Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity fade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Role of Manganese Deposition on Graphite in the Capacity Fading of Lithium Ion Batteries

Lithium-ion batteries utilizing manganese based cathodes have received considerable interest in recent years for their lower cost and favorable environmental friendliness relative to their cobalt counterparts. However, Li-ion batteries using manganese based cathodes and graphite anodes suffer from severe capacity fading at higher operating temperature. In this article, we report on an astute investigation into how the dissolution of manganese impacts the capacity fading within the Li-ion batteries. Our investigation reveals that the manganese dissolves from the cathode, transports to the graphite electrode, and deposits onto the outer surface of the inner most solid electrolyte interphase (SEI) layer which is known to be a mixture of inorganic salts (e.g. Li2CO3, LiF, and Li2O). In this location, the manganese facilitates the reduction of the electrolyte and the subsequent formation of lithium containing products on the graphite which removes lithium ions from the normal operation of the cell and thereby induces the severe capacity fade.

Environmental Molecular Sciences Laboratory↗

Understanding capacity fade in organic redox-flow batteries by combining spectroscopy with statistical inference techniques

Organic redox-active molecules are attractive as redox-flow battery (RFB) reactants because of their low anticipated costs and widely tunable properties. Unfortunately, many lab-scale flow cells experience rapid material degradation (from chemical and electrochemical decay mechanisms) and capacity fade during cycling (>0.1%/day) hindering their commercial deployment. In this work, we combine ultraviolet-visible spectrophotometry and statistical inference techniques to elucidate the Michael attack decay mechanism for 4,5-dihydroxy-1,3-benzenedisulfonic acid (BQDS), a once-promising positive electrolyte reactant for aqueous organic redox-flow batteries. We use Bayesian inference and multivariate curve resolution on the spectroscopic data to derive uncertainty-quantified reaction orders and rates for Michael attack, estimate the spectra of intermediate species and establish a quantitative connection between molecular decay and capacity fade. Our work illustrates the promise of using statistical inference to elucidate chemical and electrochemical mechanisms of capacity fade in organic redox-flow battery together with uncertainty quantification, in flow cell-based electrochemical systems.

25 ENERGY STORAGE↗

Impact of Charge Voltage on Factors Influencing Capacity Fade in Layered NMC622: Multimodal X-ray and Electrochemical Characterization

Ni-rich NMC is an attractive Li-ion battery cathode due to its combination of energy density, thermal stability, and reversibility. While higher delivered energy density can be achieved with a more positive charge voltage limit, this approach compromises sustained reversibility. Improved understanding of the local and bulk structural transformations as a function of charge voltage, and their associated impacts on capacity fade are critically needed. Through simultaneous operando synchrotron X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) of cells cycled at 3–4.3 or 3–4.7 V, this study presents an in-depth investigation into the effects of voltage window on local coordination, bulk structure, and oxidation state. These measurements are complemented by ex situ X-ray fluorescence (XRF) mapping and scanning electrochemical microscopy mapping (SECM) of the negative electrode, X-ray photoelectron spectroscopy (XPS) of the positive electrode, and cell level electrochemical impedance spectroscopy (EIS). Initially, cycling between 3 and 4.7 V leads to greater delivered capacity due to greater lithium extraction, accompanied by increased structural distortion, moderately higher Ni oxidation, and substantially higher Co oxidation. Continued cycling at this high voltage results in suppressed Ni and Co redox, greater structural distortion, increased levels of transition metal dissolution, higher cell impedance, and 3× greater capacity fade.

capacity fading mechanisms↗

A High Potential, Low Capacity Fade Rate Iron Complex Posolyte for Aqueous Organic Flow Batteries

An iron complex, tris(4,4'-bis(hydroxymethyl)-2,2'-bipyridine) iron dichloride is reported, which operates at near-neutral pH with a redox potential of 0.985 V versus SHE. This high potential compound is employed in the posolyte of an aqueous flow battery, paired with bis(3-trimethylammonio)propyl viologen tetrachloride in the negolyte, exhibiting an open-circuit voltage of 1.3 V at near-neutral pH. It demonstrates excellent cycling performance with a low temporal capacity fade rate of 0.07% per day over 35 days of cycling. The extended cycling lifetime is the result of low permeability and improved structural stability of the newly developed iron complex compared to that of the iron tris(bipyridine) complex. The combination of high redox potential and low capacity fade rate compares favorably with those of all previously demonstrated organic and organometallic aqueous posolytes. Extensive investigation into the possible degradation mechanisms, including post-mortem chemical and electrochemical analyses, indicates that stepwise ligand dissociations of the iron complex are responsible for the reported capacity loss during cell cycling. Further, this investigation provides unprecedented insight to guide further improvements of such metalorganic compounds for energy storage and conversion applications.

