Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charged-particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications

Two optically clear, bright, scintillating ZnS materials have been identified that, like previous opaque ZnS scintillators, are excellent charged particle detectors. We show that ZnS is a good fast-neutron-to charged-particle converter making optically clear ZnS an intrinsic fast-neutron detector that does not require layering or mixing of converter materials and scintillator materials, and removes the limitations imposed by opaque ZnS scintillator materials used for more than a century. Thermal neutron detection using optically clear 6 LiF or 10 BN and clear ZnS may benefit from improved spatial resolution and light transmission. Properties and tests of clear scintillating ZnS are described. Fast-neutron imaging applications benefit from increased efficiency of these scintillators, minimal scattering in the scintillator, and increased useful detector volume. Charged particle and fast-neutron detectors have numerous applications in nuclear non-proliferation and security, nuclear and particle physics, and non-destructive testing and environmental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of the lunar photoelectron layer.

The Charged-Particle Lunar Environment Experiment (CPLEE), a part of the Apollo 14 ALSEP, is an ion-electron spectrometer capable of measuring ions and electrons with energies between 40 eV and 50 keV. Accordingly, the instrument, with apertures 26 cm above the surface, has detected a layer of photoelectrons, or photoelectron gas above the sunlit lunar surface with energies ranging up to 200 eV. The experimental data for periods when the moon was in the earth's magnetotail for electron energies between 40 and 200 eV follows a defined power-law spectrum. The implications of this measurement are two-fold in that the lunar surface potential can be immediately determined to be at least 200 V, and a value of the photoelectron yield of the lunar surface material for photon energies above 40 eV may be computed.

Reasoner, D. L.↗

Understanding hadronic interactions using advanced reconstruction techniques

ProtoDUNE-SP served as the prototype of the future Deep Underground Neutrino Experiment (DUNE). With a total liquid argon mass of 0.77 kt, it stood as the most extensive monolithic single-phase Liquid Argon Time Projection Chamber (LArTPC) ever constructed. Strategically located and operated at CERN, ProtoDUNE-SP benefited from a specialized charged-particle test beam, offering a momentum range of 0.3 - 7 GeV/c. This setup provided a unique opportunity to conduct in-depth studies on hadronic interactions within argon. Hadronic interactions play a fundamental role in neutrino physics, particularly in the intricacies of neutrino detection. We depend on analyzing the outcomes of these interactions to accurately determine both the flavor and energy of the interacting neutrinos. Pions, as one of the primary byproducts of neutrino interactions, are crucial for understanding the overall dynamics and kinematics of these processes. Accurately characterizing and understanding the interaction of pions with argon can significantly enhance the precision of neutrino simulations and measurements.Being a Liquid Argon Time Projection Chamber (LArTPC), ProtoDUNE-SP is distinguished by its ability to produce high-definition images of charged particles as they traverse through the detector's active volume. Yet, accurately reconstructing these particle interactions and determining their kinematic attributes remains a challenging task. The successes of deep learning in diverse domains, especially in image recognition, provide a promising approach for addressing this challenge in ProtoDUNE. This thesis discusses a measurement of the Piplus - argon inelastic cross section in the energy range of 2400 to 3000 MeV, using data taken by protoDUNE during the fall of 2018. Additionally, panoptic segmentation, a machine learning technique, is introduced and validated through its application in the reconstruction of the neutral pion rest mass. The aim is to showcase how these advanced methods can enhance the quality of event reconstruction.

Sarasty Segura, Carlos Eduardo↗

Techniques for the remote sensing of space plasma in the heliosphere via energetic neutral atoms - A review

A survey is conducted for state-of-the-art techniques for detecting energetic neutral atoms (ENAs) in the 100-300 keV range, in regions from the heliospheric boundary to the auroral zones where the solar wind plays a crucial role. While ENA spectrometry allows sampling of the mass and energy distributions of a distant plasma, ENA imaging gives a global view of the structures and dynamics of an extended plasma. The ENA instrument designs discussed share many components which exhibit excellent flight performance as elements in charged-particle analyzers for space missions.

