Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold Water Pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improved Thermal-Insulation Systems for Low Temperatures

Improved thermal-insulation materials and structures and the techniques for manufacturing them are undergoing development for use in low-temperature applications. Examples of low-temperature equipment for which these thermal insulation systems could provide improved energy efficiency include storage tanks for cryogens, superconducting electric-power-transmission equipment, containers for transport of food and other perishable commodities, and cold boxes for low-temperature industrial processes. These systems could also be used to insulate piping used to transfer cryogens and other fluids, such as liquefied natural gas, refrigerants, chilled water, crude oil, or low-pressure steam. The present thermal-insulation systems are layer composites based partly on the older class of thermal-insulation systems denoted generally as multilayer insulation (MLI). A typical MLI structure includes an evacuated jacket, within which many layers of radiation shields are stacked or wrapped close together. Low-thermal-conductivity spacers are typically placed between the reflection layers to keep them from touching. MLI can work very well when a high vacuum level (less than 10(exp-4) torr) is maintained and utmost care is taken during installation, but its thermal performance deteriorates sharply as the pressure in the evacuated space rises into the soft vacuum range [pressures greater than 0.1 torr (greater than 13 Pa)]. In addition, the thermal performance of MLI is extremely sensitive to mechanical compression and edge effects and can easily decrease from one to two orders of magnitude from its ideal value even when the MLI is kept under high vacuum condition. The present thermal-insulation systems are designed to perform well under soft vacuum level, in particular the range of 1 to 10 torr. They are also designed with larger interlayer spacings to reduce vulnerability to compression (and consequent heat leak) caused by installation and use. The superiority of these systems is the synergistic effect of improvements in materials, design, and manufacture.

Fesmire, James E.↗

Counterpart Test on IBLOCA of 13% Cold Leg Break in ATLAS Facility

In the analysis for Loss-of-Coolant Accident (LOCA) as a design-basis accident (DBA) of a pressurized water reactor (PWR), redefinition of the break size based on the risk-informed regulation (RIR) is being extensively investigated due to the potential safety benefits. The pipe integrity and break frequency has been found to depend on the pipe size, so that a complete rupture of a smaller pipe such as a pressurizer surge-line or an emergency core cooling system (ECCS) nozzle is more probable than a double-ended guillotine break (DEGB) of primary coolant circuit piping. The scenario with the break of these pipes can be regarded as intermediate break (IB) LOCA. With an aim of expanding code validation to address safety issues of the IBLOCA and developing an evaluation model (EM) for full spectrum LOCA, the database for the IBLOCA test in an integral effect test (IET) facility is essential. In particular, an experimental data from the counterpart test can contribute to enhance our understanding on the phenomena and resolve the scaling issues in the scaled-down test facilities. The objective of this study is to investigate thermal hydraulic phenomena during the IBLOCA by the counterpart test for the 13% cold leg break in ATLAS facility, which was the A.2 test in the OECDATLAS project. This integral effect test would contribute to evaluate the scaling effect of the ATLAS design and test condition.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements

The aim of this paper is to present a new phantom for arc therapy, intensity-modulated radiation therapy (IMRT), and tomotherapy dose distribution measurement in pretreatment verification. The presented phantom is innovative for its use of water as the tissue equivalent material, together with a technical solution specifically designed to support radiographic or radiochromic film and ionization chambers in any desired position. The phantom comprise a Plexiglas container, whose present shape and dimensions offer the possibility to simulate a human torso or abdomen; the container can be filled with water by opening the upper cover. On the internal side of the cover, a set of carbon pipes can support film in the desired coronal, axial, or sagittal planes. At one of the two ends of the phantom, an ionization chamber can be positioned parallel to the rotation axis of the accelerator gantry in all possible positions within a 20 cm diameter cylinder, for film calibration purposes. Inhomogeneities can be inserted into the phantom using the same carbon pipes and plastic sheets used to support film. An example of vertebra-shaped inserts made of bone equivalent material is reported. Radiochromic film can be dipped in water, while radiographic film must be protected to prevent damage. To accomplish this, radiographic film is laminated using a cold laminating film. In order to assess the effects of both the lamination itself and the effects of water on laminated Kodak EDR2 film, the optical density (OD) of conventional, laminated, and laminated film immersed in water and exposed to a range of doses from 0 to 300 cGy were compared. The OD of the three samples receiving the same radiation dose did not present any significant difference, thus proving that laminated EDR2 film can also be used in water. A prerequisite for any dosimetric comparison between planned and measured data is a proper film to plan registration. The solution proposed here is an extrinsic in-plane registration technique using four reference points marked on each film in predefined positions. The four points and the millimeter scales fixed on the carbon pipes that support the film are designed and manufactured so as to transfer onto the film the same reference system used during the planning procedure, thus allowing a straightforward registration. Tests to assess the accuracy of the proposed registration method demonstrate that the distances between measured and intended marker positions, evaluated for coronal, axial, and sagittal planes, were about 1 mm for both anteroposterior and lateral projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]↗

