Search NASA⌕ Search

SEARCH · Search NASA

Results for “Central Receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects [Slides]

Develop a Design Basis Document / Owner’s Technical Specification for nitrate salt systems in commercial parabolic trough and central receiver projects. A Design Basis Document is to a project what a heat exchanger specification is to a heat exchanger, Extensive commercial experience in salt equipment and system design, much of it gained through mistakes and associated expenses. Distill the successful experience with nitrate salt systems from as many commercial projects as possible. Starting from 7 historical Design Basis Documents, compile a consensus description of commercial equipment and system designs.

14 SOLAR ENERGY↗

Damage modeling of power tower receiver tubes using the SRLIFE tool

Concentrating Solar Power (CSP) molten-salt central receivers are subject to high, transient incident flux during daily operation. The resulting creep-fatigue damage impacts the receiver’s reliability and restricts the permissible incident flux distribution for a given receiver. This paper aims to reduce CSP plants’ levelized cost of electricity by developing a methodology to predict lifetime and identifies the primary damage mechanism (creep vs fatigue) for any given fluid temperature and temperature gradient. Results are presented in the form of a damage map that serves as a valuable operation guide and design tool. Damage maps can be used to reduce maintenance costs by improving reliability and reduce receiver capital costs by better utilizing the receiver area. FEA simulation and damage modeling of tubes subject to asymmetrical flux conditions is performed in the open-source receiver design tool srlife. Parametric studies are performed over a range of inner tube temperatures and thermal gradients for A230, 316H, 740H, A282, A617, and 800H high temperature alloys. Damage maps are presented for each alloy. A parametric, FEA-based methodology is presented for comparison of fatigue-creep ratios and prediction of tube lifetime based on the critical thermal operating conditions. Fatigue is found to be negligible compared to creep for almost every case. Here, this finding suggests that fatigue effects associated with cloud events are insignificant compared to creep at these high temperature operating conditions. Additionally, lifetime predictions identify thermal conditions where small changes in operating conditions can result in large changes in predicted lifetime.

14 SOLAR ENERGY↗

High Flux Microchannel Receiver Development (Final Report)

The opportunity addressed in this project was using microscale heat exchanger technology for improving solar thermal central receiver efficiency. This will result in smaller, less expensive components and reduce the levelized cost of electricity from concentrated solar thermal power. This micro-pin solar receiver (MSR) directly heats high pressure (25 MPa) supercritical carbon dioxide (sCO 2 ) from 550°C to 720°C with an incident flux of at least 120 W/cm 2 at a receiver efficiency of >90% (assuming availability of 95% absorptivity coating), and receiver cost target of less than $\$$150/kWt. Realization of the MSR required an understanding of thermal hydraulic performance of sCO 2 in micro-pin passages, mechanical behavior of high nickel alloys at high temperatures including joints, advanced fabrication methods of high nickel alloys (etching, machining, brazing, welding, diffusion bonding), and the cost implications of these when the concept is scaled to production volumes. The technology can be used with gases (sCO 2 , helium, etc.) or with liquids such as molten salt or liquid metal. Given the high pressure associated with sCO 2 , its use demonstrates a “worst case” scenario, and the successful development of the MSR for this application will result in the development of a technology also applicable to a range of other heat transfer fluids that will enable next generation CSP plants, including support of the Gen3CSP program.

14 SOLAR ENERGY↗

On-Sun Testing of a High-Temperature Solar Receiver's Flux Distribution

Concentrated solar power (CSP) is a promising technology in transitioning to renewable energy because of its abundance in nature and thermal energy storage (TES) capability. Among the four types of available CSP technology, including parabolic trough, linear Fresnel, power tower, and parabolic dishes, a power tower using a central receiver has more potential to generate high-temperature heat in a scale supporting power cycles efficiency and achieve low levelized cost of energy (LCOE). Other than the conventional type of receiver design, the high-absorptive receiver concept developed and presented in this paper is novel in its design approach. The novel receiver design originated from National Renewable Energy Laboratory (NREL) consists of an array of solar flux absorb tubes. The solar absorb tubes require uniform flux distribution and in-depth flux penetration through the three different reflective sections of tubes in a hexagonal shape. To evaluate this unique receiver design and thermal performance, the flux distribution, flux uniformity, and intensity were numerically simulated using ansys fluent and SolTrace modeling program. On-sun testing has been done at NREL high flux solar testing facility, based on the computational analysis.

