Search NASA⌕ Search

SEARCH · Search NASA

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integrated high electron mobility transistors in GaAs/AlGaAs heterostructures for amplification at sub-Kelvin temperatures

Here, we demonstrate the use of custom high electron mobility transistors (HEMTs) fabricated in GaAs/AlGaAs heterostructures to amplify current from quantum dot devices. The amplifier circuit is located adjacent to the quantum dot device, at sub-Kelvin temperatures, in order to reduce the impact of cable capacitance and environmental noise. Using this circuit, we show a current gain of 380 for 0.56 μW of power dissipation, with a bandwidth of 2.7 MHz and current noise referred to the input of 24 fA/Hz 1/2 for frequencies of 0.1–1 MHz. The power consumption required for similar gain is reduced by more than a factor of 20 compared to a previous demonstration using a commercial off-the-shelf HEMT. Lastly, we also demonstrate integration of a HEMT amplifier circuit on-chip with a quantum dot device, which has the potential to reduce parasitics and should allow for more complex circuits with reduced footprints.

42 ENGINEERING↗

SENSEI: Characterization of Single-Electron Events Using a Skipper Charge-Coupled Device

We use a science-grade skipper charge-coupled device (skipper CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89±0.77)×10 -4 e - /pix/day, and an unprecedentedly low spurious charge contribution of (1.52±0.07)×10 -4 e - /pix, which is exposure independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing research and development efforts of skipper and conventional CCDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as ``dark counts'': dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple degree-of-freedom force and moment measurement for static propulsion testing using magnetic suspension technology

Innovative Information Systems (IIS), Inc. is in the process of designing and fabricating a high bandwidth force and moment measuring device (i.e. the Magnetic Thruster Test Stand). This device will use active magnetic suspension to allow direct measurements of the forces and torques generated by the rocket engines of the missile under test. The principle of operation of the Magnetic Thruster Test Stand (MTTS) is based on the ability to perform very precise, high bandwidth force and position measurements on an object suspended in a magnetic field. This ability exists due to the fact that the digital servo control mechanism that performs the magnetic suspension uses high bandwidth (10 kHz) position data (via an eddy-current proximity sensor) to determine the amount of force required to maintain stable suspension at a particular point. This force is converted into required electromagnet coil current, which is then output to a current amplifier driving the coils. A discussion of how the coil current and magnetic gap distance (the distance between the electromagnet and the object being suspended) is used to determine the forces being applied from the suspended assembly is presented.

Stuart, Keith↗

High power continuous operation of a widely tunable quantum cascade laser with an integrated amplifier

Wide electrical tuning and high continuous output power is demonstrated from a single mode quantum cascade laser emitting at a wavelength near 4.8 μm. This is achieved in a space efficient manner by integrating an asymmetric sampled grating distributed feedback tunable laser with an optical amplifier. An initial demonstration of high peak power operation in pulsed mode is demonstrated first, with >5 W output over a 270 nm (113 cm{sup −1}) spectral range. Refinement of the geometry leads to continuous operation with a single mode spectral coverage of 300 nm (120 cm{sup −1}) and a maximum continuous power of 1.25 W. The output beam is shown to be nearly diffraction-limited, even at high amplifier current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconducting quantum interference devices based set-up for probing current noise and correlations in three-terminal devices

We have implemented a new experimental set-up for precise measurements of current fluctuations in three-terminal devices. The system operates at very low temperatures (30 mK) and is equipped with three superconducting quantum interference devices (SQUIDs) as low noise current amplifiers. A SQUID input coil is connected to each terminal of a sample allowing the acquisition of time-dependent current everywhere in the circuit. From these traces, we can measure the current mean value, the noise, and cross-correlations between different branches of a device. In this paper, we present calibration results of noise and cross-correlations obtained using low impedance macroscopic resistors. From these results, we can extract the noise level of the set-up and show that there are no intrinsic correlations due to the measurement scheme. We also studied noise and correlations as a function of a dc current and estimated the electronic temperature of various macroscopic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DE-AC accelerator system for high beam current density

A radically different ion accelerator system design has been developed to increase the extracted beam current density of ion thrusters. By independently controlling plasma ion extraction and acceleration, the Decoupled Extraction and Amplified Current (DE-AC) accelerator system gives higher beam currents at lower electric field stress levels. Results are presented for DE-AC grid system operation with the Test Bed Ion Engine. Using argon propellant, feasibility of a 60 mA/sq cm beam current density is shown. A discussion of power supply requirements, specific impulse operation and grid system geometrical design is presented also.

Aston, G.↗

2250-MHz High Efficiency Microwave Power Amplifier (HEMPA)

Tnis paper will focus on developing an exotic switching technique that enhances the DC-to-RF conversion efficiency of microwave power amplifiers. For years, switching techniques implemented in the 10 kHz to 30 MHz region have resulted in DC-to-RF conversion efficiencies of 90-95-percent. Currently amplifier conversion efficiency, in the 2-3 GHz region approaches, 10-20-percent. Using a combination of analytical modeling and hardware testing, a High Efficiency Microwave Power Amplifier was built that demonstrated conversion efficiencies four to five times higher than current state of the art.

