Search NASA⌕ Search

SEARCH · Search NASA

Results for “Camera shutter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Processing Ocean Images to Detect Large Drift Nets

A computer program processes the digitized outputs of a set of downward-looking video cameras aboard an aircraft flying over the ocean. The purpose served by this software is to facilitate the detection of large drift nets that have been lost, abandoned, or jettisoned. The development of this software and of the associated imaging hardware is part of a larger effort to develop means of detecting and removing large drift nets before they cause further environmental damage to the ocean and to shores on which they sometimes impinge. The software is capable of near-realtime processing of as many as three video feeds at a rate of 30 frames per second. After a user sets the parameters of an adjustable algorithm, the software analyzes each video stream, detects any anomaly, issues a command to point a high-resolution camera toward the location of the anomaly, and, once the camera has been so aimed, issues a command to trigger the camera shutter. The resulting high-resolution image is digitized, and the resulting data are automatically uploaded to the operator s computer for analysis.

Veenstra, Tim↗

Distributed Vision Sensing of Small Uncrewed Aircraft Systems in Urban Traffic Corridors

The NASA Advanced Air Mobility mission will enable widespread low altitude passenger travel, cargo delivery, and a variety of public services through the development of Uncrewed Aerial Systems (UAS) operations. Ensuring safe, autonomous operations in densely populated environments requires careful consideration towards hazards including other aircraft, infrastructure, and evolving weather. Small Uncrewed Aerial Systems (SUAS) present a unique hazard to UAS operations as they share airspace and may be readily operated in a non-cooperative fashion. This work investigates distributed sensing of SUAS traversing an air traffic corridor in an urban setting. This work develops a distributed vision detect and track strategy at NASA Langley Research Center. Three nodes, each with at least one global shutter camera, are distributed around a traffic corridor to surveil flight operations for two SUAS performing low altitude flight operations. Each node is equipped with a GPS and cellular modem to enable timestamping and remote control of acquisition. Node one faces a traffic roundabout with buildings in the background and achieves 99% surveillance coverage for two SUAS against building and tree backgrounds at ranges 50 to 130m. The second node points down Langley Boulevard with trees and buildings in the background and achieves 99% coverage at separation distances between 70 and 180m. The analysis for the second node is limited to ranges below 180m due to low contrast against dark, tree backgrounds. Finally, the third node points down Langley Boulevard from another perspective and achieves 99% coverage at ranges 60m to 200m against mostly building with a few sections of trees in the background.

Chester V Dolph↗

Exposure interlock for oscilloscope cameras

An exposure interlock has been developed for oscilloscope cameras which cuts off ambient light from the oscilloscope screen before the shutter of the camera is tripped. A flap is provided which may be selectively positioned to an open position which enables viewing of the oscilloscope screen and a closed position which cuts off the oscilloscope screen from view and simultaneously cuts off ambient light from the oscilloscope screen. A mechanical interlock is provided between the flap to be activated to its closed position before the camera shutter is tripped, thereby preventing overexposure of the film.

Spitzer, C. R.↗

FPGA Control System for the Automated Test of Microshutters

The James Webb Space Telescope, scheduled to replace the Hubble in 2013, must simultaneously observe hundreds of faint galaxies. This requirement has led to the development of a programmable transmission mask which can be adapted to admit light with arbitrary pattern of galaxies into its spectrograph. This programmable mask will contain a large array of micro-electromechanical (MEMs) devices called MicroShutters. These microscopic shutters physically open and close like the shutter on a camera, except each shutter is microscopic in size and an array 365 by 171 is used to select the objects under spectroscopic observation at a given time, and to block the unwanted background light from other areas. NASA developed and is currently refining the exceptionally difficult process of manufacturing these shutters. This paper describes how the authors used LabVIEW FPGA and a reconfigurable I/O board to control the shutters in a test chamber and how the flexibility of the system allows us to continue to modify the control algorithms as NASA optimizes the performance of the MicroShutter arrays.

Lyness, Eric↗

FPGA Control System for the Automated Test of MicroShutters

The James Webb Space Telescope, scheduled to replace the Hubble in 2013, must simultaneously observe hundreds of faint galaxies. This requirement has led to the development of a programmable transmission mask which can be adapted to admit light from an arbitrary pattern of galaxies into its spectrograph. This programmable mask will contain a large array of micro-electromechanical (MEMs) devices called MicroShutters. These microscopic shutters physically open and close like the shutter on a camera, except each shutter is microscopic in size and an array 365 by 171 is used to select the objects under spectroscopic observation at a given time, and to block the unwanted background light from other areas. NASA developed and is currently refining the exceptionally difficult process of manufacturing these shutters. This paper describes how the authors used LabVIEW FPGA and a reconfigurable I/O board to control the shutters in a test chamber and how the flexibility of the system allows us to continue to modify the control algorithms as NASA optimizes the performance of the MicroShutter arrays.

