Search NASA⌕ Search

SEARCH · Search NASA

Results for “Continuous manufacturing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Switching from batch to continuous granulation: A case study of metoprolol succinate ER tablets

Continuous manufacturing (CM) has been used to produce several immediate release drug products. No extended-release (ER) product manufactured employing CM technology has been approved yet. Herein this study investigated the critical aspects of switching from the batch mode of high shear granulation to the continuous operation of twin-screw granulation for extended-release tablets. Metoprolol succinate ER tablets was used as a model ER formulation for this purpose. A central composite design (CCD) was employed to determine the effects of high shear granulator (HSG) parameters, namely impeller speed, granulation time, and binder liquid feeding rate, on the critical granulation characteristics important for product performance. These critical granulation characteristics served as a guide for switching from the batch processing to the continuous operation for achieving the same breaking strength and dissolution for this ER metoprolol tablets. The granulation time was the most critical factor affecting the bulk properties of granules which contributed to tablet dissolution. The higher density and lower compressibility of granules were attained at the longest granulation time of 5.4 min with the fastest liquid feeding rate of 75 g/min. The granules’ density was the primary factor negatively affecting the dissolution of metoprolol tablets. However, the breaking strength of tablets confounded the effect of granules density on metoprolol dissolution. Switching the processing parameters of high shear granulation to twin-screw granulation achieved similar dissolution profiles (F2 greater than 50). The screw speed was not found to affect bulk properties of granules. The root cause of granulation failures in twin-screw granulation, such as premature consolidation, excessive swelling, poor cohesion, inconsistent shearing effects, and formation of deformed agglomerates, were identified. In conclusion, the use of critical granulation characteristics through a performance-based approach of ER tablets facilitated the switching of manufacturing of an ER formulation form batch to continuous operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a continuous synthesis process for carbamazepine using validated in-line Raman spectroscopy and kinetic modelling for disturbance simulation

Mitigation of failure modes in the continuous synthesis (CS) of a drug substance (DS) has the potential to widen the adoption of continuous manufacturing (CM) technologies by the pharmaceutical industry. Here, this work demonstrates the development of a robust continuous process for the synthesis of carbamazepine (CBZ), an essential medicine as per the World Health Organization (WHO), facilitated by kinetic modelling and monitored by in-line Raman spectroscopy. Accurate kinetic modelling and the use of validated process analytical technology (PAT) models for quantitative measurement were found to play an important role in developing CS of drug substances. Kinetic data for the formation of CBZ from iminostilbene (ISB) were collected by batch reaction sampling and high-performance liquid chromatography (HPLC) analysis. A non-linear solver and iterative method was applied to determine two sets of Arrhenius parameters simultaneously for the reaction system by minimizing the standard error of the model fit. The start-up and dynamic equilibrium stages for the CS of CBZ using a continuous stirred tank reactor (CSTR) were modelled based on the batch kinetic data and employed to optimize conversion and simulate process disturbances. An in-line Raman spectroscopy method was successfully developed, validated, and integrated to determine the concentrations of CBZ and ISB within the operating range for the CS. The CS kinetic model was evaluated experimentally from startup to dynamic equilibrium over 10 residence times with monitoring by HPLC and in-line Raman spectroscopy. The developed kinetic model in tandem with in-line Raman spectroscopy successfully predicted disturbances due to changes in process variables and can serve as a useful tool in the future design of advanced process control strategies for the continuous synthesis of CBZ.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recyclability of additively manufactured bio-based composites

As the flexibility, efficiency, and application space of additive manufacturing continues to grow, many have begun to investigate more sustainable feedstocks as well as options for the end of life of additively manufactured parts. This study examines the effects of mechanical recycling on additively manufactured parts from bio-based feedstock. Here, articles were printed on the Big Area Additive Manufacturing (BAAM) system at the Oak Ridge National Laboratory using poly (lactic acid)/wood flour (PLA/WF) pellets. These parts were shredded and granulated, and the granulate was fed directly back into the BAAM system for re-printing, skipping the costly and energy-intensive steps of extrusion and pelletization. The chemical, mechanical, thermal, and rheological changes to PLA/WF before and after recycling were investigated. Additionally, the energy savings from directly printing granulate on the BAAM system without extrusion and pelletization is reported. It is shown that PLA/WF is an excellent candidate for recycling of large format additively manufactured parts, and value of these parts can be reclaimed while saving cost and energy through mechanical recycling.

