SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking (FY2020 Progress Report)

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g. height, color and grayscale values; all as functions of a location in a plane projection). It is the objective of this project to produce a user-friendly interface that incorporated all operations needed to perform surface examination. For this reason, a Matlab-based Graphical User Interface (GUI) was created to integrate data input with software developed for processing and evaluation. In summary, the GUI permits selective downloading of binary data, interrogation of attributes, data labeling, flagging of significant features, execution of Machine Learning (ML) algorithms, output of parameters for trained ML algorithms, reports of ML model accuracy with respect to labeled data, and generation of graphical representations of various analyses.

3013 corrosion↗

FY21 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g., height, color and grayscale values; all as functions of a location in a plane projection). A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data, flag significant features, execute Machine Learning (ML) algorithms, output parameters for trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Features can be called out by user-specified thresholds, manual labeling or machine learning algorithms when they have been completed. The ability to rapidly label data is important because of the volume of data required for training machine learning algorithms. The GUI has the flexibility to allow addition of improved ML algorithms, methods for data visualization, and statistical computations. Statistical analyses via the GUI include areas of pits within a defined range of pit depths, correlations between Red-Green-Blue (RGB) or grayscale intensity and relative surface height, covariances between values associated with features, and feature histograms. The development of supervised machine learning algorithms, however, has been hindered by a lack of training data. The machine learning algorithms for crack identification are being refined but require improvements to the true positive rate for crack detection. This shortcoming is an artifact of the limited training data currently available, perhaps more so than the structure of the neural networks. At present, the best results are had from a consensus over an ensemble of randomly generated Deep Neural Network (DNN) or Convolutional Neural Network (CNN) algorithms. Although the consensus accuracy method has yielded optimum true positive and true negative rates in excess of 80%, additional validation testing is necessary. In addition to the suite of LCM data that was initially used, and which represents the majority of the work presented in this report, WAMS image data was also reviewed at a preliminary level. The review included a comparison between image resolution and dynamic range for each method. WAMS (ZON file) image data was found to have a pixel pitch of 3.69μm compared to 1 μm for the LCM (vk4 file) data, which implies a lower resolution for the WAMS images. Conversely, the ratio of dynamic range of the WAMS data to the LCM data was approximately 41:20 for height data, suggesting that information from WAMS should more accurately determine the depth of pits. At present, the significance of the greater dynamic range of the WAMS data relative to the LCM data has not yet been evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pit depth analysis using automated software for three containers with complete imaging

The 3013 surveillance program is tasked with ensuring the long term safety of plutonium storage in 3013-compliant containers. One component of this task is to understand corrosion features found on the interior sidewall of the inner container closure weld region (ICCWR). To this end, three containers were selected to have laser confocal microscope (LCM) 20X imaging of the entire ICCWR. This report describes the analysis of the LCM pit depth data using the automated corrosion analysis software. The analysis included determining maximum pit depths and distributions of pit depths, volumes, and diameters for all pit features identified on the three containers. Results provided insight into possible corrosion mechanisms and were consistent with previous pit growth model predictions.

36 MATERIALS SCIENCE↗

3013 Inner Container Closure Weld Region (ICCWR) Characterization by Wide Area 3D Measurement System (WAMS) Analysis (FY21 Progress Report)

