SEARCH · Search NASA
Results for “Compact heat exchanger”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability (CRADA NFE-21-08888 Final Report)
Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. Eck Industries successfully casted Al-Ce-Mg heat exchanger. ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.
Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability
• Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. • Eck Industries successfully casted Al-Ce-Mg heat exchanger. • ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. • Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. • ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. • In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.
Tensile Performance of Diffusion Bonded Haynes 230 Alloy for Use in a Compact Heat Exchanger
Presented by NETL at TMS 2020, 02/20
Mechanical Performance of Diffusion Bonded 316 Stainless Steel for Use in a Hybrid Compact Heat Exchanger
Presented by NETL at TMS Annual Meeting 2020, 02/20
Compact Heat Exchangers for the Stringent Operating Requirements of CSP Systems
Explore the source record for details and available documents.
Flow assisted anti-fouling geometries for compact heat exchangers
A header for a heat exchanger and method for cleaning a heat exchanger in a loop without disconnecting loop components is provided. The header is in flow communication with the heat exchanger for distributing fluid through a plurality of adjacent channels. The header is connected between a main heat exchanger inlet nozzle and a channel flow distributor. A filter element is disposed within the header between the nozzle and channel flow distributor. Under normal operation, the filter element removes particulates and fouling material from the main flow stream before it enters the heat exchanger channels. During the cleaning process, fluid is injected on or through the filter element to remove particulates and fouling material through at least one outlet port. The header arrangement allows the filter element to be ‘cleaned in place’ without draining the system and disconnecting the heat exchanger or other components from the flow loop.
Compact Ceramic Heat Exchangers for MMR
Explore the source record for details and available documents.
Experimental Analysis of Salt Hydrate Latent Heat Thermal Energy Storage System With Porous Aluminum Fabric and Salt Hydrate as Phase Change Material With Enhanced Stability and Supercooling
Phase change materials (PCMs), especially salt hydrates possess high volumetric energy storage capacity in their transition temperature range. These materials are used in applications where it is necessary to store thermal energy due to temporary load shift between demand and availability. Thus, possible applications are HVAC, recovery of waste heat, and defense thermal management. Despite salt hydrates potential, the practical feasibility of latent heat storage with salt hydrates is limited due to low power rating, supercooling, phase segregation, and long-term stability. Its low power rating and long-term stability limits its application in most applications. This work experimentally validates the stability and thermal performance of a compact heat exchanger charged with salt hydrate during melting and freezing. The compact heat exchanger was designed with fins on both the heat transfer fluid (HTF) and salt hydrate PCM side. The thermal performance of the latent heat thermal energy storage system (LHTESS) was evaluated for various operating conditions. The results show that LHTESS could achieve an average heat transfer coefficient of 124 and 87 W/(m2 K) during melting and solidification, respectively. The stability of the system in suppressing supercooling was validated over 800 cycles with nucleating agent and active homogenous nucleation techniques. The supercooling was reduced to 3 °C with zinc hydroxyl nitrate as nucleating agent and less than 1 °C with the active homogenous nucleation technique. The LHTESS showed less than 6% degradation in energy storage capacity over 800 cycles.
Compact Diffusion Bonded Heat Exchanger Fatigue Life Simulations (Final Report)
Compact diffusion bonded heat exchangers are essential for high pressure heat exchange, but they are subject to thermal fatigue and ramp rate limitations. Simulation of these geometries is challenging with a large range of length and time scales from thousands of mm-sized microchannels inside a m-sized heat exchanger. Multi-physics simulations including thermal, fluid, and solid mechanics components are being used to predict stress within the heat exchangers under these conditions. These predictions can then be used to understand thermal ramp rate limitations while keeping maximum stresses low as well as fatigue life predictions from well-known empirical models.