25 ENERGY STORAGE↗

Evaluating capacity fade in dual insertion batteries using potential and temperature measurements

Methods and systems are described of managing a battery system. The battery system including at least one battery cell and one or more sensors configured to measure a temperature of the at least one battery cell. The method includes receiving a measurement of the temperature of the at least one battery cell, estimating an open circuit potential of the at least one battery cell, estimating a capacity fade of the at least one battery cell based on the open circuit potential of the at least one battery cell and a ratio of a change in the open circuit potential relative to a change in the temperature of the at least one battery cell, and regulating at least one of charging or discharging of the at least one battery cell based on the estimation of the capacity fade.

Christensen, John F.↗

Evaluating capacity fade in dual insertion batteries using potential and temperature measurements

Methods and systems are described of managing a battery system. The battery system including at least one battery cell and one or more sensors configured to measure a temperature of the at least one battery cell. The method includes receiving a measurement of the temperature of the at least one battery cell, estimating an open circuit potential of the at least one battery cell, estimating a capacity fade of the at least one battery cell based on the open circuit potential of the at least one battery cell and a ratio of a change in the open circuit potential relative to a change in the temperature of the at least one battery cell, and regulating at least one of charging or discharging of the at least one battery cell based on the estimation of the capacity fade.

Christensen, John F.↗

Critical Evaluation of Potentiostatic Holds as Accelerated Predictors of Capacity Fade during Calendar Aging

Li-ion batteries will lose both capacity and power over time due to calendar aging caused by slow parasitic processes that consume Li + ions. Studying and mitigating these processes is traditionally an equally slow venture, which is especially taxing for the validation of new active materials and electrolyte additives. Here, we evaluate whether potentiostatic holds can be used to accelerate the diagnosis of Li + loss during calendar aging. The technique is based on the idea that, under the right conditions, the current measured as the cell voltage is held constant can be correlated with the instantaneous rate of side reactions. Thus, in principle, these measurements could capture the rate of capacity fade in real time . In practice, we show that this method is incapable of quantitatively forecasting calendar aging trends. Instead, our study demonstrates that potentiostatic holds can be applied for initial qualitative screening of systems that exhibit promising long-term stability, which can be useful to shrink the parameter space for calendar aging studies. By facilitating the identification of improved formulations, this approach can help accelerate innovation in the battery industry.

25 ENERGY STORAGE↗

Insight into the Capacity Fading Mechanism of Amorphous Se 2 S 5 Confined in Micro/Mesoporous Carbon Matrix in Ether-Based Electrolytes

In contrast to the stable cycle performance of space confined Se-based cathodes for lithium batteries in carbonate-based electrolytes, their common capacity fading in ether-based electrolytes has been paid less attention and not yet well-addressed so far. In this work, the lithiation/delithiation of amorphous Se2S5 confined in micro/mesoporous carbon (Se2S5/MPC) cathode was investigated by in situ X-ray near edge absorption spectroscopy (XANES) and theoretical calculations. The Se2S5/MPC composite was synthesized by a modified vaporization-condensation method to ensure a good encapsulation of Se2S5 into the pores of MPC host. In situ XANES results illustrated that the lithiation/delithiation reversibility of Se component was gradually decreased in ether-based electrolytes, leading to an aggravated formation of long-chain polyselenides during cycling and further capacity decay. Moreover, ab initio calculations revealed that the binding energy of polyselenides (Li2Sen) with carbon host is in an order of Li2Se6 > Li2Se4 > Li2Se. The insights into the failure mechanism of Se-based cathode gain in this work are expected to serve as a guide for future design on high performance Se-based cathodes.

ab initio calculations↗

Effects of the mode of storage on the capacity fading of the sintered nickel electrodes

A systematic investigation of the effect of temperature and two conditions of storage, shortened and open circuit, on the capacity fading of sintered nickel electrodes in NiCd batteries was conducted. All testing was done on sintered electrodes in flooded cells. Cycling tests to measure the capacity were performed at room temperature. The capacity out to one volt, a capacity useful for satellite applications. Test results indicated that: the shortened electrode showed a higher rate of loss than the open circuit electrodes; there was an increase in both modes with an increase in temperature; there was a loss of capacity with time of storage; a general degradation was observed as a function of time; shortened electrodes showed a higher end of charge than the open circuit ones; and at room temperature there was a lower loss in the open circuit electrode than in the shortened one.