Hsieh, K. C.↗

Fast-neutron response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators

The response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators to fast neutrons is investigated. Neutron-induced charged-particle reactions are observed in both materials when exposed to the fast neutrons produced by an AmBe source, with pulse-shape discrimination used to separate channels. LaBr 3 (Ce) is found to have the best separation between reaction channels, while LaCl 3 (Ce) has a significantly higher efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Level Structure of {sup 31}S Via {sup 32}S({ital p,d}) {sup 31}S

Background: Properties of proton-unbound S-31 states determine the P-30(p, gamma) S-31 reaction rate, which has a significant impact on explosive hydrogen burning in classical novae and type-I x-ray bursts. Despite several previous studies, uncertainties still remain with respect to the nuclear structure of S-31 near the proton threshold. Purpose: The level structure of S-31 has been presently investigated via a charged-particle spectroscopy experiment using the S-32(p, d) S-31 reaction. Method: Deuterons corresponding to S-31 excited states with 3.285 <= E-x <= 10.8 MeV were momentum analyzed via an Enge split-pole spectrograph at six laboratory angles between 10 degrees and 62 degrees. Differential cross sections of the S-32(p, d)S-31 reaction were measured at E-p = 34.5 MeV. Distorted-wave Born approximation calculations were performed to constrain the spin-parity assignments of several of the observed levels. Results: We have detected 72 excited states of S-31, out of which 17 are within the astrophysical region of interest corresponding to the temperature range of 0.1-1.5 GK. We have resolved the discrepancy in the spin and parity of an excited state with E-x = 6542 keV, showing that is it not J(pi) = 3/2(-), and therefore the contribution of this state to the P-30(p, gamma) reaction rate is likely much less significant than previously thought owing to the larger angular-momentum transfer required to populate this excited state. Moreover, our measurement results help consolidate the spin-parity assignments for the 6377 and 6636 keV states in S-31. Conclusions: This work presents the most comprehensive spin-parity assignments to date from a single-neutron transfer reaction on S-32 to S-31 excited states in the region between 6 to 7 MeV excitation energy. This region is significant for the determination of the P-30(p, gamma)S-30 reaction rate over the temperatures characteristic of explosive hydrogen burning in novae.

Setoodehnia, K.↗

Optimization of the Orbiting Wide-Angle Light Collectors (OWL) Mission for Charged-Particle and Neutrino Astronomy

OWL [1] uses the Earth's atmosphere as a vast calorimeter to fully enable the emerging field of charged-particle astronomy with high-statistics measurements of ultra-high-energy cosmic rays (UHECR) and a search for sources of UHE neutrinos and photons. Confirmation of the Greisen-Zatsepin-Kuzmin (GZK) suppression above approx. 4 x 10(exp 19) eV suggests that most UHECR originate in astrophysical objects. Higher energy particles must come from sources within about 100 Mpc and are deflected by approx. 1 degree by predicted intergalactic/galactic magnetic fields. The Pierre Auger Array, Telescope Array and the future JEM-EUSO ISS mission will open charged-particle astronomy, but much greater exposure will be required to fully identify and measure the spectra of individual sources. OWL uses two large telescopes with 3 m optical apertures and 45 degree FOV in near-equatorial orbits. Simulations of a five-year OWL mission indicate approx. 10(exp 6) sq km/ sr/ yr of exposure with full aperture at approx. 6 x 10(exp 19) eV. Observations at different altitudes and spacecraft separations optimize sensitivity to UHECRs and neutrinos. OWL's stereo event reconstruction is nearly independent of track inclination and very tolerant of atmospheric conditions. An optional monocular mode gives increased reliability and can increase the instantaneous aperture. OWL can fully reconstruct horizontal and upward-moving showers and so has high sensitivity to UHE neutrinos. New capabilities in inflatable structures optics and silicon photomultipliers can greatly increase photon sensitivity, reducing the energy threshold for n detection or increasing viewed area using a higher orbit. Design trades between the original and optimized OWL missions and the enhanced science capabilities are described.

Optimization↗

X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory

Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.

Ford, P. G.↗

Clusters of DNA induced by ionizing radiation: formation of short DNA fragments. I. Theoretical modeling

