ARM: ARM Aerial Facility (AAF) Condensation Particle Counter via Isokinetic Inlet
ARM Aerial Facility (AAF) Condensation Particle Counter via Isokinetic Inlet
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
ARM Aerial Facility (AAF) Condensation Particle Counter via Isokinetic Inlet
ARM Aerial Facility (AAF) - Unmanned Aircraft Systems, Mixing Condensation Particle Counter
ARM Aerial Facility (AAF) - Unmanned Aircraft Systems, Mixing Condensation Particle Counter, with QC
Capturing the vertical profiles and horizontal variations of atmospheric aerosols often requires accurate airborne measurements. With the advantage of avoiding health and safety concerns related to the use of butanol or other chemicals, water-based condensation particle counters have emerged to provide measurements under various environments. However, airborne deployments are relatively rare due to the lack of instrument characterization under reduced pressure at flight altitudes. This study investigates the performance of a commercial “versatile” water-based condensation particle counter (vWCPC, model 3789, TSI, Shoreview, MN, USA) under various ambient pressure conditions (500–920 hPa) with a wide range of particle total number concentrations (1500–70 000 cm -3 ). The effect of conditioner temperature on vWCPC 3789 performance at low pressure is examined through numerical simulation and laboratory experiments. We show that the default instrument temperature setting of 30 °C for the conditioner is not suitable for airborne measurement and that the optimal conditioner temperature for low-pressure operation is 27°. Under the optimal conditioner temperature (27°), the 7 nm cut-off size is also maintained. Additionally, we show that insufficient droplet growth becomes more significant under the low-pressure operation. The counting efficiency of the vWCPC 3789 can vary up to 20 % for particles of different chemical compositions (e.g., ammonium sulfate and sucrose particles). However, such variation is independent of pressure.
Recent advances in condensation particle counters (CPCs) have improved the detection of sub-3 nm particles, increasing the accuracy of new particle formation (NPF) measurements. However, the detection efficiencies for neutrally charged, atmospherically relevant, sub-1 nm particles, which are critical for the accurate derivation of atmospheric NPF rates, are currently unknown. Here, this study presents a method to measure the detection efficiency of sulfuric acid and clusters of sulfuric acid and dimethylamine using measured CPC concentrations and modeled cluster distributions at atmospherically relevant concentrations. This study finds that water-based CPCs can measure these clusters at detection efficiencies relevant to NPF studies.
The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Model 3772 condensation particle counter (CPC) is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high-concentration measurements, such as basic aerosol research, filter and air cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.
AbstractThis paper describes the modification of a laminar flow, thermally diffusive universal-fluid condensation particle counter (standard operation: 50% detection efficiency at 5 nm) to rapidly measure the size distribution of sub 3 nm aerosol. Sub 3 nm detection was achieved by using diethylene glycol as the working fluid, which enabled high instrument super-saturations while minimizing homogenous nucleation of the working fluid; a detection efficiency of 50% was achieved at 1.6 nm with laboratory-generated ammonium sulfate aerosol. Rapid aerosol sizing beneath 3 nm was achieved by inverting the measured grown droplet size distribution (1 second sampling) to recover the sampled aerosol size distribution. The developed inversion algorithm utilizes analytical kernel functions determined from the instrument response to pseudo-monodisperse ammonium sulfate aerosol from 1.5 nm to 20 nm, generated by a high resolution DMA and a nano DMA. The inversion algorithm was tested numerically with assumed, idealized aerosol size distributions consistent with observed new particle formation events, yielding reasonable agreement between inverted and assumed aerosol size distributions below 3 nm. Furthermore, this technique provides a measure of the aerosol size assuming an aerosol composition identical to that of the aerosol used to generate the experimentally determined kernel function.
The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (aMCPC, 9403), a miniaturized optical practical counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the aMCPC, which measures the ultra-fast total aerosol particle number concentration at 180 ms response rate with a detection diameter (D 50 = 7 nm).
Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Condensational particle counter 3070 (TSI) Calibration: No calibration during the campaign. Files: data_10sec_CPC.csv, data_10min_CPC.csv Header: - NumberConcentration[/cm3]: Number concentration of aerosol particles measured by the CPC, expressed in particles per cubic centimeter. - NumberConcentration[/cm3]_QC: Number concentration of aerosol particles after quality control adjustments or filtering, expressed in particles per cubic centimeter. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement is flagged for quality control checks, (0=pass) - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement
We report a new scanning mobility particle spectrometer (SMPS) for measuring number size distributions of particles down to {approx}1 nm mobility diameter. This SMPS includes an aerosol charger, a TSI 3085 nano differential mobility analyzer (nanoDMA), an ultrafine condensation particle counter (UCPC) using diethylene glycol (DEG) as the working fluid, and a conventional butanol CPC (the 'booster') to detect the small droplets leaving the DEG UCPC. The response of the DEG UCPC to negatively charged sodium chloride particles with mobility diameters ranging from 1-6 nm was measured. The sensitivity of the DEG UCPC to particle composition was also studied by comparing its response to positively charged 1.47 and 1.70 nm tetra-alkyl ammonium ions, sodium chloride, and silver particles. A high resolution differential mobility analyzer was used to generate the test particles. These results show that the response of this UCPC to sub-2 nm particles is sensitive to particle composition. The applicability of the new SMPS for atmospheric measurement was demonstrated during the Nucleation and Cloud Condensation Nuclei (NCCN) field campaign (Atlanta, Georgia, summer 2009). We operated the instrument at saturator and condenser temperatures that allowed the efficient detection of sodium chloride particles but not of air ions having the same mobility. We found that particles as small as 1 nm were detected during nucleation events but not at other times. Factors affecting size distribution measurements, including aerosol charging in the 1-10 nm size range, are discussed. For the charger used in this study, bipolar charging was found to be more effective for sub-2 nm particles than unipolar charging. No ion induced nucleation inside the charger was observed during the NCCN campaign.
Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.
New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth's radiative balance as it produces roughly half of global cloud condensation nuclei. However, the time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub-3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods was tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPSs) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.
When utilizing these data from Kennaook Cape Grim please acknowledge the Australian Bureau of Meteorology and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) for their long-term and continued support of the Kennaook Cape Grim Baseline Air Pollution Monitoring Station. In addition, please contact the Lead Scientists responsible for the collection of these data sets (melita.keywood@csiro.au, ruhi.humphries@csiro.au and Erin.dunne@csiro.au) to discuss collaboration and authorship opportunities.
The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.
Description: data from AOS CPC particle counter, ultrafine (Dp50 > 3 nanometers) resolution
Eastern North Atlantic (ENA) Aerosol Mask (ENA-AM) is a mask developed to isolate high concentration aerosol events and identify the regional baseline in one minute time resolution CPC measurements collected at ENA central site during summer 2017(July 22 to August 20). ENA-AM is based on the statistically different behavior of adjacent data points during background and pollution peaks measurements. Measurements that differ by more than α times the standard deviation (σm) of the data below the median plus the two points after are masked by ENA-AM.
Eastern North Atlantic (ENA) Aerosol Mask (ENA-AM) is a mask developed to isolate high concentration aerosol events and identify the regional baseline in one minute time resolution CPC measurements collected at ENA central site during Winter 2017(December 1-30). ENA-AM is based on the statistically different behavior of adjacent data points during background and pollution peaks measurements. Measurements that differ by more than α times the standard deviation (σm) of the data below the median plus the two points after are masked by ENA-AM.