Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Implementation of ASHRAE Guideline 36 Control Logic into Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP)

This report presents the initial field test procedure and results for ASHRAE Guideline 36 control logic. The US Department of Energy’s Oak Ridge National Laboratory’s (ORNL’s) two-story Flexible Research Platform (FRP-2) was selected as a test building. The rooftop unit (RTU) system serves as the building’s primary cooling system, and each variable air volume (VAV) box with an electric reheat coil serves as the building’s heating system along with RTU gas furnace. In this study, the control for the RTU and VAV box adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. Each story of the FRP-2 building has 5 office zones (thermal zones), for a total of 10 zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of rows arrangement, soil management, and rainfall characteristics on water and soil losses in Italian sloping vineyards

Highlights: • GC effectiveness varies according to the type of rainfall event and row orientation. • Rows orientation along contour lines prevents runoff also when CT is adopted. • Highest runoff and soil losses depend on “long-lasting” or “intense” events. • Rainfall depth and rainfall maximum intensity count in predicting erosion rate. Erosional processes are highly affected by seasonal climatic fluctuations and soil management practices. Controlled grass cover is one of the most used soil conservation practices adopted in temperate climates, even if the protective effect of grass cover may decrease according to seasonal pattern. This technique is effective and, thus, widely adopted in the inter-rows of orchards such as olives, citrus or vineyards. This study reports the erosive events recorded in two different rain-fed hillslope vineyards with different rows orientation located in the Monferrato region, NW Italy. The study is addressed at compare the effects of different inter-row managements and rainfall characteristics on runoff and soil loss in hillslope vineyards (average slope from 15% to 35%). Rainfall, runoff and erosion variables were monitored in hydraulically bounded vineyard plots, where the inter-rows were managed with tillage and grass cover. Seventy-two erosive events were recorded in the period 1992–1996 in two vineyard plots with rows along the contour lines while 86 erosive events were recorded in two plots with rows up-and-down the slope from 2000 to 2014 (158 erosive events and four plots in total). Events were classified according to rainfall characteristics as “long-lasting”, “intense” and “normal”. In plots with rows along the contour lines, “intense” events were responsible for the highest mean soil loss in tilled plots (0.7 Mg ha{sup −1}) with very high erosion rates (12.3 Mg ha{sup −1}) observed during a single storm. In plots with rows up-and-down the slope the highest erosion rates, 21.2 and 3.4 Mg ha{sup −1}, were recorded during fall “long-lasting” events in the tilled and grass cover plots respectively. The grass cover proved to be effective in decreasing runoff and soil losses during most of the events (at least 68% and 61% of the occurrences, respectively) reducing soil losses especially during summer storms when most of the “intense” events occured. Furthermore, the results show the fundamental role of contour-slope row orientation in reducing runoff and soil losses, disregarding the inter-rows soil management that is adopted.

54 ENVIRONMENTAL SCIENCES↗

Analysis of MTDC Inertia Emulation Impact on Connected AC Systems

The frequency decoupling effect of the voltage source converter (VSC)-based high voltage dc (HVDC) transmission makes frequency support unavailable between two ac subsystems interconnected by the HVDC link. Recently, several algorithms have been proposed and demonstrated to improve the ac system stability by implementing inertia emulation (IE) functions in the HVDC VSC stations. However, the capability of the VSC-HVDC to achieve the IE control is not clear. According to the previous research, the IE control strategy has been studied without concerning the impact of the practical control process, which will introduce some time delay into the IE realization. In this paper, a detailed multi-terminal HVDC VSC control module, including the phase-locked loop (PLL) and low pass filter (LPF), is considered in order to analyze the multi-terminal HVDC network impact on the IE performance. The analysis indicates that the frequency performance of the ac network with IE integrated HVDC transmission can be nearly as good as that directly connected with the ac subsystem which involves a high penetration of conventional generation units, except for the short time delay introduced by the VSC control modules. The effectiveness of IE performance will be compromised if the response delay is significant. The simulation results have verified the analysis.

