Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cable inductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A new tubular ironless linear induction motor using non-interrupted winding method

The ironless linear induction motor device can be used for any application which requires a large motion span or rotation restrictedly by the ironless feature due to the strong magnetic field environment. One of the possible applications is ITER diagnostics shutters. The tokamak reactor systems have a severe radiation issue during the operation. The traditional Kapton-insulated wires have significantly lower radiation resistance than an expected large radiation dose at ITER Motion Stark Effect (MSE) shutter location. Furthermore, the traditional single-sided linear induction motor winds the wire to make the N-turn pitch coils independently and then connect them in series to make a one-phase winding. Therefore, it is a big challenge to make so many radiation-protection connectors in such a limited space as inside the vacuum vessel of fusion reactors. The approved mineral-insulated kinds of cables need a large bend radius for the end turns, so the traditional single-sided linear motor with two-layer three-phase windings need to be upgraded to the tubular linear motors. The new proposed tubular ironless linear induction motor can not only overcome the large bend radius issue with the mineral-insulated cables but also allow the motor coils wound continuously around the tubular-shaped stator, forward and backward N times to make a N-turn winding for each phase, in order to resolve the radiation protection issue with the winding connection. The 3D transient Maxwell electromagnetic model with a tubular three-phase linear induction motor has been analyzed. Furthermore, this paper will present the detailed design and winding method of ironless linear induction motor actuators, and results of the 3D transient numerical simulation of the actuator performance.

Ironless↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

Elliptic Aperture CCT Coils for HTS Dipole Magnets

High-temperature REBa$_{2}$Cu$_{3}$O$_{7-x}$ (REBCO) superconductors are a route to increase the field of accelerator magnets beyond the 15-16T practical limit of Nb$_{3}$Sn. REBCO cabled in a CORC geometry is a promising fit for this application, enabling the design of low inductance magnets with conductor transposition. However, the use of CORC in coils with the tight conductor bending radii typical of accelerator magnets remains a key challenge, with on-going research both on the conductor development and coil design fronts seeking to address this issue. Here, in this work we explore the tradeoffs between circular and elliptic aperture canted-cosine-theta (CCT) coils when the conductor minimum bending radius is a key consideration, concluding that aperture ellipticity is an important free parameter in the optimization of magnetically efficient CORC dipole magnets. In particular, we show that elliptic bore designs enable a regime of smaller aperture HTS coils, an important result for LTS-HTS hybrid magnets and more generally for accelerator applications benefiting from non-circular magnet apertures. To this end we present an elliptic aperture dipole design optimized for hybrid testing within the US Magnet Development Program (US-MDP) and share 77 K test results of a prototype coil which provides first experimental confirmation of the advantages.

Brouwer, L. [Lawrence Berkeley National Laboratory↗

Parasitic Effects in Impedance Spectrum of PEM Water Electrolysis Cells: Case Study of High-Frequency Inductive Effects

Electrochemical impedance spectroscopy (EIS) is a powerful tool to characterize and distinguish electrochemical, electrical, and diffusive processes in an electrolysis cell. The EIS response with small impedance (mΩ) depends on components and materials of the cell, but often also on the electrical setup, cables, and connectors, leading to incorrect conclusions about the performance of the electrolysis cells. These parasitic effects are assessed via a short-circuit measurement and confirmed to be external from the membrane electrode assembly (MEA). In the setup, the inductive characteristic is described by a modified inductive reactance and must be included in the equivalent circuit model (ECM) which is fitting the cell EIS spectra in operation (in situ). If points of the spectra showing inductive characteristic (below x-axis in Nyquist plot) are excluded from the ECM evaluation, an artificially increased ohmic resistance at high frequencies is obtained. In addition, considerations on other components of the ECM can be misleading and significantly incorrect. The only way to avoid that inductive behavior caused by the external setup is incorrectly assigned to the ECM describing properties of the MEA is to include the inductive effects in the ECM analysis of in situ EIS measurements.