42 ENGINEERING↗

Aerogel with Unparalleled Performance and Cost-Effectiveness for All Insulation Needs (CRADA Final Report)

Westwood Aerogel investigated the reproducible production of an ambiently or electromagnetic spectrum assisted drying of extremely porous aerogel materials. Traditional aerogel processing is limited by low throughput and scalability due to supercritical drying. Westwood Aerogel’s advanced manufacturing process enables commercialization and deployment at scale, making aerogel materials more accessible to a range of industries and applications. We focused on shifting from the lab scale environment to manufacturing prototypes. The initial manufacturing model is based on the float glass process, which is the industry standard for glass window production, and the paper drying process. By incorporating an ambient drying process a continuous line model can be used from start to finish. The project team worked to develop a continuous manufacturing system to scale-up and reduce costs while maintaining the lightweight and insulative properties of aerospace-grade aerogel. While aerogels are extremely insulative, lightweight, and thin materials (making them ideal insulators across application spaces), high costs and stagnant innovation have hampered their wider adoption. Traditional manufacturing of aerogel requires supercritical extraction of pore fluid to obtain highly insulating materials, which is an energy intensive batch process and limits aerogel production output. Westwood Aerogel’s proprietary ambient drying process enables the continuous production of highly insulative aerogel materials without the use of supercritical extraction.

36 MATERIALS SCIENCE↗

Kinetic modelling of an environmentally friendly carbamazepine synthesis via urea and iminostilbene in batch and continuous processes

Accurate kinetic models for reaction systems allow for improved process understanding and greater quality control, which is particularly beneficial as the pharmaceutical industry shifts from batch to continuous manufacturing (CM). In this work, a first principles kinetic model has been developed for the synthesis of carbamazepine (CBZ) from iminostilbene and urea, starting in a batch reactor and subsequently in a continuous flow reactor. An eco-friendly reaction pathway using urea was selected to avoid the toxic reagents that are typically used for synthesis of CBZ. The kinetic parameters determined from batch reactions were utilized in a MATLAB based kinetic model to simulate the yield for the continuous process. Overall, good agreement between the model prediction and corresponding experimental values was observed for the batch and continuous reaction systems within the full factorial design space. However, the model slightly overpredicted the yield of the continuous reaction system for higher conversion values (>60%) since it did not account for the reverse reaction that can occur at the studied reaction conditions. Here, the use of broken order kinetics was compared with whole number orders, and it was determined that the whole number orders resulted in better agreement at all conversion values for the continuous system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of key energy and performance metrics for drug product manufacturing

During the development of pharmaceutical manufacturing processes, detailed systems-based analysis and optimization are required to control and regulate critical quality attributes within specific ranges, to maintain product performance. As discussions on carbon footprint, sustainability, and energy efficiency are gaining prominence, the development and utilization of these concepts in pharmaceutical manufacturing are seldom reported, which limits the potential of pharmaceutical industry in maximizing key energy and performance metrics. Based on an integrated modeling and techno-economic analysis framework previously developed by the authors, this study presents the development of a combined sensitivity analysis and optimization approach to minimize energy consumption while maintaining product quality and meeting operational constraints in a pharmaceutical process. The optimal input process conditions identified were validated against experiments and good agreement resulted between simulated and experimental data. Here, the results also allowed for a comparison of the capital and operational costs for batch and continuous manufacturing schemes under nominal and optimized conditions. Using the nominal batch operations as a basis, the optimized batch operation results in a 71.7% reduction of energy consumption, whereas the optimized continuous case results in an energy saving of 83.3%.