Wang, Shuyao↗

Influence of soil heterogeneity on soybean plant development and crop yield evaluated using time-series of UAV and ground-based geophysical imagery

Understanding the interactions among agricultural processes, soil, and plants is necessary for optimizing crop yield and productivity. This study focuses on developing effective monitoring and analysis methodologies that estimate key soil and plant properties. These methodologies include data acquisition and processing approaches that use unmanned aerial vehicles (UAVs) and surface geophysical techniques. In particular, we applied these approaches to a soybean farm in Arkansas to characterize the soil–plant coupled spatial and temporal heterogeneity, as well as to identify key environmental factors that influence plant growth and yield. UAV-based multitemporal acquisition of high-resolution RGB (red–green–blue) imagery and direct measurements were used to monitor plant height and photosynthetic activity. We present an algorithm that efficiently exploits the high-resolution UAV images to estimate plant spatial abundance and plant vigor throughout the growing season. Such plant characterization is extremely important for the identification of anomalous areas, providing easily interpretable information that can be used to guide near-real-time farming decisions. Additionally, high-resolution multitemporal surface geophysical measurements of apparent soil electrical conductivity were used to estimate the spatial heterogeneity of soil texture. By integrating the multiscale multitype soil and plant datasets, we identified the spatiotemporal co-variance between soil properties and plant development and yield. Our novel approach for early season monitoring of plant spatial abundance identified areas of low productivity controlled by soil clay content, while temporal analysis of geophysical data showed the impact of soil moisture and irrigation practice (controlled by topography) on plant dynamics. Our study demonstrates the effective coupling of UAV data products with geophysical data to extract critical information for farm management.

54 ENVIRONMENTAL SCIENCES↗

Quantum Control Landscapes Beyond the Dipole Approximation: Controllability, Singular Controls, and Resources

We investigate the control landscapes of closed n-level quantum systems beyond the dipole approximation by including a polarizability term in the Hamiltonian. The latter term is quadratic in the control field. Theoretical analysis of singular controls is presented, which are candidates for producing landscape traps. The results for considering the presence of singular controls are compared to their counterparts in the dipole approximation (i.e., without polarizability). A numerical analysis of the existence of traps in control landscapes for generating unitary transformations beyond the dipole approximation is made upon including the polarizability term. An extensive exploration of these control landscapes is achieved by creating many random Hamiltonians which include terms linear and quadratic in a single control field. The discovered singular controls are all found not to be local optima. This result extends a great body of recent work on typical landscapes of quantum systems where the dipole approximation is made. We further investigate the relationship between the magnitude of the polarizability and the fluence of the control resulting from optimization. It is also shown that including a polarizability term in an otherwise uncontrollable dipole coupled system removes traps from the corresponding control landscape by restoring controllability. We numerically assess the effect of a polarizability term on a known example of a particular three-level Λ-system with a second order trap in its control landscape. It is found that the addition of the polarizability removes the trap from the landscape. The general practical control implications of these simulations are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum optical microcombs

We present that a key challenge for quantum science and technology is to realize large-scale, precisely controllable, practical systems for non-classical secured communications, metrology and, ultimately, meaningful quantum simulation and computation. Optical frequency combs represent a powerful approach towards this goal, as they provide a very high number of temporal and frequency modes that can result in large-scale quantum systems. The generation and control of quantum optical frequency combs will enable a unique, practical and scalable framework for quantum signal and information processing. Here, we review recent progress on the realization of energy–time entangled optical frequency combs and discuss how photonic integration and the use of fibre-optic telecommunications components can enable quantum state control with new functionalities, yielding unprecedented capability.

42 ENGINEERING↗

Colloidal quantum dot lasers

We report semiconductor nanocrystals represent a promising class of solution-processable optical-gain media that can be manipulated via inexpensive, easily scalable colloidal techniques. Due to their extremely small sizes (typically <10 nm), their properties can be directly controlled via effects of quantum confinement; therefore, they are often termed colloidal quantum dots (CQDs). In addition to size-tunable emission wavelengths, CQDs offer other benefits for lasing applications, including low optical-gain thresholds and high temperature stability of lasing characteristics. Recent progress in understanding and practical control of processes impeding light amplification in CQDs has resulted in several breakthroughs, including the demonstration of optically pumped continuous-wave lasing, the realization of optical gain with direct current electrical injection and the development of dual-function electroluminescent devices that also operate as optically pumped lasers. The purpose of this Review is to assess the status of the field of CQD lasing and discuss the existing challenges and opportunities. A particular focus is on approaches for suppressing nonradiative Auger recombination, novel optical-gain concepts enabled by strong exciton-exciton interactions and controlled CQD charging, effects of nanocrystal form factors on light amplification and practical architectures for realizing electrically pumped CQD lasers. This overview suggests that the accumulated knowledge, along with the approaches developed for manipulating the optical-gain properties of colloidal nanostructures, perfectly position the CQD field for successfully addressing a long-standing challenge: the realization of CQD-based laser diodes. Colloidal quantum dots are promising materials for realizing versatile, wavelength-tunable, solution-processed lasers. This Review surveys recent advances in colloidal quantum dot lasing, provides an in-depth analysis of outstanding challenges and discusses a path forward to implementing technologically viable lasing devices.

