Search NASA⌕ Search

SEARCH · Search NASA

Results for “Confocal microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Leveraging lifetime information to perform real-time 3D single-particle tracking in noisy environments

A microscopy platform that leverages the arrival time of individual photons to enable 3D single-particle tracking of fast-moving (translational diffusion coefficient of ≃ 3.3 µm 2 /s) particles in high-background environments is reported here. It combines a hardware-based time-gating module, which enables the rate of photon processing to be as high as 100 MHz, with a two-photon excited 3D single-particle tracking confocal microscope to enable high sample penetration depth. Proof-of-principle experiments where single quantum dots are tracked in solutions containing dye-stained cellulose are shown, with tracking performance markedly improved using the hardware-based time-gating module. Furthermore, such a microscope design is anticipated to be of use to a variety of communities who wish to track single-particles in cellular environments, which commonly have high fluorescence and scattering background.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited state lifetime modulation in semiconductor nanocrystals for super-resolution imaging

Abstract We report on proof of principle measurements of a concept for a super-resolution imaging method that is based on excitation field density-dependent lifetime modulation of semiconductor nanocrystals. The prerequisite of the technique is access to semiconductor nanocrystals with emission lifetimes that depend on the excitation intensity. Experimentally, the method requires a confocal microscope with fluorescence-lifetime measurement capability that makes it easily accessible to a broad optical imaging community. We demonstrate with single particle imaging that the method allows one to achieve a spatial resolution of the order of several tens of nanometers at moderate fluorescence excitation intensity.

36 MATERIALS SCIENCE↗

Investigations in the tape-to-tape contact resistance and contact composition in superconducting CORC ® wires

Conductor on Round Core (CORC®) wires and cables, constructed from multiple layers of helically wound REBa 2 Cu 3 O 7–δ tapes, are a promising cable technology for high field magnet applications. An important feature of high-temperature superconductor cables is the ability to share current between conductors, allowing current to bypass drops in I c and minimizing the risk of hot spot formation, which could lead to potential burnout in the superconductor. In contrast to stacked-tape cables, which have continuous contact between tapes, in CORC® the transfer points occur at discrete tape crossovers. The tape-to-tape contact resistance, R c , plays a critical role in the current sharing capabilities and current distribution in cables. For the work reported here, special CORC® wires were manufactured using different winding parameters to investigate variations in R c . Variations comprised inclusion of a lubricant, different lubricant conductivity, inclusion of pre-tinning, and heating briefly to melt the solder. Cables were first tested as straight lengths, followed by bending to a 10 cm diameter. In straight cables R c values ranged from 1 to over 1000 μΩ cm 2 , depending on cabling parameters, with the highest values being found for cables made by the present 'standard' process. Bending the cables to a 10 cm diameter decreased R c by a factor 2–5. Tinning with PbSn decreased R c by three orders of magnitude compared to standard CORC® wires, and heat treating wires with tinned conductor resulted in only a small further decrease in R c . Based on the measured R c at an electric field of 1 μV cm –1 the resulting current transfer length between layers can range from a few millimeters to a tens of centimeters. Examination of contacts with a laser confocal microscope showed plastic deformation of the copper at the edges of the contact overlap area, apparently caused by thicker plating at tape edges digging into the copper of neighboring layers. These images reveal that only a fraction of the total contact surface may actually be touching when there is nothing to compensate for height differential. Images of the PbSn coated tapes indicated that application of solder produces a much more uniform contact surface and higher contact area. Furthermore, imaging of CORC® cross-sections confirmed that in the non-tinned cables there are many regions where tapes are not in contact, while in contrast the PbSn cable shows significantly more contact between the tapes. These different imaging techniques reveal that tape surface morphology is a significant parameter in determining R c .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectral signatures of transverse optical modes in semiconductor nanowires