Enhanced diffusion bonding of alloy 617 using electric field-assisted sintering
The development of compact heat exchangers (CHXs) has gained increasing interest in many industries owing to their high thermal efficiency and reduced size. Diffusion bonding (DB) is an advantageous technique for fabricating CHXs. Alloy 617 is a candidate for manufacturing CHXs for high-temperature advanced nuclear reactors due to its elevated-temperature properties. Previous endeavors in DB of Alloy 617 were conducted by hot pressing (HP), which reported precipitates at the diffusion-bond interface, limited grain boundary (GB) migration, and significantly reduced high-temperature mechanical properties. To overcome these challenges, this study investigated DB of Alloy 617 using electric field-assisted sintering (EFAS). Stacks composed of three sheets were bonded with EFAS using different temperatures, pressures, and hold times. DB using HP as the zero-current analog of EFAS was also performed for comparison. The result shows that Cr- and Mo-rich precipitates were formed at the interface of the hot-pressed samples. The electric current and temperature in EFAS play a significant role in precipitation and GB migration. The electric current coupled with correct temperatures can effectively prevent precipitate formation at the interface and achieve excellent GB migration. Nanoscale Al-rich oxide was formed at the interface of the samples made by both HP and EFAS, but grain boundaries can ignore the nanoscale Al-oxide and migrate across the interface. The temperature, pressure, and hold time also affected diffusion. The temperature is a prerequisite for a successful GB migration, and GB migration can be enhanced by increasing pressure and hold time.
Thermal-Mechanical Analysis of an Additive Manufacturing Ceramic Heat Exchanger for High-Temperature Recuperator in a sCO2 Power System
Supercritical CO2 (sCO2) Brayton power cycle can be configured in a closed-loop power system and has a potentially high cycle efficiency. Compactness and high efficiency of a sCO2 power block make the sCO2 Brayton cycle a versatile power cycle in broad applications. While many heat sources are of sufficient intensity to produce high temperature working fluids to achieve high cycle efficiency, the thermal-mechanical stability of traditional materials (e.g., steels and nickel-based superalloys) used in construction of heat exchangers and turbine components limits the operating conditions and thus thermodynamic efficiency of the system. This effort seeks to establish the viability of ceramic heat exchanger technologies for the most extreme operating conditions envisioned for power generation and other high temperature processes. Heat exchangers constructed from ultra-high temperature ceramics, a class of extreme environment materials featuring melting points (Tmp.) above 3000 degrees C, is particularly appealing for sCO2 Brayton cycles given their ultra-low creep rates and very high retained strength at low homologous temperatures (i.e., T < 0.5 Tmp., or at least 1500 degrees C). To translate these materials properties to ultra-high temperature heat exchangers, innovations are required in ceramic manufacturing techniques to realize the complex architectures featured in compact heat exchangers with high power density. With appropriate processing, ZrB2-SiC based compositions can be sintered to near full density and shaped into complex topologies via ceramic additive manufacturing methods. This paper analyzes heat exchanger designs and explores thermal-mechanical implications of the operating environment. Thermal flow, heat transfer, and conjugate mechanical analyses provide insights into benefits and risks associated with the design approach.
