Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collector angles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

Source record↗

Indoor test for thermal performance evaluation on life sciences engineering (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a life sciences double-glazed air solar collector under simulated conditions is discussed. These tests were made using the Marshall Space Flight Center's solar simulator. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

Performance evaluations of a liquid solar collector

Report presents procedures and results of thermal performance tests on single-covered liquid solar collector under simulated comditions. Test conditions and data are given in tables and graphs for stagnation tests and thermal performance test. In addition, time-constant test and incident-angle modifier test were conducted to determine transient effect and incident-angle effect. Results of collector load tests are also given.

Shih, K.↗

Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector

The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

Shih, K.↗

Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector

The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Indoor test for thermal performance evaluation of Sunworks (liquid) solar collector

Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

A generalized correlation of experimental flat-plate collector performance

A generalized correlation of flat-plate collector performance obtained by outdoor and indoor test methods is presented. This correlation shows that the indoor (simulator) test approach is a special case of the general situation of variable solar conditions. The important feature of the generalized correlation is that it permits a separation of the solar variables (flux, incident angle, etc.) which affect collector performance from the collector parameters (absorptance, transmittance, heat loss, etc.) which also affect collector performance and which are uniquely part of a given collector design. The correlation permits an evaluation of the relative merits of using instantaneous, hourly and daily collector efficiencies in obtaining a good collector correlation. The question of the transient behavior outdoors of a collector is an important part of determining whether to use instantaneous, hourly or daily efficiency values in a correlation approach. Correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs, (2) collector performance prediction under conditions that differ from the conditions of the test program, and (3) monitoring performance degradation effects.

Simon, F. F.↗

Interaction of high-power laser radiation with low-density polymer aerogels

The interaction of high-power subnanosecond laser pulses with low-density targets of cellulose triacetate polymer is considered. An Nd-glass laser setup provides a focal spot intensity of over 10{sup 14} W cm{sup −2}. An investigation is made of absorption of laser radiation, laser-to-X-ray energy conversion, spectra of ions emitted from the plasma, transmission of laser radiation through the target and plasma, as well as volume heating of the target material. It is experimentally determined that the laser energy conversion efficiency to X-rays with photon energies of a few Kiloelectronvolts decreases with increasing target material density. With the use of targets of density 10 mg cm{sup −3} this efficiency is two times lower in comparison to 2 mg cm{sup −3} density targets. The duration and amplitude of laser pulses transmitted through the target decreases with increasing column target density (the product of target material density and its thickness). The spectra of ions emitted from low-density target plasmas are recorded using ion collectors positioned at different angles relative to the direction of laser beam propagation as well as a high-resolution Thomson mass spectrometer. The ion flux and ion energies are found to increase with increasing target material density. The peak of the ion energy spectrum is shifted towards higher energies with increasing laser radiation intensity. (interaction of laser radiation with matter. laser plasma)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low cost vee-trough evacuated tube collector module

A low cost solar collector capable of operating at 150-200 C is described. An evacuated tube receiver is combined with asymmetric vee-trough concentrators. Peak efficiencies of about 40% at 120 C and 30% at 180 C are expected. Predicted future collector cost is $70/sq m which yields an energy cost of $4.20/GJ at 120 C. During the development of the vee trough/evacuated tube collector both mathematical models to predict thermal and optical performance were developed and tests run to verify theory. The asymmetric vee trough concentrator increases the solar flux intensity for an average value of 2 for year-round performance. Optimized collector module has reflector angles of 55 deg/85 deg. The aperture plane is tilted to the latitude. The reflector is made of electropolished aluminum. The supporting frame is formed by bending sheet metal. Evacuated tube receivers are Pyrex, 15 cm diam and 2.4 m long. The module has 12 tubes on right and left sides altogether. Attainable operation at temperatures on the order of 150-200 C are suitable for absorption refrigeration and power generation via Rankine engines.

Selcuk, M. K.↗

Nozzle diffuser for use with an open test section of a wind tunnel

The nozzle diffuser has an inlet in fluid communication with the narrowed inlet of an open test chamber in a conventional wind tunnel. The nozzle diffuser has a passageway extending from its inlet to an outlet in communication with the open test section. The passageway has an internal cross sectional area which increases from its inlet to its outlet and which may be defined by top and bottom isosceles trapezoid walls of a particular flare angle and by isosceles trapezoid side walls of a different flare angle. In addition, a collector having a decreasing internal cross sectional area from inlet to outlet may be provided at the opposite end of the test chamber such that its outlet is in communication with a diffuser located at this outlet.

