Search NASA⌕ Search

SEARCH · Search NASA

Results for “Characteristic Curves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improved instrumental magnitude prediction expected from version 2 of the NASA SKY2000 master star catalog

The SKY2000 Master Star Catalog (MC), Version 2 and its predecessors have been designed to provide the basic astronomical input data needed for satellite acquisition and attitude determination on NASA spacecraft. Stellar positions and proper motions are the primary MC data required for operations support followed closely by the stellar brightness observed in various standard astronomical passbands. The instrumental red-magnitude prediction subsystem (REDMAG) in the MMSCAT software package computes the expected instrumental color index (CI) [sensor color correction] from an observed astronomical stellar magnitude in the MC and the characteristics of the stellar spectrum, astronomical passband, and sensor sensitivity curve. The computation is more error prone the greater the mismatch of the sensor sensitivity curve characteristics and those of the observed astronomical passbands. This paper presents the preliminary performance analysis of a typical red-sensitive CCDST during acquisition of sensor data from the two Ball CT-601 ST's onboard the Rossi X-Ray Timing Explorer (RXTE). A comparison is made of relative star positions measured in the ST FOV coordinate system with the expected results computed from the recently released Tycho Catalogue. The comparison is repeated for a group of observed stars with nearby, bright neighbors in order to determine the tracker behavior in the presence of an interfering, near neighbor (NN). The results of this analysis will be used to help define a new photoelectric photometric instrumental sensor magnitude system (S) that is based on several thousand bright star magnitudes observed with the PXTE ST's. This new system will be implemented in Version 2 of the SKY2000 MC to provide improved predicted magnitudes in the mission run catalogs.

Sande, C. B.↗

Flight Performance of a Jet Power Plant: operating characteristics of a jet power plant as a function of altitude - III

The performance of a jet power plant consisting of a compressor and a turbine is determined by the characteristic curves of these component parts and is controllable by the characteristics of the compressor and the turbine i n relation t o each other. The normal. output, overload, and throttled load of the Jet power plant are obtained on the basis of assumed straight-line characteristics.

Weinig, F.↗

Pioneer Venus Orbiter Electron Temperature Probe

The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.

Krehbiel, J. P.↗

Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts

This process is designed to estimate the thickness change of a material through data analysis of a digitized version of an x-ray (or a digital x-ray) containing the material (with the thickness in question) and various tooling. Using this process, it is possible to estimate a material's thickness change in a region of the material or part that is thinner than the rest of the reference thickness. However, that same principle process can be used to determine the thickness change of material using a thinner region to determine thickening, or it can be used to develop contour plots of an entire part. Proper tooling must be used. An x-ray film with an S-shaped characteristic curve or a digital x-ray device with a product resulting in like characteristics is necessary. If a film exists with linear characteristics, this type of film would be ideal; however, at the time of this reporting, no such film has been known. Machined components (with known fractional thicknesses) of a like material (similar density) to that of the material to be measured are necessary. The machined components should have machined through-holes. For ease of use and better accuracy, the throughholes should be a size larger than 0.125 in. (.3 mm). Standard components for this use are known as penetrameters or image quality indicators. Also needed is standard x-ray equipment, if film is used in place of digital equipment, or x-ray digitization equipment with proven conversion properties. Typical x-ray digitization equipment is commonly used in the medical industry, and creates digital images of x-rays in DICOM format. It is recommended to scan the image in a 16-bit format. However, 12-bit and 8-bit resolutions are acceptable. Finally, x-ray analysis software that allows accurate digital image density calculations, such as Image-J freeware, is needed. The actual procedure requires the test article to be placed on the raw x-ray, ensuring the region of interest is aligned for perpendicular x-ray exposure capture. One or multiple machined components of like material/ density with known thicknesses are placed atop the part (preferably in a region of nominal and non-varying thickness) such that exposure of the combined part and machined component lay-up is captured on the x-ray. Depending on the accuracy required, the machined component fs thickness must be carefully chosen. Similarly, depending on the accuracy required, the lay-up must be exposed such that the regions of the x-ray to be analyzed have a density range between 1 and 4.5. After the exposure, the image is digitized, and the digital image can then be analyzed using the image analysis software.

