Global Survey of the Concepts and Understanding of the Interfaces Between Nuclear Safety, Security, and Safeguards

There is increasing global discourse on how the elements of nuclear safety, security, and safeguards can be most effectively implemented in nuclear power programs. While each element is separate and unique, they must nevertheless all be addressed in a country’s laws and implemented via regulations and in facility operations. This topic is of particular interest to countries that are currently developing the infrastructure to support nuclear power programs. These countries want to better understand what is required by these elements and how they can manage the interfaces between them and take advantages of any synergies that may exist. They need practical examples and guidance in this area in order to develop better organizational strategies and technical capacities. This could simplify their legal, regulatory, and management structures and avoid inefficient approaches and costly mistakes that may not be apparent to them at this early stage of development. From the perspective of IAEA International Safeguards, supporting Member States in exploring such interfaces and synergies provides a benefit to them because it acknowledges that domestic safeguards in a country do not exist in a vacuum. Instead, it relies on a strong State System of Accounting and Control that is in turn dependent on a capable and independent regulatory body as well as a competent operator and technical staff. These organizations must account for and control nuclear material, communicate effectively, and manage and transmit complete and correct information to the IAEA in a timely manner. This, while in most cases also being responsible for the safety and security of their facilities. Seeking efficiencies in this process benefits international safeguards and nonproliferation. This paper will present the results of a global survey of current and anticipated approaches and practices by countries and organizations with current or future nuclear power programs on how they are implementing, or planning to implement, safety, security, and safeguards in their programs. The idea is to capture current knowledge and thinking on this topic and to identify common themes in organizations and management. It will also document the most commonly held ideas and perception (and misperceptions) of what it means to manage interfaces and take advantage of synergies for operating nuclear facilities and those that are building their infrastructures. It is desired that the results of this paper will inform the current discourse on this topic with some quantitative data and identify any general trends in understanding.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NASA/Navy Benchmarking Exchange (NNBE). Volume 1. Interim Report. Navy Submarine Program Safety Assurance

The NASA/Navy Benchmarking Exchange (NNBE) was undertaken to identify practices and procedures and to share lessons learned in the Navy's submarine and NASA's human space flight programs. The NNBE focus is on safety and mission assurance policies, processes, accountability, and control measures. This report is an interim summary of activity conducted through October 2002, and it coincides with completion of the first phase of a two-phase fact-finding effort.In August 2002, a team was formed, co-chaired by senior representatives from the NASA Office of Safety and Mission Assurance and the NAVSEA 92Q Submarine Safety and Quality Assurance Division. The team closely examined the two elements of submarine safety (SUBSAFE) certification: (1) new design/construction (initial certification) and (2) maintenance and modernization (sustaining certification), with a focus on: (1) Management and Organization, (2) Safety Requirements (technical and administrative), (3) Implementation Processes, (4) Compliance Verification Processes, and (5) Certification Processes.

SUBSAFE PROGRAM↗

Investigation of energy management strategies for photovoltaic systems - A predictive control algorithm

The present investigation is concerned with the formulation of energy management strategies for stand-alone photovoltaic (PV) systems, taking into account a basic control algorithm for a possible predictive, (and adaptive) controller. The control system controls the flow of energy in the system according to the amount of energy available, and predicts the appropriate control set-points based on the energy (insolation) available by using an appropriate system model. Aspects of adaptation to the conditions of the system are also considered. Attention is given to a statistical analysis technique, the analysis inputs, the analysis procedure, and details regarding the basic control algorithm.

