Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coherent optical effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The effect of timing errors in optical digital systems

The effects of imperfect timing in direct detection (non-coherent) optical binary systems using both PPM and on-off keying for bit transmission are investigated. Particular emphasis is placed on specification of timing accuracy, and an examination of system degradation when this accuracy is not attained. Bit error probabilities are shown as a function of timing errors, from which average error probabilities can be computed for specific synchronization methods. Of significant importance is the presence of a residual, or irreducible error probability in both systems, due entirely to the timing system, that cannot be overcome by the data channel.

Gagliardi, R.↗

Optimizing spin qubit coherence through materials codesign

The evolution of defect-based spin qubit systems is currently transitioning from fundamental studies and proof-of-concept demonstrations into applications in the burgeoning field of quantum technology. Within this context, new challenges emerge, in particular, the need to understand and engineer the fundamental materials that form the hardware building blocks critical for the scalability and wide-scale adoption of such technologies. While earlier discussions have often focused on qubits within idealized systems, major limitations on spin coherence and optical properties arise from effects imposed by the nonideality of the surrounding host matrix. Decoherence can stem from a variety of sources, including other qubits, nuclear spins, and parasitic point- and extended defects, which interact with the qubit via magnetic and electric fields, photons, phonons, and strain. In this article, we focus on the relevant sources and mechanisms through which decoherence occurs and provide potential mitigation strategies via the synergistic integration of first-principles simulations and materials synthesis and engineering. We aim to provide a tangible link between material properties and material functions thereby enabling materials-by-design.

ab initio simulations↗

Determination of atmospheric structure function by using a single coherent detector

The wave structure function associated with atmospheric turbulence is important in the effective design of telescopes for coherent optical receivers. This paper describes a method of measurement of the wave structure function by employing an already existing optical receiver. The aperture of this receiver's telescope is masked by an opaque screen with two small holes. It is then shown that when the incident beam obeys Gaussian statistics, the receiver's A.M. output can be simply related to the wave structure function of the incident beam.

Lang, R. H.↗

A binary coherent optical receiver for the free-space channel

The structure of a coherent binary optical MAP receiver was derived and the effects of background radiation and phase estimation errors on receiver performance were evaluated. It was found that random phase errors do not affect the performance of the coherent receiver significantly, as long as the standard deviation of the phase error remains less than roughly 0.14 radians (or 8 degrees). It was also shown that background radiation is effectively suppressed by the optical homodyne receiver: Significant deterioration in receiver performance is observed only in the presence of extremely intense background fields. The most notable characteristic of the binary optical homodyne receiver therefore appears to be its ability to achieve quantum limited performance in high background environments, provided that sufficiently accurate estimates of the received phase can be obtained.

Vilnrotter, V. A.↗

(abstract) Observation by Clementine of a Hugh Opposition Surge on the Moon at Very Small Solar Phase Angles

The Clementine mission enabled the first quantative observations of the Moon at very small solar phase angles. It is well established from Earth-based observations that the Moon exhibits a non-linear increase in brightness as its face becomes fully illuminated to a terrestrial observer. Because the models of the opposition effect are sensitive indicators of surfical compaction state and particle size, observations at small solar phase angles are important to obtain. A recent model for optical coherent backscatter seeks to explain a narrow opposition spike at very small phase angles (< 1 degree) seen on several icy satellites , including Europa, Icarus 90, and Oberon . Over 90 images of the Moon's surface at phase angles less than 0.5(deg) (the minimum phase angle observable from Earth due to the Moon's angular size) were obtained by the Clementine spacecraft. Our analysis of these images shows the moon exhibits a surge in brightness of approximately 20% below 0.25(deg), comparable to the values observed on icy satellites. No color dependence was detected in the lunar phase curve below 2 degrees.

partical size icy satellites Europa Icarus 90 Ober↗

Optical considerations in infrared heterodyne spectrometer design

The optical design considerations for optimization of sensitivity, tunability, and versatility of an infrared heterodyne spectrometer are discussed using the GSFC CO2 laser heterodyne spectrometer optical front end as an example. Problems related to the coherent nature of the laser local oscillator beam (e.g., interference effects at edges of optical elements and at the beam combining beamsplitter) are described and proper beamsplitter design discussed. Optimum matching to the telescope is discussed. The severe effects of large central obscuration on the coherent telescope efficiency are described and steps to partially recover the lost system sensitivity are proposed. Measurements made with the GSFC 48 inch telescope (linear obscuration rate = 0.5) and the KPNO McMathe telescope (no obscuration) are given as examples.

Kostiuk, T.↗

Atmospheric correlation time measurements using coherent CO2 lidar

A pulsed TEA-CO2 lidar with coherent detection was used to measure the correlation time of backscatter from an ensemble of atmospheric aerosol particles which are illuminated by the pulsed radiation. The correlation time of the backscatter return signal is important in studies of atmospheric turbulence and its effects on optical propagation and backscatter. If the temporal coherence of the pulse is large enough, then the temporal coherence of the return signal is dominated by the turbulence and shear for a variety of interesting atmospheric conditions. Various techniques for correlation time measurement are discussed and evaluated.

Ancellet, G. M.↗

A real-time optical data processing device

The design, operation, and structure of the hybrid field effect light valve, a real-time input device for application to coherent optical data processing (CODP), is described. The device consists of a sandwich of thin films that electrically control the optical birefringence of a thin (2 micrometer) liquid crystal layer. It has high resolution (greater than 100 1/mm), contrast ratio (greater than 100:1), speed (10 sec on, 15 sec off) and input sensitivity (about 0.3 ergs/sq cm) in addition to cost and size advantages. Performance data for a laboratory model are presented.