Ocean thermal plant

A floating energy converter is described which uses large volumes of sea water to produce electrical power. In this plant, a fluid working medium is pumped to an evaporator where is is heated by a flow of warm surface sea water. The fluid in liquid form boils to a pressurized gas vapor which is routed to drive a turbine that, in turn, drives a generator for producing electricity. The gas vapor then enters a condenser immersed in cold sea water pumped from lower depths, condenses to its original liquid form, and then pumped to the evaporator to repeat the cycle. Modular components can be readily interchanged on the ocean thermal unit and inlet pipes for the sea water are provided with means for maintaining the pipes in alignment with the oncoming current. The modular construction allows for the testing of various components to provide a more rapid optimization of a standardized plant.

Owens, L. J.↗

Temperature-Operated Valve

Bimetallic valve stem positions orifice at end of inner pipe orifice so liquid flows to outlet when temperature lies within small range of preset value. If liquid too cold or too hot, orifices misaligned and liquid returned to source. Such as in shower, valve prevents outflow of dangerously hot or uncomfortably cold water.

Morrison, Andrew D.↗

The Effect of Flow on CO2 Corrosion of Self-Healing Metallic Coatings

Internal corrosion is an issue that affects natural gas pipelines, a significant part of the United States’ energy infrastructure. Over time, this corrosion has worn away longstanding pipelines due to the original construction materials used for the lines and impurities in the gas and liquid streams flowing through them. The main impurities in natural gas are H2O, CO2, H2S, and O2. One of the leading causes of corrosion is the CO2 dissolved in water, giving rise to carbonic acid formation, which can further dissolve the steel pipe. The National Energy Technology Laboratory (NETL) has been studying different solutions to this problem. One potential answer is a self-healing sacrificial metallic coating applied by a novel cold spray technique. This study explored the impact of flow on corrosion with this coating and carbon steel when exposed to a saturated CO2 environment by simulating the pipeline flow profile in a small-scale lab setting. The samples were evaluated using multiple electrochemical techniques that found corrosion rates and were backed up with surface analysis to conclude the behavior of the corrosion mechanisms. The cold spray coating exhibited steel corrosion protection under flow conditions. This study has significantly advanced our understanding of CO2 corrosion, particularly in the context of natural gas pipelines and coating design.

carbon steel↗

The Effect of Flow on CO2 Corrosion of Self-Healing Metallic Coatings

Internal corrosion is an issue that affects natural gas pipelines, a significant part of the United States energy infrastructure. Over time, this corrosion has worn away longstanding pipelines due to the original construction materials used for the lines and impurities in the gas and liquid streams flowing through them. The main impurities in natural gas are H2O, CO2, H2S, and O2. One of the leading causes of corrosion is the CO2 dissolved in water, giving rise to carbonic acid formation, which can further dissolve the steel pipe. The National Energy Technology Laboratory (NETL) has been studying different solutions to this problem. One potential answer is a self-healing sacrificial metallic coating applied by a novel cold spray technique. Previous studies at NETL have shown that the zinc-rich self-healing coating can withstand corrosion through passivation and create a barrier to the diffusion of corrosive species. This study explored the impact of flow on corrosion with this coating and carbon steel when exposed to a saturated CO2 environment by simulating the pipeline flow profile in a small-scale lab setting. The samples were evaluated using multiple electrochemical techniques that found corrosion rates and were backed up with surface analysis to conclude the behavior of the corrosion mechanisms.