Cull, R. C.↗

Docking Offset Between the Space Shuttle and the International Space Station and Resulting Impacts to the Transfer of Attitude Reference and Control

The Space Shuttle does not dock at an exact 90 degrees to the International Space Station (ISS) x-body axis. This offset from 90 degrees, along with error sources within their respective attitude knowledge, causes the two vehicles to never completely agree on their attitude, even though they operate as a single, mated stack while docked. The docking offset can be measured in flight when both vehicles have good attitude reference and is a critical component in calculations to transfer attitude reference from one vehicle to another. This paper will describe how the docking offset and attitude reference errors between both vehicles are measured and how this information would be used to recover Shuttle attitude reference from ISS in the event of multiple failures. During STS-117, ISS on-board Guidance, Navigation and Control (GNC) computers began having problems and after several continuous restarts, the systems failed. The failure took the ability for ISS to maintain attitude knowledge. This paper will also demonstrate how with knowledge of the docking offset, the contingency procedure to recover Shuttle attitude reference from ISS was reversed in order to provide ISS an attitude reference from Shuttle. Finally, this paper will show how knowledge of the docking offset can be used to speed up attitude control handovers from Shuttle to ISS momentum management. By taking into account the docking offset, Shuttle can be commanded to hold a more precise attitude which better agrees with the ISS commanded attitude such that start up transients with the ISS momentum management controllers are reduced. By reducing start-up transients, attitude control can be transferred from Shuttle to ISS without the use of ISS thrusters saving precious on-board propellant, crew time and minimizing loads placed upon the mated stack.

Helms, W. Jason↗

2017 NE-4 Nuclear Technologies Research and Development (NTRD) Achievements Report

Fiscal year (FY) 2017 initiated new and reestablished presidential and departmental nuclear energy priorities for the U.S. Department of Energy (DOE), Office of Nuclear Energy (DOE-NE) that will: • Support the Administration’s priorities to achieve U.S. energy dominance and economic prosperity through U.S. technology leadership • Support DOE-NE mission priorities and goals for the existing nuclear fleet, advanced reactor pipeline and national fuel cycle infrastructure • Focus on early stage research, and effective cooperation with industry, academia, and other government agencies • Propose investments to maintain and improve capabilities and infrastructure to conduct leading-edge science, research, and technology development. DOE-NE’s mission priorities will focus on the existing nuclear fleet, advanced reactor pipeline, and fuel cycle infrastructure. Therefore, the DOE Nuclear Technology Research and Development (NE-4) mission aligned to (1) support the research and development (R&D) of innovative reactor technologies that may offer improved safety, functionality, and affordability and (2) conduct research to reduce long-term technical barriers for advanced nuclear energy systems, including space fission systems. Key activities to execute this mission include: • To achieve the NE-4 mission priorities, two major programs with eight R&D campaigns are engaged in impactful research, development, demonstration, and deployment: Fuel Cycle Technologies (FCT) Program • Fuel Cycle Options Campaign evaluates complex fuel cycle options and provides performance metrics on various systems and scenarios to improve the knowledge of interdependencies between technologies and different systems. • Advanced Fuels Campaign performs science-based R&D on accident tolerant fuels in addition to advanced light-water reactor (LWR) fuel and transmutation fuel. • Joint Fuel Cycle Studies (JFCS) is a collaboration with the Republic of Korea to assess the feasibility and nonproliferation of electrochemical recycling to manage used fuel. • Material Recovery and Waste Form Development (MRWFD) Campaign researches advanced fuel cycle material recovery and waste management capabilities to improve fuel cycle performance with less processing and waste generation. • Material Protection, Control, and Accountability Technologies (MPACT) Program develops tools and capabilities to secure the next generation nuclear materials management and safeguards for nuclear fuel cycles. Advanced Reactor Technologies (ART) Program • Fast Reactors Campaign targets benefits in either resource utilization or waste management and possesses favorable features for small reactor applications and plutonium management. • Gas-Cooled Reactors Campaign seeks to raise the technological readiness of high temperature gas-cooled reactors (HTGRs) and other reactor concepts utilizing coated particle fuel, graphite, or helium coolant by performing high risk, enabling research and development that commercial developers are unable or unwilling to undertake in the current energy market. • ART Energy Conversion (EC) Project provides solutions to convert heat from an advanced reactor to useful products that support commercial application of the reactor designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculator for Agricultural Water Use Fractions in California

