Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collimator efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Rocket and Laboratory Studies in Astronomy

This report covers the period from March 1, 2001 to August 31, 2004. This grant was the continuation of NASA grant NAG5-5122 and supported the Johns Hopkins sounding rocket program that had its roots in the 1960s. The emphasis of this program has been the development of instrumentation for far-ultraviolet astronomy, the training of graduate students in all aspects of a space mission, and the application of these techniques to timely scientific problems. During this period we completed the fabrication of our new long-slit dual-order spectrograph (LIDOS), and successfully flew it on a Black Brant sounding rocket on December 16, 2003 (36.208 UG). The targets were the bright star gamma-Cassiopeiae and its surrounding reflection nebulae, IC 59 and IC 63. We also continued the analysis of the data from our previous flight to study the reflection nebula IC 405 (36.198 UG), which revealed a far-ultraviolet nebular scatter to stellar flux ratio that, contrary to expectations, rises steeply toward the blue. Verifying this result required extensive post-flight analysis and calibration of the Faint Object Telescope FOT) payload, which entailed measuring the telescope mirror reflectivities, the absolute efficiency of the spectrograph, and the telescope point spread function, using a new vacuum collimator developed as part of former graduate student Eric Burgh's Ph.D. dissertation. This work, being done with graduate student Kevin France, has been completed and a paper describing the results has been accepted for publication by the Astrophysical Journal. We have also continued a number of laboratory calibration studies and design efforts.

Feldman, Paul D.↗

Grating rhomb diode laser power combiner

A compact device for spectrally combining many laser-diode beams into a single multi-wavelength beam has been developed for use in NASA's intersatellite communications programs. The prototype device combines seven 30 milliwatt beams into a single beam with 70 percent efficiency producing an output of approximately 150 milliwatts. All beams are coaxial and can be collimated with a single transmitter optical system. The combining technique is relatively insensitive to drifts in the laser-diode wavelength and provides both increased power output and laser-diode source redundancy. Combination of more than 100 laser-diodes producing an output greater than 5 watts appears feasible with this technique.

Minott, Peter O.↗

Studies of Fission Fragment Rocket Engine Propelled Spacecraft

The NASA Office of Chief Technologist has funded from FY11 through FY14 successive studies of the physics, design, and spacecraft integration of a Fission Fragment Rocket Engine (FFRE) that directly converts the momentum of fission fragments continuously into spacecraft momentum at a theoretical specific impulse above one million seconds. While others have promised future propulsion advances if only you have the patience, the FFRE requires no waiting, no advances in physics and no advances in manufacturing processes. Such an engine unequivocally can create a new era of space exploration that can change spacecraft operation. The NIAC (NASA Institute for Advanced Concepts) Program Phase 1 study of FY11 first investigated how the revolutionary FFRE technology could be integrated into an advanced spacecraft. The FFRE combines existent technologies of low density fissioning dust trapped electrostatically and high field strength superconducting magnets for beam management. By organizing the nuclear core material to permit sufficient mean free path for escape of the fission fragments and by collimating the beam, this study showed the FFRE could convert nuclear power to thrust directly and efficiently at a delivered specific impulse of 527,000 seconds. The FY13 study showed that, without increasing the reactor power, adding a neutral gas to the fission fragment beam significantly increased the FFRE thrust through in a manner analogous to a jet engine afterburner. This frictional interaction of gas and beam resulted in an engine that continuously produced 1000 pound force of thrust at a delivered impulse of 32,000 seconds, thereby reducing the currently studied DRM 5 round trip mission to Mars from 3 years to 260 days. By decreasing the gas addition, this same engine can be tailored for much lower thrust at much higher impulse to match missions to more distant destinations. These studies created host spacecraft concepts configured for manned round trip journeys. While the vehicles are very large, they are primarily made up of a habitat payload on one end, the engine on the opposite end and a connecting spine containing radiator acreage needed to reject the heat of this powerful, but inefficient engine. These studies concluded that the engine and spacecraft are within today's technology, could be built, tested, launched on several SLS launchers, integrated, checked out, maintained at an in-space LEO base, and operated for decades just as Caribbean cruise ships operate today. The nuclear issues were found to be far less daunting that [than for] current nuclear engines. The FFRE produces very small amounts of radioactive efflux compared to their impulse, easily contained in an evacuated "bore-hole" test site. The engine poses no launch risk since it is simply a structure containing no fissionable material. The nuclear fuel is carried to orbit in containers highly crash-proofed for launch accidents from which it, in a liquid medium, is injected into the FFRE. The radioactive exhaust, with a velocity above 300 kilometers per second rapidly leaves the solar system.