Grau, David↗

The aerodynamic characteristics of eight very thick airfoils from tests in the variable density wind tunnel

Report presents the results of wind tunnel tests on a group of eight very thick airfoils having sections of the same thickness as those used near the roots of tapered airfoils. The tests were made to study certain discontinuities in the characteristic curves that have been obtained from previous tests of these airfoils, and to compare the characteristics of the different sections at values of the Reynolds number comparable with those attained in flight. The discontinuities were found to disappear as the Reynolds number was increased. The results obtained from the large-scale airfoil, a symmetrical airfoil having a thickness ratio of 21 per cent, has the best general characteristics.

Jacobs, Eastman N↗

Strain gage calibration

A temporary bonding system for accurately predetermining the individual apparent strain curve characteristics of the gages is used, and subsequently employs a computer to watch the apparent strain curves of the individual gages to determine which gages should be used together on transducers. The temporary bonding system requires a test block on which the gages are temporarily bonded, several thermocouples for monitoring temperature, and a data acquisition system for recording apparent strain data. Initially, a group of strain gages are attached to the test block using a bonding agent that disintegrates at high temperatures. The gages are then wired to an appropriate data acquisition and data, collected throughout a predetermined temperature excursion. Once the data is obtained, the test block is heated until the bonding agent disintegrates freeing the gages from the test block. The gages are then disconnected from the data acquisition system and cleaned, thereby ready for use on transducers.

Moore, T. C.↗

Parameterization of solar cells

The aggregation (sorting) of the individual solar cells into an array is commonly based on a single operating point on the current-voltage (I-V) characteristic curve. An alternative approach for cell performance prediction and cell screening is provided by modeling the cell using an equivalent electrical circuit, in which the parameters involved are related to the physical phenomena in the device. These analytical models may be represented by a double exponential I-V characteristic with seven parameters, by a double exponential model with five parameters, or by a single exponential equation with four or five parameters. In this article we address issues concerning methodologies for the determination of solar cell parameters based on measured data points of the I-V characteristic, and introduce a procedure for screening of solar cells for arrays. We show that common curve fitting techniques, e.g., least squares, may produce many combinations of parameter values while maintaining a good fit between the fitted and measured I-V characteristics of the cell. Therefore, techniques relying on curve fitting criteria alone cannot be directly used for cell parameterization. We propose a consistent procedure which takes into account the entire set of parameter values for a batch of cells. This procedure is based on a definition of a mean cell representing the batch, and takes into account the relative contribution of each parameter to the overall goodness of fit. The procedure is demonstrated on a batch of 50 silicon cells for Space Station Freedom.

Appelbaum, J.↗

F-5-L Boat Seaplane : performance characteristics

Performance characteristics for the F-5-L Boat Seaplane are given. Characteristic curves for the RAF-6 airfoil and the F-5-L wings, parasite resistance and velocity data, engine and propeller characteristics, effective and maximum horsepower, and cruising performance are discussed.

Diehl, W S↗

Correlation between nonequilibrium thermodynamic theory and V-I curves of a thermionic converter

The methods of irreversible thermodynamics are used as a basis for developing a transport theory applicable to thermionic cesium diodes. This theory is applied in describing certain aspects of experimental voltage-current (V-I) characteristic curves of a thermionic diode. Emphasis is placed on the open-circuit voltage and short-circuit current of the V-I curves. Experimental results show that the open-circuit voltage is essentially independent of the interelectrode spacing, whereas the short-circuit current varies inversely with the interelectrode separation. The inverse dependence is in agreement with the results of the present analysis and also with results expected from diffusion theory, which has been used in other analyses. In fact, the theory used in this investigation reduces to diffusion theory under special assumptions. Deviations from diffusion theory, which were found in experimental results, can be accounted for using the theory developed in this paper.