CO2 corrosion↗

Energy saving potential of a two-pipe system for simultaneous heating and cooling of office buildings

This paper analyzes the performance of a novel two-pipe system that operates one water loop to simultaneously provide space heating and cooling with a water supply temperature of around 22 °C. To analyze the energy performance of the system, a simulation-based research was conducted. The two-pipe system was modelled using the equation-based Modelica modeling language in Dymola. A typical office building model was considered as the case study. Simulations were run for two construction sets of the building envelope and two conditions related to inter-zone air flows. To calculate energy savings, a conventional four-pipe system was modelled and used for comparison. The conventional system presented two separated water loops for heating and cooling with supply temperatures of 45 °C and 14 °C, respectively. Simulation results showed that the two-pipe system was able to use less energy than the four-pipe system thanks to three effects: useful heat transfer from warm to cold zones, higher free cooling potential and higher efficiency of the heat pump. In particular, the two-pipe system used approximately between 12% and 18% less total annual primary energy than the four-pipe system, depending on the simulation case considered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Production and Characterization of Additively Manufactured Radiator Panels with Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius (r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

thermal management↗

Production and Characterization of Additively Manufactured Radiator Panels With Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius ( r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

nuclear electric propulsion↗

Decommissioning of the 247-F Fuel Manufacturing Facility at the Savannah River Site (SRS)

Building 247-F at SRS was a roughly 110,000 ft{sup 2} two-story facility designed and constructed during the height of the cold war naval buildup to provide additional naval nuclear fuel manufacturing capacity in early 1980's. The manufacturing process employed a wide variety of acids, bases, and other hazardous materials. As the need for naval fuel declined, the facility was shut down and underwent initial deactivation, which was completed in 1990. All process systems were flushed with water and drained using the existing process drain valves. However, since these drains were not always installed at the lowest point in piping and equipment systems, a significant volume of liquid remained after initial deactivation. After initial deactivation, a non-destructive assay of the process area identified approximately 17 ({+-}100%) kg of uranium held up in equipment and piping. The facility was placed in Surveillance and Maintenance mode until 2003, when the decision was made to perform final deactivation, and then decommission the facility. The following lessons were learned as a result of the D and D of building 247-F. Successful D and D of a major radiochemical process building requires significant up-front planning by a team of knowledgeable personnel led by a strong project manager. The level of uncertainty and resultant risk to timely, cost effective project execution was found to be high. Examples of the types of problems encountered which had high potential to adversely impact cost and schedule performance are described below. Low level and sanitary waste acceptance criteria do not allow free liquids in waste containers. These liquids, which are often corrosive, must be safely removed from the equipment before it is loaded to waste containers. Drained liquids must be properly managed, often as hazardous or mixed waste. Tapping and draining of process lines is a dangerous operation, which must be performed carefully. The temptation to become complacent when breaking into lines is great. Incidents of personnel exposure to liquids during draining are likely. Records from the initial 1990 deactivation led early work planners to assume the facility was cold, dark and dry. This turned out to be a poor assumption. Work instructions had to be modified to require that engineers evaluate each of several hundred process lines to identify the low point, where a tap and drain system could be installed to allow positive verification that the line was empty before the line was cut for removal. During the period between facility shut down in 1990 and the start of final deactivation in 2003, roof leaks had developed, allowing rain water to enter building 247-F, which provided an environment for mold growth. Sampling confirmed the presence of Stachybotrys chartarum, a toxic indoor mold that grows on wet cellulosic material, such as drywall paper. D and D workers in areas where this hazard was identified were required to where proper personal protective equipment, which complicated work execution. Discovery of the potential presence of uniquely hazardous chemicals such as shock sensitive compounds and toxic uranium hexafluoride became issues which required investigation and special handling strategies. Team access to subject matter experts, who could quickly provide the required guidance for safe material handling, was critical to keeping the project on schedule. In old legacy facilities, it is possible that the D and D workers will be exposed to undocumented energy sources such as energized electrical conductors and pipes containing hazardous materials that originate outside the boundaries of the facility. Significant effort must be expended on adequate mechanical and electrical isolation. Subdividing the facility into well defined zones for which detailed zone-specific end points could be developed proved to be a highly effective project management strategy. Waste management must be carefully planned. The rate of waste generation as the facility is converted from a structure to waste can frequently exceed the D and D team's resources to characterize, package, store and transport the waste to a disposal facility in a timely manner. This can lead to schedule delays and/or increased project cost.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of porous medium on the high cycle temperature fluctuations in a mixing tee