Werka, Robert O.↗

Hubble Space Telescope: Faint object spectrograph instrument handbook. Version 1.1

The Faint Object Spectrograph (FOS) has undergone substantial rework since the 1985 FOS Instrument Handbook was published, and we are now more knowledgeable regarding the spacecraft and instrument operations requirements and constraints. The formal system for observation specification has also evolved considerably, as the GTO programs were defined in detail. This supplement to the FOS Instrument Handbook addresses the important aspects of these changes, to facilitate proper selection and specification of FOS observing programs. Since the Handbook was published, the FOS red detector has been replaced twice, first with the best available spare in 1985 (which proved to have a poor, and steadily degrading red response), and later with a newly developed Digicon, which exhibits a high, stable efficiency and a dark-count rate less than half that of its predecessors. Also, the FOS optical train was realigned in 1987-88 to eliminate considerable beam-vignetting losses, and the collimators were both removed and recoated for greater reflectivity. Following the optics and detector rework, the FOS was carefully recalibrated (although only ambient measurements were possible, so the far-UV characteristics could not be re-evaluated directly). The resulting efficiency curves, including improved estimates of the telescope throughput, are shown. A number of changes in the observing-mode specifications and addition of several optional parameters resulted as the Proposal Instructions were honed during the last year. Target-brightness limitations, which have only recently been formulated carefully, are described. Although these restrictions are very conservative, it is imperative that the detector safety be guarded closely, especially during the initial stages of flight operations. Restrictions on the use of the internal calibration lamps and aperture-illumination sources (TA LEDs), also resulting from detector safety considerations, are outlined. Finally, many changes have been made to the instructions for target acquisition specification.

Ford, Holland C.↗

Two-Pass, Diode-Pumped Nd:YAG Slab Laser Head

Neodymium/yttrium aluminum garnet (Nd:YAG) ring-laser head designed for compactness, simplicity, and increased efficiency for side pumping by diode lasers. Laser head includes two linear arrays of diode lasers, two fused-silica collimating rods, and Nd:YAG slab. Slab mounted on finned copper block, providing good thermal dissipation.

Coyle, D. Barry↗

Preliminary Results from Small-Pixel CdZnTe and CdTe Arrays

We have evaluated 2 small-pixel (0.75 mm) Cadmium-Zinc-Telluride arrays, and one Cadmium-Telluride array, all fabricated for MSFC by Metorex (Finland) and Baltic Science Institute (Riga, Latvia). Each array was optimized for operating temperature and collection bias. It was then exposed to Cadmium-109 and Iron-55 laboratory isotopes, to measure the energy resolution for each pixel and was then scanned with a finely-collimated x-ray beam, of width 50 micron, to examine pixel to pixel and inter-pixel charge collections efficiency. Preliminary results from these array tests will be presented.

Ramsey, B. D.↗

Grazing incidence telescopes - A new class for soft X-ray and EUV spectroscopy

A new class of grazing incidence telescopes is identified, and its advantages for stellar spectroscopy are discussed. In particular, three types of telescope geometry consisting of a primary and a secondary, both at grazing incidence, are proposed. Type I delivers a converging beam having a real focus; type II delivers a diverging beam from a virtual focus, and type III delivers a collimated beam concentrated relative to the primary aperture. The three telescope types are shown to possess unique properties which improve the efficiency and shorten the length of soft X-ray/EUV spectrographs.