In order to build nanophotonic devices, it is important to understand and ultimately control the optical mode structure within potential components such as nanoscale waveguides. However, experimental characterization of such modes in the optical regime is difficult due to the nanoscale dimensions of such components and the perturbations that would be induced by a near-field probe. Here, we demonstrate a probe-free, far-field method to characterize the optical modes within GaN nanowires (NWs) based on a novel off-axis scanning confocal microscope system. Using this microscope, we observe spectral signatures resulting from lateral leakage of waveguide modes when they exceed their respective cutoff limits. We identify these modes within hyperspectral images using an analytical model coupled with finite element simulations. The model can also be used to predict the spectral signatures for given geometrical and dielectric parameters, which enabled us to deduce the transverse dimension of the NW from hyperspectral images with an accuracy of ∼ <#comment/> 30 nm .

Wang, Maoji↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

Status of the Characterization of DEs from the Full Circumference Examination of the Inner Container Closure Weld Region (FY2020)

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR a laser confocal microscope (LCM) is used to perform close visual examination of the surface and measurements of corrosion features on the surface. DE containers from FY13 through FY16 were screened with three candidates selected for full circumference evaluation (FCE) according to the ICCWR examination protocol, During the FCE, FY16 DE05 and FY15 DE07 showed suspect major corrosion events, FY16 DE05 Section C2 shows two crack-like features, identified as Denebola and Draco. Both features are located at the boundary of Zone 2 and Zone 3. Consequently, Section C2 of FY16 DE05 was selected for examination by serial metallography at Savannah River National Laboratory (SRNL). For FY15 DE07 the suspect corrosion events were observed on Sections Cl and C2. Section Cl shows one crack-like feature, identified as Acrux. Section C2 shows three crack-like features, identified as Bellatrix, Cursa Minor and Cursa Major. Unlike Acrux and Bellatrix, which are located at the boundary of Zone 2 and Zone 3, Cursa Minor and Cursa Major are located in Zone 2. Sections Cl and C2 of FY15 DE07 were sent to Los Alamos National Laboratory (LANE) for characterization by X-Ray Tomography (XRT).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wide Area 3D Measurement System for Analysis of 3013 Inner Container Closure Weld Region

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR, a laser confocal microscope (LCM) is used to perform close visual examination of the surface and to measure corrosion features on the surface. However, in FY20, the introduction of the Wide Area 3D Measurement System (WAMS) was tested as a method for faster inspection of the ICCWR. Optimization of the WAMS parameters for data collection was carried out using a generic tear-drop type sample containing large and fine Stress Corrosion Cracking (SCC) fractures and high resolution images were compared to the image obtained with the LCM. Although the image with the LCM shows higher resolution than the WAMS images, the small features can be still identified in the WAMS images. The advantage of collecting data for the full circumference using the WAMS is that it can take about a week to complete, which represents 1/16 of the time needed with the LCM. Nonetheless, both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS can be utilized to obtain images for faster screening or identification of corrosion features on the surface while the LCM can be utilized to obtain higher resolution images of those areas identified by the WAMS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking (FY2020 Progress Report)

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g. height, color and grayscale values; all as functions of a location in a plane projection). It is the objective of this project to produce a user-friendly interface that incorporated all operations needed to perform surface examination. For this reason, a Matlab-based Graphical User Interface (GUI) was created to integrate data input with software developed for processing and evaluation. In summary, the GUI permits selective downloading of binary data, interrogation of attributes, data labeling, flagging of significant features, execution of Machine Learning (ML) algorithms, output of parameters for trained ML algorithms, reports of ML model accuracy with respect to labeled data, and generation of graphical representations of various analyses.

