Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cherenkov radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of a particle shower at the Glashow resonance with IceCube

The Glashow resonance describes the resonant formation of a W - boson during the interaction of a high-energy electron antineutrino with an electron, peaking at an antineutrino energy of 6.3 petaelectronvolts (PeV) in the rest frame of the electron. Whereas this energy scale is out of reach for currently operating and future planned particle accelerators, natural astrophysical phenomena are expected to produce antineutrinos with energies beyond the PeV scale. Here we report the detection by the IceCube neutrino observatory of a cascade of high-energy particles (a particle shower) consistent with being created at the Glashow resonance. A shower with an energy of 6.05 ± 0.72 PeV (determined from Cherenkov radiation in the Antarctic Ice Sheet) was measured. Features consistent with the production of secondary muons in the particle shower indicate the hadronic decay of a resonant W - boson, confirm that the source is astrophysical and provide improved directional localization. The evidence of the Glashow resonance suggests the presence of electron antineutrinos in the astrophysical flux, while also providing further validation of the standard model of particle physics. Its unique signature indicates a method of distinguishing neutrinos from antineutrinos, thus providing a way to identify astronomical accelerators that produce neutrinos via hadronuclear or photohadronic interactions, with or without strong magnetic fields. As such, knowledge of both the flavour (that is, electron, muon or tau neutrinos) and charge (neutrino or antineutrino) will facilitate the advancement of neutrino astronomy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

Dynamical effects from anomalies: Modified electrodynamics in Weyl semimetals

Here, we discuss the modified quantum electrodynamics from a time-reversal-breaking Weyl semimetal coupled with a U⁡(1) gauge (electromagnetic) field. A key role is played by the soft dispersion of the photons in a particular direction, say $\hat{z}$, due to the Hall conductivity of the Weyl semimetal. Due to the soft photon, the fermion velocity in $\hat{z}$ is logarithmically reduced under renormalization group flow, together with the fine-structure constant. Meanwhile, fermions acquire a finite lifetime from spontaneous emission of the soft photon, namely, the Cherenkov radiation. At low-energy E, the inverse of the fermion lifetime scales as τ -1 ~E/PolyLog⁡(E). Therefore, even though fermion quasiparticles are eventually well-defined at very low energy, over a wide intermediate energy window the Weyl semimetal behaves like a marginal Fermi liquid. Phenomenologically, our results are more relevant for emergent Weyl semimetals, where the fermions and photons all emerge from strongly correlated lattice systems. Possible experimental implications are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extinction Monitoring of Pulsed Proton Beams Using FPGA-Based Peak Detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam - a requirement known as "extinction". We present a method to measure the out-of-time particle rates to calculate the level of extinction in the inter-pulse gaps. The proposed method utilizes an array of quartz Cherenkov radiators and photomultiplier tubes to detect particles scattered from a vacuum chamber in the M4 transfer beamline at Fermilab.The measurement will employ a new μTCA-based FPGA system for data acquisition and signal processing, utilizing real-time peak detection algorithms to count scattered beam particles. By integrating data over many transfers, the time profile of the out-of-time beam will be resolved to fractional levels relative to that of the in-time beam. These results are compared with G4beamline simulations to validate models of beam transport, dynamics, and extinction, providing critical input for optimizing beam delivery to Mu2e.

Hensley, Ryan [UC, Davis]↗

Calculating beam extinction in a pulsed proton beam using FPGA-based peak detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam, a requirement known as “extinction”. Utilizing a new μTCA-based FPGA data acquisition system, we recorded live particle data from scattered particles incident on an array of quartz Cherenkov radiators and photomultiplier tubes to measure the extinction in the inter-pulse gaps in the pulsed proton beam. Minuscule errors in the derived signal period can make a measurement of the extinction impossible, so after taking a Fourier transform, further optimizations on the period were done based on the assumption that the signal period is stable over the full time of the beam spill while it is being resonantly extracted. After these optimizations, the beam extinction was shown to be on the level of 10^3.

Hensley, Ryan [UC, Davis]↗

The Next Breakthroughs in Neutrino Physics (LDRD Final Report)

The neutrino is an important fundamental particle, one of the building blocks of the universe. Abetter understanding of the neutrino will answer questions regarding the origin of mass, the matter and anti-matter asymmetry of the universe, and the nature of dark matter. The nation's research community has recognized that the answers to these and other questions are within reach and has assigned neutrino experiments the highest priority for both nuclear and particle physics programs. We are investigating three aspects of neutrino experimentation: detection techniques, target materials, and data analysis. Our efforts targeted multiple applications including experiments to measure neutrinoless double-beta-decay, neutrino-oscillation and neutrino mass. Our research objectives include (1) developing approaches that make detectors scalable to larger sizes and insensitive to background signals; (2) increasing the signal strength and reducing noise from targets; and (3) efficiently distinguishing background noise from signals during analysis. In this LDRD we have advanced all of these areas. We have demonstrated the scale up of a metal organic framework that can adsorb xenon directly from the air that will allow for large neutrino detectors made from xenon. We have studied the use of Cherenkov radiation to reduce the signal backgrounds. We demonstrated the cracking of hydrogen to make atomic tritium for neutrino mass measurements, and lastly we demonstrated the benefits of machine learning techniques to improve signal to noise during analysis