We have developed a general theoretical model for the interaction of ionizing radiation with chromatin. Chromatin is modeled as a 30-nm-diameter solenoidal fiber comprised of 20 turns of nucleosomes, 6 nucleosomes per turn. Charged-particle tracks are modeled by partitioning the energy deposition between primary track core, resulting from glancing collisions with 100 eV or less per event, and delta rays due to knock-on collisions involving energy transfers >100 eV. A Monte Carlo simulation incorporates damages due to the following molecular mechanisms: (1) ionization of water molecules leading to the formation of OH, H, eaq, etc.; (2) OH attack on sugar molecules leading to strand breaks: (3) OH attack on bases; (4) direct ionization of the sugar molecules leading to strand breaks; (5) direct ionization of the bases. Our calculations predict significant clustering of damage both locally, over regions up to 40 bp and over regions extending to several kilobase pairs. A characteristic feature of the regional damage predicted by our model is the production of short fragments of DNA associated with multiple nearby strand breaks. The shapes of the spectra of DNA fragment lengths depend on the symmetries or approximate symmetries of the chromatin structure. Such fragments have subsequently been detected experimentally and are reported in an accompanying paper (B. Rydberg, Radiat, Res. 145, 200-209, 1996) after exposure to both high- and low-LET radiation. The overall measured yields agree well quantitatively with the theoretical predictions. Our theoretical results predict the existence of a strong peak at about 85 bp, which represents the revolution period about the nucleosome. Other peaks at multiples of about 1,000 bp correspond to the periodicity of the particular solenoid model of chromatin used in these calculations. Theoretical results in combination with experimental data on fragmentation spectra may help determine the consensus or average structure of the chromatin fibers in mammalian DNA.

Non-NASA Center↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Small Deflection Energy Analyzer for Energy and Angular Distributions

The development of the Small Deflection Energy Analyzer (SDEA) charged-particle spectrometer for energy and angle distributions responds to a longstanding need to measure the wind velocity vector in Earth s thermosphere, and to obtain the ion-drift vector in the ionosphere. The air and ions above 120 km are endowed with bulk velocities and temperatures just like air near the ground, but with separate spatial and temporal variations. It is important to understand these not only for study of the physics and chemistry of the Sun-Earth connection, but also for spacecraft orbit predictions, and communications through the ionosphere. The SDEA consists of a pair of parallel conducting plates separated by a small distance, with an entrance slit on one end, and an exit slit on the other. A voltage applied to these plates develops an electric field between the plates, and this field deflects ions passing through it. If an ion has too little energy, it will strike one of the plates. If it has too much, it will strike the back wall. An ion with the amount of energy being searched for will have its trajectory bent just enough to exit the back slit. The SDEA units are compact, rectangular, and operate with low voltages. The units can be built up into small arrays. These arrays could be used either to widen the field of view or to sharpen an existing one. This approach can also be used to obtain angular distributions in two planes simultaneously, thus cutting down the ion source power requirements in half. This geometry has enabled a new mass-spectrometer concept that can provide miniaturized mass spectrometers for use in industrial plants, air-pollution monitoring, and noxious-gas detection.

Herrero, Federico A.↗

Source characterization of a detector for heavy and superheavy nuclei

A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Augmented signal processing in Liquid Argon Time Projection Chambers with a deep neural network

The Liquid Argon Time Projection Chamber (LArTPC) is an advanced neutrino detector technology widely used in recent and upcoming accelerator neutrino experiments. It features a low energy threshold and high spatial resolution that allow for comprehensive reconstruction of event topologies. In current-generation LArTPCs, the recorded data consist of digitized waveforms on wires produced by induced signal on wires of drifting ionization electrons, which can also be viewed as two-dimensional (2D) (time versus wire) projection images of charged-particle trajectories. For such an imaging detector, one critical step is the signal processing that reconstructs the original charge projections from the recorded 2D images. For the first time, we introduce a deep neural network in LArTPC signal processing to improve the signal region of interest detection. By combining domain knowledge (e.g., matching information from multiple wire planes) and deep learning, this method shows significant improvements over traditional methods. This work details the method, software tools, and performance evaluated with realistic detector simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Critical thermonuclear reactions in classical novae and type I X-ray bursts

The goal of this project was to experimentally constrain the nuclear reaction rates whose uncertainties have the largest impact on models of classical novae and Type-I X-ray bursts. These astrophysical events occur when a white dwarf or neutron star, respectively, accretes hydrogen and helium from a companion star until a thermonuclear runaway ensues. The primary reactions of interest to this project for novae and X-ray bursts are 30 P(ρ,γ) 31 S and 15 O(α,γ) 19 Ne. The project methodology was to develop a new radiation detection system in two phases to measure the low-energy beta-delayed particle emissions of 31 Cl and 20 Mg at the National Superconducting Cyclotron Laboratory (NSCL) in order to constrain these two reaction rates. In particular, a gas-filled charged-particle detector was to be designed, constructed and operated, in concert with the SeGA array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Charged-particle lunar environment experiment

Charged particle lunar environment experiment of Apollo 14 detecting particle fluxes at lunar surface resulting from wide range of lunar surface, magnetospheric, and interplanetary data

Obrien, B. J.↗