Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coded aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

Large Coded Aperture Mask for Spaceflight Hard X-ray Images

The 2.6 square meter coded aperture mask is a vital part of the Burst Alert Telescope on the Swift mission. A random, but known pattern of more than 50,000 lead tiles, each 5 mm square, was bonded to a large honeycomb panel which projects a shadow on the detector array during a gamma ray burst. A two-year development process was necessary to explore ideas, apply techniques, and finalize procedures to meet the strict requirements for the coded aperture mask. Challenges included finding a honeycomb substrate with minimal gamma ray attenuation, selecting an adhesive with adequate bond strength to hold the tiles in place but soft enough to allow the tiles to expand and contract without distorting the panel under large temperature gradients, and eliminating excess adhesive from all untiled areas. The largest challenge was to find an efficient way to bond the > 50,000 lead tiles to the panel with positional tolerances measured in microns. In order to generate the desired bondline, adhesive was applied and allowed to cure to each tile. The pre-cured tiles were located in a tool to maintain positional accuracy, wet adhesive was applied to the panel, and it was lowered to the tile surface with synchronized actuators. Using this procedure, the entire tile pattern was transferred to the large honeycomb panel in a single bond. The pressure for the bond was achieved by enclosing the entire system in a vacuum bag. Thermal vacuum and acoustic tests validated this approach. This paper discusses the methods, materials, and techniques used to fabricate this very large and unique coded aperture mask for the Swift mission.

Vigneau, Danielle N.↗

Digital autofocusing of a coded-aperture Laue diffraction microscope

To provide optimal depth resolution with a coded-aperture Laue diffraction microscope, an accurate position of the coded-aperture and its scanning geometry need to be known. However, finding the geometry by trial and error is a time-consuming and often challenging process because of the large number of parameters involved. In this paper, we propose an optimization approach to automate the focusing process after data is collected. Here we demonstrate the robustness and efficiency of the proposed approach with experimental data taken at a synchrotron facility.

47 OTHER INSTRUMENTATION↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

Two-Sided Coded Aperture Imaging Without a Detector Plane

We introduce a novel design for a two-sided, coded-aperture, gamma-ray imager suitable for use in stand off detection of orphan radioactive sources. The design is an extension of an active-mask imager that would have three active planes of detector material, a central plane acting as the detector for two (active) coded-aperture mask planes, one on either side of the detector plane. In the new design the central plane is removed and the mask on the left (right) serves as the detector plane for the mask on the right (left). This design reduces the size, mass, complexity, and cost of the overall instrument. In addition, if one has fully position-sensitive detectors, then one can use the two planes as a classic Compton camera. This enhances the instrument's sensitivity at higher energies where the coded-aperture efficiency is decreased by mask penetration. A plausible design for the system is found and explored with Monte Carlo simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coded aperture imaging for fluorescent x-rays

We employ a coded aperture pattern in front of a pixilated charge couple device detector to image fluorescent x-rays (6–25 KeV) from samples irradiated with synchrotron radiation. Coded apertures encode the angular direction of x-rays, and given a known source plane, allow for a large numerical aperture x-ray imaging system. The algorithm to develop and fabricate the free standing No-Two-Holes-Touching aperture pattern was developed. The algorithms to reconstruct the x-ray image from the recorded encoded pattern were developed by means of a ray tracing technique and confirmed by experiments on standard samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

A coded aperture with sub-mean-free-path thickness for implosion geometry imaging on ICF and IFE experiments

Inertial confinement fusion and inertial fusion energy experiments diagnose the geometry of the fusion region through imaging of the neutrons released through fusion reactions. Pinhole arrays typically used for such imaging require thick substrates to obtain high contrast along with a small pinhole diameter to obtain high resolution capability, resulting in pinholes that have large aspect ratios. This leads to expensive pinhole arrays that have small solid angles and are difficult to align. Here, we propose a coded aperture with scatter and partial attenuation (CASPA) for fusion neutron imaging that relaxes the thick substrate requirement for good image contrast. These coded apertures are expected to scale to larger solid angles and are easier to align without sacrificing imaging resolution or throughput. We use Monte Carlo simulations (Geant4) to explore a coded aperture design to measure neutron implosion asymmetries on fusion experiments at the National Ignition Facility (NIF) and discuss the viability of this technique, matching the current nominal resolution of 10 µm. The results show that a 10 mm thick tungsten CASPA can image NIF implosions with neutron yields above 10 14 with quality comparable to unprocessed data from a current NIF neutron imaging aperture. Furthermore, this CASPA substrate is 20 times thinner than the current aperture arrays for fusion neutron imaging and less than one mean free-path of 14.1 MeV neutrons through the substrate. Since the resolution, solid angle, and throughput are decoupled in coded aperture imaging, the resolution and solid angle achievable with future designs will be limited primarily by manufacturing capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the cosmic-ray induced background in coded aperture high energy gamma-ray telescopes

While the application of coded-aperture techniques to high-energy gamma-ray astronomy offers potential arc-second angular resolution, concerns were raised about the level of secondary radiation produced in a thick high-z mask. A series of Monte-Carlo calculations are conducted to evaluate and quantify the cosmic-ray induced neutral particle background produced in a coded-aperture mask. It is shown that this component may be neglected, being at least a factor of 50 lower in intensity than the cosmic diffuse gamma-rays.