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upgrades of the ATLAS Zero Degree Calorimeter System for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1 were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with $\text{H}_2$-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new "Reaction Plane Detectors" (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run~3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run~3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metamaterial-Inspired Vacuum Electron Devices and Accelerators

Metamaterials (MTMs) are structured materials with subwavelength features that can be engineered to have some unique properties not found in nature, such as negative refractive index, reversed Doppler effect, and reversed Cherenkov radiation. Based on these novel MTMs, several important research groups have made great attempts to develop novel MTM-inspired vacuum electron devices (VEDs) and accelerators. Just as solid-state power devices are innovated by incessant emerging of new semiconductor materials, VEDs can also be inspired by MTMs to have very remarkable advantages, such as smaller size, higher power, higher efficiency, and/or larger gain relative to conventional VEDs, such as traveling-wave tubes, backward-wave oscillators, and klystrons. Similarly, relative to conventional accelerators, MTM-inspired accelerators have obvious advantages, such as smaller size and higher accelerating gradient. Furthermore, MTM-inspired devices have promising applications in areas such as radar, communication, electronic warfare, microwave heating, and imaging.

43 PARTICLE ACCELERATORS↗

A potential probe of Fundamental Interactions using Multi-Modal Cosmic Ray events

The Horizon-T experiment in Tien Shan is based on the idea of measuring the time at which EAS disc passes the observation level with nanosecond accuracy. The detector system consists of ten charged particles registration points located at distances of up to several hundred meters from each other. The points are equipped with detectors based on registration of Cherenkov radiation in glass and registration of scintillation light in polystyrene. The detectors register the arrival times of charged particles at the observation level with a resolution of ~2 ns, as required to study the spatial and temporal characteristics of the EAS and the structure of the multi-modal events specifically. Over the period of the Horizon-T data taking since 2017 to present, a large number of multi-modal events were detected. The data has presented numerous challenges that show the direction towards the further development of the detector system and of the analysis methods and techniques that could be applied to these multi-modal events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fiber reinforced aerogel composites

Fiber reinforced aerogel composites, including a transparent composite material that contains an aerogel and fibers embedded into the aerogel and/or bonded to one or more surfaces of the aerogel, and composites that contain an aerogel tile and an assemblage of fibers embedded into the aerogel tile or bonded to the aerogel tile that are useful as Cherenkov radiators for the detection and identification of subatomic particles. Also, methods of making and using the composites.

Pegg, Ian Louis↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On numerical errors to the fields surrounding a relativistically moving particle in PIC codes

The particle-in-cell (PIC) method is widely used to model the self-consistent interaction between discrete particles and electromagnetic fields. It has been successfully applied to problems across plasma physics including plasma based acceleration, inertial confinement fusion, magnetically confined fusion, space physics, astrophysics, high energy density plasmas. In many cases the physics involves how relativistic particles (those with high relativistic γ factors) are generated and interact with plasmas. However, when relativistic particles stream across the grid, both in “vacuum” and in plasma, many numerical issues may arise which can lead to unphysical results. We present a detailed analysis of how discretized Maxwell solvers used in PIC codes can lead to numerical errors to the fields that surround particles that move at relativistic speeds across the grid. Expressions for the axial electric field as integrals in k space are presented that reveal two types of errors. The first arises from errors to the numerator of the integrand and leads to unphysical fields that are antisymmetric about the particle. Furthermore, the second arises from errors to the denominator of the integrand and lead to Cherenkov like radiation in “vacuum”. These fields are not anti-symmetric, extend behind the particle, and cause the particle to accelerate or decelerate depending on the solver and parameters. The unphysical fields are studied in detail for two representative solvers - the Yee solver and the FFT based solver. Although the Cherenkov fields are absent, the space charge fields are still present in the fundamental Brillouin zone for the FFT based solvers. In addition, the Cherenkov fields are present in higher order zones for the FFT based solvers. Comparison between the analytical solutions and PIC simulation results are presented. A solution for eliminating these unphysical fields by modifying the k operator in the axial direction is also presented. Using a customized finite difference solver, this solution was successfully implemented into OSIRIS [1]. Results from the customized solver are also presented. Additionally, this solution will be useful for a beam of particles that all move in one direction with a small angular divergence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