Hybrid Additive Manufacturing and Electric Field-Assisted Sintering of High-temperature Heat Exchangers via Sacrificial Channel Molds
A hybrid manufacturing approach, integrating additive manufacturing (AM) with powder methodology via electric field-assisted sintering (EFAS), was developed for the fabrication of high-temperature compact heat exchangers (CHX) from refractory metals. The methodology employed additively manufactured sacrificial channel molds (SCMs) as shapeholders for CHX channels, which were embedded in metal powders using EFAS. Following embedding, the SCMs were chemically dissolved to form the internal channel network. SCMs were fabricated using both digital light processing (DLP) and direct ink writing (DIW) from chemically reactive, calcium-based ceramic feedstocks with varying ratios of Al2O3 reinforcement. The microstructure, phase composition, and dissolution behavior of both as-printed and embedded SCMs were investigated. The shrinkage behavior of the SCMs embedded in refractory metals, as well as the interfacial characteristics between the SCMs and metal matrix, were studied. The results showed that the SCMs containing sufficient chemical reactive ceramics dissolved effectively before and after embedding. The as-printed SCMs retained the phase composition of their feedstocks, but the embedded SCMs containing calcium-based ceramics and Al2O3 exhibited the formation of calcium aluminates due to high temperature exposure during embedding. Most SCMs exhibited a cellular Al2O3 network filled with Ca-rich ceramics. Shrinkage after embedding was strongly dependent on SCM density, with lower density SCMs exhibiting greater shrinkage. A thin SCM-affected zone was observed at the metal matrix surface, characterized by increased porosity compared to the bulk matrix. This effect was attributed to infiltration of the SCM materials into powder particle boundaries under pressure, followed by their removal during dissolution. This study demonstrates the feasibility of manufacturing CHXs from hard-to-process refractory metals for use in harsh environments.
Proposed Material Properties, Allowable Stresses, and Design Curves of Diffusion Bonded Alloy 800H for the ASME Code Section III Division 5
Abstract Increased interest in compact heat exchangers (CHXs) to serve as intermediate heat exchangers of very high temperature reactors resulted in significant research and development on their design, analysis, and construction. Printed circuit heat exchangers are a type of CHXs with high thermal efficiency and compactness achieved through diffusion bonding a stack of etched plates with millimeter scaled channels. The diffusion bonding process changes the microstructural and mechanical properties of the wrought metal plates. The current nonnuclear design code ASME section VIII, division 1 captures the material property change through a “joint efficiency factor.” However, the current nuclear design code ASME section III, division 5 does not address or support the diffusion bonded material properties. Hence, there is a need to develop allowable stresses, isochronous curves, and fatigue life curves for various diffusion bonded alloys. In this study, Alloy 800H material was selected to establish the diffusion bonded material properties under tension, creep, fatigue, and creep-fatigue loads at elevated temperatures in the range 550–760 °C. A set of tests on diffusion bonded Alloy 800H (DB 800H) were performed and the acquired data are used in developing allowable stresses Sy, Su, Sr, Sm, St, Smt, So, isochronous curves and fatigue life curves according to the ASME section III, division 5 requirements. This paper also presents detailed procedures used in developing the ASME code section III division 5 design provisions for diffusion bonded Alloy 800H.
Optimization of Triply Periodic Minimal Surface Heat Exchanger to Achieve Compactness, High Efficiency, and Low-Pressure Drop
With advancements in additive manufacturing (AM) techniques, high-quality triply periodic minimal surface (TPMS) structures can now be produced. TPMS walled heat exchangers (HX) hold significant potential for industrial applications and are receiving increasing attention. This paper explores the impact of various TPMS design variables on flow and thermal performance to optimize TPMS heat exchangers for compactness, high efficiency, and low pressure drop. The design variables examined include the type of TPMS lattice, unit cell size, wall thickness, aspect ratio, TPMS orientation, and equivalent thickness. The study reveals that the flow and heat transfer performance of TPMS structures are significantly affected by these design variables. For the Gyroid, Diamond, and SplitP lattices, performance is nearly identical when the surface-to-volume ratio is kept constant. The average velocity of the fluid in the TPMS HX should be 0.3 m/s. The corresponding Re is between 300~800. Thin wall thickness, small equivalent thickness, and flat lattice configurations can significantly reduce pressure drop while maintaining the overall heat transfer coefficient. Additionally, the angle between the flow direction and TPMS orientation can increase pressure drop. Three aluminum heat exchangers were successfully printed using an AM machine, and testing results are comparable with theoretical prediction.