59 BASIC BIOLOGICAL SCIENCES↗

An overview of various critical aspects of low-cobalt/cobalt-free Li-ion battery cathodes

Cathodes of lithium-ion batteries (LIBs) significantly impact the environmental footprint, cost, and energy performance of the battery-pack. Hence, sustainable production of Li-ion battery cathodes is critically required for ensuring cost-effectiveness, environmental benignity, consumer friendliness, and social justice. Battery chemistry largely determines individual cell performance as well as the battery pack cost and life cycle greenhouse gas emission. Continuous manufacturing platforms improve production efficiency in terms of product yield, quality and cost. Spent-battery recycling ensures the circular economy of critical elements that are required for cathode production. Innovations in fast-charging LIBs are particularly promising for sustainable e-mobility with a reduced carbon footprint. This article provides an overview of these research directions, emphasizing strategies for low-cobalt cathode development, recycling processes, continuous production and improvement in fast-charging capability.

25 ENERGY STORAGE↗

Scalable fabrication of an array-type fixed-target device for automated room temperature X-ray protein crystallography

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals. To address this need, we have developed a device that facilitates the straightforward mounting of protein crystals for diffraction analysis, and that can be easily manufactured at scale. Inspired by grid-style devices that have been reported in the literature, we have developed an X-ray compatible microfluidic device that can be used to trap protein crystals in an array configuration, while also providing excellent optical transparency, a low X-ray background, and compatibility with the robotic sample handling and environmental controls used at synchrotron macromolecular crystallography beamlines. At the Stanford Synchrotron Radiation Lightsource (SSRL), these capabilities allow for fully remote-access data collection at controlled humidity conditions. Furthermore, we have demonstrated continuous manufacturing of these devices via roll-to-roll fabrication to enable cost-effective and efficient large-scale production.

chemical engineering↗

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS↗

Slug-flow synthesis of NCMA: Effect of substitution of cobalt with aluminum on the electrochemical performance of Ni-rich cathode for lithium-ion battery

Nickle-rich Li[Ni 1-x-y Co x Mn y ]O 2 (x, y≤0.1) (NCM) layered materials are known as promising cathode materials for next-generation lithium-ion batteries and electric vehicles owing to their high-reversible capacity and operating voltage of up to 3.6 vs Li/Li + . However, issues, such as irreversible phase transition, cation mixing, microcrack formation, thermal and structural stability of the material prevent its widespread adoption. Although, cation doping is a well-known technique to enhance the electrochemical performance of the NCM-based cathode material, the performance of the material is very sensitive to the doping amount. In this study, three Al-doped quaternary Ni-rich cathode materials Li[Ni 0.85 Co (0.1-x) Mn 0.05 Al x ]O 2 (where, x=0–0.04) (NCMA) are synthesized through three-phase slug-flow based continuous manufacturing process followed by high temperature calcination to study the effect of Aldoping on the performance of the cathode material while reducing Co. The slug flow-based production platform has several advantages, like particle size uniformity, high production rate, and homogeneity in elemental distribution. It is found that with an increase in Al content, the specific capacity decreases but the cyclic stability and rate capability increases. Furthermore, optimum Al-doping not only compensates for the adverse effect of low Co by decreasing the extent of cation mixing, but it also minimizes the electrode polarization and cracking of the particles.

25 ENERGY STORAGE↗

Rapid scalable fabrication of roll-to-roll slot-die coated flexible perovskite solar cells using intense pulse light annealing

Perovskite solar cells have achieved high efficiencies at the lab scale using batch processes that often may not be scalable. Processes that can be integrated into a continuous manufacturing platform, such as roll-to-roll, where several processes can be carried out sequentially are necessary to develop a new cost-competitive solar technology. In this work, intense pulsed light thermal post-processing is coupled with scalable slot-die coating and air knife evaporation in a high-speed roll-to-roll process of up to 2 m min –1 . The optimization of IPL energy parameters, web speeds, solution flow rates, and concentration of precursor inks yielded a champion power conversion efficiency of 11.24% for a 1 cm 2 roll-to-roll coated device. The overall processing time for a single layer in this process is reduced from minutes to seconds and the overall footprint of the manufacturing process is decreased. Furthermore, this demonstrates the promising capabilities for intensed pulsed light to reduce manufacturing costs and paves a roadmap for scalable and efficient PSCs on a roll-to-roll platform.

