Search NASASearch

SEARCH · Search NASA

Results for “Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Reconstruction errors in digital-to-analog conversion.

Error could theoretically be found as a function of time, midway between any two arbitrarily placed sample points. However, the analysis and the result would be difficult to use. As an alternative, worst-case instantaneous errors can be evaluated near the base-line crossing and at the peak of the analog signal. Location of sample points affects the error values obtained, but use of the points provides a means of comparing different reconstruction techniques. Zero-order conversion is discussed together with first-order conversion, second-order conversion, and third-order conversion.

Dotson, W. P., Jr.

Solar energy, its conversion and utilization

The work being carried out at the University of Florida Solar Energy and Energy Conversion Laboratory in converting solar energy, our only income, into other needed and useful forms of energy is described. A treatment such as this demonstrates, in proper perspective, how solar energy can benefit mankind with its many problems of shortages and pollution. Descriptions were given of the conversion processes, equipment, and performance. The testing of materials, solar water heating, space heating, cooking and baking, solar distillation, refrigeration and air-conditioning, work with the solar furnace, conversion to mechanical power, hot air engines, solar-heated sewage digestion, conversion to electricity, and other devices will be discussed.

Farber, E. A.

High-quantum-efficiency infrared up-conversion.

Experimental study in which 100% conversion of infrared photons into visible photons was achieved through three wave interactions in a nonlinear medium. The first experimental evidence of overconversion is presented, and the classical theory of up-conversion in the high-conversion-efficiency region is confirmed. A laser pump light feedback technique is described that promises to make the process practical with modestly powerful pump lasers and less than perfect nonlinear crystals. The nonlinear medium used was a LiIO3 crystal that cannot be 90-deg phase-matched. The 'walk off' that resulted helped make possible the attainment of 100% conversion efficiency.

Gurski, T. R.

Radiation energy conversion in space; Conference, 3rd, NASA Ames Research Center, Moffett Field, Calif., January 26-28, 1978, Technical Papers

Concepts for space-based conversion of space radiation energy into useful energy for man's needs are developed and supported by studies of costs, material and size requirements, efficiency, and available technology. Besides the more studied solar power satellite system using microwave transmission, a number of alternative space energy concepts are considered. Topics covered include orbiting mirrors for terrestrial energy supply, energy conversion at a lunar polar site, ultralightweight structures for space power, radiatively sustained cesium plasmas for solar electric conversion, solar pumped CW CO2 laser, superelastic laser energy conversion, laser-enhanced dynamics in molecular rate processes, and electron beams in space for energy storage.

Billman, K. W.

Status and summary of laser energy conversion

This paper presents a survey of the status of laser energy converters. Since the inception of these devices in the early 1970's, significant advances have been made in understanding the basic conversion processes. Numerous theoretical and experimental studies have indicated that laser energy can be converted at wavelengths from the ultraviolet to the far-infrared. These converters can be classified into five general categories: photovoltaics, heat engines, thermoelectronic, optical diode, and photochemical. The conversion can be directly into electricity (such as the photovoltaic, thermoelectronic, and optical diode) or it can go through an intermediate stage of conversion to mechanical energy, as in the heat engines. The photochemical converters result in storable energy such as hydrogen. Projected conversion efficiencies range from about 30% for the photochemical to nearly 75% for the heat engines.

Lee, G.

Cogeneration Technology Alternatives Study (CTAS). Volume 3: Energy conversion system characteristics

Six current and thirty-six advanced energy conversion systems were defined and combined with appropriate balance of plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a frame work for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Fuel energy savings of 10 to 25 percent were predicted compared to traditional on site furnaces and utility electricity. With the variety of industrial requirements, each advanced technology had attractive applications. Fuel cells indicated the greatest fuel energy savings and emission reductions. Gas turbines and combined cycles indicated high overall annual savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal derived fuels, or coal with advanced fluid bed combustion or on site gasifications. Data and information for both current and advanced energy conversion technology are presented. Schematic and physical descriptions, performance data, equipment cost estimates, and predicted emissions are included. Technical developments which are needed to achieve commercialization in the 1985-2000 period are identified.