36 MATERIALS SCIENCE↗

Energy savings potential from improved building controls for the US commercial building sector

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

Fernandez, Nick↗

Analysis of Control Behavior in Eco-Driving Speed Optimization Using Pontryagin’s Minimum Principle

The energy efficiency of autonomous vehicles can be improved by selecting an optimized speed profile. Energy savings can be maximized by performing control optimization with knowledge of the powertrain characteristics and future driving conditions. Previous studies have shown that Pontryagin’s minimum principle (PMP) performs well in vehicle speed optimization problems. Building on the methods proposed in previous studies, the contribution of this study is to derive meaningful observations from the concepts and results of PMP to enhance the understanding of the control problem. In particular, the switching behavior of the control mode is analyzed with supportive variables, such as ξ and mv, which dictates the changes in the control modes. Additionally, the existence of the singular control is analyzed, which helps in understanding the cruise driving in the control problem. Finally, we obtain several solutions that satisfy various boundary conditions along with a map of the reachable states, and discuss the impact of cruise driving. This is helpful for designing practical control concepts for real-world applications based on this map. Previous studies have contributed significantly to this control problem; however, this study provides a better understanding of the issue and offers guidance and inspiration for future real-world applications based on these meaningful observations.

33 ADVANCED PROPULSION SYSTEMS↗

MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability metrics: Different cultures/practices affecting the effectiveness of methods and metrics. Show examples of quality assurance workflows, Statistical process control, that monitor the treatment planning and delivery process to identify errors. To learn to identify and prioritize risks and QA procedures in radiation oncology. Try to answer the question: Can a quality assurance program aided by quality assurance metrics help minimize errors and ensure safe treatment delivery. Should such metrics be institution specific.

07 ISOTOPE AND RADIATION SOURCES↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Overview of the national ignition facility

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory will be the world's largest and most powerful laser system for inertial confinement fusion (ICF) and experiments studying high energy density (HED) science. NIF is a 192 beam Nd-glass laser facility that will produce 1.8 MJ, 500 TW of ultraviolet light making it over fifty times more energetic than present ICF facilities. The NIF Project began in 1995 and is scheduled for completion in 2009. Ignition experiments on NIF, which will use tritium, are scheduled to begin in 2010. Tritium will arrive at the facility in individual target assemblies. The assemblies will be mounted to the Cryogenic Target Positioner (TARPOS), which provides the cryogenic cooling systems necessary to complete the formation of the ignition target's fuel ice layer. It also provides the positioning system that transports and holds the target at the center of the NIF chamber during a shot. After a shot, unburned tritium will be captured by the cryopumps. Upon regeneration, the cryopump effluent will be directed to the Tritium Processing System, part of NIF's. Personnel and Environmental Protection Systems. These systems also include, local contamination control systems, area and stack tritium monitoring systems, a decontamination area, and waste packaging and characterization capability. This equipment will be used along with standard contamination control practices to manage the tritium hazard to workers and to limit releases to the environment to negligibly small amounts. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reinforcement learning building control approach harnessing imitation learning

Reinforcement learning (RL) has shown significant success in sequential decision making in fields like autonomous vehicles, robotics, marketing and gaming industries. This success has attracted the attention to the RL control approach for building energy systems which are becoming complicated due to the need to optimize for multiple, potentially conflicting, goals like occupant comfort, energy use and grid interactivity. However, for real world applications, RL has several drawbacks like requiring large training data and time, and unstable control behavior during the early exploration process making it infeasible for an application directly to building control tasks. To address these issues, an imitation learning approach is utilized herein where the RL agents starts with a policy transferred from accepted rule based policies and heuristic policies. This approach is successful in reducing the training time, preventing the unstable early exploration behavior and improving upon an accepted rule-based policy - all of these make RL a more practical control approach for real world applications in the domain of building controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

XMCD and XMCD-PEEM Studies on Magnetic-Field-Assisted Self-Assembled 1D Nanochains of Spherical Ferrite Particles