Temperature fluctuations occur in the region where hot and cold fluids mix turbulently in the nuclear power plants. Temperature fluctuations cause thermal fatigue of piping systems. In the design of generation IV nuclear power plants, supercritical fluids are supposed to be used widely. This paper investigated the thermal striping phenomenon caused by the turbulent mixing in a supercritical water Tee. There are two key issues in the study of thermal striping phenomenon: One is to find the region which experiences the peak temperature fluctuation; the other is how to attenuate it. Porous media was used to attenuate the temperature fluctuations in this paper. The results show that porous media with proper parameters in a tee can reduce the temperature fluctuations magnificently. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel techniques and devices for in-situ film coatings of long, small diameter tubes or elliptical and other surface contours

In this study, devices and techniques that can, via physical vapor deposition,coat various surface contours or very long small aperture pipes, are described. Recently, a magnetron mole was developed in order to in-situ coat accelerator tube sections of the Brookhaven National Lab relativistic heavy ion collider that have 7.1 cm diameter with access points that are 500 m apart, for copper coat the accelerator vacuum tube in order to alleviate the problems of unacceptable ohmic heating and of electron clouds. A magnetron with a 50 cm long cathode was designed fabricated and successfully operated to copper coat a whole assembly containing a full-size, stainless steel, cold bore, of the accelerator magnet tubing connected to two types bellows, to which two additional pipes made of accelerator tubing were connected. The magnetron is mounted on a carriage with spring loaded wheels that successfully crossed bellows and adjusted for variations in vacuum tube diameter, while keeping the magnetron centered. Electrical power and cooling water were fed through a cable bundle. The umbilical cabling system, which is enclosed in a flexible braided metal sleeve, is driven by a motorized spool. To increase cathode lifetime, movable magnet package was developed, and thickest possible cathode was made, with a rather challenging target to substrate distance of less than 1.5 cm. Optimized process to ensure excellent adhesion was developed. Coating thickness of 10 μm Cu passed all industrial tests and even exceeded maximum capability of a 12 kg pull test fixture. Room temperature radio frequency (RF) resistivity measurement indicated that 10 μm Cu coated stainless steel accelerator tube has conductivity close to copper tubing. Work is in progress to repeat the RF resistivity measurement at cryogenic temperatures. Over 20 years ago, a device using multi axis robotic manipulators controlling separate robotic assemblies resulted in nine-axes of motion combined with conformal shape of the cathodes that can adapt to various curved surface contours was developed and successfully used for depositing optical coating on aircraft canopies. The techniques can be utilized for in situ coating of elliptical and other surface contour RF cavities and long beam pipes with thick superconducting films. Plans are to incorporate ion assisted deposition in those techniques for attaining dense, adherent and defect free coatings.

43 PARTICLE ACCELERATORS↗

Mixing Study for the Modification of H-Canyon Tank 31 and 32 Recirculation Lines Via M-Star®