Improved quantification of agricultural water use efficiency is a primary focus of California's Water Conservation Act. The California Department of Water Resources (CDWR), after extensive stakeholder consultation, has published methods and indicators to help identify opportunities for improved efficiency of irrigation management at various spatial scales. Additional 2017 legislation directs water suppliers to quantify water use efficiency using the CDWR metrics to support preparation of agricultural water management plans. The IrriQuest calculator derives the Crop Consumptive Use Fraction (CCUF), a foundational metric relating seasonal crop evapotranspiration (ET) to total applied water. Satellite normalized difference vegetation index (NDVI) data are used to develop fractional canopy cover timeseries. Additional key inputs include daily reference ET, irrigation volume, irrigation method, precipitation, soil texture and crop type. IrriQuest estimates of seasonal crop ET show less than 10% mean absolute error compared to ground-based measurements of several annual and perennial crops monitored by sensor deployment in commercial fields. Two additional indicators build on CCUF. The Agronomic Water Use Fraction adds consideration of water applied for beneficial purposes such as pre-plant soil preparation, soil salinity management, and climate control. Total Water Use Fraction additionally accounts for water applied for environmental purposes such as maintenance of wetland and riparian habitat. A convenient on-line portal is under development for CCUF estimation and a standalone spreadsheet is available for computation of all three use fractions.

Calculator↗

How Configuration Management (CM) Can Help Project Teams To Innovate and Communicate

Traditionally, CM is relegated to a support role in project management activities. CM s traditional functions of identification, change control, status accounting, and audits/verification are still necessary and play a vital role. However, this presentation proposes CM s role in a new and innovative manner that will significantly improve communication throughout the organization and, in turn, augment the project s success. CM s new role is elevated to the project management level, above the engineering or sub-project level in the Work Breakdown Structure (WBS), where it can more effectively accommodate changes, reduce corrective actions, and ensure that requirements are clear, concise, and valid, and that results conform to the requirements. By elevating CM s role in project management and orchestrating new measures, a new communication will emerge that will improve information integrity, structured baselines, interchangeability/traceability, metrics, conformance to standards, and standardize the best practices in the organization. Overall project performance (schedule, quality, and cost) can be no better than the ability to communicate requirements which, in turn, is no better than the CM process to communicate project decisions and the correct requirements.

Cioletti, Louis↗

Incorporating Residential Smart Electric Vehicle Charging in Home Energy Management Systems

Electric vehicles (EVs) are expected to drastically increase residential electricity consumption and could provide a significant source of flexible demand. Aggregating smart EV charge controllers with other smart home devices through a home energy management system can lead to more optimal outcomes that benefit homeowners, utilities, and grid operators. Control strategies should consider occupant convenience by accounting for the need for fully charged EVs near the EV departure time. In this paper, we develop an EV charging framework that accounts for occupant convenience using OCHRE, a residential energy model, and foresee, a home energy management system. We simulate a community with high EV penetration and show that integrated, smart EV charging reduces peak demand and smooths night-time energy consumption. Simulation results show that the proposed control strategy nearly eliminates peak period EV charging and reduces the daily peak demand from EVs by 23%.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Demonstration of Intelligent HVAC Load Management With Deep Reinforcement Learning: Real-World Experience of Machine Learning in Demand Control

We report that buildings account for 40% of total primary energy consumption and 30% of all CO 2 emissions worldwide. A large portion of building energy consumption is due to heating, ventilation, and air-conditioning (HVAC) systems. In the summer, for example, more than 50% of a building’s electricity consumption is used for cooling. With proper energy management, buildings can provide load shifting, peak shaving, frequency regulation, and many other demand response services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

