Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charge-coupled devices (CCDs)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

A Multichannel Silicon Package for Large-Scale Skipper-CCD Experiments

The next generation of experiments for light-dark-matter and neutrino searches based on skipper charge-coupled devices (skipper-CCDs) introduces new challenges for the sensor packaging and readout architecture. Scaling the active mass while simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present a silicon multichip module design capable of hosting up to 16 skipper-CCDs, along with the fabrication process for the first prototypes. We thoroughly tested and characterized the assembled prototypes to build an empirical model for the video output signal of skipper-CCDs integrated into the silicon package. We then used this model in simulations to optimize the fabrication process and achieve the robust performance required for the full-scale array, which we validated through a new round of prototype fabrication. We outline the specifications selected for the ongoing production of 1500 silicon wafers that will ultimately add up to a 10-kg skipper-CCD array with 24000 readout channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

Brusco, Agustin [Buenos Aires U.]↗

Subtleties in the flat-fielding of charge-coupled device /CCD/ images

Astronomical photometry with CCDs will often involve relatively low signal levels (less than 1000 charge carriers per pixel), at which nonlinear effects sometimes become significant. These effects will probably play a role in the processing of Space Telescope data. The problem apparently arises because signal charges are not read out equally completely from all columns and all pixels. It is shown that, although a first-order correction can be made by subtracting a low-level flat field from all frames before conventional processing, higher accuracy can be achieved by modeling the response with a nonlinear function.

Baum, W. A.↗

New advancements in charge-coupled device technology - Sub-electron noise and 4096 x 4096 pixel CCDs

This paper reports on two new advancements in CCD technology. The first area of development has produced a special purpose CCD designed for ultra low-signal level imaging and spectroscopy applications that require sub-electron read noise floors. A nondestructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are reported. The second development involves the design and performance of a high resolution imager of 4096 x 4096 pixels, the largest CCD manufactured in terms of pixel count. The device utilizes a 7.5-micron pixel fabricated with three-level poly-silicon to achieve high yield.

Janesick, James R.↗

Scanning with charge-coupled devices

Results are presented of an investigation of six modes of using CCDs for searches of gamma-ray bursters, debris in geosynchronous space, satellites of asteroids, brown dwarfs, the tenth planet, comets, cometesimals, and various types of asteroids. A new discipline in astrophysics, 'scannerscopy', i.e., surveying with a CCD rather than with photography at a Schmidt telescope, is described. It uses the CCD in scanning rather than in sequencing of stare exposures as is done at most observatories, which can save telescope time and obviates the need for flat-fielding. Attention is given to the Tektronix 2048 x 2048 CCD, 38 arcmin wide, which is used to a limiting magnitude of 20.5 V. It is also shown to be successful for discovering rare and small near-earth asteroids. Possibilities with cameras on spacecraft that pass through the asteroid belt are described.

Gehrels, Tom↗

A programmable CCD driver circuit for multiphase CCD operation

A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.

Ewin, Audrey J.↗

Effects of radiation on charge-coupled devices

The effects of 1 MeV electron irradiation upon the performance of two phase, polysilicon aluminum gate CCDs are reported. Both n- and p-surface channel and n-buried channel devices are investigated using 64- and 128-stage line arrays. Characteristics measured as a function of radiation dose include: Transfer inefficiency, threshold voltage, field effect mobility, interface state density, full well signal level and dark current. Surface channel devices are found to degrade considerably at less than 10 to the 5th power rads (Si) due to the large increase in fast interface state density caused by radiation. Buried channel devices maintain efficient operation to the highest dose levels used.

Carnes, J. E.↗

Single photon X-ray imaging with charge-coupled devices /CCDs/

The paper describes a CCD camera facility designed and built for testing and characterization of CCDs in response to single X-ray photons in the 1-10 keV energy range. Results from the frontside-illuminated Fairchild 211 and 221 area imagers are presented; high quantum efficiency over the 3-6 keV range was verified. In order to avoid the problem of charge spreading at the higher energies, deep-depleted CCDs for soft X-ray imaging have been constructed, and good response was obtained at 6 keV. The present results are a first step toward the demonstration of the CCD as an appropriate device for at least the central part of the focal plane of a large X-ray telescope, e.g., the proposed Advanced X-ray Astrophysics Facility.