clean energy↗

Real-time dispatch optimization for concentrating solar power with thermal energy storage

Concentrating solar power (CSP) plants present a promising path towards utility-scale renewable energy. The power tower, or central receiver, configuration can achieve higher operating temperatures than other forms of CSP, and, like all forms of CSP, naturally pairs with comparatively inexpensive thermal energy storage, which allows CSP plants to dispatch electricity according to market price incentives and outside the hours of solar resource availability. Currently, CSP plants commonly include a steam Rankine power cycle and several heat exchange components to generate high-pressure steam using stored thermal energy. The efficiency of the steam Rankine cycle depends on the temperature of the plant's operating fluid, and so is a main concern of plant operators. However, the variable nature of the solar resource and the conservatism with which the receiver is operated prevent perfect control over the receiver outlet temperature. Therefore, during periods of solar variability, collection occurs at lower-than-design temperature. To support operator decisions in a real-time setting, we develop a revenue-maximizing non-convex mixed-integer, quadradically-constrained program which determines a dispatch schedule with sub-hourly time fidelity and considers temperature-dependent power cycle efficiency. The exact nonlinear formulation proves intractable for real-time decision support. Here we present exact and inexact techniques to improve problem tractability that include a hybrid nonlinear and linear formulation. Our approach admits solutions within approximately 3% of optimality, on average, within a five-minute time limit, demonstrating its usability for decision support in a real-time setting.

14 SOLAR ENERGY↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗

Estimating value of information for heliostat washing operations at solar thermal plants

Concentrating solar power (CSP) plants depend on thousands of heliostats whose reflectance declines as dust accumulates. Operators routinely measure reflectance to estimate soiling and, in turn, inform cleaning schedules, but the value of collecting more frequent or more accurate data has not been formally quantified. This study introduces a Monte Carlo discrete event simulation framework that integrates stochastic models of soiling, weather, and measurement error with a dynamic cleaning dispatch policy to estimate annual energy production and operations costs. Applied to two representative central-receiver field configurations, the results show that both the frequency and accuracy of reflectance measurements can meaningfully impact plant performance. In both case studies, reducing measurement intervals yields significant returns, with the energy gains greatly exceeding the cost of more frequent data collection. The simulation framework serves as a decision-support tool for CSP operators, allowing them to input site-specific soiling conditions, measurement accuracy, and survey frequency to evaluate the tradeoffs between data collection cost and energy recovery, and to identify measurement strategies that maximize plant profit.

14 SOLAR ENERGY↗

CuCr 2 O 4 particle growth and evolution across sol–gel routes and calcination profiles

CuCr 2 O 4 spinel is a candidate coating material for central receivers in concentrating solar power to protect structural alloys against high temperature oxidation and related degradation. Coating performance and microstructure of dip-coated and sintered coatings is dictated by the initial particle size of the CuCr 2 O 4 and sintering temperature, but can be compromised by particle agglomeration. Here in this study, sub-micron particles were synthesised through the Pechini and modified Pechini sol–gel methods. Phase composition was confirmed via X-ray diffraction. Particle growth during calcination of the nanoparticles at different temperatures (650°C, 750°C, 850°C) and times (between 1 and 24 h) was measured via laser diffraction and scanning electron microscopy. The modified Pechini method displayed evidence of smaller particle sizes and greater agglomeration. The kinetics of particle growth observed are consistent with a diffusion limited inhibited grain growth model.

36 MATERIALS SCIENCE↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

Case Studies and Parametric Analysis of Heliostat Performance With a Tradeoff-Informed Technoeconomic Analysis Metric

The Heliostat Consortium (HelioCon) was launched in 2021 to advance heliostat technology. Here this work presents a collection of baseline case studies for the technoeconomic analysis (TEA) of candidate heliostat improvements for concentrating solar power (CSP) and concentrated solar thermal (CST) systems that employ central receivers. The case studies we develop include a large-scale CSP plant, a smaller, modular CSP plant, and a small CST plant used for industrial process heat. In this work, we also propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. Finally, we perform a parametric analysis to show the impact of candidate technologies on the levelized cost of heat and, by extension, equivalent breakeven installed cost.