Jacobson, A.↗

A new real-time non-coherent to coherent light image converter - The hybrid field effect liquid crystal light valve

A new, high-performance device has been developed for application to real-time coherent optical data processing. The new device embodies a CdS photoconductor, a CdTe light-absorbing layer, a dielectric mirror, and a liquid crystal layer sandwiched between indium-tin-oxide transparent electrodes deposited on optical quality glass flats. The noncoherent image is directed onto the photoconductor; this reduces the impedance of the photoconductor, thereby switching the ac voltage that is impressed across the electrodes onto the liquid crystal to activate the device. The liquid crystal is operated in a hybrid field effect mode. It utilizes the twisted nematic effect to create a dark off-state and the optical birefringence effect to create the bright on-state. The liquid crystal modulates the polarization of the coherent read-out light so an analyzer must be used to create an intensity modulated output beam.

Grinberg, J.↗

Reflective liquid crystal light valve with hybrid field effect mode

There is disclosed a high performance reflective mode liquid crystal light valve suitable for general image processing and projection and particularly suited for application to real-time coherent optical data processing. A preferred example of the device uses a CdS photoconductor, a CdTe light absorbing layer, a dielectric mirror, and a liquid crystal layer sandwiched between indium-tin-oxide transparent electrodes deposited on optical quality glass flats. The non-coherent light image is directed onto the photoconductor; this reduces the impedance of the photoconductor, thereby switching the AC voltage that is impressed across the electrodes onto the liquid crystal to activate the device. The liquid crystal is operated in a hybrid field effect mode. It utilizes the twisted nematic effect to create a dark off-state (voltage off the liquid crystal) and the optical birefringence effect to create the bright on-state. The liquid crystal thus modulates the polarization of the coherent read-out or projection light responsively to the non-coherent image. An analyzer is used to create an intensity modulated output beam.

Boswell, Donald D.↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional high temperature strain measurement system

Two-dimensional optical strain measurements on high temperature test specimens are presented. This two-dimensional capability is implemented through a rotatable sensitive strain axis. Three components of surface strain can be measured automatically, from which the first and second principal strains are calculated. One- and two-dimensional strain measurements at temperatures beyond 750 C with a resolution of 15 microstrain are demonstrated. The system is based on a one-dimensional speckle shift technique. The speckle shift technique makes use of the linear relationship between surface strain and the differential shift of laser speckle patterns in the diffraction plane. Laser speckle is a phase effect that occurs when spatially coherent light interacts with an optically rough surface. Since speckle is generated by any diffusely reflecting surface, no specimen preparation is needed to obtain a good signal. Testing was done at room temperature on a flat specimen of Inconel 600 mounted in a fatigue testing machine. A load cell measured the stress on the specimen before and after acquiring the speckle data. Strain components were measured at 0 C (parallel to the load axis) and at plus or minus 45 C, and plots indicate the calculated values of the first and second principal strains. The measured values of Young's modulus and Poisson's ratio are in good agreement with handbook values. Good linearity of the principal strain moduli at high temperatures indicate precision and stability of the system. However, a systematic error in the high-temperature test setup introduced a scale factor in the slopes of the two-dimensional stress-strain curves. No high temperature effects, however, have been observed to degrade speckle correlation.

Lant, Christian T.↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗

The effects of pointing errors on the performance of optical communications systems

Optical communications systems operating over interplanetary distances require the use of extremely narrow optical beams for maximum power concentration near the receiver. Consequently, pointing errors must be kept to a small fraction of a beamwidth to avoid severe deterioration in receiver performance, due to the decrease in received power associated with pointing errors. Mathematical moels required for studying the effects of random pointing errors were developed and applied to the problem of quantifying the effects of pointing errors on the performance of coherent and incoherent optical receivers.

Vilnrotter, V. A.↗

Induced Transparency and Absorption in Coupled Microresonators

We review the conditions for the occurrence of coherence phenomena in passive coupled optical microresonators. We derive the effective steady-state response and determine conditions for induced transparency and absorption in these systems.

Smith, David D.↗

Analysis of Optimum Heterodyne Receivers for Coherent Lidar Applications

A full analysis of the combined effects of all the noise sources of optical heterodyne receiver and the interaction between the competing control parameters of the receiver detector and pre-amplifier will be presented. This analysis provides the mean for true optimization of the coherent lidar receiver. The significance of the optimization of heterodyne receiver is shown for 2-micron coherent lidar.

Amzajerdian, Farzin↗

Magneto-opto-phononic inverse Faraday effect

Nonlinear frequency conversion processes, such as optical rectification, difference-frequency generation, and sum-frequency generation, are fundamental for producing electromagnetic radiation at diverse frequencies. In this work, we demonstrate that coherently excited infrared-active phonons can act as transducers for generating nonlinear magnetizations through phonon-magnon interactions, analogous to nonlinear optical frequency conversion. We derive analytical solutions for the time-dependent magnetizations arising from the second-order response to the electric field component of an ultrashort laser pulse. These solutions enable us to define second-order nonlinear magneto-electric susceptibilities, which describe rectification, impulsive excitation, and sum-frequency excitation of coherent magnons. Our theoretical framework naturally incorporates the conventional magneto-optic and phonon inverse Faraday effects and predicts a hybrid magneto-opto-phononic inverse Faraday effect involving photon-phonon-magnon scattering. This work highlights nonlinear phononics as a pathway for controlling magnetization in solids.

Landau-Lifschitz-Gilbert equation↗