As part of the 3013 Surveillance Program, through-wall penetration from stress corrosion cracking (SCC) of the 3013 inner containers has been identified as the most credible condition for failure withing the 50- years lifetime. Chlorides contained in Pu-bearing material, together with intra-canister humidity levels, metallurgical conditions, and internal stresses have been found to produce corrosion in the Inner Container Closure Weld Region (ICCWR) of the 3013 canister system. A Laser Confocal Microscope (LCM) is used as part of the 3013 Surveillance Program protocol to identify the prevalence of corrosion and corrosionrelated cracking in the ICCWR2. With the LCM, a close visual examination is made of the ICCWR surface along with measurements of corrosion-related features. LCM inspections produce immense amounts of image data that is time intensive to analyze. There is also a 9-year backlog of images, with approximately 49 canisters that must be evaluated. To expedite data analysis and reduce the amount of generated data, a Wide Area 3D Measurement System (WAMS) microscope has been added to the examination protocol. Although WAMS is a lower resolution microscope, small features of interest can be still identified. The advantage of collecting data for the full circumference using the WAMS is that it can take about 1/16 of the time needed with the LCM. Both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS is an efficient system for screening and identification of corrosion features while the LCM can be utilized to obtain higher resolution images areas identified by the WAMS. This report explains and justifies the data collection methods used with the WAMS. It includes a summary of the data generated by WAMS in FY21. The goals set for data collection in FY21 were met. A total of twenty-two DE’s were imaged, and analysis was carried out on eleven samples. The analyzed samples showed large numbers of potential cracks and pits distributed throughout the surfaces. Lastly, to explain the advantages of the WAMS, its capabilities were compared to those of a simpler microscope. Micrographs of the samples imaged in FY21 and those analyzed are included in the appendices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY22 Progress Report: SRNL Analysis of ICCWR LCM and WAMS Data for Corrosion and Cracking

Algorithms for machine learning and data analysis for the 3013 Surveillance Program are being developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). To detect the presence of corrosion and cracking, data is collected from large binary files generated by a Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS). Software is being developed to use the physical attributes in the data files (e.g., height, color, and grayscale values; all as functions of a location in a plane projection) to detect the presence of surface corrosion and cracking. A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data for training ML algorithms, flag significant features, execute Machine Learning (ML) algorithms, output parameters from trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Surface defects can be called out by setting user-specified thresholds, feature based analysis or machine learning algorithms. Enhancements to data labeling capability have been developed to address this essential precursor to application of ML routines. Efficient labeling is particularly important in view of the very large volume of data required to train ML algorithms.

3013 Corrosion↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

FY23 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), and in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or all of: height, color, and grayscale values as functions of position in a plane projection) to detect the presence of surface corrosion and cracking after being trained on similar data with the features to be detected labeled.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY24 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), or,in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or more of: height, color, and 16-bit grayscale values as functions of position in a plane projection) to detect signs of surface corrosion and cracking after being trained on similar data, with the features to be detected. Although the initial scope included screening for broader indicators of corrosion, e.g., pitting, identification of potential cracks was prioritized for the past several years at the request of program leadership. Labeled training data is essential to developing the ML algorithm, and enhancements to data labeling capability have been developed to address this essential precursor to application of ML routines. Efficient labeling is particularly important in view of the large volume of data required to train ML algorithms and the relative rarity of cracks in the ICCWR data set. The updated program will read binary data from either LCM, WAMS or SEM files, interrogate data attributes, facilitate user labeling of data for training ML algorithms, execute ML algorithms, output parameters from trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. In FY24, hourglass neural networks (HNNs) that were initiated in FY22 were further developed and tested using available LCM data, and their performance was tested against that of the alternative U-Net Neural Network algorithm structure. HNNs along with previously developed Convolutional Neural Networks (CNNs) and Deep Neural Networks (DNNs) comprise a suite of ML tools for identification of cracks in the ICCWR

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY25 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and image analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and cracks in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), or, in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or more of: height, color, and 16-bit grayscale values as functions of position in a plane projection) to detect signs of surface corrosion and cracking after being trained on similar data with the features to be detected. Although the initial scope included screening for broader indicators of corrosion, e.g., pitting, the identification of potential cracks was prioritized for the past several years at the request of program leadership.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE↗