Sims, W. Herbert↗

High Efficiency Microwave Power Amplifier (HEMPA) Design

This paper will focus on developing an exotic switching technique that enhances the DC-to-RF conversion efficiency of microwave power amplifiers. For years, switching techniques implemented in the 10 kHz to 30 MHz region have resulted in DC-to-RF conversion efficiencies of 90-95-percent. Currently amplifier conversion efficiency, in the 2-3 GHz region approaches, 10-20-percent. Using a combination of analytical modeling and hardware testing, a High Efficiency Microwave Power Amplifier was built that demonstrated conversion efficiencies four to five times higher than current state of the art.

Sims, W. Herbert↗

High Efficiency Microwave Power Amplifier (HEMPA) Design

This paper will focus on developing an exotic switching technique that enhances the DC-to-RF conversion efficiency of microwave power amplifiers. For years, switching techniques implemented in the 10 kHz to 30 MHz region have resulted in DC-to-RF conversion efficiencies of 90-95-percent. Currently amplifier conversion efficiency, in the 2-3 GHz region approaches, 10-20-percent. Using a combination of analytical modeling and hardware testing, a High Efficiency Microwave Power Amplifier was built that demonstrated conversion efficiencies four to five times higher than current state of the art.

Sims, W. Herbert↗

A new dry biomedical electrode

Electronic circuitry contains new operational amplifier which incorporates monolithic super-gain transistors. Electrode does not provide voltage amplification; instead, it acts as current amplifier to make it possible to pick up electrical potentials from surface of highly resistant dry skin.

Luce, R. S.↗

High-Power, High-Frequency Si-Based (SiGe) Transistors Developed

Future NASA, DOD, and commercial products will require electronic circuits that have greater functionality and versatility but occupy less space and cost less money to build and integrate than current products. System on a Chip (SOAC), a single semiconductor substrate containing circuits that perform many functions or containing an entire system, is widely recognized as the best technology for achieving low-cost, small-sized systems. Thus, a circuit technology is required that can gather, process, store, and transmit data or communications. Since silicon-integrated circuits are already used for data processing and storage and the infrastructure that supports silicon circuit fabrication is very large, it is sensible to develop communication circuits on silicon so that all the system functions can be integrated onto a single wafer. Until recently, silicon integrated circuits did not function well at the frequencies required for wireless or microwave communications, but with the introduction of small amounts of germanium into the silicon to make silicon-germanium (SiGe) transistors, silicon-based communication circuits are possible. Although microwavefrequency SiGe circuits have been demonstrated, there has been difficulty in obtaining the high power from their transistors that is required for the amplifiers of a transmitter, and many researchers have thought that this could not be done. The NASA Glenn Research Center and collaborators at the University of Michigan have developed SiGe transistors and amplifiers with state-of-the-art output power at microwave frequencies from 8 to 20 GHz. These transistors are fabricated using standard silicon processing and may be integrated with CMOS integrated circuits on a single chip. A scanning electron microscope image of a typical SiGe heterojunction bipolar transistor is shown in the preceding photomicrograph. This transistor achieved a record output power of 550 mW and an associated power-added efficiency of 33 percent at 8.4 GHz, as shown. Record performance was also demonstrated at 12.6 and 18 GHz. Developers have combined these state-of-the-art transistors with transmission lines and micromachined passive circuit components, such as inductors and capacitors, to build multistage amplifiers. Currently, a 1-W, 8.4-GHz power amplifier is being built for NASA deep space communication architectures.

Ponchak, George E.↗

An analysis of carrier dynamics in methylammonium lead triiodide perovskite solar cells using cross correlation noise spectroscopy

Using cross correlation current noise spectroscopy, we have investigated carrier dynamics in methylammonium lead triiodide solar cells. This method provides space selectivity for devices with a planar multi-layered structure, effectively amplifying current noise contributions coming from the most resistive element of the stack. In the studied solar cells, we observe near full-scale shot noise, indicating the dominance of noise generation by a single source, likely the interface between the perovskite and the spiro-organic 2,2',7,7'-tetrakis(N,N-di-p-methoxyphenyl-amine)9,9'-spirobifluorene hole-transport layer. In this paper, we argue that the strong 1/f noise term has contributions from both the perovskite layer and interfaces. It displays a non-ideal dependence on photocurrent, S $\propto$ I 1.4 (instead of usual S $\propto$ I 2 ), which is likely due to current-induced halide migration. Finally, we observe generation–recombination noise. We argue that this contribution is due to bimolecular recombination in the perovskite bulk absorption layer. Extrapolating our results, we estimate that at standard 1 sun illumination, the electron–hole recombination time is 5 microseconds.

14 SOLAR ENERGY↗

Compact readout of large CLYC scintillators with silicon photomultipler arrays

Compact readout of a large (5 x 5 x 5 cm 3) CLYC scintillator was demonstrated with a 8 x 8 array of 6mm silicon photomultipliers (SiPMs, specifically, a SensL ArrayJ-60035-64P) and an optimized amplification and summing circuit. Read out by the SiPM array, the crystal yielded an energy resolution of 5.5% at 662 keV and a figure of merit of 3.5, equivalent to the performance achieved with a 3-inch Hamamatsu R6233-100 PMT. To reduce channel count and avoid individual amplification of each SiPM in the array, the standard outputs of 16 SiPMs were passively summed then amplified. A current feedback amplifier was used for each channel to provide the required fast response time. The four amplified channels were then passively summed resulting in a single signal channel. A custom laboratory setup, based on the PSD8C ASIC, was used to capture the output and provide time-gated integration for PSD computation. We conclude the compact volume, low bias voltage, and reduced mass of the SiPM array readout are desirable for space and national security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