Vyes, B.↗

Battery Capacity Fading Estimation Using a Force-Based Incremental Capacity Analysis

Traditionally health monitoring techniques in lithium-ion batteries rely on voltage and current measurements. A novel method of using a mechanical rather than electrical signal in the incremental capacity analysis (ICA) method is introduced in this paper. This method derives the incremental capacity curves based onmeasured force (ICF) instead of voltage (ICV). The force ismeasured on the surface of a cell under compression in a fixture that replicates a battery pack assembly and preloading. The analysis is performed on data collected from cycling encased prismatic Lithium-ion Nickel-Manganese-Cobalt Oxide (NMC) cells. For the NMC chemistry, the ICF method can complement or replace the ICV method for the following reasons. The identified ICV peaks are centered around 40% of state of charge (SOC) while the peaks of the ICF method are centered around 70% of SOC indicating that the ICF can be used more often because it is more likely that an electric vehicle (EV) or a plug-in hybrid electric vehicle (PHEV) will traverse the 70% SOC range than the 40% SOC. In addition the Signal to Noise ratio (SNR) of the force signal is four times larger than the voltage signal using laboratory grade sensors. The proposed ICF method is shown to achieve 0.42% accuracy in capacity estimation during a low C-rate constant current discharge. Future work will investigate the application of the capacity estimation technique under charging and operation under high C-rates by addressing the transient behavior of force so that an online methodology for capacity estimation is developed.

25 ENERGY STORAGE↗

NiH2 capacity fade during early cycling

Tests were conducted on nickel hydrogen batteries to determine the charge efficiency of the nickel electrode as a function of rate and temperature, cell discharge capacity, and capacity fade. Test procedures and results are presented in outline and graphic form.

Zagrodnik, Jeffrey P.↗

Capacity Fade of Graphite/NMC811: Influence of Particle Morphology, Electrolyte, and Charge Voltage

LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) is an important Li-ion battery cathode material; however, there is a tradeoff between delivered capacity and capacity retention. As the charge potential increases the capacity rises but at the expense of capacity retention. The decrease in capacity retention has been ascribed to several factors including particle cracking, surface reconstruction, transition metal dissolution, and electrolyte reactivity. The present study compares 4.1 and 4.3 V charging limits in commercially relevant graphite/NMC811 pouch cells for single crystal (SC) and polycrystalline (PC) NMC811 with ethylene carbonate (EC)-containing or EC-free electrolytes. The electrochemistry is rationalized through analysis of electrochemical impedance spectroscopy, positive electrode X-ray photoelectron spectroscopy, soft X-ray absorption spectroscopy, X-ray diffraction, and negative electrode mapping by X-ray fluorescence. Graphite/SC-NMC811 cells show high-capacity retention at 4.1 V but exhibit degradation at 4.3 V charging potentials. The EC-free electrolyte cells led to higher capacity fade, especially when charged to 4.3 V. Cathode dissolution and deposition on the negative electrode from PC-NMC811 cells was higher than for samples from SC-NMC811 cells. This study reveals the impact of material type, charge voltage, and electrolyte composition on the reactions at the positive electrode, their influence on the negative electrode, and evolution with cycle number.

36 MATERIALS SCIENCE↗

A Quantitative Failure Analysis on Capacity Fade in Rechargeable Lithium Metal Cells

Rechargeable lithium battery (RLB) technology is transforming portable devices, vehicle electrification, and grid modernization. To make RLB durable, reliable and safe, conducting failure mode and effect analysis (FMEA) to identify failure mechanism under the operating conditions is very desirable. However, this ability is often overlooked or even lacking. The failure analysis (FA) is often conducted by laboratory testing and postmortem analysis, and the knowledge typically empirical. Here we present a quantitative approach for FMEA that can reveal how failure modes and effects reduce the capacity of a RLB. This approach is based on the state of the battery for FMEA, contrary to the conventional approach based on operating or testing conditions. The key aspect of this FMEA method is to convert the experimental results to a state-of-charge (SOC)-based analytic methodology. Such a conversion can separate the thermodynamic and kinetic attributes of capacity fade based on compositional correspondence in the electrode, so the loss and the decreased utilization of the active materials can be determined respectively.