High Cooperativity Using a Confocal-Cavity–QED Microscope

Cavity quantum electrodynamics (QED) with cooperativity far greater than unity enables high-fidelity quantum sensing and information processing. The high-cooperativity regime is often reached through the use of short single-mode resonators. More complicated multimode resonators, such as the near-confocal optical Fabry-Pérot cavity, can provide intracavity atomic imaging in addition to high cooperativity. This capability has recently proved important for exploring quantum many-body physics in the driven-dissipative setting. In this work, we show that a confocal-cavity–QED microscope can realize cooperativity in excess of 110. This cooperativity is on par with the very best single-mode cavities (which are far shorter) and 21 times greater than single-mode resonators of similar length and mirror radii. The 1.7-µm imaging resolution is naturally identical to the photon-mediated interaction range. We measure these quantities by determining the threshold of cavity superradiance when small optically tweezed BoseEinstein condensates are pumped at various intracavity locations. Transmission measurements of an ex situ cavity corroborate these results. We provide a theoretical description that shows how cooperativity enhancement arises from the dispersive coupling to the atoms of many near-degenerate modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiscale characterization and representation of variability in ceramic matrix composites

Low density, high strength, and high creep and oxidation resistance properties of ceramic matrix composites (CMCs) make them an ideal choice for use in extreme environments in space and military applications. This paper presents a detailed characterization study of structural and manufacturing flaws in Carbon fiber Silicon-Carbide-Nitride matrix (C/SiNC) CMCs at different length-scales. Energy-dispersive spectroscopy (EDS) is used for the chemical characterization of the material’s elemental constituents. High-resolution multiscale graphs obtained from scanning electron microscope (SEM) and confocal laser scanning microscope (LSM) are used to characterize the distribution and morphology of defects at different length scales. This is followed by the classification and quantification of the common manufacturing defects. An image processing algorithm based on the image segmentation process is developed to quantify the variability of various scale-dependent architectural parameters. Finally, a three-dimensional stochastic representative volume element (SRVE) generation algorithm is developed to provide precise representations of material textures at multiple length scales. The developed algorithm accurately accounts for material features and flaws based on a range of multiscale structural and defects characterization results.

36 MATERIALS SCIENCE↗

Free-space confocal magneto-optical spectroscopies at milliKelvin temperatures

We describe the operation of a free-space confocal optical microscope operated in a dilution refrigerator. The microscope is installed on a cold insertable probe to enable fast sample exchange while the refrigerator is held at low temperatures. A vector magnet provides a 6 T field normal to the sample and 1 T fields at arbitrary angles. A variety of optical microscopies and spectroscopies, including photoluminescence, Raman, magneto-optical Kerr effect, and spin relaxometry measurements are described, and some of the challenges associated with performing these measurements at milliKelvin temperatures are explored.

Lawrie, B. J.↗

Free-space confocal magneto-optical spectroscopies at milliKelvin temperatures

We describe the operation of a free-space confocal optical microscope operated in a dilution refrigerator. The microscope is installed on a cold insertable probe to enable fast sample exchange while the refrigerator is held at low temperatures. A vector magnet provides a 6 T field normal to the sample and 1 T fields at arbitrary angles. A variety of optical microscopies and spectroscopies, including photoluminescence, Raman, magneto-optical Kerr effect, and spin relaxometry measurements are described, and some of the challenges associated with performing these measurements at milliKelvin temperatures are explored.

Lawrie, Benjamin↗

Biofouling of filtration membranes in wastewater reuse: In situ visualization with confocal laser scanning microscopy

The filtration membranes utilized in advanced treatment of municipal wastewater are prone to biological fouling. Permeability loss and water recovery limitations due to fouling necessitate additional pretreatment and membrane cleaning, which raise the cost of water reuse. Better fouling mitigation calls for a deeper understanding of biofilm behavior on water reuse membranes. This study uses confocal microscopy to monitor biofouling under realistic conditions. To simulate water reuse, a miniature flow cell with microfiltration and ultrafiltration membranes was operated under typical filtration conditions using secondary effluent from California's East Bay Municipal Utility District. The growing biofilms were stained for extracellular polymeric substances and live and dead cells, and they were monitored in situ under filtration conditions with a confocal laser scanning microscope to produce 2-D and 3-D images. In situ image series revealed biofilm growth and removal processes including internal and external fouling, extracellular polymeric substance production, wrinkling, delamination, and film re-deposition. Additionally, changes in biofilm morphology between in situ and ex situ images highlighted limitations of ex situ imaging. Here, these results provide insight into the physical and biological mechanisms of biofouling in hopes of informing the development of improved techniques for biofouling mitigation.