Turbine Electrified Energy Management↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

transient↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

transient↗

EDF industrial strategy for the management of radioactive waste - 15204

In France, EDF is in charge of electronuclear power operation since the sixties and consequently has to manage radioactive waste. Radioactive waste management is based on the control of each industrial step, taking into account the classification by activity level and radioactive half life. The main steps are to limit waste quantities at the generation stage, sort out non-rad and recoverable items from the waste, recycle, treat and package the radioactive waste as soon as it is generated, limit the use of interim storage, prepare and achieve as soon as reasonably practicable conditioning and disposal. EDF aims to empower operators in charge of NPP operating and of decommissioning and to centralize interfaces with the stakeholders in order to pool management routes and to guarantee the consistency of our industrial policy. The French regulatory framework for the management of radioactive waste and material is set by the French 2006 planning Act, in line with the European Directive. The legal framework structures interactions between EDF and the regulatory bodies (Nuclear Safety Authority, General Directorate for Energy and Climate), the French National Radioactive Waste Management Agency (ANDRA) and other waste producer (mainly AREVA Company and CEA). Regarding short lived waste, management routes are in current operation for the large majority of this waste generated both by power plants in service and during decommissioning. EDF is working on new management route for metallic materials knowing the future evolution of deposits is the field of large refit and decommissioning activities. Regarding long lived waste, disposal development represents a major stake for EDF. EDF contributes to design studies of the geological disposal center and collaborates with ANDRA for the acceptance of future national waste disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporating Residential Smart Electric Vehicle Charging in Home Energy Management Systems: Preprint

Electric vehicles are expected to drastically increase residential electricity consumption and provide a significant source of flexible demand. Aggregating smart EV charge controllers with other smart home devices through a home energy management system can lead to more optimal outcomes that benefit homeowners, utilities, and grid operators. Control strategies must account for occupant convenience by considering the need for fully charged EVs at any time of day. In this paper, we develop an EV charging framework that accounts for occupant convenience using OCHRE, a residential energy model, and foresee, a home energy management system. We simulate a community with high EV penetration and show that integrated, smart EV charging reduces peak demand and smooths night-time energy consumption. Simulation results show that the proposed control strategy nearly eliminates peak period EV charging and reduces the daily peak demand from EVs by 23%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WM-SVS-TP-003, Rev. 0, effective date 10/15/2015, WM-SVS Characterization Services User-Performed Calibration (UPC) Program

Los Alamos National Laboratory (LANL) Procedure P330-2, Control and Calibration of Measuring and Test Equipment (M&TE), requires the establishment of a Measurement Assurance Program and/or a User-Performed Calibration (UPC) Process, as applicable. This UPC has been developed in accordance with the authorization provided in QPA-VAR-2013. This program ensures that qualified individuals perform measurement control and develop measurement control and calibration procedures. Nondestructive analysis (NDA) instruments used for accountability, confirmation, and verification measurements are maintained by the Waste Management Services (WM-SVS) Characterization Services Team. NDA reference standards used for instrument control and calibration are certified for use by the Standards and Calibration Laboratory (S&CL) before use. The Characterization Services Team performs the measurements, develops procedures for performing instrument UPC, and ensures the measurement systems’ control before measurements are performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Standardizing power monitoring and control at exascale

Power API-the result of collaboration among national laboratories, universities, and major vendors-provides a range of standardized power management functions, from application-level control and measurement to facility-level accounting, including real-time and historical statistics gathering. Here, support is already available for Intel and AMD CPUs and standalone measurement devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fusing TensorFlow with building energy simulation for intelligent energy management in smart cities

Buildings account for 35% of the global final energy demand. Efficiency improvements and advanced control strategies have a significant impact in the reduction of energy costs and CO2 emissions. Building energy simulation is widely used to help planners, contractors, and building owners analyse diverse options regarding the planning and management of energy consumption in buildings. Furthermore, recent advances in data processing and computing have led to the development of sophisticated machine learning algorithms that can learn from large datasets, e.g., sensor data from buildings, and use them to develop building-specific adaptive and automatic energy controllers. Control algorithms, such as deep reinforcement learning can tune themselves, are model-free, and economical to implement. In this paper, we introduce an integrated simulation environment that combines CitySim, a fast building energy simulator, and TensorFlow, a platform for efficient implementation of advanced machine learning algorithms. The integration is achieved via Keras - an API for TensorFlow - and a set of text and csv files for data transfer between the applications. This new environment will allow researchers to investigate novel learning control algorithms, and demonstrate their robustness and potential for diverse applications in the built environment. We present two case studies for energy savings and demand response, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