30 DIRECT ENERGY CONVERSION↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflections

Flash radiography is a much used diagnostic technique for high-explosively driven hydrodynamic experiments. Two linear-induction electron accelerators (LIAs) at the Los Alamos Dual Axis Radiography of Hydrodynamic Tests (DARHT) facility provide the source spots for point projection radiography of exceptionally large and dense experiments. In these LIAs, the beam acceleration is provided by high-voltage pulses applied to a number of inductively isolated gaps. The high-voltage pulses are produced by remotely located pulsedpower generators and delivered to the gaps by long highvoltage cables. For Scorpius, these pulse generators are called line replacement units (LRUs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Preliminary Design of Ironless Linear Induction Motors for ITER MSE Shutter Actuators

In this article, the shutters need to be closed or opened during the operation and calibration period time for the fusion diagnostic systems, such as the International Thermonuclear Experimental Reactor (ITER) motional stark effect (MSE). Standard electric motors and actuators will not work in a strong magnetic field environment due to the presence of the magnetic field of fusion reactors. The innovative linear induction motor (LIM) with an ironless feature overcomes this kind of challenge and can be used for any application that requires controlled motion with a large stroke in the magnetic field environment. It consists of a high-electrical conductivity plate like copper and three-phase motor windings with nonferrous or stainless-steel stators. The conductor plate attached with the shutter is simply driven by the underneath three-phase linear windings to achieve linear motion. The motor drive can be controlled remotely by a controller using the electrical connection, so no sensitive electronic components are located in the harsh environment where the motor itself is located. The design requirements and test facility have been described. Several 3-D transient Maxwell electromagnetic (EM) models with different locations of three-phase linear motor windings and shutter stators have been analyzed and evolved to meet any applications allowed in the harsh environment inside the vacuum vessel of fusion reactors. The preliminary design results are presented in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-low radioactivity Kapton and copper-Kapton laminates

Polyimide-based materials, like Kapton, are widely used in flexible cables and circuitry due to their unique electrical and mechanical characteristics. This study is aimed at investigating the radiopurity of Kapton for use in ultralow background, rare-event physics applications by measuring the 238U, 232Th, and natK levels using inductively coupled plasma mass spectrometry. Commercial-off-the-shelf Kapton varieties, mea- sured at approximately 950 and 120 pg/g 238U and 232Th (1.2×104 and 490 µBq/kg), respectively, can be a significant background source for many current and next-generation ultralow background detectors. This study has found that the dominant contamination is due to the use of dicalcium phosphate (DCP), a nonessential slip additive added during manufacturing. Alternative Kapton materials were obtained that did not contain DCP and were determined to be significantly more radiopure than the commercially- available options with 12 and 19 pg/g 238U and 232Th (150 and 77 µBq/kg), respectively. The lowest radioactivity version produced (Kapton ELJ, which contains an adhesive) was found to contain single digit pg/g levels of 238U and 232Th, two-to-three orders of magnitude cleaner than commercial-off-the- shelf options. Moreover, copper-clad polyimide laminates employing Kapton ELJ as the insulator were obtained and measured and showed to be very radiopure at 8.6 and 22 pg/g 238U and 232Th (110 and 89 µBq/kg), respectively.

Arnquist, Isaac J.↗

Evaluation of Oxygen Consumption as a Sensitive Measure of Electrical Cable Polymer Insulation Degradation

Polymers used as dielectric materials in nuclear grade electrical cables, such as cross-linked polyethylene (XLPE) and ethylene-propylene rubber (EPR), are long-lived and durable. Estimating the decades-long useful service life of polymers experimentally in a feasible timeframe of weeks or months requires greatly accelerated aging in the laboratory at elevated temperatures and/or gamma dose rates. Many limitations of accelerated aging, such as due to artefacts of the process including diffusion limited oxidation and dose rate effects, have been identified that can make accurate lifetime prediction at service conditions challenging. This can be due to differences in degradation mechanisms between rapid and extended aging or to the presence of induction periods during which early aging is undetectable using common metrics of polymer insulation characterization such as tensile elongation at break. Conceptually, an ideal measure of aging would track clearly and predictably with material changes throughout the lifecycle of the evolving material state from early aging through end of useful life. With such a metric accelerated aging could be performed at much milder conditions, conditions closer to those found in long term service, and end of life calculated from the early data. Oxygen consumption has previously been proposed as a sensitive measure of insulation polymer oxidation that might meet such desirable characteristics. In this work, nuclear cable insulation samples of the two most common types, XLPE and EPR, from two of the most sourced manufacturers, RSCC and The Okonite Company, were subjected to gamma irradiation at dose rates of 100, 200, and 300 Gy/hr for up to 42 days at 26°C. The aged samples were used to evaluate oxygen consumption as a sensitive measure of aging for these materials and these conditions. For comparison and validation, the aged samples were also characterized using the more conventional tests of mass change, density, carbonyl index, and yellowness index. For both materials, oxygen consumption during irradiation was found to track consistently with applied dose—oxygen consumption rate was linear with time. Mass change and carbonyl index were also clearly proportional to exposure dose. Yellowness index, a surface sensitive measure, was observed to increase linearly with dose at low exposure levels before plateauing. Sample density was not observed to change under the conditions explored. Oxygen consumption was found to be a particularly sensitive metric to measure the degradation of polymeric cable insulation exposed to radiation. Oxygen consumption was compared to Arrhenius and time-temperature-superposition methods for activation energy calculation using literature date and found to be a useful and viable alternative for lifetime prediction. The techniques developed in this work are anticipated to be valuable in the estimation of insulation aging rates under mild conditions approaching service conditions. Direction comparison of useful life prediction by oxygen consumption with prediction via Arrhenius methodology for thermal aging and existing methods for radiation and combined thermal/radiation aging would serve to further validate this promising approach and refine our understanding of material-specific aging rates.