Owens, Alan↗

The use of an active coded aperture for improved directional measurements in high energy gamma-ray astronomy

The coded aperture, a refinement of the scatter-hole camera, offers a method for the improved measurement of gamma-ray direction in gamma-ray astronomy. Two prototype coded apertures have been built and tested. The more recent of these has 128 active elements of the heavy scintillator BGO. Results of tests for gamma-rays in the range 50-500 MeV are reported and future application in space discussed.

Johansson, A.↗

New Mission Concept: Compton Telescope with Coded Aperture Mask (GECCO) for MeV Gamma-ray Astronomy

The Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO) is a novel Explorer-class concept for a next-generation telescope covering the poorly explored hard X-ray and soft gamma-ray energy regimes. The instrument is based on a novel CdZnTe imaging calorimeter and a deployable coded aperture mask, which enable it to reach 1 arcmin angular resolution and 1% energy resolution. GECCO will connect the arcminute angular resolution observations from X-ray telescopes to high-energy images of the Galactic plane provided by Fermi-LAT, and will focus on the exploration of heavily populated sky regions such as the Galactic Center and the Carina and Cygnus regions to decipher the nature of their emission. These measurements will probe with unprecedented capabilities the possible origin of this emission as dark matter, new types of sources, or currently unresolved populations of point sources. Uncoded observations with GECCO’s Compton telescope will provide wide field-of-view sky monitoring for transient events, synergizing with gravitational wave and high-energy neutrino facilities. In addition, GECCO will conduct a high-sensitivity search for the positron sources in the Galactic Center responsible for the enigmatic 511 keV positron annihilation line excess, will search for as-yet untested candidates for dark matter, will detect and identify high-redshift blazars with excellent angular resolution, and will explore Galactic chemical evolution and sites of explosive element synthesis.

Alexander A Moiseev↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma-ray observations of Cygnus X-1 and Cygnus X-3 using a coded-aperture telescope

A balloon-borne coded-aperture telescope, measuring gamma-ray photons in the 160 keV to 9.3 MeV range, was used to observe the Cygnus region of the sky on October 1 and 2, 1984. In the 2-9.3-MeV band, evidence is found for a hard spectral component with a mean flux level at the top of the atmosphere of 7.4 + or - 2.5 x 10 to the -7th photons/sq cm per s per keV, inconsistent with the predictions of the inverse Compton models normally used to describe the X-ray emission. Both Cyg X-1 and Cyg X-3 could be observed simultaneously with the telescope. The results are used to establish 1-sigma upper flux limits on the spectral emission from Cyg X-3.

Mcconnell, M. L.↗

Results from the coded aperture neutron imaging system.

Because of their penetrating power, energetic neutrons and gamma rays ({approx}1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging - a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the Coded Aperture Neutron Imaging System (CANIS).

Because of their penetrating power, energetic neutrons and gamma rays ({approx}1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging- a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coded aperture devices for viewing extended objects from space

Coded aperture sensors for photons or energetic neutral atoms (ENAs), which incorporate FOV limiters and subdivide the object field into a number of elements which is smaller than the number of detector pixels, are described. A least squares fit to the data is made in reconstructing the object field. To evaluate the optics and reconstruction algorithms, two 'breadboard' sensors have been constructed, one based on a film camera and the other upon a UV-light sensitive microchannel plate detector system. Results obtained thus far show that the concept is viable, and no special difficulties should be encountered in adapting the detector geometries to neutral particle imaging systems. Charged particle deflection plates could be incorporated into the region between the FOV limiter and the aperture, or installed ahead of the limiter.

Curtis, C. C.↗

Coded aperture imaging of fusion source in a plasma focus operated with pure D{sub 2} and a D{sub 2}-Kr gas admixture

The coded aperture imaging (CAI) technique has been used to investigate the spatial distribution of DD fusion in a 1.6 kJ plasma focus (PF) device operated in, alternatively, pure deuterium or deuterium-krypton admixture. The coded mask pattern is based on a singer cyclic difference set with 25% open fraction and positioned close to 90 Degree-Sign to the plasma focus axis, with CR-39 detectors used to register tracks of protons from the D(d, p)T reaction. Comparing the coded aperture imaging proton images for pure D{sub 2} and D{sub 2}-Kr admixture operation reveals clear differences in size, density, and shape between the fusion sources for these two cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