Barna, P. Stephen↗

Analytical Approach Treating Three-Dimensional Geometrical Effects of Parabolic Trough Collectors: Preprint

An analytical approach, as an extension of one newly developed method -- First-principle OPTical Intercept Calculation (FirstOPTIC) -- is proposed to treat the geometrical impact of three-dimensional (3-D) effects on parabolic trough optical performance. The mathematical steps of this analytical approach are presented and implemented numerically as part of the suite of FirstOPTIC code. Inaddition, the new code has been carefully validated against ray-tracing simulation results and available numerical solutions. This new analytical approach to treating 3-D effects will facilitate further understanding and analysis of the optical performance of trough collectors as a function of incidence angle.

14 SOLAR ENERGY↗

An experimental investigation with artificial sunlight of a solar hot-water heater

Thermal performance measurements were made of a commercial solar hot water heater in a solar simulator to determine basic performance characteristics of a traditional type of flat plate collector, with and without side reflectors (to increase the solar flux). Information on each of the following was obtained; (1) the effect of flow and incidence angle on the efficiency of a flat plate collector (but only without side reflectors); (2) transient performance under flow and nonflow conditions; (3) the effectiveness of reflectors to increase collector efficiency for a zero radiation angle at fluid temperatures required for solar air conditioning; and (4) the limits of applicability of a collector efficiency correlation based on the Hottel Whillier equation.

Simon, F. F.↗

An experimental investigation with artificial sunlight of a solar hot-water heater

Thermal performance measurements were made of a commercial solar hot-water heater in a solar simulator. The objective of the test was to determine basic performance characteristics of a traditional type of flat-plate collector, with and without side reflectors (to increase the solar flux). Due to the fact that collector testing in the solar simulator permits control of the variables that affect collector performance, it was possible to obtain information on each of the following: (1) the effect of flow and incidence angle on the efficiency of a flat-plate collector (but only without side reflectors), (2) transient performance under flow and nonflow conditions, (3) the effectiveness of reflectors in increasing collector efficiency for a zero radiation angle at fluid temperatures required for solar air conditioning, and (4) the limits of applicability of a collector efficiency correlation based on the Hottel-Whillier equation (1958).

Simon, F. F.↗

Direct normal irradiance related definitions and applications: The circumsolar issue

The direct irradiance received on a plane normal to the sun, called direct normal irradiance (DNI), is of particular relevance to concentrated solar technologies, including concentrating solar thermal plants and concentrated photovoltaic systems. Following various standards from the International Organization for Standardization (ISO), the DNI definition is related to the irradiance from a small solid angle of the sky, centered on the position of the sun. Half-angle apertures of pyrheliometers measuring DNI have varied over time, up to ≈10°. The current recommendation of the World Meteorological Organization (WMO) for this half-angle is 2.5°. Solar concentrating collectors have an angular acceptance function that can be significantly narrower, especially for technologies with high concentration ratios. The disagreement between the various interpretations of DNI, from the theoretical definition used in atmospheric physics and radiative transfer modeling to practical definitions corresponding to specific measurements or conversion technologies is significant, especially in the presence of cirrus clouds or large concentration of aerosols. Under such sky conditions, the circumsolar radiation—i.e. the diffuse radiation coming from the vicinity of the sun—contributes significantly to the DNI ground measurement, although some concentrating collectors cannot utilize the bulk of it. These issues have been identified in the EU-funded projects MACC-II (Monitoring Atmospheric Composition and Climate-Interim Implementation) and SFERA (Solar Facilities for the European Research Area), and have been discussed within a panel of international experts in the framework of the Solar Heating and Cooling (SHC) program of the International Energy Agency’s (IEA’s) Task 46 “ Solar Resource Assessment and Forecasting ”. In accordance with these discussions, the terms of reference related to DNI are specified here. The important role of circumsolar radiation is evidenced, and its potential contribution is evaluated for typical atmospheric conditions. Thus, thorough analysis of performance of concentrating solar systems, it is recommended that, in addition to the conventional DNI related to 2.5° half-angle of today’s pyrheliometers, solar resource data sets also report the sunshape, the circumsolar contribution or the circumsolar ratio (CSR).

14 SOLAR ENERGY↗

Improved TWTs for electronic countermeasure application

Some efforts in the development of a multistage depressed collector (MSDC) are reviewed. The MSDC is to operate in an electronic countermeasure system (ECM) with minimum overall efficiency in the range 35 to 50%. The effects of interception, harmonic output, and skin effect losses on the design of high-efficiency tubes with a MSDC are briefly discussed. Future experimental work will attempt to put a multistage depressed collector on a 400-watt CW 4.8 to 9.6-GHz helix TWT. By using a unique valve assembly, different collector configurations can be tested while maintaining the circuit under vacuum. The work will determine the sensitivity of overall tube efficiency to the number of collector, length of the collector, aperture size, and plate angle.

Laycock, D. E.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