36 MATERIALS SCIENCE↗

Thermal aging effects on crosslinked polyethylene cable insulation with decabromodiphenyl ether flame retardant alternative

Decabromodiphenyl ether (decaBDE) has been extensively used as a flame retardant in several applications, including nuclear electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. The Environmental Protection Agency (EPA) published a regulation on January 6, 2021, aimed at phasing out the manufacturing, processing, and distribution of decaBDE. This rule set a compliance deadline of March 8, 2021, for the manufacture and processing of decaBDE, and an extended deadline of January 6, 2023, for specific applications including wire and cable insulation in nuclear power generation facilities. In response to such regulations, RSCC, a major supplier of safety-related electrical cables and associated products to the U.S. nuclear industry updated the formula of their crosslinked polyethylene (XLPE) insulation to replace the historically used decaBDE flame retardant with an acceptable alternative. This change from the previous decaBDE-containing XLPE prompted interest in comparative performance of the two material formulations, especially with respect to characteristics relevant to safety-related function such as thermal and radiation resistance. RSCC graciously provided samples of wire insulated with the decaBDE-containing XLPE formulation and corresponding wire insulated with XLPE of the new formulation, containing a decaBDE alternative. In this work we compare characteristics of the two formulations and a previously produced commercial version of the RSCC decaBDE-containing XLPE insulation subjected to thermal aging at 150 °C and 165 °C. The comparison was focused on mechanical durability, thermal stability in the oxidative environment, and chemical structures. Briefly, • Tensile elongation at break (EAB) results showed loss of mechanical elasticity with longer aging time, as expected. Aging time dependence of EAB did not differ between the decaBDE-containing and decaBDE-alternative samples. • Subtle differences between the two materials can be detected from Fourier-transform infrared spectroscopy (FTIR) absorbance spectra in the range below 1700 cm -1 , are assumed to be related to decomposition of flame retardant additives during thermal aging. • The oxidation induction time (OIT) data seemed to show that the unaged decaBDE-containing XLPE material is more thermally stable than the unaged decaBDE-alternative material, but the discrepancy in OIT decreased with aging time and the OIT values of the two materials became similar starting with the 4 th day of aging at 165 °C. This thermal aging investigation confirmed that the mechanical durability, a key property monitored for cable qualification, was not significantly affected by the modification of the formulation with a decaBDE alternative flame-retardant system in the investigated thermal aging conditions. Further studies on the same sets of materials exposed to thermal and gamma radiation aging would further inform comparison of the materials safety-related function.

36 MATERIALS SCIENCE↗

Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Booster cavity damper redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and is undergoing testing for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity’s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Booster Cavity Damper Redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Condition assessment of cable insulation materials in advanced reactor environments

While existing cable insulation materials are sufficient for use in the current reactor fleet, environmental conditions inside some advanced reactors, such as small modular reactors, will be substantially harsher. The work herein was conducted to assess the performance and overall survivability of several high-temperature, radiation resistant insulation polymers in a simulated small modular reactor environment. The materials evaluated under this research include polyether ether ketone, polyimide, and silicone rubber. These polymers were subjected to 1000 h of environmental stress exposure under two different conditions: 1) high temperature (i.e., 250 °C) in atmospheric pressure and 2) high temperature in a low-pressure vacuum (i.e., less than 2 psia). During the environmental exposure process, each insulation was periodically tested using several materials characterization techniques including Fourier transform infrared spectroscopy, oxidation induction time, and oxidation induction temperature. The objective of this testing was to assess and monitor changes that occurred in the thermal and chemical properties of the materials during the environmental exposures. The overall survivability of each insulation was assessed based on these property changes. The results of this research revealed that the polyimide and polyether ether ketone insulations had significantly better thermal and chemical stability than the silicone rubber during both the high-temperature atmospheric and vacuum exposures. Both polyimide and polyether ether ketone experienced minimal reductions in their chemical and thermal properties over the course of 1000 h in the simulated environments. Finally, based on this research, polyimide and polyether ether ketone show promise as potential base materials for small modular reactor cable insulation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