ultrafiltration↗

Utilization of Ultrasonication as a Method of Reducing Organic and Inorganic Contamination in Post‐Consumer Plastic Film Waste

Post-consumer plastic film waste often carries organic and inorganic contaminants that challenge recycling processes and affect the quality of recycled products. An effective contaminant removal procedure through washing such single-used plastic films (SUPFs) can address environmental and waste management concerns. This study compares the efficiency of different washing techniques in reducing SUPF contamination. To evaluate the efficacy of each washing technique, film samples collected from material recovery facilities are individually exposed to friction, ultrasonic-assisted, and a combination of both washes. Thermal analysis indicates that the polymers' melting temperature, crystallization temperature, and crystallinity remain unaffected by the washing methods, demonstrating method aptness. Confocal laser scanning microscope images show that washing results in a cleaner sample surface. 91% ash reduction during the combined wash treatment indicates a high method efficiency compared to the individual friction and ultrasonic wash procedures. This is further validated by reducing characteristic contaminant IR bands (3600–3000, 1750–1600, and 1100–1000 cm −1 ). Elements of concern such as Cd, Cr, Hg, and Pb in SUPFs after each washing technique applied conform with regulations (<100 ppm) for packaging products. This research shows the novel ultrasonic washing reduces more contamination than friction with shorter wash times and no surfactants.

42 ENGINEERING↗

Iron Oxide Reduction Rate Affects Iron Product Morphology

Magnetite concentrates from different parts of the Mesabi Range, exhibiting varying tendencies to encapsulate, were reduced using thermogravimetric analysis (TGA) and a high-temperature confocal scanning laser microscope (CSLM). Gas-phase mass-transfer conditions were intentionally varied by employing two reactors with different geometries: the TGA produced significantly slower reduction, whereas the CSLM setup yielded reduction rates up to 20 times faster under mass-transfer-controlled conditions. A preliminary mechanism is proposed to explain the transition from a porous iron product to a dense encapsulating layer. Encapsulation is interpreted as the outcome of competition between pore creation, driven by the reduction rate, and pore elimination, driven by surface diffusion. When pore formation is insufficient to counteract pore coarsening, a dense iron layer develops and restricts further reduction.

encapsulation↗

High-Precision Mapping of Diamond Crystal Strain Using Quantum Interferometry

Crystal-strain variation imposes significant limitations on many quantum sensing and information applications for solid-state defect qubits in diamond. Thus, the precision measurement and control of diamond crystal strain is a key challenge. Here, we report diamond strain measurements with a unique set of capabilities, including micron-scale spatial resolution, a millimeter-scale field of view, and a 2-order-of-magnitude improvement in volume-normalized sensitivity over previous work, reaching 5(2)×10 -8 /√Hzμm -3 (with spin-strain coupling coefficients representing the dominant systematic uncertainty). We use strain-sensitive spin-state interferometry on ensembles of nitrogen-vacancy (N-V) color centers in single-crystal bulk diamond with low strain gradients. This quantum interferometry technique provides insensitivity to magnetic-field inhomogeneity from the electronic and nuclear spin bath, thereby enabling long N-V–ensemble electronic spin dephasing times and enhanced strain sensitivity, as well as broadening the potential applications of the technique beyond isotopically enriched or high-purity diamond. We demonstrate the strain-sensitive measurement protocol first on a confocal scanning laser microscope, providing quantitative measurement of sensitivity as well as three-dimensional strain mapping; and second on a wide-field-imaging quantum diamond microscope. Our strain-microscopy technique enables fast, sensitive characterization for diamond material engineering and nanofabrication; as well as diamond-based sensing of strains applied externally, as in diamond anvil cells or embedded diamond stress sensors, or internally, as by crystal damage due to particle-induced nuclear recoils.