Hettrick, M. C.↗

In Situ Aerosol Detector

An affordable technology designed to facilitate extensive global atmospheric aerosol measurements has been developed. This lightweight instrument is compatible with newly developed platforms such as tethered balloons, blimps, kites, and even disposable instruments such as dropsondes. This technology is based on detection of light scattered by aerosol particles where an optical layout is used to enhance the performance of the laboratory prototype instrument, which allows detection of smaller aerosol particles and improves the accuracy of aerosol particle size measurement. It has been determined that using focused illumination geometry without any apertures is advantageous over using the originally proposed collimated beam/slit geometry (that is supposed to produce uniform illumination over the beam cross-section). The illumination source is used more efficiently, which allows detection of smaller aerosol particles. Second, the obtained integral scattered light intensity measured for the particle can be corrected for the beam intensity profile inhomogeneity based on the measured beam intensity profile and measured particle location. The particle location (coordinates) in the illuminated sample volume is determined based on the information contained in the image frame. The procedure considerably improves the accuracy of determination of the aerosol particle size.

Vakhtin, Andrei↗

Solar simulator for solar dynamic space power system testing

Planned vacuum tank testing of a solar dynamic space power system requires a solar simulator. Several solar simulators were previously built and used for vacuum tank testing of various space systems. However, the apparent solar subtense angle, i.e., the angular size of the apparent sun as viewed from the experiment, of these solar simulators is too large to enable testing of solar dynamic systems. A new design was developed to satisfy the requirements of the solar dynamic testing. This design provides 1.8 kW/m(sup 2) onto a 4.5M diameter test area from a source that subtends only 1 deg, full cone angle. Key features that enable this improved performance are (1) elimination of the collimating mirror commonly used in solar simulators to transform the diverging beam into a parallel beam; (2) a redesigned lamp module that has increased efficiency; and (3) the use of a segmented reflective surface to combine beams from several individual lamp modules at the pseudosun. Each segment of this reflective surface has complex curvature to control the distribution of light. By developing a new solar simulator design for testing of the solar dynamic system instead of modifying current designs, the initial cost was cut in half, the efficiency was increased by 50 percent reducing the operating costs by one-third, and the volume occupied by the solar simulator was reduced by a factor of 10.

Jefferies, Kent S.↗

Thermal Lens Measurement in Diode-Pumped Nd:YAG Zig-Zag Slab

A major advantage that solid state zig-zag slab lasers have over conventional rod-based designs is that a much weaker thermal lens is produced in the slab when side-pumped with Quasi-CW laser diode arrays, particularly if the pump radiation is kept well away from the Brewster-cut ends. This paper reports on a rather strong thermal lens produced when diode pump radiation is collimated into a narrow portion of the zig-zag slab. The collimation of multi-bar pump packages to increase brightness and improve overlap is a direct consequence of designs which seek to maximize performance and efficiency. Our slab design employed a 8.1 cm x 2.5 mm x 5 mm slab with opposing Brewster end faces. It was pumped through the 2.5 mm direction by seven laser diode array packages, each housing four 6OW diode bars, 1 cm in width. The pump face, anti-reflection (AR) coated at 809 nm, was 6.8 cm in width and the 8.1 cm opposing side, high-reflection (HR) coated at 809 nm, reflected the unabsorbed pump beam for a second pass through the slab.

Smoak, M. C.↗

Efficient wire-grid duplexer-polarized for CO2 lasers

Chromium wire grid duplexer-polarizer for 10 micrometer carbon dioxide laser communication system is produced by depositing photo-resist film onto silicon substrate, grating by two collimated cadmium helium laser beams, covering of surface with thin chromium layer, and subsequent stripping of uncoated portion to expose etched wires.

Cheo, P. K.↗

Method of and means for testing a glancing-incidence mirror system of an X-ray telescope

An apparatus was designed for measuring the resolution and efficiency of a glancing-incidence mirror system having an even number of coaxial and confocal reflecting surfaces for use in an X-ray telescope. A collimated beam of X-rays is generated by an X-ray laser and directed along the axis of the system so that the beam is incident on the reflecting surfaces and illuminates a predetermined area. An X-ray detector, such as a photographic film, is located at the common focus of the surfaces so that the image produced by the X-rays may be compared with a test pattern interposed between the laser and the system.