Lyness, Eric↗

The IRAC Shutter Mechanism: Residual Magnetism and the Rotary Solenoid

The Infrared Array Camera (IRAC) Shutter mechanism was originally presented in the paper, 'A Low Power Cryogenic Shutter Mechanism for Use on Infrared Imagers' at the 34th Aerospace Mechanisms Symposium, May 2000. At that time, the shutter was believed to be performing flawlessly and there was every indication it would continue to do so. In early spring of 2001, the calibration shutter, a rotary solenoid designed to be fail-safe open, remained in a closed state with no power to the electromagnetic coils. The ensuing investigation, subsequent testing, proposed remedy, and lessons learned are the focus of this paper.

Schwinger, Scott↗

The NACA High-Speed Motion-Picture Camera Optical Compensation at 40,000 Photographs Per Second

The principle of operation of the NACA high-speed camera is completely explained. This camera, operating at the rate of 40,000 photographs per second, took the photographs presented in numerous NACA reports concerning combustion, preignition, and knock in the spark-ignition engine. Many design details are presented and discussed, details of an entirely conventional nature are omitted. The inherent aberrations of the camera are discussed and partly evaluated. The focal-plane-shutter effect of the camera is explained. Photographs of the camera are presented. Some high-speed motion pictures of familiar objects -- photoflash bulb, firecrackers, camera shutter -- are reproduced as an illustration of the quality of the photographs taken by the camera.

Miller, Cearcy D↗

Calibration of 2-D soil zymography for correct analysis of enzyme distribution

Soil zymography is a new technique developed to visualize two-dimensional distributions of enzyme activities. The method is composed of incubating a membrane saturated with an enzyme-specific fluorogenic substrate on a surface of the soil sample, followed by recording the membrane image generated by a fluorescent product (e.g. MUF: methylumbelliferone) in ultraviolet light. Despite its relative ease of use, performing zymography involves multiple user-made decisions that might affect the accuracy of enzyme activity estimates. Thus, unification of the zymography methodology is required for correct estimations and comparisons of various studies. We investigated the following methodological aspects of the implementation of zymography: (a) camera settings and image processing, (b) effects of evaporation and (c) calibration procedures. Camera settings (shutter speeds or exposure time) affected the intensity of background fluorescence and signal-to-noise ratios (SNR). However, because their combined effects varied depending on MUF concentrations, light and camera setting need to be optimized for the expected range of MUF concentrations prior to zymography. Evaporation of MUF solution from the membrane had no effect on fluorescence. Relations between MUF concentration and intensity of fluorescence during calibrations demonstrated a saturated pattern and were strongly affected by image noise outside the optimal range (e.g. 8–14 μm MUF pixel -1 ). We developed a new calibration approach that is based on a piecewise linear regression. The new approach accounted for specific ranges of MUF concentration and uses nonuniformly saturated membranes, reflecting the real distribution of enzyme activities in soil. The new calibration algorithm eliminated biases of the standard calibration and resulted in greater accuracy in predicting MUF concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Ground Calibration of the Helioseismic and Magnetic Imager (HMI) Instrument on the Solar Dynamics Observatory (SDO)

The Helioseismic and Magnetic Imager (HMI) investigation will study the solar interior using helioseismic techniques as well as the magnetic field near the solar surface. The HMI instrument is part of the Solar Dynamics Observatory (SDO) that was launched on 11 February 2010. The instrument is designed to measure the Doppler shift, intensity, and vector magnetic field at the solar photosphere using the 6173 Fe I absorption line. The instrument consists of a front-window filter, a telescope, a set of wave plates for polarimetry, an image-stabilization system, a blocking filter, a five-stage Lyot filter with one tunable element, two wide-field tunable Michelson interferometers, a pair of 4096(exo 2) pixel cameras with independent shutters, and associated electronics. Each camera takes a full-disk image roughly every 3.75 seconds giving an overall cadence of 45 seconds for the Doppler, intensity, and line-of-sight magnetic-field measurements and a slower cadence for the full vector magnetic field. This article describes the design of the HMI instrument and provides an overview of the pre-launch calibration efforts. Overviews of the investigation, details of the calibrations, data handling, and the science analysis are provided in accompanying articles.

magnetic field↗

Solid-state wide-range low power camera timer for space applications

This paper describes a device for timing sequentially 8 film exposures of a rocket-borne camera with a time interval between each exposure to allow the camera film transport mechanism to step the film from one frame to the next after each exposure. Each exposure time can be independently adjusted from a a fraction of a second to several hundred seconds by changing the value of a timing resistor and/or capacitor. All of the rocket interface circuits have ben designed to minimize the coupling of spurious noise signals into the timer.

Solid state device↗

Laser Measurement Of Convective-Heat-Transfer Coefficient

Coefficient of convective transfer of heat at spot on surface of wind-tunnel model computed from measurements acquired by developmental laser-induced-heat-flux technique. Enables non-intrusive measurements of convective-heat-transfer coefficients at many points across surfaces of models in complicated, three-dimensional, high-speed flows. Measurement spot scanned across surface of model. Apparatus includes argon-ion laser, attenuator/beam splitter electronic shutter infrared camera, and subsystem.

Porro, A. Robert↗

A Low Power Cryogenic Shutter Mechanism for Use in Infrared Imagers

This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

Schwinger, D. Scott↗

A Low Power Cryogenic Shutter Mechanism for use in Infrared Images

This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

Schwinger, D. Scott↗