Robinson, L. B.↗

A comparison of soil moisture characteristics predicted by the Arya-Paris model with laboratory-measured data

Soil moisture characteristics predicted by the Arya-Paris model were compared with the laboratory measured data for 181 New Jersey soil horizons. For a number of soil horizons, the predicted and the measured moisture characteristic curves are almost coincident; for a large number of other horizons, despite some disparity, their shapes are strikingly similar. Uncertainties in the model input and laboratory measurement of the moisture characteristic are indicated, and recommendations for additional experimentation and testing are made.

Arya, L. M.↗

Photographic photometry with Iris diaphragm photometers

A general method is presented for solving problems encountered in the analysis of Iris diaphragm photometer (IDP) data. The method is used to derive the general shape of the calibration curve, allowing both a more accurate fit to the IDP data for comparison stars and extrapolation to magnitude ranges for which no comparison stars are measured. The profile of starlight incident and the characteristic curve of the plate are both assumed and then used to derive the profile of the star image. An IDP reading is then determined for each star image. A procedure for correcting the effects of a nonconstant background fog level on the plate is also demonstrated. Additional applications of the method are made in the appendix to determine the relation between the radius of a photographic star image and the star's magnitude, and to predict the IDP reading of the 'point of optimum density'.

Schaefer, B. E.↗

Postbuckling response of long thick plates loaded in compression including higher order transverse shearing effects

Buckling and postbuckling results are presented for compression-loaded simply-supported aluminum plates and composite plates with a symmetric lay-up of thin + or - 45 deg plies composed of many layers. Buckling results for aluminum plates of finite length are given for various length-to-width ratios. Asymptotes to the curves based on buckling results give N(sub xcr) for plates of infinite length. Postbuckling results for plates with transverse shearing flexibility are compared to results from classical theory for various width-to-thickness ratios. Characteristic curves indicating the average longitudinal direct stress resultant as a function of the applied displacements are calculated based on four different theories: Classical von Karman theory using the Kirchoff assumptions, first-order shear deformation theory, higher-order shear deformation theory, and 3-D flexibility theory. Present results indicate that the 3-D flexibility theory gives the lowest buckling loads. The higher-order shear deformation theory has fewer unknowns than the 3-D flexibility theory but does not take into account through-the-thickness effects. The figures presented show that small differences occur in the average longitudinal direct stress resultants from the four theories that are functions of applied end-shortening displacement.

Stein, Manuel↗

Postbuckling response of long thick plates loaded in compression including higher order transverse shearing effects

This paper presents buckling and postbuckling results for compression-loaded simply-supported aluminum plates and composite plates with a symmetric lay-up of thin +/-45-deg plies composed of many layers. Buckling results for aluminum plates of finite length are given for various length-to-width ratios. Asymptotes to the curves based on the buckling results give N(XCr) for plates of infinite length. Postbuckling results for plates with transverse shearing flexibility are compared to results from classical theory for various width-to-thickness ratios. Characteristic curves indicating the average longitudinal direct stress resultant as a function of the applied displacements are calculated based on four different theories: classical von Karman theory using the Kirchhoff assumptions, first-order shear deformation theory, higher-order shear deformation theory, and three-dimensional flexibility theory. Present results indicate that the three-dimensional flexibility theory gives the lowest buckling loads. The higher-order shear deformation theory has fewer unknowns than the three-dimensional flexibility theory but does not take into account through-the-thickness effects. The figures presented show that small differences occur in the average longitudinal direct stress resultants from the four theories that are functions of applied end-shortening displacement.

Stein, Manuel↗

Fundamentals of the Control of Gas-Turbine Power Plants for Aircraft: Standardization of the Computations Relating to the Control of Gas-Turbine Power Plants for Aircraft by the Employment of the Laws of Similarity - Part 1

It will be shown that by the use of the concept of similarity a simple representation of the characteristic curves of a compressor operating in combination with a turbine may be obtained with correct allowance for the effect of temperature. Furthermore, it bec~mes possible to simplify considerably the rather tedious investigations of the behavior of gas-turbine power plants under different operating conditions. Characteristic values will be derived for the most important elements of operating behavior of the power plant, which will be independent of the absolute valu:s of pressure and temperature. At the same time, the investigations provide the basis for scale-model tests on compressors and turbines.