Source record

Kinetics and mechanism of the oxidation of S(IV) by ozone in aqueous solution with particular reference to SO2 conversion in nonurban tropospheric clouds

Results are presented from a laboratory study of the kinetics of the S(IV)-O3 reaction in aqueous solution, including measurements of the effects of UV radiation, dissolved transition metals, and an antioxidant (hydroquinone) on the rate. On the basis of the results, relative rates of S(IV) conversion by O3 in tropospheric cloud water are compared with those predicted for H2O2 and for O2. The reaction mechanism is discussed, with an outline given of the elements of a possible reaction scheme. Application of the rate constants obtained to SO2 conversion in cloud water predicts conversion rates by ozone to be competitive with those by H2O2 at pH above about 4.5 and to dominate at pH above about 5.5. It is pointed out that since these pH's are typical for nonurban tropospheric cloud water, ozone is a potentially important contributor to the overall oxidative conversion of SO2 to sulfate in the nonurban troposphere.

Maahs, H. G.

User alternatives in post-processing for raster-to-vector conversion

A number of Landsat-based coniferous forest stratum maps have been created of the Eldorado National Forest in California. These maps were produced in raster image format which is not directly usable by the U.S. Forest Service's vector-based Wildland Resource Information System (WRIS). As a solution, raster-to-vector conversion software has been developed for processing classified images into polygonal data structures. Before conversion, however, the digital classification images must be simplified to remove high spatial variance ('noise', 'speckle') and meet a USFS ten acre minimum requirement. A post-processing (simplification) strategy different from those commonly used in raster image processing may be desired for preparing maps for conversion to vector format, because simplification routines typically permit diagonal connections in the process of reclassifying pixels and forming new polygons. Diagonal connections are often undesirable when converting to vector format because they permit polygons to effectively cross over each other and occupy a common location. Three alternative methodologies are discussed for simplifying raster data for conversion to vector format.

Logan, T. L.

Dynamic Conversion Working Group Summary

The potential of dynamic conversion devices for use in solar and nuclear dynamic space power systems was addressed. Conversion systems considered were based on the use of Brayton, Stirling and Rankine cycles. Both organic and liquid metal Rankine cycles were included. The basic system considerations were: mission requirements, system attributes, system options, technology issues and constraints, and priorities of needed technology development. Mission requirements, where dynamic conversion was considered enabling technology, were identified along with the associated power levels and potential energy sources. When considering the system options special attention was given to recommend operating temperatures and other significant discriminators. A list of prioritized tasks considered important for the successful development of dynamic conversion systems for 1995 and beyond was compiled.

Chaffee, N.

Planetary image conversion task

The Planetary Image Conversion Task group processed 12,500 magnetic tapes containing raw imaging data from JPL planetary missions and produced an image data base in consistent format on 1200 fully packed 6250-bpi tapes. The output tapes will remain at JPL. A copy of the entire tape set was delivered to US Geological Survey, Flagstaff, Ariz. A secondary task converted computer datalogs, which had been stored in project specific MARK IV File Management System data types and structures, to flat-file, text format that is processable on any modern computer system. The conversion processing took place at JPL's Image Processing Laboratory on an IBM 370-158 with existing software modified slightly to meet the needs of the conversion task. More than 99% of the original digital image data was successfully recovered by the conversion task. However, processing data tapes recorded before 1975 was destructive. This discovery is of critical importance to facilities responsible for maintaining digital archives since normal periodic random sampling techniques would be unlikely to detect this phenomenon, and entire data sets could be wiped out in the act of generating seemingly positive sampling results. Reccomended follow-on activities are also included.

Martin, M. D.

Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 4: Preliminary nonscanner models and count conversion algorithms

Two count conversion algorithms and the associated dynamic sensor model for the M/WFOV nonscanner radiometers are defined. The sensor model provides and updates the constants necessary for the conversion algorithms, though the frequency with which these updates were needed was uncertain. This analysis therefore develops mathematical models for the conversion of irradiance at the sensor field of view (FOV) limiter into data counts, derives from this model two algorithms for the conversion of data counts to irradiance at the sensor FOV aperture and develops measurement models which account for a specific target source together with a sensor. The resulting algorithms are of the gain/offset and Kalman filter types. The gain/offset algorithm was chosen since it provided sufficient accuracy using simpler computations.

Halyo, Nesim

Condenser design for AMTEC power conversion

The condenser and the electrodes are the two elements of an alkali metal thermal-to-electric conversion (AMTEC) cell which most greatly affect the energy conversion performance. A condenser is described which accomplishes two critical functions in an AMTEC cell: management of the fluid under microgravity conditions and optimization of conversion efficiency. The first function is achieved via the use of a controlled surface shape, along with drainage grooves and arteries to collect the fluid. Capillary forces manage the fluid in microgravity and dominate hydrostatic effects on the ground so the device is ground-testable. The second function is achieved via a smooth film of highly reflective liquid sodium on the condensing surface, resulting in minimization of parasitic heat losses due to radiation heat transfer. Power conversion efficiencies of 25 percent to 30 percent are estimated with this condenser using present technology for the electrodes.