Griffiths, R. E.↗

Four-shooter - A large format charge-coupled device camera for the Hale telescope

The Hale telescope has employed an astronomical camera using four 800x800 CCDs in an optical arrangement that allows the imaging of a contiguous 1600-pixel-square region of the sky; reimaging optics are then used to yield a scale of 0.33 arcsec/pixel. Optical coatings are incorporated to yield a throughput at peak efficiency of nearly 50 percent, including telescope losses. This camera can be used in a scanning mode, in which the telescope tracking rate is offset and the charge is clocked in the chips in such a way that the charge image remains aligned with the optical image. Attention is given to the results of a survey for high-redshift quasars using this equipment, which has produced images for the most distant galaxy clusters yet discovered.

Gunn, James E.↗

Care, feeding, and use of charge-coupled device /CCD/ imagers at Palomar observatory

The paper describes the optical, mechanical, and electronic properties of the TI and RCA CCDs which have been applied to two-dimensional photometry and spectroscopy at Palomar. The drive, processing, and recording techniques are also discussed, and consideration is given to a focal conversion optical system, the Prime Focus Universal Extragalactic Instrument (PFUEI), which is used to more optimally match the Hale 5 meter plate scale. Calibration and data analysis are also examined.

Gunn, J. E.↗

Potential of CCDs for UV and X-ray plasma diagnostics

A program is under way to develop charge-coupled device (CCD) sensors for space-based X-ray astronomy imaging spectrometers. To date, laboratory line-emission spectra have been acquired throughout the range of 277 to 8000 eV (carbon through copper K-alpha emission) and CCD sensitivity has been demonstrated throughout the range of 1.1 through 8000 eV. Image resolution is excellent, limited almost entirely by the 15 micron pixel size. These results are presented and specialized techniques are described which permit such low energy response, high spectral resolution, and efficient charge collection. Finally, analysis is presented of one particular CCD characteristic which currently limits UV and X-ray performance: charge diffusion.

Janesick, J. R.↗

The development and applications of charge-coupled devices for space astronomy

The developments in charge-coupled device technology over the past decade are reviewed, with emphasis on the relevance of these developments to astronomical applications. The characteristics and limitations of current commercial devices are described, and the future requirements on CCDs for space astronomy are summarized for the X-ray and near UV, optical, and infrared wavelength ranges. Emphasis is placed on the commonality of technological development which is called for, including the issues of quantum detection efficiency (photon entrance and depletion depth), charge transfer efficiency, modulation transfer function, output noise level, and array size. The system requirements on focal plane instrumentation for space astronomy are summarized, and shown to have much in common for the different wavelength bands. These requirements are discussed in terms of CCD mosaicing, cryogenic cooling, and electronics. The overlap in CCD developments in the defense, astronomical and commercial arenas is summarized.

Griffiths, R. E.↗

Ultraviolet and extreme ultraviolet response of charge-coupled-device detectors

Results of a program to enhance the ultraviolet and extreme ultraviolet response of charge-coupled devices are presented. The ultimate goal of the program is to develop a large format device with both high and stable quantum efficiency from 100 to 3000 A that can be used as a windowless imaging detector in a space environment. Ultraviolet quantum efficiency measurements have been made for several ion-implanted and laser-annealed test CCDs. Quantum efficiencies as high as 22 percent at 2500 A, where the absorption depth in silicon is about 55 A, have been observed in one such test CCD. Quantum efficiency measurements of standard back-illuminated CCDs are also presented.

Stern, R. A.↗

Dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. II - Data handling and control systems

The data collection system for the MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes) is described. The system relies on an RCA 1802 microprocessor-based controller, which serves to collect and format data, to present data to a scan converter, and to operate a device communication bus. A NOVA minicomputer is used to record and recall frame images and to perform refined image processing. The RCA 1802 also provides instrument mode control for the MASCOT. Commands are issued using STOIC, a FORTH-like language. Sufficient flexibility has been provided so that a variety of CCDs can be accommodated.

Dewey, D.↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.↗

Multiple-amplifier sensing charged-coupled device: model and improvement of the node removal efficiency

The multiple-amplifier sensing charge-coupled device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout time for the same readout noise level compared with its predecessor, the skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called node removal inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the sense node of each amplifier after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. We introduce more details in the mathematical model of the NRI mechanism and provide techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other signals of the sensor. The proposed technique is demonstrated experimentally on a 16-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable with other sources of distortion such as the charge transfer inefficiency in scientific devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