14 SOLAR ENERGY↗

Continuous Processing of Carbon Foam Products Made from Coal at Atmospheric Pressure

The main goal of the project was to create a continuous manufacturing process for carbon foam that operates at atmospheric pressure and can generate well-formed carbon foam panels and lightweight aggregates. This objective was accomplished and has enabled a platform where carbon foam products can be manufactured at significantly reduced cost and cycle time relative to the conventional high-pressure batch process, which in turn can enable the manufacture of much larger volumes of carbon foam. All these features should enable carbon foam to enter much larger markets and create meaningful demand for U.S. coal. Carbon foam panels and aggregate both consisted of at least 70 weight percent carbon per program requirements (typical was over 90-wt%), and at least 51 weight percent of the carbon was to be coal derived (typical was over 90-wt% carbon was from coal). Analyses regarding life cycle, technoeconomics, and final technological gaps have been documented in separate reports. This final report documents the methods used to attain the main goal and describes the technical results.

01 COAL, LIGNITE, AND PEAT↗

The NASA-Lewis/ERDA Solar Heating and Cooling Technology Program

The NASA Lewis Research Center plans to carry out a major role in the ERDA Solar Heating and Cooling Program. This role would be to create and test the enabling technology for future solar heating, cooling, and combined heating/cooling systems. The major objectives of the project are to achieve reduction in solar energy system costs, while maintaining adequate performance, reliability, life, and maintenance characteristics. The project approach is to move progressively through component, subsystem, and then system technology advancement phases in parallel with continuing manufacturing cost assessment studies. This approach will be accomplished principally by contract with industry to develop advanced components and subsystems. This advanced hardware will be tested to establish 'technology readiness' both under controlled laboratory conditions and under real sun conditions.

Couch, J. P.↗

A study of the possible effect of a thermal post cure on the mechanical properties of the 404 carbon-phenolic ring of the space shuttle solid rocket motor nozzle

Erratic pockets of erosion have occurred on the inner perimeter of the 404 rocket nozzle ring during liftoff firing. It is thought that it may be caused by pockets of volatile matter entrapped during manufacture. A thermal post cure was suggested as a possible means of outgassing such pockets, if they in fact do exist. To confirm an outgassing during a post cure and to establish a working upper temperature limit, thermal gravimetric and differential calorimetric analyses were made on a number of samples from two 404 rings supplied by the manufacturer. Continuous weight loss was observed over the temperature range explored (750 F) indicating outgassing, and a strong exothermic reaction occurs beginning about 390 F. Thus, an upper post cure temperature of 350 F is recommended. To determine the possible effect of a post cure on physical properties, the following tests will be made on matched sets of cured and post cured material: x-radiography (internal structure), linear dimensions, weight, porosity, cross ply thermal expansion, drop and double notch shear strengths, and tensional strength in the ply direction.

Giardini, A. A.↗

Design, fabrication and delivery of a miniature Cassegrainian concentrator solar array system

The optical design of the miniature Cassegrainian concentrator (MCC) element was improved for both offpoint and onpoint power capability. The cell stack design has shown no losses under the high short term thermal stresses imposed by component level test and is projected to be capable of greater than five years thermal cycle life in low Earth orbit. The structural design met all requirements for stiffness and flatness and requires adjustable inserts for fine tuning of the GFRP structure to meet flatness goals. The completed, fully populated small and large MCC panels deliverable under this contract perform electrically as expected. A solid acceptance inspection program to guarantee quality of all purchased parts, and continued manufacturing process improvements will make the MCC design a viable low cost alternative to standard flat panel technology. Minor improvements to the cell stack design of the MCC element can make significant improvements in both the performance and manufacturability of the MCC system.

Kruer, Mark A.↗

International Space Station (ISS) Environmental Control and Life Support System Status: 2003-2004

The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between April 2003 and March 2004. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.

Williams, David E.↗

International Space Station Environmental Control and Life Support System Status: 2005 - 2006

The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between March 2005 and February 2006. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.

Williams, David E.↗

International Space Station Environmental Control and Life Support System Status: 2006 - 2007

The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between March 2006 and February 2007. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.

Williams, David E.↗