14 SOLAR ENERGY↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

An Uncertainty-Informed and High-Fidelity Performance Forecasting Framework for Heliostat Fields

Concentrating Solar Thermal (CST) tower systems employ heliostat fields to direct solar energy to a central receiver, which then transfers the heat either directly to a thermal process (e.g., steam production) or to a thermal energy storage system for future use. Heliostat fields compose a significant proportion of the project costs of a CST tower system and the performance of the heliostats determines a plant's productivity at a given location. While CST characterization tools such as SolarPILOT and System Advisor Model (SAM) include a large collection of inputs that influence the performance of a CST tower system, many are uncertain prior to the development of the project and may have a significant impact on the overall energy delivery and profitability of a project; moreover, the fidelity of these models under default conditions may be insufficient to determine the value of component improvements such as those under development in the Heliostat Consortium. This work introduces a Monte Carlo simulation framework that incorporates uncertainty in key performance parameters to generate confidence intervals and percentile estimates for a CST solar field's energy delivery.

14 SOLAR ENERGY↗

Characterizing the Impact of Heliostat Size, Focus Method, and Optical Error on Concentrating Solar Tower Systems

Concentrating Solar Power (CSP) tower systems use heliostat fields to direct solar energy to a central receiver. The efficiency of the heliostat field is crucial for achieving thermal generation targets and is also the largest cost component, making up 30-40% of total project costs. Developers face a tradeoff: reducing heliostat costs may decrease optical performance and increase land use, while improving performance could raise manufacturing costs (through higher precision). The optimal design depends on land, labor, and manufacturing costs. Additionally, inherent performance limitations exist - optical errors result in larger solar images as heliostats move farther from the receiver, increasing spillage and attenuation losses. Ultimately, there exists a point where receiver design power can no longer be achieved at design conditions for a given solar field area. This point depends on key heliostat field design parameters including field layout, heliostats size, focus method, and heliostat optical error. In this work, we explore and characterize the performance trade-offs between heliostat size, focus method, and optical error using Monte Carlo ray-tracing simulations using NREL's high performance computing resources. The goal of this fundamental investigation is to understand practical heliostat design performance impacts that can be used to produce more cost-effective heliostat fields while still achieving plant thermal generation targets.

14 SOLAR ENERGY↗

Incidence and predictors of loss to follow-up among adult patients receiving antiretroviral therapy in Central Ethiopia: a multi-center retrospective cohort study

Background: Globally, loss to follow-up (LTFU) remains a significant public health concern despite the rapid expansion of antiretroviral medication programs. It is a significant cause of treatment failure and threatens the enhancement of HIV treatment outcomes among patients on antiretroviral therapy (ART). However, there is a paucity of evidence on its incidence and predictors in Ethiopia. Thus, this study aimed to examine the incidence and predictors of LTFU among adult HIV patients receiving ART at hospitals in Central Ethiopia. Methods: A multi-centered facility-based retrospective cohort study was conducted among 432 randomly selected adult patients who received antiretroviral therapy. Data were entered into EpiData version 3.1 and exported to Stata version 14 for analysis. The Kaplan–Meier failure function was employed to determine the overall failure estimates, and the log-rank test was used to compare the probability of failure among the different categories of variables. The Cox proportional hazard model was used to identify independent predictors of LTFU. Results: Overall, 172 (39.8%) study participants were lost to follow-up over the 10-year follow-up period with an incidence rate of 8.12 (95% CI: 7.11, 9.09) per 1,000 person-months. Undisclosed HIV status (AHR: 1.96, 95% CI: 1.14, 3.36), not able to work (AHR: 1.84, 95% CI: 1.13, 2.22), opportunistic infections (AHR: 3.13, 95% CI: 2.17, 4.52), CD4 < 200 cell/mL (AHR: 1.95, 95% CI: 1.18, 3.21), not receiving isoniazid preventive therapy (IPT) (AHR: 2.57, 95% CI: 1.62, 4.06), not participating in clubs (AHR: 1.68, 95% CI: 1.10, 2.22), side effects of drugs (AHR: 1.44, 95% CI: 1.02, 2.04), and high viral load (AHR: 3.15, 95% CI: 1.81, 5.47) were identified as significant predictors of loss to follow-up. Conclusion: In this study, the incidence of LTFU was high. The focus should be on creating awareness and prevention programs that aim to reduce loss to follow-up by continuing counseling, especially on the negative effects of loss to follow-up and the benefits of ART care.

60 APPLIED LIFE SCIENCES↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