Dailey, C. C.↗

Efficient IR Transmission Diffraction Grating for Circularly Polarized Light

Numerical methods, using rigorous coupled wave theory, are used to design rectangular relief diffraction gratings for an infrared application which requires comparable first order efficiencies in the TE and TM polarization states. The depth, period, and fill factor of the grating are varied to identify optimal two level binary lamellar grating profiles which predict efficiencies for individual TM and TE polarizations above 75 percent, while keeping the difference between the two efficiencies within 10 percent. The application at hand is a rotating, transmissive diffractive scanner for space-based coherent lidar. The operating wavelength is 2.0 microns. A collimated, circularly polarized beam is incident on the diffractive scanner at the Bragg angle; 30 and 45 degree beam deflection angles being studied. Fused silica is the substrate material of choice. Selected designs are fabricated on 3 inch fused silica substrates using lithographic methods. The performance of the test pieces is measured and compared to theoretical predictions.

Cole, Helen↗

Crystal structure and density of helium to 232 kbar

The properties of helium and hydrogen at high pressure are topics of great interest to the understanding of planetary interiors. These materials constitute 95 percent of the entire solar system. A technique was presented for the measurement of X-ray diffraction from single-crystals of low-Z condenses gases in a diamond-anvil cell at high pressure. The first such single-crystal X-ray diffraction measurements on solid hydrogen to 26.5 GPa were presented. The application of this technique to the problem of the crystal structure, equation of state, and phase diagram of solid helium is reported. Crucial for X-ray diffraction studies of these materials is the use of a synchrotron radiation source which provides high brillance, narrow collimation of the incident and diffracted X-ray beams to reduce the background noise, and energy-dispersive diffraction techniques with polychromatic (white) radiation, which provides high detection efficiency.

Mao, H. K.↗

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.↗

Imaging Spectrometers Using Concave Holographic Gratings

Imaging spectroscopy combines the spatial attributes of imaging with the compositionally diagnostic attributes of spectroscopy. For spacebased remote sensing applications, mass, size, power, data rate, and application constrain the scanning approach. For the first three approaches, substantial savings in mass and size of the spectrometer can be achieved in some cases with a concave holographic grating and careful placement of an order-sorting filter. A hologram etched on the single concave surface contains the equivalent of the collimating, dispersing, and camera optics of a conventional grating spectrometer and provides substantial wavelength dependent corrections for spherical aberrations and a flat focal field. These gratings can be blazed to improve efficiency when used over a small wavelength range or left unblazed for broadband uniform efficiency when used over a wavelength range of up to 2 orders. More than 1 order can be imaged along the dispersion axis by placing an appropriately designed step order-sorting filter in front of the one- or two-dimensional detector. This filter can be shaped for additional aberration corrections. The VIRIS imaging spectrometer based on the broadband design provides simultaneous imaging of the entrance slit from lambda = 0.9 to 2.6 microns (1.5 orders) onto a 128 x 128 HgCdTe detector (at 77 K). The VIRIS spectrometer was used for lunar mapping with the UH 24.in telescope at Mauna Kea Observatory. The design is adaptable for small, low mass, space based imaging spectrometers.

Gradie, J.↗

Broadband, Achromatic Twyman-Green Interferometer

Improved Twyman-Green interferometer used in wave-front testing optical components at wavelengths from 200 to 1,100 nm, without having to readjust focus when changing wavelength. Built to measure aberrations of light passing through optical filters. Collimating and imaging lenses of classical Twyman-Green configuration replaced by single spherical mirror. Field lens replaced by field mirror. Mirrors exhibit no axial chromatic aberration and made to reflect light efficiently over desired broad range of wavelengths.

Steimle, Lawrence J.↗

Bulk and integrated acousto-optic spectrometers for molecular astronomy with heterodyne spectrometers

A survey of acousto-optic spectrometers for molecular astronomy is presented, noting a technique of combining the acoustic bending of a collimated coherent light beam with a Bragg cell followed by an array of sensitive photodetectors. This acousto-optic spectrometer has a large bandwidth, a large number of channels, high resolution, and is energy efficient. Receiver development has concentrated on high-frequency heterodyne systems for the study of the chemical composition of the interstellar medium. RF spectrometers employing acousto-optic diffraction cells are described. Acousto-optic techniques have been suggested for applications to electronic warfare, electronic countermeasures and electronic support systems. Plans to use integrated optics for the further miniaturization of acousto-optic spectrometers are described. Bulk acousto-optic spectrometers with 300 MHz and 1 GHz bandwidths are being developed for use in the back-end of high-frequency heterodyne receivers for astronomical research.

Chin, G.↗