3013 corrosion↗

FY21 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g., height, color and grayscale values; all as functions of a location in a plane projection). A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data, flag significant features, execute Machine Learning (ML) algorithms, output parameters for trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Features can be called out by user-specified thresholds, manual labeling or machine learning algorithms when they have been completed. The ability to rapidly label data is important because of the volume of data required for training machine learning algorithms. The GUI has the flexibility to allow addition of improved ML algorithms, methods for data visualization, and statistical computations. Statistical analyses via the GUI include areas of pits within a defined range of pit depths, correlations between Red-Green-Blue (RGB) or grayscale intensity and relative surface height, covariances between values associated with features, and feature histograms. The development of supervised machine learning algorithms, however, has been hindered by a lack of training data. The machine learning algorithms for crack identification are being refined but require improvements to the true positive rate for crack detection. This shortcoming is an artifact of the limited training data currently available, perhaps more so than the structure of the neural networks. At present, the best results are had from a consensus over an ensemble of randomly generated Deep Neural Network (DNN) or Convolutional Neural Network (CNN) algorithms. Although the consensus accuracy method has yielded optimum true positive and true negative rates in excess of 80%, additional validation testing is necessary. In addition to the suite of LCM data that was initially used, and which represents the majority of the work presented in this report, WAMS image data was also reviewed at a preliminary level. The review included a comparison between image resolution and dynamic range for each method. WAMS (ZON file) image data was found to have a pixel pitch of 3.69μm compared to 1 μm for the LCM (vk4 file) data, which implies a lower resolution for the WAMS images. Conversely, the ratio of dynamic range of the WAMS data to the LCM data was approximately 41:20 for height data, suggesting that information from WAMS should more accurately determine the depth of pits. At present, the significance of the greater dynamic range of the WAMS data relative to the LCM data has not yet been evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pit depth analysis using automated software for three containers with complete imaging

The 3013 surveillance program is tasked with ensuring the long term safety of plutonium storage in 3013-compliant containers. One component of this task is to understand corrosion features found on the interior sidewall of the inner container closure weld region (ICCWR). To this end, three containers were selected to have laser confocal microscope (LCM) 20X imaging of the entire ICCWR. This report describes the analysis of the LCM pit depth data using the automated corrosion analysis software. The analysis included determining maximum pit depths and distributions of pit depths, volumes, and diameters for all pit features identified on the three containers. Results provided insight into possible corrosion mechanisms and were consistent with previous pit growth model predictions.

36 MATERIALS SCIENCE↗

3013 Inner Container Closure Weld Region (ICCWR) Characterization by Wide Area 3D Measurement System (WAMS) Analysis (FY21 Progress Report)

As part of the 3013 Surveillance Program, through-wall penetration from stress corrosion cracking (SCC) of the 3013 inner containers has been identified as the most credible condition for failure withing the 50- years lifetime. Chlorides contained in Pu-bearing material, together with intra-canister humidity levels, metallurgical conditions, and internal stresses have been found to produce corrosion in the Inner Container Closure Weld Region (ICCWR) of the 3013 canister system. A Laser Confocal Microscope (LCM) is used as part of the 3013 Surveillance Program protocol to identify the prevalence of corrosion and corrosionrelated cracking in the ICCWR2. With the LCM, a close visual examination is made of the ICCWR surface along with measurements of corrosion-related features. LCM inspections produce immense amounts of image data that is time intensive to analyze. There is also a 9-year backlog of images, with approximately 49 canisters that must be evaluated. To expedite data analysis and reduce the amount of generated data, a Wide Area 3D Measurement System (WAMS) microscope has been added to the examination protocol. Although WAMS is a lower resolution microscope, small features of interest can be still identified. The advantage of collecting data for the full circumference using the WAMS is that it can take about 1/16 of the time needed with the LCM. Both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS is an efficient system for screening and identification of corrosion features while the LCM can be utilized to obtain higher resolution images areas identified by the WAMS. This report explains and justifies the data collection methods used with the WAMS. It includes a summary of the data generated by WAMS in FY21. The goals set for data collection in FY21 were met. A total of twenty-two DE’s were imaged, and analysis was carried out on eleven samples. The analyzed samples showed large numbers of potential cracks and pits distributed throughout the surfaces. Lastly, to explain the advantages of the WAMS, its capabilities were compared to those of a simpler microscope. Micrographs of the samples imaged in FY21 and those analyzed are included in the appendices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY22 Progress Report: SRNL Analysis of ICCWR LCM and WAMS Data for Corrosion and Cracking

