ratings (Presentation)

Module data from NREL's CPV test bed is used to examine methods for calculating outdoor CPV power ratings. IEC 62670 and ASTM E2527 are used as a starting point for determining a module power rating on a monthly basis. Monthly power ratings vary by more than desired using existing methods. The presentation examines modifications to existing methods as well as spectral corrections to reducevariation in monthly module power ratings.

14 SOLAR ENERGY↗

Minimizing Variation in Outdoor CPV Power Ratings (Presentation)

Presented at the 7th International Conference on Concentrating Photovoltaic Systems (CPV-7), 4-6 April 2011, Las Vegas, Nevada. The CPV community has agreed to have both indoor and outdoor power ratings at the module level. The indoor rating provides a repeatable measure of module performance as it leaves the factory line while the outdoor rating provides a measure of true performance under realworld conditions. The challenge with an outdoor rating is that the spectrum, temperature, wind speed, etc are constantly in flux and therefore the resulting power rating varies from day to day and month to month. This work examines different methodologies for determining the outdoor power rating with the goal of minimizing variation even if data are collected under changing meteorologicalconditions.

14 SOLAR ENERGY↗

Effect of soiling in CPV systems

The effect of soiling in flat PV modules has been already studied, causing a reduction of the electrical output of 4% on average. For CPV's, as far as soiling produces light scattering at the optical collector surface, the scattered rays should be definitively lost because they cannot be focused onto the receivers again. While the theoretical study becomes difficult because soiling is variable at different sites, it becomes easier to begin the monitoring of the real field performance of concentrators and then raise the following question: how much does the soiling affect to PV concentrators in comparison with flat panels?' The answers allow to predict the PV concentrator electrical performance and to establish a pattern of cleaning frequency. Some experiments have been conducted at the IES-UPM and CSES-ANU sites, consisting in linear reflective concentration systems, a point focus refractive concentrator and a flat module. All the systems have been measured when soiled and then after cleaning, achieving different increases of I{sub SC}. In general, results show that CPV systems are more sensitive to soiling than flat panels, accumulating losses in I{sub SC} of about 14% on average in three different tests conducted at IES-UPM and CSES-ANU test sites in Madrid (Spain) and Canberra (Australia). Some concentrators can reach losses up to 26% when the system is soiled for 4 months of exposure. (author)

14 SOLAR ENERGY↗