Multi-physics Topology OPtimization and Additive Manufacturing for High-temperature Heat Exchangers
This research significantly advances the understanding of high-temperature heat exchanger design through an integrated approach that combines topology optimization (TO), triply periodic minimal surface (TPMS) structures, additive manufacturing (AM) and thermohydraulic testing. Each of these components contributes uniquely to a unified, high-performance design, fabrication and testing workflow. Topology optimization serves as the foundation of the design methodology by providing a systematic way to determine the most effective material layout for separating hot and cold fluids while maximizing thermal performance. The researchers introduced a novel three-material optimization framework using two density fields to represent hot fluid, cold fluid, and solid domains. This approach enables automated discovery of optimal shapes and flow paths that cannot be intuitively designed, especially under constraints imposed by manufacturing technologies. Furthermore, constraints such as minimal wall thickness and overhang angles were embedded into the optimization process, ensuring that resulting designs are not only thermally efficient but also manufacturable using modern additive techniques. In parallel, the study delves into the use of Gyroid-based TPMS geometries for constructing the core of the heat exchanger. TPMS structures are known for their high surface area, excellent fluid mixing capabilities, and minimal pressure drop characteristics. The researchers applied a data-driven modeling framework using Heteroscedastic Sparse Gaussian Process Regression (HSGPR) combined with genetic algorithms. This allowed for the rapid evaluation and optimization of key geometric parameters such as frequency, iso-value, and phase shift. The result was a set of Gyroid structures tailored for high heat transfer and low flow resistance, demonstrating clear improvements over conventional straight-channel designs. After the designing process, additive manufacturing played a critical role by turning these highly complex, optimized geometries into physical components. Utilizing Laser Powder Bed Fusion (LPBF) with Haynes 282, the study demonstrated the feasibility of fabricating these heat exchangers at high precision. Post-processing methods, including dilation-erosion operations, were applied to ensure local features adhered to self-supporting constraints. The fabricated structures were then subjected to thermohydraulic testing under conditions representative of supercritical CO 2 Brayton cycles, validating the predicted performance and confirming the viability of the full design-to-fabrication pipeline. Finally, thermohydraulic testing across the above studies served as a crucial experimental validation of advanced heat exchanger. Under consistent high-temperature and high-pressure conditions using supercritical CO 2 , the testing demonstrated that both TO and Gyroid-based TPMS designs significantly outperformed conventional straight-channel HXs. The TO design achieved a 115% increase in UA and NTU and a 27.6% boost in gravimetric power density, while the data-driven optimized Gyroid design delivered a 166% increase in UA and NTU and improved effectiveness from 68.7% to 86.1%. These results validate the simulation models, confirm the manufacturability of complex geometries under AM constraints, and provide key insights into design-performance trade-offs, thereby advancing the development of high-efficiency, compact heat exchangers for extreme environments.
Enhanced pool boiling heat transfer with metal foam tubes in inline tube bundle configuration
Flooded evaporators, commonly known as shell-and-tube heat exchangers, are widely used in large-scale industrial refrigeration and air-conditioning systems due to their high pool boiling heat transfer efficiency. However, their bulky configuration requires a large refrigerant inventory, which poses safety challenges—particularly when employing next-generation A2L refrigerants that are mildly flammable. Here, to address this issue, the development of compact heat exchangers with enhanced heat transfer performance is essential. In this study, a novel metal foam tube design is proposed to augment pool boiling heat transfer. Experiments were conducted at a saturation temperature of 20 °C and across a heat flux range of 7–60 kW m −2 . The tests were conducted for both smooth and metal foam tubes with an inline tube bundle configuration and for a pitch–to–diameter (P/D) ratios of 1.3 and 1.5. Pool boiling performance was evaluated for next-generation hydrofluoroolefin (HFO) refrigerants, R1234yf and R1234ze(E), with R134a serving as the baseline fluid. The results indicate that the heat transfer coefficient (HTC) of R1234yf is comparable to R134a, while R1234ze(E) shows slightly lower performance. Importantly, the metal foam tubes achieved up to a 217% enhancement in HTC compared to smooth tubes.