As a part of the Accelerated Basin De-Inventory (ABD) program Tanks 31 or 32 will be re-purposed to support increasing the number of annual Material Test Reactor (MTR) and High Flux Isotope Reactor (HFIR) dissolutions. The proposed plan will allow Tanks 31 or 32 to be used as the dissolver cold chemical solution makeup tank and storage tank. The dissolver cold chemicals are 50% nitric acid, process water, mercuric nitrate, and gadolinium nitrate. Tanks 31 and 32 are 9 ft. (outer diameter) x 36 ft, horizontal, and can hold approximately 56,000 liters (15,000 gallons) each. One full volume of Tanks 31 or 32 can support 4 HFIR 6.4D equivalent batches. Both tanks are equipped with liquid level instrumentation. Tank 31 is equipped with 1 pump used for transfer and recirculation while Tank 32 is equipped with two pumps, one for transfer and the other for recirculation. Each of the pumps is equipped with sample taps. The tanks do not have specific gravity instrumentation, an agitator, or a sampler. Piping modifications will also be performed to supply the tank with cold chemicals. The current dissolver chemical composition is 5.0 -8.5M HNO3 and ~0.2 g Gd/L. The recirculating pump connected to Tank 31 is rated for a flowrate 175 gpm while the pump connected to Tank 32 is rated for a flowrate 50 gpm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spacecraft Crew Cabin Condensation Control

A report discusses a new technique to prevent condensation on the cabin walls of manned spacecraft exposed to the cold environment of space, as such condensation could lead to free water in the cabin. This could facilitate the growth of mold and bacteria, and could lead to oxidation and weakening of the cabin wall. This condensation control technique employs a passive method that uses spacecraft waste heat as the primary wallheating mechanism. A network of heat pipes is bonded to the crew cabin pressure vessel, as well as the pipes to each other, in order to provide for efficient heat transfer to the cabin walls and from one heat pipe to another. When properly sized, the heat-pipe network can maintain the crew cabin walls at a nearly uniform temperature. It can also accept and distribute spacecraft waste heat to maintain the pressure vessel above dew point.

Carrillo, Laurie Y.↗

Lifetime estimation of a BWR core shroud in terms of IGSCC

The continued operation of aging Boiling Water Reactors (BWRs) worldwide requires gradually increasing cost of inspection, maintenance, and repair. Intergranular Stress Corrosion Cracking (IGSCC) in sensitized austenitic stainless steel piping first became a major issue for BWRs in the 1980s, resulting in recognition of the susceptibility of reactor internals to IGSCC. Shroud cracking identified in 1993–1994 confirmed that IGSCC of internals is a significant issue for BWRs. IGSCC is a time-dependent, material degradation process, which is caused and accelerated by the presence of residual stresses, material sensitization, irradiation, cold work, elevated temperature, and corrosive environments. This paper emphasizes the importance of accounting for corrosive environments, or more exactly, electrochemical phenomena in modelling IGSCC and predicting the service life of BWR in-vessel components, and stresses the necessity of performing such modeling not just for a single state point under full power conditions, but for the whole operating history of the reactor, including startups and shutdowns. Overall, this paper demonstrates that ignoring electrochemical considerations may result in underestimating component lifetime and lead to unnecessary expenses for inspection and repair.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Multi-Environment Thermal Control System With Freeze-Tolerant Radiator

Future space exploration missions require advanced thermal control systems (TCS) to dissipate heat from spacecraft, rovers, or habitats operating in environments that can vary from extremely hot to extremely cold. A lightweight, reliable TCS is being developed to effectively control cabin and equipment temperatures under widely varying heat loads and ambient temperatures. The system uses freeze-tolerant radiators, which eliminate the need for a secondary circulation loop or heat pipe systems. Each radiator has a self-regulating variable thermal conductance to its ambient environment. The TCS uses a nontoxic, water-based working fluid that is compatible with existing lightweight aluminum heat exchangers. The TCS is lightweight, compact, and requires very little pumping power. The critical characteristics of the core enabling technologies were demonstrated. Functional testing with condenser tubes demonstrated the key operating characteristics required for a reliable, freeze-tolerant TCS, namely (1) self-regulating thermal conductance with short transient responses to varying thermal loads, (2) repeatable performance through freeze-thaw cycles, and (3) fast start-up from a fully frozen state. Preliminary coolant tests demonstrated that the corrosion inhibitor in the water-based coolant can reduce the corrosion rate on aluminum by an order of magnitude. Performance comparison with state-of-the-art designs shows significant mass and power saving benefits of this technology.

Chen, Weibo↗