Quasi-1D nanochains of spherical magnetic ferrite particles with a homogeneous particle size of ≈200 nm and a micrometer-sized chain length are fabricated in this paper via a self-assembly method under an external magnetic field. This assisting magnetic field (H assist ), applied during synthesis, significantly modifies the distribution of the Fe 2+ O h , Fe 3+ T d , and Fe 3+ O h cations in the chains, as demonstrated by X-ray magnetic circular dichroism (XMCD) combined with theoretical analysis. This provides direct evidence of the nontrivial role of external synthetic conditions for defining the crystal chemistry of nanoscale ferrites and in turn their magnetic properties, providing an extra degree of freedom for intentional control over the performances of 1D magnetic nanodevices for various applications. Magnetic imaging, performed via XMCD in photoemission electron microscopy, further shows the possibility of creating and trapping a series of adjacent magnetic domain walls in a single chain, suggesting that there is great application potential for these nanochains in 1D magnetic nanodevices, as determined by field- or current-driven domain wall motions. Finally, practical control over the magnetic properties of the nanochains is also achieved by extrinsic dopants of cobalt and zinc, which are observed to occupy the ferrite ionic sites in a selective manner.

1D nanochains↗

Site closeout of the Linde FUSRAP Site, Tonawanda, New York - 15441

The US Army Corps of Engineers (USACE) Buffalo District, with assistance from Argonne National Laboratory (Argonne), prepared a Site Closeout Report (SCOR) for the Linde Formerly Utilized Sites Remedial Action Program (FUSRAP) Site in accordance with Engineer Regulation (ER) 200-1-4 [1]. Under FUSRAP, USACE is authorized to investigate, and clean up or control sites contaminated as the result of actions by the Atomic Energy Commission (AEC) and its predecessor, the Manhattan Engineer District (MED), in support of the nation's early atomic energy and weapons program. The SCOR documents response actions conducted at the Linde FUSRAP Site between 1996 and 2013. These response actions include two non-time-critical removal actions and long-term remedies associated with the three operable units (OUs) at the site: 1) soils and structure surfaces (except Building 14), 2) Building 14, and 3) groundwater. The report summarizes the site history, previous investigations, selected remedies, remedial actions, waste disposal, community involvement, monitoring results, recycling, quality assurance/quality control practices, post-remediation dose assessment, remedial costs, and five year review requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Information or resolution: Which is required from an SEM to study bulk inorganic materials?: Evaluate SEMs’ practical performance

Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energydispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. Finally, for an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly affect the usability of the SEM.

36 MATERIALS SCIENCE↗

Energy Savings for Occupancy-Based Control (OBC) of Variable-Air-Volume (VAV) Systems

Terminal boxes usually serve a single building zone, controlling the air-flow rate to the zone and reheating the air when it is too cool. Each terminal box has a minimum air-flow rate that ensures the ventilation requirements of the occupants of the zone served are met. This minimum air-flow rate is maintained at a constant value based on the design occupancy of the zone, which often corresponds to the maximum occupancy, because measurements of actual occupancy are not currently used to adjust the flow rate. Therefore, the minimum flow rate must meet the ventilation needs of the fully occupied zone. The total flow rate may be higher than the minimum to provide adequate cooling or heating, but the minimum for ventilation should always be met. In practice, control system integrators and installers often set the cooling minimum air-flow rate for ventilation to between 30% and 50% of the maximum air-flow rate of the terminal box. Building occupancy, however, varies dynamically. Conference rooms, cafeterias, auditoriums, and other assembly spaces are often unoccupied for significant periods of time. Office occupancy varies during the course of a work day, from day to day, and over the longer term because of attendance of meetings elsewhere, business travel, changing room functions, and variations in staffing. The resulting over-ventilation, during times when the space has less than maximum occupancy or is unoccupied, wastes significant fan energy and causes discomfort for occupants in some spaces (e.g., conference rooms) from overcooling or overheating, especially in interior zones that do not have reheat in the terminal boxes. Common occupancy sensors, which measure whether occupants are present or not, are commonly used for lighting control in conference rooms and other spaces with variable occupancy. They could be used to enable a terminal box to be switched to an occupied standby mode in which the air-flow rate is set to zero when no occupants are in the zone the box serves. If advanced occupancy sensors, which count the actual number of occupants in a room, were used to control terminal boxes, the minimum air-flow rate set point for the terminal box could be reset dynamically based on the actual occupancy sensed. This study evaluates the savings potential from use of occupancy-based control (OBC) of terminal boxes for large office buildings with variable-air-volume (VAV) heating, ventilating and air-conditioning (HVAC) systems using both common occupancy sensors and advanced occupancy sensors.

Zhang, Jian↗