Crowley, Christopher J.

Conversion of energy in cross-sectional divergences under different conditions of inflow

This investigation treats the conversion of energy in conically divergent channels with constant opening ratio and half included angle of from 2.6 to 90 degrees, the velocity distribution in the entrance section being varied from rectangular distribution to fully developed turbulence by changing the length of the approach. The energy conversion is not completed in the exit section of the diffuser; complete conversion requires a discharge length which depends upon the included angle and the velocity distribution in the entrance section. Lastly, a spiral fan was mounted in the extreme length and the effect of the spiral flow on the energy conversion in the cross-sectional divergence explored.

Peters, H

A Flight Study of the Conversion Maneuver of a Tilt-Duct VTOL Aircraft

Flight records are presented from an early flight test of a wing-tip mounted tilting-ducted-fan, vertical-take-off and landing (VTOL) aircraft configuration. Time histories of the aircraft motions, control positions, and duct pitching-moment variation are presented to illustrate the characteristics of the aircraft in hovering, in conversion from hovering to forward flight, and in conversion from forward flight to hovering. The results indicate that during essentially continuous slow level- flight conversions, this aircraft experiences excessive longitudinal trim changes. Studies have shown that the large trim changes are caused primarily by the variation of aerodynamic moments acting on the duct units. Action of the duct-induced downwash on the horizontal stabilizer during the conversion also contributes to the longitudinal trim variations. Time histories of hovering and slow vertical descent in the final stages of landing in calm air show angular motions of the aircraft as great as +/- 10 deg. about all axes. Stick and pedal displacements required to control the aircraft during the landing maneuver were on the order of 50 to 60 percent of the total travel available.

Tapscott, Robert J.

Very-high-frequency dc-to-dc conversion and regulation in the low-megahertz range.

Anticipated new mission requirements have motivated research on very-high-frequency (VHF) regulated dc-to-dc converters to operate at conversion frequencies in the low-megahertz range. State-of-the-art electronic components for VHF operation are discussed. Two different converter configurations, one using proportional control and having a conversion frequency of 0.1 MHz and the other using bistable control and having a conversion frequency of 3.8 MHz, are presented to indicate converter performance in this VHF region. Converter losses, which are of prime importance at these frequencies, are discussed and possible means of reducing these losses are suggested.

Feng, S. Y. M.

Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 1: Executive summary

A data base for the comparison of advanced energy conversion systems for utility applications using coal or coal-derived fuels was developed. Estimates of power plant performance (efficiency), capital cost, cost of electricity, natural resource requirements, and environmental intrusion characteristics were made for ten advanced conversion systems. Emphasis was on the energy conversion system in the context of a base loaded utility power plant. All power plant concepts were premised on meeting emission standard requirements. A steam power plant (3500 psig, 1000 F) with a conventional coal-burning furnace-boiler was analyzed as a basis for comparison. Combined cycle gas/steam turbine system results indicated competitive efficiency and a lower cost of electricity compared to the reference steam plant. The Open-Cycle MHD system results indicated the potential for significantly higher efficiency than the reference steam plant but with a higher cost of electricity.

Corman, J. C.

Thermionic energy conversion technology - Present and future

Aerospace and terrestrial applications of thermionic direct energy conversion and advances in direct energy conversion (DEC) technology are surveyed. Electrode materials, the cesium plasma drop (the difference between the barrier index and the collector work function), DEC voltage/current characteristics, conversion efficiency, and operating temperatures are discussed. Attention is centered on nuclear reactor system thermionic DEC devices, for in-core or out-of-core operation. Thermionic fuel elements, the radiation shield, power conditions, and a waste heat rejection system are considered among the thermionic DEC system components. Terrestrial applications include topping power systems in fossil fuel and solar power generation.

Shimada, K.

Insolation data for solar energy conversion derived from satellite measurements of earth radiance

Detailed knowledge of the irradiance of the sun at ground locations is essential for the design and evaluation of solar energy conversion systems. The primary source of such data is the global network of weather stations. Such stations are often too far apart and for most locations the data available are only daily total irradiance or monthly averages. Solar energy conversion programs require insolation data with considerably higher geographical and temporal resolution. Meteorological satellites gather routinely extensive data on the energy reflected and scattered into space by the earth-atmosphere system. A program has been initiated to use such data for deriving ground insolation for energy conversion. Some of the preliminary results of this program will be discussed.

Thekaekara, M. P.