Luehl, H.↗

Investigation of X24C-2 10-Stage Axial-Flow Compressor. III - Surge Characteristics

Compressor operation at low air flows for a given speed is limited by unstable flow conditions, commonly called surge. An investigation of surge in centrifugal compressors (reference 1) showed that the pulsation of pressures and velocities occurred when the slope of the compressor characteristic curve was positive and that the magnitude and frequency, as well as the incidence of surge, depended on the capacity and resistance of the total system. Although the theory presented in reference 1 is applicable to axial-floe compressors, little experimental information is available on the surge characteristics of the individual stages of axial-flow compressors, or on the variation of the surge characteristics with operating conditions. During the investigation to determine the performance of the X24C-2 compressor (references 2 and 3), instrumentation was added to study the surge characteristics and to determine the effect of speed and inlet pressure on the frequency, amplitude, and phase relation of the pressure pulsations behind each stage.

Buckner, Howard A., Jr.↗

Development and pilot line production of lithium doped silicon solar cells

Scaling up the BCl3 without O2 diffusion beyond 30 to 40 cells was investigated by using a 100 cell capacity diffusion boat which held the cells vertically. Sheet resistances and I-V curves were uniform with 10 to 20 cells spaced along the entire boat, so the quantity was increased to 40 and then 60 cells per diffusion. There was no change in cell output and uniformity going from 20 to 40 cells per diffusion; however only half the lithium cells fabricated from slices diffused in the 60 cell diffusion had efficiencies of 11% or better. Although uniform sheet resistances and I-V characteristic curves were obtained with up to 60 cells in the BCl3 with O2 diffusion, the short circuit currents were approximately 15% lower than the anticipated 135 to 140 mA. Consequently, work on this diffusion process has been aimed solely at increasing the short circuit current. The diffusion temperature was lowered from 1055 to 1000 and 950 C, and at each of these temperatures variations in diffusion time were investigated. At 1000 C short circuit currents were approximately 10 mA higher, 130 rather than 120 mA average.

Payne, P. A.↗

Multiscale Computer Simulation of Tensile and Compressive Strain in Polymer- Coated Silica Aerogels

While the low thermal conductivities of silica aerogels have made them of interest to the aerospace community as lightweight thermal insulation, the application of conformal polymer coatings to these gels increases their strength significantly, making them potentially useful as structural materials as well. In this work we perform multiscale computer simulations to investigate the tensile and compressive strain behavior of silica and polymer-coated silica aerogels. Aerogels are made up of clusters of interconnected particles of amorphous silica of less than bulk density. We simulate gel nanostructure using a Diffusion Limited Cluster Aggregation (DLCA) procedure, which produces aggregates that exhibit fractal dimensions similar to those observed in real aerogels. We have previously found that model gels obtained via DLCA exhibited stress-strain curves characteristic of the experimentally observed brittle failure. However, the strain energetics near the expected point of failure were not consistent with such failure. This shortcoming may be due to the fact that the DLCA process produces model gels that are lacking in closed-loop substructures, compared with real gels. Our model gels therefore contain an excess of dangling strands, which tend to unravel under tensile strain, producing non-brittle failure. To address this problem, we have incorporated a modification to the DLCA algorithm that specifically produces closed loops in the model gels. We obtain the strain energetics of interparticle connections via atomistic molecular statics, and abstract the collective energy of the atomic bonds into a Morse potential scaled to describe gel particle interactions. Polymer coatings are similarly described. We apply repeated small uniaxial strains to DLCA clusters, and allow relaxation of the center eighty percent of the cluster between strains. The simulations produce energetics and stress-strain curves for looped and nonlooped clusters, for a variety of densities and interaction parameters.

Good, Brian↗