Algorithms for machine learning and data analysis for the 3013 Surveillance Program are being developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). To detect the presence of corrosion and cracking, data is collected from large binary files generated by a Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS). Software is being developed to use the physical attributes in the data files (e.g., height, color, and grayscale values; all as functions of a location in a plane projection) to detect the presence of surface corrosion and cracking. A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data for training ML algorithms, flag significant features, execute Machine Learning (ML) algorithms, output parameters from trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Surface defects can be called out by setting user-specified thresholds, feature based analysis or machine learning algorithms. Enhancements to data labeling capability have been developed to address this essential precursor to application of ML routines. Efficient labeling is particularly important in view of the very large volume of data required to train ML algorithms.

3013 Corrosion↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

FY23 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), and in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or all of: height, color, and grayscale values as functions of position in a plane projection) to detect the presence of surface corrosion and cracking after being trained on similar data with the features to be detected labeled.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY24 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), or,in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or more of: height, color, and 16-bit grayscale values as functions of position in a plane projection) to detect signs of surface corrosion and cracking after being trained on similar data, with the features to be detected. Although the initial scope included screening for broader indicators of corrosion, e.g., pitting, identification of potential cracks was prioritized for the past several years at the request of program leadership. Labeled training data is essential to developing the ML algorithm, and enhancements to data labeling capability have been developed to address this essential precursor to application of ML routines. Efficient labeling is particularly important in view of the large volume of data required to train ML algorithms and the relative rarity of cracks in the ICCWR data set. The updated program will read binary data from either LCM, WAMS or SEM files, interrogate data attributes, facilitate user labeling of data for training ML algorithms, execute ML algorithms, output parameters from trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. In FY24, hourglass neural networks (HNNs) that were initiated in FY22 were further developed and tested using available LCM data, and their performance was tested against that of the alternative U-Net Neural Network algorithm structure. HNNs along with previously developed Convolutional Neural Networks (CNNs) and Deep Neural Networks (DNNs) comprise a suite of ML tools for identification of cracks in the ICCWR

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY25 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and image analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and cracks in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), or, in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or more of: height, color, and 16-bit grayscale values as functions of position in a plane projection) to detect signs of surface corrosion and cracking after being trained on similar data with the features to be detected. Although the initial scope included screening for broader indicators of corrosion, e.g., pitting, the identification of potential cracks was prioritized for the past several years at the request of program leadership.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE↗

Magnetophoretic Induction of Root Curvature

The last year of the grant period concerned the consolidation of previous experiments to ascertain that the theoretical premise apply not just to root but also to shoots. In addition, we verified that high gradient magnetic fields do not interfere with regular cellular activities. Previous results have established that: (1) intracellular magnetophoresis is possible; and (2) HGMF lead to root curvature. In order to investigate whether HGMF affect the assembly and/or organization of structural proteins, we examined the arrangement of microtubules in roots exposed to HGMF. The cytoskeletal investigations were performed with fomaldehyde-fixed, nonembedded tissue segments that were cut with a vibratome. Microtubules (MTs) were stained with rat anti-yeast tubulin (YOL 1/34) and DTAF-labeled antibody against rat IgG. Microfilaments (MFs) were visualized by incubation in rhodamine-labeled phalloidin. The distribution and arrangement of both components of the cytoskeleton were examined with a confocal microscope. Measurements of growth rates and graviresponse were done using a video-digitizer. Since HGMF repel diamagnetic substances including starch-filled amyloplasts and most The second aspect of the work includes studies of the effect of cytoskeletal inhibitors on MTs and MFs. The analysis of the effect of micotubular inhibitors on the auxin transport in roots showed that there is very little effect of MT-depolymerizing or stabilizing drugs on auxin transport. This is in line with observations that application of such drugs is not immediately affecting the graviresponsiveness of roots.

Hasenstein, Karl H.↗