25 ENERGY STORAGE↗

Elucidating Instabilities Contributing to Capacity Fade in Bipyridine‐Based Materials for Non‐aqueous Flow Batteries

Abstract Metal‐based non‐aqueous redox flow batteries have the potential for long‐term energy storage if stability requirements can be achieved. One such stability issue in metal coordination complexes arises from ligand shedding in the anolyte upon reduction. Recognizing that the free ligands are relatively more stable than the metal coordination complex under highly reducing conditions, we evaluated a family of metal‐free bipyridinium materials as flow battery anolytes with the corresponding iron coordination complex as the catholyte. Bipyridinium compounds were functionalized for increased electrochemical stability, cycled in flow cells to understand efficiencies, and analyzed for degradation products. Methylation of the bipyridine nitrogens increased electrochemical stability yet left the reduced molecule susceptible to radical‐induced bond cleavage. Subsequent functionalization of bipyridine with carbomethoxy groups resulted in good battery performance with 96 % Coulombic and 90 % voltage efficiency, and improved cycling stability over a methoxy‐substituted anolyte with 14 % vs 36 % capacity fade in the first charge‐discharge cycle.

Kolesnichenko, Claudina X.↗

Underlying limitations behind impedance rise and capacity fade of single crystalline Ni-rich cathodes synthesized via a molten-salt route

Layered oxide LiNi x Mn y Co z O 2 (NMC) cathodes are often synthesized as polycrystalline secondary particles. Due to intergranular fracture stemming from volume changes of randomly oriented primary particles during charge/discharge, the synthesis of larger single-crystalline cathodes is of high interest. In this work, molten salt assisted growth of micron-sized Ni-rich crystals is achieved with excellent crystallinity, low cation mixing, and negligible impurities. However, electrochemical performance is compromised by high surface reactivity resulting in decomposition of electrolyte and subsequent formation of a thick CEI layer. While intergranular fracture is eliminated, planar gliding and severe intragranular fracture along the (003) plane occurs in the high voltage region within the first few cycles and is associated primarily with H2 to H3 structural transitions. In addition, H2 to H3 transitions are highly irreversible with cyclic voltammograms revealing polarization growth within <5 cycles. Subsequently, the single-crystalline material exhibited markedly reduced available capacity and enhanced capacity fade from sharp impedance growth compared to its polycrystalline counterpart. Here, this work furthers a fundamental understanding into the limitations of single-crystalline Ni-rich cathodes, and the obstacles limiting the advantages offered by the single-crystalline morphology.

25 ENERGY STORAGE↗

The Importance of a Moving Boundary Approach for Modeling the SEI Layer Growth to Predict Capacity Fade

One of the contributing factors to the aging of lithium-ion batteries is the growth of the solid-electrolyte interphase (SEI) layer. The growth of the SEI layer leads to the irreversible loss of lithium available for cycling and increases the resistance of the battery. Physics-based models in literature model the kinetically limited or solvent diffusion-limited growth. In such models, the interface resistance is a constant, and the contribution to the overpotential of the intercalation reaction from the SEI layer is considered to be ohmic. In this study, we propose a model that describes the growth of the SEI layer on the electrode surface as a moving interface. The transport of lithium ions and the solvent in the electrolyte are affected by this moving interface. The equations that govern the species transport and the potential drop across the SEI layer are derived from dilute solution theory and solved by transforming the coordinates of the moving boundary. The ion transport induces changes in the conductivity across the SEI layer, which affects the potential drop that arises due to its growth. The effects of this potential on capacity fade are studied over cycling the battery.

25 ENERGY STORAGE↗

Mechanisms for capacity fading in the NiH2 cell and its effects on cycle life

During recent years there have been a number of instances where the capacity of nickel hydrogen battery cells has proven to be unstable during storage. The capacity losses seen after periods of cell or battery storage have typically varied from only a small amount of fading, up to about 30 percent of the total cell capacity. Detailed studies into the root causes for such fading have been carried out in a number of instances. This report provides an overview of the different mechanisms that have been found to be responsible for such capacity fading in nickel hydrogen cells, and summarizes the presently available data on how each responsible mechanism affects ultimate cell cycle life.

Zimmerman, Albert H.↗